Amana AER6011VAS Installation Instruction

Amana AER6011VAS Manual

Amana AER6011VAS manual content summary:

  • Amana AER6011VAS | Installation Instruction - Page 1
    INSTALLATION INSTRUCTIONS 30" (76 CM) FREESTANDING ELECTRIC RANGES Table of Contents RANGE SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 3 Electrical Requirements - U.S.A. Only 4 INSTALLATION INSTRUCTIONS 6 Unpack Range 6 Install Anti-Tip Bracket 6 Electrical
  • Amana AER6011VAS | Installation Instruction - Page 2
    RANGE SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions
  • Amana AER6011VAS | Installation Instruction - Page 3
    It is the installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on the left side frame behind the storage drawer panel. ■ The range should be located for convenient use in the kitchen. ■ To eliminate the
  • Amana AER6011VAS | Installation Instruction - Page 4
    less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet. Electrical Requirements - U.S.A. Only If codes permit
  • Amana AER6011VAS | Installation Instruction - Page 5
    connection you will be using and follow the instructions provided for it here. ■ Range must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The model/serial number rating plate is located behind the control panel or on the oven
  • Amana AER6011VAS | Installation Instruction - Page 6
    INSTALLATION INSTRUCTIONS Unpack Range WARNING Excessive Weight Hazard Use two or more people to move and install range. Failure to do so can result in back or other injury. 1. Remove shipping materials, tape and film from range. 2. Remove oven racks and parts package from inside oven. 3. Do not
  • Amana AER6011VAS | Installation Instruction - Page 7
    grounded outlet. Failure to follow these instructions can result in death, fire, or electrical shock. Electrical Shock Hazard Disconnect power before servicing. Use 8 gauge copper or 6 gauge aluminum wire. Electrically ground range. Failure to follow these instructions can result in death, fire, or
  • Amana AER6011VAS | Installation Instruction - Page 8
    (NEMA type 14-50R) A UL listed, 250-volt minimum, 40-amp, range power supply cord 4-wire connection: Power supply cord A A. UL listed strain 1. Part of metal ground strap must be cut out and removed. A B C 5. Complete installation following instructions for your type of electrical connection
  • Amana AER6011VAS | Installation Instruction - Page 9
    wire from the power supply cord to the range with the ground-link screw and ground-link black) 3. Connect line 2 (red) and line 1 (black) wires to the outer terminal block posts with 10-32 hex nuts. 4. Securely tighten hex nuts. NOTE: For power supply cord replacement, use only a power cord rated
  • Amana AER6011VAS | Installation Instruction - Page 10
    Direct Wire Installation: Copper or Aluminum Wire This range may be connected directly to the fuse disconnect or circuit breaker box. Depending on your electrical supply, make the required 3-wire or 4-wire connection. 1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip the insulation
  • Amana AER6011VAS | Installation Instruction - Page 11
    1. Pull the wires through the conduit on cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block. A terminal lugs to line 2 (red), bare (green) ground, and line 1 (black) wires. Loosen (do not remove) the setscrew on the front of the terminal
  • Amana AER6011VAS | Installation Instruction - Page 12
    back into position. Check that rear leveling leg is engaged in anti-tip bracket. NOTE: Range must be level for satisfactory baking performance. 4. Replace the storage drawer (on some models). A. Drawer clip 3. Depress the drawer clip by pressing the screwdriver handle toward the side of the storage
  • Amana AER6011VAS | Installation Instruction - Page 13
    the Use and Care Guide for specific instruction on range operation. If range does not operate, check the following: ■ Household fuse is intact and tight; or circuit breaker has not tripped. ■ Range is plugged into an outlet. ■ Electrical supply is connected. ■ See "Troubleshooting" in the Use and
  • Amana AER6011VAS | Installation Instruction - Page 14
    -tip bracket is installed: ■ Look for the anti-tip bracket securely attached to floor. ■ Slide range back so rear range foot is under anti-tip bracket. Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or
  • Amana AER6011VAS | Installation Instruction - Page 15
    Left edge ANTI-TIP BRACKET TEMPLATE Cut on dotted lines and place the left edge against the left side cabinet and the top edge against the rear wall. Top edge 15
  • Amana AER6011VAS | Installation Instruction - Page 16
    W10252706B © 2009. All rights reserved. 9/09 Printed in U.S.A.
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

INSTALLATION INSTRUCTIONS
30" (76 CM) FREESTANDING ELECTRIC RANGES
Table of Contents
RANGE SAFETY
...................................................................................
2
INSTALLATION REQUIREMENTS
......................................................
3
Tools and Parts
..................................................................................
3
Location Requirements
......................................................................
3
Electrical Requirements - U.S.A. Only
...............................................
4
INSTALLATION INSTRUCTIONS
........................................................
6
Unpack Range
....................................................................................
6
Install Anti-Tip Bracket
.......................................................................
6
Electrical Connection - U.S.A. Only
...................................................
7
Verify Anti-Tip Bracket Location
......................................................
12
Level Range
......................................................................................
12
Storage Drawer
................................................................................
12
Complete Installation
.......................................................................
13
Moving the Range
............................................................................
14
ANTI-TIP BRACKET TEMPLATE
.....................................................
15
IMPORTANT:
Save for local electrical inspector's use.
W10252706B