Acer AL1913 AL1913W Service Guide - Page 11
Horizontal Line Number [pixel]
View all Acer AL1913 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
(2) Definition of Contrast Ratio (CR): The contrast ratio can be calculated by the following expression and figure below. Contrast Ratio (CR) = L255 / L0 L255: Luminance of gray level 255 L 0: Luminance of gray level 0 CR = CR (5) CR (X) is corresponding to the Contrast Ratio of the point X at Figure in Note (5). Definition of luminance measured points and Brightness Uniformity: Horizontal Line Number [pixel] Vertical Line Number [pixel] : test point X (Minolta CA-210) Active area Delta X=17.0mm;Delta Y=17.0mm Luminance of center point: L=L(1) Brightness Uniformity Measurement points: Five specified points 1-5 Formula: Maximum [L (1), L (2), L (3), L (4), L (5), L (6), L (7), L (8), L (9), L (10), L (11), L (12), L (13)]/Minimum [L (1), L (2), L (3), L (4), L (5), L (6), L (7), L (8), L (9), L (10), L (11), L (12), L (13)] 11