Adaptec 2231700-R Solutions Guide
Adaptec 2231700-R - 5M Int Mini-sas X4 SFF-8087 Manual
UPC - 760884153147
View all Adaptec 2231700-R manuals
Add to My Manuals
Save this manual to your list of manuals |
Adaptec 2231700-R manual content summary:
- Adaptec 2231700-R | Solutions Guide - Page 1
Adaptec Solutions Guide - Adaptec 2231700-R | Solutions Guide - Page 2
- Adaptec 2231700-R | Solutions Guide - Page 3
3805 SUPERMICRO Backplane 743TQ 1 Adaptec RAID 3405 SUPERMICRO Backplane 815TQ 7 Adaptec RAID 31205 SUPERMICRO Backplane 826TQ 11 Adaptec RAID 31605 SUPERMICRO Backplane 836TQ 17 Adaptec RAID 31205 Intel Backplane 5400 SEP 25 Adaptec RAID 3405 Intel Backplane 5400 Expander 29 Adaptec RAID 3405 - Adaptec 2231700-R | Solutions Guide - Page 4
- Adaptec 2231700-R | Solutions Guide - Page 5
Adaptec RAID 3805 SUPERMICRO Backplane 743TQ Firmware Version b12379 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with Sideband 1 - Adaptec 2231700-R | Solutions Guide - Page 6
AOdradpetrecNSuomlubteiorn: s2G2u4i7d0e00-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 3805 Connector 743TQ Connector 2247000-R #1 CON0 - 0 J5 CON0 - 1 J6 CON0 - 2 J7 CON0 - 3 J8 CON0 - Sideband JP51 2247000-R #2 CON1 - 0 J9 CON1 - 1 J10 CON1 - 2 J11 CON1 - 3 J12 - Adaptec 2231700-R | Solutions Guide - Page 7
Adaptec RAID 3805 with SMC 743TQ Backplane SEP Vendor AMI MG9072 Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings 3 - Adaptec 2231700-R | Solutions Guide - Page 8
Adaptec Solutions Guide I2C Jumper Placement Backplane Type 1 2-3 (1) = JP34 Backplane Type 2 2-3 (2) = JP37 Controller Type 1 2-3 (1) = JP33 Controller Type 2 2-3 (2) = JP36 I2C Reset #1 = ON JP50 I2C Reset #2 = ON JP38 SDout #1 = JP40 OFF SDout #2 = JP41 OFF Backplane Type 2 - Adaptec 2231700-R | Solutions Guide - Page 9
Type 2 (2) = JP36 I2C Reset #1 = JP50 I2C Reset #2 = JP38 SDout #1 = JP40 SDout #2 = JP41 Backplane Type 2 (2) = JP42 Backplane Type 2 (2) = JP43 SGPIO Jumper Placement 1-2 1-2 1-2 1-2 OFF OFF ON ON 2-3 1-2 Copyright 2007 Adaptec, Inc. All rights reserved. Adaptec RAID 3805 with SMC 743TQ - Adaptec 2231700-R | Solutions Guide - Page 10
- Adaptec 2231700-R | Solutions Guide - Page 11
RAID 3405 SUPERMICRO Backplane 815TQ Firmware Version b12379 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with Sideband Order Number: 2247000-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 3405 Connector 815TQ Connector 2247000-R #1 CON0 - 0 J5 CON0 - 1 J6 - Adaptec 2231700-R | Solutions Guide - Page 12
Adaptec Solutions CGOuiNd0e - 3 CON0 - Sideband J8 JP51 SEP Vendor 8 - Adaptec 2231700-R | Solutions Guide - Page 13
SGPIO: Jumper Settings I2C Jumper Placement Backplane Type 1 2-3 (1) = JP34 Controller Type 1 2-3 (1) = JP33 I2C Reset #1 = ON JP50 SDout #1 = JP40 OFF Backplane Type 2 2-3 (2) = JP42 OR Jumper Settings Backplane Type 1 SGPIO Jumper Placement 1-2 Adaptec RAID 3405 with SMC 815TQ - Adaptec 2231700-R | Solutions Guide - Page 14
