Checking the resolution change IC movement

Page 30 highlights

5. Troubleshooting (continued) 5.10 Checking the resolution change IC movement ACER X193HQ 29 Go to cover page Check +3.3V supply on I305 pin41,I308 pin1,46. NG OK Proceed " Checking the DC/DC converter circuit" section. Check +1.8V supply on I308 pin 19,17,40. NG OK Proceed " Checking the DC/DC converter circuit" section. Check X300 24MHz clock input to I305 pin 15 and 16 at TTL level. NG OK Check I305 pin 4 RST signal is low level at normal operation. OK Failure Point 1) Printed wire broke between X300 and I305 pin 15, 16. 2) C340, C341 is short or open. 3) X300 failure. Failure Point 1) Printer wire broke between I305 pin 4 and C345 2) C345 is short. NG 3) I305 is failure. Check I305 pin 38,39,40 IIC signal. Failure Point I305 failure. NG OK Failure Point 1) Printed wire broke between I305 pin 38, 39, 40 and I303 pin 5, 6,7. 2) R351,R352,R353 is open. 3) R395,R396,R397 is open or short. 4) I303 is failure.

We apologize, but we cannot currently deliver this PDF manual by request of the manufacturer.

You can visit the Acer X193 on the Acer site to download this or other manuals by visiting this link.

We apologize for any inconveniece.