Acer X163W X163W LCD Monitor Service Guide - Page 14

SOP of firmware upgrade

Page 14 highlights

Acer OSD Input Info Reset Exit Deutsch Deutsch --- Español Español --- 简ᠧʕ˖ Hollands --- ᐿ᜗ʕ˖ --- Français Français --- Italiano Italiano --- ˚͉Ⴇ Suomalainen --- Hor. Position --- Ver. Position --- OSD Timeout --- Analog --- Digital --- Resolution --- H. Freq --- V. Freq --- --- --- --- --- 0 ~ 100 0 ~ 100 10~ 120 Notes; ○1 Clock default 50 is for Visa timing. Others depend on timing. Acer -LCD-X163W 50 50 20 8.0 SOP of firmware upgrade 8.1 Operational condition: Equipment: PC, ISP card, signal cable and power cable. ESD requirements: antistatic wrists, antistatic gloves (fingers), and connecting cable Name of ISP program: ISP_Tool_v3.7.5.3 Manufacture of FW ICjPMC/SST/MX 8.2 Operational steps: 1. Connection: connect PC to PCBA with signal cable, and then keep AC and DC in open state. One port of ISP program card is connected to PC print port. 13

We apologize, but we cannot currently deliver this PDF manual by request of the manufacturer.