A(1d)ap=teJcPS3o4lutions Guide Controller Type 1 1-2 (1) = JP33 I2C Reset #1 = OFF JP50 SDout #1 = JP40 ON Backplane Type 2 1-2 (2) = JP42 Copyright 2007 Adaptec, Inc. All rights reserved. 10 - Adaptec 2231700-R | Solutions Guide - Page 15
Adaptec RAID 31205 SUPERMICRO Backplane 826TQ Firmware Version b12380 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with Sideband Order Number: 2247000-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 31205 Connector 826TQ Connector 11 - Adaptec 2231700-R | Solutions Guide - Page 16
A22d4ap7t0e0c0S-Rol#ut1ions GCuOidNe0 - 0 CON0 - 1 CON0 - 2 CON0 - 3 CON0 - Sideband 2247000-R #2 CON1 - 4 CON1 - 5 CON1 - 6 CON1 - 7 CON1 - Sideband 2247000-R #3 CON2 - 8 CON2 - 9 CON2 - 10 CON2 - 11 CON2 - sideband J5 J6 J7 J8 JP66 J10 J12 J14 J16 JP68 J22 J23 J24 J25 JP75 12 - Adaptec 2231700-R | Solutions Guide - Page 17
Adaptec RAID 31205 with SMC 826TQ Backplane SEP Vendor AMI MG9072 Use one of the following Jumper settings I2C OR SGPIO: Jumper 13 - Adaptec 2231700-R | Solutions Guide - Page 18
ASdeattpitnegcsSolutions Guide I2C Jumper Placement Backplane Type 2-3 1 (1) = JP85 Backplane Type 2-3 2 (2) = JP102 Backplane Type 2-3 3 (3) = JP91 Controller Type 2-3 1 (1) = JP84 Controller Type 2-3 2 (2) = JP101 Controller Type 2-3 3 (3) = JP90 I2C Reset #1 = ON JP83 I2C - Adaptec 2231700-R | Solutions Guide - Page 19
ID_SDin#1 = 2-3 JP65 ID_SDin#2 = 2-3 JP67 ID_SDin#3 = 2-3 JP74 OR Jumper Settings Backplane Type 1 (1) = JP85 Backplane Type 2 (2) = JP102 Backplane Type 3 (3) = JP91 Controller Type 1 (1) = JP84 SGPIO Jumper Placement 1-2 1-2 1-2 1-2 Adaptec RAID 31205 with SMC 826TQ Backplane 15 - Adaptec 2231700-R | Solutions Guide - Page 20
I2C Reset #2 = OFF JP86 I2C Reset #3 = OFF JP89 SDout #1 = JP87 ON SDout #2 = JP88 ON SDout #3 = JP93 ON ID_SDin#1 = 1-2 JP65 ID_SDin#2 = 1-2 JP67 ID_SDin#3 = 1-2 JP74 Copyright 2007 Adaptec, Inc. All rights reserved. 16 - Adaptec 2231700-R | Solutions Guide - Page 21
Adaptec RAID 31605 SUPERMICRO Backplane 836TQ Firmware Version b12380 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with Sideband Order Number: 2247000-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 31605 Connector 836TQ Connector 17 - Adaptec 2231700-R | Solutions Guide - Page 22
A22d4ap7t0e0c0S-Rol#ut1ions GCuOiNde0 - 0 CON0 - 1 CON0 - 2 CON0 - 3 CON0 - Sideband 2247000-R #2 CON1 - 4 CON1 - 5 CON1 - 6 CON1 - 7 CON1 - Sideband 2247000-R #3 CON2 - 8 CON2 - 9 CON2 - 10 CON2 - 11 CON2 - sideband 2247000-R #4 CON3 - 12 CON3 - 13 CON3 - 14 18 J5 J6 J7 J8 JP66 J10 J12 J14 - Adaptec 2231700-R | Solutions Guide - Page 23
CON3 - 15 J22 CON3 - sideband J22 Adaptec RAID 31605 with SMC 836TQ Backplane SEP Vendor 19 - Adaptec 2231700-R | Solutions Guide - Page 24
