EDID Key-In Procedure, In Write Source Select item, select

Page 98 highlights

6-4 EDID Key-In Procedure 1 1. Execute EDID Program (1) Click on "EDID" to execute EDID program. 2. Process (1) Check the COM port is "COM 1" (Select the COM port which you are using). (2) Click the "Model" button. (3) Choose the source file "ACER_P3250_20080218_C.ini" and then open it. 3. Process (1) Key in the serial number into the barcode blank space. (2) In "Write Source Select" item,select "Analog". (3) Click "Program" button. 4. Process (1) "Please change the cable to Analog" will be shown on the screen. (2) Please press "Ok" button. 2 (2) (1) (3) 3 (1) (3) (2) 4 P3150/P3250/P3150 Refresh/P3250 Refresh Confidential 6-4