Electrical Requirements - specifications

Page 8 highlights

Electrical Requirements Standard Test Conditions All tests shall be performed under the following conditions, unless otherwise specified. Ambient light Viewing distance Warm up time All specifications Fully functional Measuring equipment Control settings User brightness control User contrast control User red/white balance, Green/white balance and Blue/white balance control Power input Ambient temperature Analog input mode Measurement systems 225 lux 40 cm in front of LCD panel 30 minutes 5 seconds Chroma 7120 signal generator or equivalent, directly Connected to the monitor under test. Maximum (unless otherwise specified) Typical (unless otherwise specified) In the center (unless otherwise specified) 100Vac or 264Vac 20+5¥ 1280 x1024 /75 Hz The units of measure stated in this document are listed below: 1 gamma = 1 nano tesla 1 tesla = 10,000 gauss cm = in x 2.54 lb = kg x 2.2 degrees F = [°C x 1.8] + 32 degrees C = [°F - 32]/1.8 u' = 4x/(-2x + 12y + 3) v' = 9y/(-2x + 12y + 3) x = (27u'/4)/[(9u'/2) - 12v' + 9] y = (3v')/[(9u'/2) - 12v' + 9] Nits = cd/(m2) = Ft-L x 3.426 lux = foot-candle x 10.76 7