AdMaIpMteGc9S0o7l2utions Guide Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings I2C Jumper Placement Backplane 2-3 Type 1 (1) = JP85 Backplane 2-3 Type 2 (2) = JP102 Backplane 2-3 Type 3 (3) = JP91 Backplane 2-3 Type 4 (4) = JP104 Controller 2-3 Type 1 (1) - Adaptec 2231700-R | Solutions Guide - Page 25
#3 = JP89 I2C Reset ON #4 = JP92 SDout #1 = OFF JP87 SDout #2 = OFF JP88 SDout #3 = OFF JP93 SDout #4 = OFF JP94 ID_SDin#1 2-3 = JP65 ID_SDin#2 2-3 = JP67 ID_SDin#3 2-3 = JP74 ID_SDin#4 2-3 = JP76 Adaptec RAID 31605 with SMC 836TQ Backplane 21 - Adaptec 2231700-R | Solutions Guide - Page 26
Adaptec Solutions Guide OR Jumper Settings Backplane Type 1 (1) = JP85 Backplane Type 2 (2) = JP102 Backplane Type 3 (3) = JP91 Backplane Type 4 (4) = JP104 SGPIO Jumper Placement 1-2 1-2 1-2 1-2 22 - Adaptec 2231700-R | Solutions Guide - Page 27
I2C Reset OFF #2 = JP86 I2C Reset OFF #3 = JP89 I2C Reset OFF #4 = JP92 SDout #1 ON = JP87 SDout #2 ON = JP88 SDout #3 ON = JP93 SDout #4 ON = JP94 ID_SDin#1 1-2 Adaptec RAID 31605 with SMC 836TQ Backplane 23 - Adaptec 2231700-R | Solutions Guide - Page 28
A=dJaPp6te5c Solutions Guide ID_SDin#2 1-2 = JP67 ID_SDin#3 1-2 = JP74 ID_SDin#4 1-2 = JP76 Copyright 2007 Adaptec, Inc. All rights reserved. 24 - Adaptec 2231700-R | Solutions Guide - Page 29
Adaptec RAID 31205 Intel Backplane 5400 SEP Firmware Version b12380 or higher 25 - Adaptec 2231700-R | Solutions Guide - Page 30
ACdaabpleteRc eSqouluitrieomnseGnutsid:eData cable SFF-8087 to (4) SATA with Sideband Order Number: 2236600-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 31205 Connector Axx6DRV3G 2236600-R #1 CON0 - 0 HDD - 0 CON0 - 1 HDD - 1 CON0 - 2 HDD - 2 CON0 - 3 HDD - 3 2236600-R #2 - Adaptec 2231700-R | Solutions Guide - Page 31
Adaptec RAID 31205 with Intel 5400 SEP Vendor Vitesse VSC410 Copyright 2007 Adaptec, Inc. All rights reserved. 27 - Adaptec 2231700-R | Solutions Guide - Page 32
- Adaptec 2231700-R | Solutions Guide - Page 33
Adaptec RAID 3405 Intel Backplane 5400 Expander Note: Must have firmware version 2.06 or higher. 29 - Adaptec 2231700-R | Solutions Guide - Page 34
or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with Sideband Order Number: 2236600-R Model: ACK-I-mSASx4-4SATAx1-0.5M R Description Adaptec 3805 Connector Intel 5400 Connector 2236600-R #1 CON0 - 0 SAS - 0 CON0 - 1 SAS - 1 CON0 - Not Used SAS - 2 CON0 - Not Used SAS - 3 30 - Adaptec 2231700-R | Solutions Guide - Page 35
Adaptec RAID 3405 with Intel 5400 w/Expander SEP Vendor Vitesse VSC410 Enclosure Management is inband, no sideband required. Copyright 2007 Adaptec, Inc. All rights reserved. 31 - Adaptec 2231700-R | Solutions Guide - Page 36
- Adaptec 2231700-R | Solutions Guide - Page 37
