Amana AGR6011VDS Installation Instruction

Amana AGR6011VDS Manual

Amana AGR6011VDS manual content summary:

  • Amana AGR6011VDS | Installation Instruction - Page 1
    INSTALLATION INSTRUCTIONS 30" (76.2 CM) FREESTANDING GAS RANGES Table of Contents RANGE SAFETY...2 INSTALLATION REQUIREMENTS 4 Tools and Parts...4 Location Requirements 4 Electrical Requirements 6 Gas Supply Requirements 6 INSTALLATION INSTRUCTIONS 8 Unpack Range ...8 Install Anti-Tip Bracket
  • Amana AGR6011VDS | Installation Instruction - Page 2
    from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency or the gas supplier. WARNING: Gas leaks cannot always be detected by smell
  • Amana AGR6011VDS | Installation Instruction - Page 3
    , the following installation instructions apply: ■ Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the State of Massachusetts. ■ If using a ball valve, it shall be a T-handle type. ■ A flexible gas connector, when
  • Amana AGR6011VDS | Installation Instruction - Page 4
    and ventilation air. ■ It is the installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on the oven frame behind the top left side of the oven door. ■ The range should be located for convenient use in
  • Amana AGR6011VDS | Installation Instruction - Page 5
    the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface. A. 18" (45.7 cm) upper side cabinet to countertop B. 13" (33 cm) max. upper cabinet depth C. 30" (76.2 cm) min. opening width D. For minimum clearance to top of cooktop, see
  • Amana AGR6011VDS | Installation Instruction - Page 6
    the manufacturer's instructions. Type of Gas Natural gas: This range is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas. ■ This range is factory set for use with Natural gas. See "Gas Conversions" section. The model/serial rating plate
  • Amana AGR6011VDS | Installation Instruction - Page 7
    at least 1" water column pressure above the manifold pressure shown on the model/serial rating plate. Line pressure testing above ½ psi gauge (14" WCP) The range and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test
  • Amana AGR6011VDS | Installation Instruction - Page 8
    INSTALLATION INSTRUCTIONS Unpack Range WARNING Excessive Weight Hazard Use two or more people to move and install range. Failure to do so can result in back or other injury. 1. Remove shipping materials, tape and film from range. 2. Remove oven racks and parts package from inside oven. 3. Do not
  • Amana AGR6011VDS | Installation Instruction - Page 9
    marked on the bracket template. Remove template from floor. Make Gas Connection WARNING To mount anti-tip installing your range using the following installation instructions. Typical rigid pipe connection A combination of pipe fittings must be used to connect the range to the existing gas
  • Amana AGR6011VDS | Installation Instruction - Page 10
    See "Storage Drawer" section. On models with a warming drawer, the rear leg cannot be seen by removing the warming drawer. It will be necessary to view the rear foot from outside the range. A. Gas pressure regulator shutoff valve 2. Open the manual shutoff valve in the gas supply line. The valve is
  • Amana AGR6011VDS | Installation Instruction - Page 11
    Height Adjust the height of top burner flames. The cooktop "low" burner flame should be a steady blue flame approximately ¼" (0.64 cm) high. A 3. If range is not level, pull range forward until rear leveling leg is removed from the anti-tip bracket. On Ranges Equipped with Storage Drawers: Use
  • Amana AGR6011VDS | Installation Instruction - Page 12
    and Care Guide for proper operation of the oven controls. Adjust Oven Bake Burner Flame (if needed) 1. On models with a warming drawer, remove access cover be adjusted, locate the air shutter near the center rear of the range. Loosen the locking screw and rotate the air shutter until the proper
  • Amana AGR6011VDS | Installation Instruction - Page 13
    and Care Guide for specific instruction on range operation. If range does not operate, check the following: ■ Household fuse is intact and tight, or circuit breaker has not tripped. ■ Range is plugged into a grounded 3 prong outlet. ■ Electrical supply is connected. ■ See "Troubleshooting" in the
  • Amana AGR6011VDS | Installation Instruction - Page 14
    or warming drawer compartment. NOTE: On models with a warming drawer, an access cover must be removed to access the gas pressure regulator. Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have
  • Amana AGR6011VDS | Installation Instruction - Page 15
    nut driver down onto the gas orifice spud and remove by turning it counterclockwise and lifting out. Set gas orifice spud aside. C A D LP Gas Orifice Spud Chart for Surface Burners Burner Rating Color Size ID Number 14,000 BTU 11,000 BTU 8,000 BTU 5,000 BTU Yellow/Orange Yellow/Brown Yellow
  • Amana AGR6011VDS | Installation Instruction - Page 16
    as the inner cone. LP gas flames have a slightly yellow tip. 3. Refer to "Complete Installation" in the "Installation Instructions" section of this manual to complete this procedure. Natural Gas Conversion WARNING To Convert Gas Pressure Regulator 1. Remove storage drawer or warming drawer. See
  • Amana AGR6011VDS | Installation Instruction - Page 17
    the burner base. NOTE: Reinstall one of the screws through the range cooktop to hold the orifice spud holder in place while removing and replacing the orifice spuds. C A D B A. Igniter electrode B. Gas tube opening C. Burner cap D. Burner base 3. Apply masking tape to the end of a 7 mm nut driver
  • Amana AGR6011VDS | Installation Instruction - Page 18
    the "LO" setting for each cooktop burner. Checking for proper cooktop, bake and broil burner flame is very important. Natural gas flames do not have yellow tips. 3. Refer to "Complete Installation" in the "Installation Instructions" section of this manual to complete this procedure. A B A. Lock
  • Amana AGR6011VDS | Installation Instruction - Page 19
    Left edge ANTI-TIP BRACKET TEMPLATE Cut on dotted lines and place the left edge against the left side cabinet and the top edge against the rear wall. Top edge 19
  • Amana AGR6011VDS | Installation Instruction - Page 20
    W10196161E © 2011. All rights reserved. 1/11 Printed in U.S.A.
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

INSTALLATION INSTRUCTIONS
30" (76.2 CM) FREESTANDING GAS RANGES
Table of Contents
RANGE SAFETY
..........................................................................................................
2
INSTALLATION REQUIREMENTS
.............................................................................
4
Tools and Parts
.........................................................................................................
4
Location Requirements
.............................................................................................
4
Electrical Requirements
............................................................................................
6
Gas Supply Requirements
........................................................................................
6
INSTALLATION INSTRUCTIONS
...............................................................................
8
Unpack Range
..........................................................................................................
8
Install Anti-Tip Bracket
.............................................................................................
8
Make Gas Connection
..............................................................................................
9
Verify Anti-Tip Bracket Location
.............................................................................
10
Level Range
............................................................................................................
11
Electronic Ignition System
......................................................................................
11
Replace Oven Racks and Warming Drawer
...........................................................
12
Storage Drawer
.......................................................................................................
13
Complete Installation
..............................................................................................
13
GAS CONVERSIONS
................................................................................................
14
LP Gas Conversion
.................................................................................................
14
Natural Gas Conversion
..........................................................................................
16
ANTI-TIP BRACKET TEMPLATE
............................................................................
19
IMPORTANT:
Save for local inspector's use.
Installer:
Leave installation instructions with the homeowner.
Homeowner:
Keep installation instructions for future reference.
W10196161E