3Ware 9550SXU-16ML User Guide - Page 235

h Buffer ECC error corrected, 03Ah Drive power on reset detected, 03Bh Rebuild paused

Page 235 highlights

AEN Messages 039h Buffer ECC error corrected This AEN will be sent when the controller has detected and corrected a memory ECC error. 03Ah Drive power on reset detected If the controller detects that a drive has been power-cycled, it will send this AEN. The controller may degrade the unit (if possible). 03Bh Rebuild paused This AEN will be sent when the rebuild operation is paused. Rebuilds are normally paused for ten minutes after a system first boots up and during non-scheduled times when scheduling is enabled. 03Ch Initialize paused This AEN will be sent when the initialization is paused. Initializations are normally paused for ten minutes after a system first boots up and during non-scheduled times when scheduling is enabled. Initializations follow the rebuild schedule. 03Dh Verify paused This AEN will be sent when the verify operation is paused. Verifies are normally paused for ten minutes after a system first boots up and during non-scheduled times when scheduling is enabled. 03Eh Migration paused This AEN is sent when migration is paused. Migration follows the rebuild schedule. For more information, see "Scheduling Background Tasks" on page 176. 03Fh Flash file system error detected The 3ware RAID controller stores some configuration parameters as files in its flash memory. This AEN will be sent when a corrupted flash file system is found on the controller during boot-up. A further attempt will be made to repair the flash file system. These files usually get corrupted when a flash operation is interrupted by events such as power failures. 040h Flash file system repaired This AEN will be sent if a corrupted flash file system is successfully repaired. Some of the flash files with insufficient data may be lost in the operation. The www.3ware.com 225

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260

AEN Messages
www.3ware.com
225
039h Buffer ECC error corrected
This AEN will be sent when the controller has detected and corrected a
memory ECC error.
03Ah Drive power on reset detected
If the controller detects that a drive has been power-cycled, it will send this
AEN. The controller may degrade the unit (if possible).
03Bh Rebuild paused
This AEN will be sent when the rebuild operation is paused.
Rebuilds are normally paused for ten minutes after a system first boots up and
during non-scheduled times when scheduling is enabled.
03Ch Initialize paused
This AEN will be sent when the initialization is paused.
Initializations are normally paused for ten minutes after a system first boots
up and during non-scheduled times when scheduling is enabled. Initializations
follow the rebuild schedule.
03Dh Verify paused
This AEN will be sent when the verify operation is paused.
Verifies are normally paused for ten minutes after a system first boots up and
during non-scheduled times when scheduling is enabled.
03Eh Migration paused
This AEN is sent when migration is paused. Migration follows the rebuild
schedule. For more information, see “Scheduling Background Tasks” on
page 176.
03Fh Flash file system error detected
The 3ware RAID controller stores some configuration parameters as files in
its flash memory. This AEN will be sent when a corrupted flash file system is
found on the controller during boot-up. A further attempt will be made to
repair the flash file system. These files usually get corrupted when a flash
operation is interrupted by events such as power failures.
040h Flash file system repaired
This AEN will be sent if a corrupted flash file system is successfully repaired.
Some of the flash files with insufficient data may be lost in the operation. The