Adaptec RAID 3405 SUPERMICRO Backplane 733TQ Firmware Version b12379 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with 33 - Adaptec 2231700-R | Solutions Guide - Page 38
ASdidaepbteacnSdolutions Guide Order Number: 2247000-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 3405 Connector 733TQ Connector 2247000-R #1 CON0 - 0 J5 CON0 - 1 J6 CON0 - 2 J7 CON0 - 3 J8 CON0 - Sideband JP51 34 - Adaptec 2231700-R | Solutions Guide - Page 39
Adaptec RAID 3405 with SMC 733TQ Backplane SEP Vendor AMI MG9072 Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings 35 - Adaptec 2231700-R | Solutions Guide - Page 40
Adaptec Solutions Guide I2C Jumper Placement Backplane Type 1 2-3 (1) = JP34 Controller Type 1 2-3 (1) = JP33 I2C Reset #1 = ON JP50 SDout #1 = JP40 OFF Backplane Type 2 2-3 (2) = JP42 OR Jumper Settings Backplane Type 1 (1) = JP34 Controller Type 1 (1) = JP33 I2C Reset #1 = JP50 - Adaptec 2231700-R | Solutions Guide - Page 41
SDout #1 = JP40 ON Backplane Type 2 1-2 (2) = JP42 Copyright 2007 Adaptec, Inc. All rights reserved. Adaptec RAID 3405 with SMC 733TQ Backplane 37 - Adaptec 2231700-R | Solutions Guide - Page 42
- Adaptec 2231700-R | Solutions Guide - Page 43
Adaptec RAID 3405 SUPERMICRO Backplane 810TQ Firmware Version b12379 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with Sideband Order Number: 2247000-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R 39 - Adaptec 2231700-R | Solutions Guide - Page 44
ADdeaspctreipc tSiolnutions AGduiadpetec 3405 Connector 810TQ Connector 2247000-R #1 CON0 - 0 J5 CON0 - 1 J6 CON0 - not used J7 CON0 - not used J8 CON0 - Sideband JP51 40 - Adaptec 2231700-R | Solutions Guide - Page 45
Adaptec RAID 3405 with SMC 810 TQ Backplane SEP Vendor AMI MG9071 Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings 41 - Adaptec 2231700-R | Solutions Guide - Page 46
Adaptec Solutions Guide I2C Jumper Placement Backplane Type 1 2-3 (1) = JP34 Controller Type 1 2-3 (1) = JP33 I2C Reset #1 = ON JP50 SDout #1 = JP40 OFF Backplane Type 2 2-3 (2) = JP42 OR Jumper Settings Backplane Type 1 (1) = JP34 Controller Type 1 (1) = JP33 I2C Reset #1 = JP50 - Adaptec 2231700-R | Solutions Guide - Page 47
SDout #1 = JP40 ON Backplane Type 2 1-2 (2) = JP42 Copyright 2007 Adaptec, Inc. All rights reserved. Adaptec RAID 3405 with SMC 810 TQ Backplane 43 - Adaptec 2231700-R | Solutions Guide - Page 48
- Adaptec 2231700-R | Solutions Guide - Page 49
Adaptec RAID 3405 SUPERMICRO Backplane 813TQ Firmware Version b12379 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with 45 - Adaptec 2231700-R | Solutions Guide - Page 50
ASdidaepbteacnSdolutions Guide Order Number: 2247000-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 3405 Connector 813TQ Connector 2247000-R #1 CON0 - 0 J5 CON0 - 1 J6 CON0 - 2 J7 CON0 - 3 J8 CON0 - Sideband JP51 46 - Adaptec 2231700-R | Solutions Guide - Page 51
