Checking the resolution change IC movement
View all Acer X193 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
5. Troubleshooting (continued) 5.10 Checking the resolution change IC movement ACER X193HQ 29 Go to cover page Check +3.3V supply on I305 pin41,I308 pin1,46. NG OK Proceed " Checking the DC/DC converter circuit" section. Check +1.8V supply on I308 pin 19,17,40. NG OK Proceed " Checking the DC/DC converter circuit" section. Check X300 24MHz clock input to I305 pin 15 and 16 at TTL level. NG OK Check I305 pin 4 RST signal is low level at normal operation. OK Failure Point 1) Printed wire broke between X300 and I305 pin 15, 16. 2) C340, C341 is short or open. 3) X300 failure. Failure Point 1) Printer wire broke between I305 pin 4 and C345 2) C345 is short. NG 3) I305 is failure. Check I305 pin 38,39,40 IIC signal. Failure Point I305 failure. NG OK Failure Point 1) Printed wire broke between I305 pin 38, 39, 40 and I303 pin 5, 6,7. 2) R351,R352,R353 is open. 3) R395,R396,R397 is open or short. 4) I303 is failure.