Photometer, TOPCON BM-5A, LCD Module, LCD Panel, Center of the Screen
View all Acer AL1703 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
(4) Measurement Setup: The LCD module should be stabilized at given temperature for 20 minutes to avoid abrupt temperature change during measuring. In order to stabilize the luminance, the measurement should be executed after lighting Backlight for 20 minutes in a windless room. LCD Module LCD Panel Center of the Screen Photometer (TOPCON BM-5A) Field of View = 2 º 500 mm Light Shield Room (Ambient Luminance < 2 lux) 11