Adaptec RAID 3405 with SMC 813TQ Backplane SEP Vendor AMI MG9071 Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings 47 - Adaptec 2231700-R | Solutions Guide - Page 52
Adaptec Solutions Guide I2C Jumper Placement Backplane Type 1 2-3 (1) = JP34 Controller Type 1 2-3 (1) = JP33 I2C Reset #1 = ON JP50 SDout #1 = JP40 OFF Backplane Type 2 2-3 (2) = JP42 OR Jumper Settings Backplane Type 1 (1) = JP34 Controller Type 1 (1) = JP33 I2C Reset #1 = JP50 - Adaptec 2231700-R | Solutions Guide - Page 53
SDout #1 = JP40 ON Backplane Type 2 1-2 (2) = JP42 Copyright 2007 Adaptec, Inc. All rights reserved. Adaptec RAID 3405 with SMC 813TQ Backplane 49 - Adaptec 2231700-R | Solutions Guide - Page 54
- Adaptec 2231700-R | Solutions Guide - Page 55
Adaptec RAID 3405 SUPERMICRO Backplane 814 Firmware Version b12379 or higher Cable Requirements: Data cable internal mini Serial Attached SCSI x4 51 - Adaptec 2231700-R | Solutions Guide - Page 56
A(SdFaFpt-e8c0S8o7l)uttioonxs4G(uSidFeF-8484) Serial Attached SCSI Order Number: 2231700-R Model: ACK-I-mSASx4-SASx4-0.5M R Description Adaptec 3405 Connector 814 Connector 2231700-R #1 CON0 - 0 CON0 - 1 CON0 - 2 CON0 - 3 CON0 - Sideband 52 - Adaptec 2231700-R | Solutions Guide - Page 57
Adaptec RAID 3405 with SMC 814 Backplane 53 - Adaptec 2231700-R | Solutions Guide - Page 58
Adaptec Solutions Guide Copyright 2007 Adaptec, Inc. All rights reserved. 54 - Adaptec 2231700-R | Solutions Guide - Page 59
Adaptec RAID 3405 SUPERMICRO Backplane 816A Firmware Version b12379 or higher 55 - Adaptec 2231700-R | Solutions Guide - Page 60
ACdaabpleteRc eSqouluitrieomnseGnutsid:eData cable internal Mini Serial Attached SCSI x4 (SFF-8087) to x4 (SFF-8087) Mini Serial Attached SCSI Order Number: 2246800-R Model: ACK-I-mSASx4-mSASx4-0.5m R Description Adaptec 3405 Connector 816A Connector 2246800-R #1 CON0 - 0 J5 56 - Adaptec 2231700-R | Solutions Guide - Page 61
Adaptec RAID 3405 with SMC 816A Backplane SEP Vendor AMI MG9071 57 - Adaptec 2231700-R | Solutions Guide - Page 62
Adaptec Solutions Guide Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings I2C Jumper Placement Backplane Type 1 2-3 (1) = JP34 Controller Type 1 2-3 (1) = JP33 I2C Reset #1 = ON JP50 SDout #1 = JP40 OFF Backplane Type 2 2-3 (2) = JP42 OR Jumper Settings - Adaptec 2231700-R | Solutions Guide - Page 63
(1) = JP33 I2C Reset #1 = OFF JP50 SDout #1 = JP40 ON Backplane Type 2 1-2 (2) = JP42 Copyright 2007 Adaptec, Inc. All rights reserved. Adaptec RAID 3405 with SMC 816A Backplane 59 - Adaptec 2231700-R | Solutions Guide - Page 64
- Adaptec 2231700-R | Solutions Guide - Page 65
Adaptec RAID 3405 SUPERMICRO Backplane 836EL1 Firmware Version b12379 or higher 61 - Adaptec 2231700-R | Solutions Guide - Page 66
