EDID Key-In Procedure, In Write Source Select item, select
UPC - 884483443383
View all Acer P5271 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
6-4 EDID Key-In Procedure (VGA) 1. Execute EDID Program - Double click "EDID" to execute EDID program. 2. Process (1) Select the COM Port which you are using. (2) Click "Model". (3) Select the EDID file (*.ini). (4) Click "Open". (5) Key in the Serial Number into the Barcode blank space. (6) In "Write Source Select" item, select "Analog". (7) Click "Program". (2) (1) (3) (4) (5) (7) (6) P5290/P5271/P5390W/P5271i Confidential 6-