Acer AL922 AL922 Monitor Service Guide - Page 40

Power Line Transient Test IEC 61000-4-4 Fast, Transients/Burst

Page 40 highlights

8.7 Plastic Material Front Bezel ABS 94HB, 94V-0 Back Cover ABS 94HB, 94V-0 The Others ABS 94HB TCO' 99(Optional) Front Bezel PC + ABS 94 - V0 BACK COVER PC + ABS 94 - V0 The others ABS 94 HB 8.8 GAP Spec. Gap between panel with bezel is 0 mm < gap < 1.5 mm 9. Power Line Transient Test (IEC 61000-4-4 Fast Transients/Burst) TEST CONDITIONS & PROCEDURE: (Follow IEC 61000-4-4) Test Condition : The condition is base on operating with 50Ω load. 9.1 Peak Voltage: 2 KV (applies the Level 3 typical Industrial Environment" of IEC 61000-4-4) 9.2 Polarity : + / - 9.3 Repetition Frequency of the impulse : 5 KHz. 40