ACdaabpleteRc eSqouluitrieomnseGnutsid:eData cable internal Mini Serial Attached SCSI x4 (SFF-8087) to x4 (SFF-8087) Mini Serial Attached SCSI, No sideband Order Number: 2257900-R Model: ACK-I-mSASx4-mSASx4-NoSB-0.5M Description Adaptec 3405 Connector 836EL Connector 2257900-R #1 CON0 - 0 J5 62 - Adaptec 2231700-R | Solutions Guide - Page 67
Adaptec RAID 3405 with SMC 836EL Backplane Expander Vendor LSISASx28 - Must have boot record version 1.2 or higher OR MFG date of 5/5/07 or higher. 63 - Adaptec 2231700-R | Solutions Guide - Page 68
Adaptec Solutions Guide Copyright 2007 Adaptec, Inc. All rights reserved. 64 - Adaptec 2231700-R | Solutions Guide - Page 69
Adaptec RAID 3405 SUPERMICRO Backplane 933EL1 Firmware Version b12379 or higher 65 - Adaptec 2231700-R | Solutions Guide - Page 70
ACdaabpleteRc eSqouluitrieomnseGnutsid:eData cable internal Mini Serial Attached SCSI x4 (SFF-8087) to x4 (SFF-8087) Mini Serial Attached SCSI No Sideband Order Number: 2257900-R Model: ACK-I-mSASx4-mSASx4-NoSB-0.5M Description Adaptec 3405 Connector 933EL Connector 2257900-R #1 CON0 - 0 J5 66 - Adaptec 2231700-R | Solutions Guide - Page 71
Adaptec RAID 3405 with SMC 933E1 Backplane Expander Vendor LSISASx28 - Must have boot record label "Boot:1.0" or higher OR MFG date of 5/5/07 or higher. 67 - Adaptec 2231700-R | Solutions Guide - Page 72
Adaptec Solutions Guide Copyright 2007 Adaptec, Inc. All rights reserved. 68 - Adaptec 2231700-R | Solutions Guide - Page 73
Adaptec RAID 3805 Intel Backplane 5400 SEP Firmware Version b12415 or higher 69 - Adaptec 2231700-R | Solutions Guide - Page 74
ACdaabpleteRc eSqouluitrieomnseGnutsid:eData cable SFF-8087 to (4) SATA with Sideband Order Number: 2236600-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5m R Description Adaptec 3805 Connector Intel 5400 Connector 2236600-R #1 CON0 - 0 SAS - 0 CON0 - 1 SAS - 1 CON0 - Not Used SAS - 2 CON0 - Not Used - Adaptec 2231700-R | Solutions Guide - Page 75
Adaptec RAID 3805 with Intel 5400 w/Expander SEP Vendor Vitesse VSC410 Copyright 2007 Adaptec, Inc. All rights reserved. 71 - Adaptec 2231700-R | Solutions Guide - Page 76
- Adaptec 2231700-R | Solutions Guide - Page 77
Adaptec RAID 3805 Supermicro Backplane 823TQ Firmware Version b12379 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with 73 - Adaptec 2231700-R | Solutions Guide - Page 78
ASdidaepbteacnSdolutions Guide Order Number: 2247000-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 3805 Connector 823TQ Connector 2247000-R #1 CON0 - 0 J5 CON0 - 1 J6 CON0 - 2 J7 CON0 - 3 J8 CON0 - Sideband JP51 2247000-R #2 CON1 - 0 J9 CON1 - 1 J10 CON1 - 2 J11 CON1 - Adaptec 2231700-R | Solutions Guide - Page 79
Adaptec RAID 3805 with SMC 823TQ Backplane SEP Vendor AMI MG9072 Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings 75 - Adaptec 2231700-R | Solutions Guide - Page 80
