Abnormal OSM display adjust problem

Page 26 highlights

5.6 Abnormal OSM display adjust problem 5. Troubleshooting (continued) ACER X193HQ 25 Go to cover page Check the input TTL level whether was changed when pressed function keys on the P304 pin3, 5 (normal is high level, when push buttom, generated low level plus) NG OK Failure Point 1) Function key wire disconnection. 2) Function key wire is failure. 3) Function key board is failure. Check the input TTL level of I305 pin20, 21 whether was changed when pressed function keys. (Refer to Table 1) NG OK Failure Point I305 is failure. Failure Point 1) Printed wire broke among P304 pin3,R350 and I305 pin21 2) Printed wire broke among P304 pin5 ,R349 and I305 pin20 3) C358,C359 is short. 4) R374, R375 is short or open. 5) D327,D328 is short