Adaptec Solutions Guide I2C Jumper Placement Backplane Type 1 2-3 (1) = JP34 Backplane Type 2 2-3 (2) = JP37 Controller Type 1 2-3 (1) = JP33 Controller Type 2 2-3 (2) = JP36 I2C Reset #1 = ON JP50 I2C Reset #2 = ON JP38 SDout #1 = JP40 OFF SDout #2 = JP41 OFF Backplane Type 2 - Adaptec 2231700-R | Solutions Guide - Page 81
Type 2 (2) = JP36 I2C Reset #1 = JP50 I2C Reset #2 = JP38 SDout #1 = JP40 SDout #2 = JP41 Backplane Type 2 (2) = JP42 Backplane Type 2 (2) = JP43 SGPIO Jumper Placement 1-2 1-2 1-2 1-2 OFF OFF ON ON 2-3 1-2 Copyright 2007 Adaptec, Inc. All rights reserved. Adaptec RAID 3805 with SMC 823TQ - Adaptec 2231700-R | Solutions Guide - Page 82
- Adaptec 2231700-R | Solutions Guide - Page 83
RAID 3805 with SMC 825TQ Backplane Firmware Version b12379 or higher Cable Requirements: Data cable SFF-8087 to (4) SATA with Sideband Order Number: 2247000-R Model: ACK-I-mSASx4-4SATAx1-SB-0.5M R Description Adaptec 3805 Connector 825TQ Connector 2247000-R #1 CON0 - 0 J5 CON0 - 1 J6 79 - Adaptec 2231700-R | Solutions Guide - Page 84
Adaptec Solutions GCOuiNd0e - 2 CON0 - 3 CON0 - Sideband 2247000-R #2 CON1 - 0 CON1 - 1 CON1 - 2 CON1 - 3 CON1 - Sideband J7 J8 JP51 J9 J10 J11 J12 80 - Adaptec 2231700-R | Solutions Guide - Page 85
Adaptec RAID 3805 with SMC 825TQ Backplane SEP Vendor AMI MG9072 Use one of the following Jumper settings I2C OR SGPIO: Jumper Settings 81 - Adaptec 2231700-R | Solutions Guide - Page 86
Adaptec Solutions Guide I2C Jumper Placement Backplane Type 1 2-3 (1) = JP34 Backplane Type 2 2-3 (2) = JP37 Controller Type 1 2-3 (1) = JP33 Controller Type 2 2-3 (2) = JP36 I2C Reset #1 = ON JP50 I2C Reset #2 = ON JP38 SDout #1 = JP40 OFF SDout #2 = JP41 OFF Backplane Type 2 - Adaptec 2231700-R | Solutions Guide - Page 87
Type 2 (2) = JP36 I2C Reset #1 = JP50 I2C Reset #2 = JP38 SDout #1 = JP40 SDout #2 = JP41 Backplane Type 2 (2) = JP42 Backplane Type 2 (2) = JP43 SGPIO Jumper Placement 1-2 1-2 1-2 1-2 OFF OFF ON ON 2-3 1-2 Copyright 2007 Adaptec, Inc. All rights reserved. Adaptec RAID 3805 with SMC 825TQ - Adaptec 2231700-R | Solutions Guide - Page 88
- Adaptec 2231700-R | Solutions Guide - Page 89
Adaptec RAID 3805 SUPERMICRO Backplane 933EL2 Firmware Version Under Development 85 - Adaptec 2231700-R | Solutions Guide - Page 90
ACdaabpleteRc eSqouluitrieomnseGnutsid:eData cable internal Mini Serial Attached SCSI x4 (SFF-8087) to x4 (SFF-8087) Mini Serial Attached SCSI, No sideband Order Number: 2257900-R Model: ACK-I-mSASx4-mSASx4-NoSB-0.5M Description Adaptec 3805 Connector 933E2 Connector 2257900-R #1 CON0 - 0 CON1 - - Adaptec 2231700-R | Solutions Guide - Page 91
Adaptec RAID 3805 with SMC 933E2 Backplane Expander Vendor LSISASx28 - Must have boot record label "Boot:1.0" or higher OR MFG date of 5/5/07 or higher. 87 - Adaptec 2231700-R | Solutions Guide - Page 92
Adaptec Solutions Guide Copyright 2007 Adaptec, Inc. All rights reserved. 88
Adaptec Solutions Guide