Amana NGD4700YQ Dimension Guide

Amana NGD4700YQ Manual

Amana NGD4700YQ manual content summary:

  • Amana NGD4700YQ | Dimension Guide - Page 1
    Dryers Gas (U.S.A. and Canada) PRODUCT MODEL NUMBERS NGD4500V, NGD4600Y, NGD4700Y, NGD5100T Installation clearances: The location must be large enough to allow the dryer door to open fully. Most installations require a minimum 5½" (140 mm) clearance behind the dryer installation and servicing. ■■
  • Amana NGD4700YQ | Dimension Guide - Page 2
    larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1. ELECTRICAL REQUIREMENTS A 120-volt, 60 Hz, AC-only, 15
  • 1
  • 2

29" and 27" Dryers
Gas (U.S.A. and Canada)
PRODUCT MODEL NUMBERS
W10115228C
02/2012
NGD4500V, NGD4600Y,
NGD4700Y, NGD5100T
Installation clearances:
The location must be large enough to allow the dryer door to open fully.
Most installations require a minimum 5½" (140 mm) clearance behind the dryer for the exhaust vent with elbow.
A
B
C
18"*
(457 mm)
1"
(25 mm)
29"
(737 mm)
1"
(25 mm)
1"*
(25 mm)
14" max.*
(356
mm)
27
¾"
(705 mm)
48 in.
(310 cm )
2
*
2
3"*
(76 mm)
3"*
(76 mm)
24 in.
(155 cm )
2
*
2
43"
(1092 mm)
*29
1
/
2
"
(749 mm)
27"
(687 mm)
A
23¾"
(603 mm)
43"
(1092 mm)
27"
(687 mm)
*29
1
/
2
"
(749 mm)
13¾"
(349 mm)
B
A
B
C
18"*
(457 mm)
1"
(25 mm)
27"
(686 mm)
1"
(25 mm)
1"*
(25 mm)
14" max.*
(356
mm)
29
¼"
(743 mm)
5
½"*
(140 mm)
48 in.
(310 cm )
2
*
2
24 in.
(155 cm )
2
*
2
3"*
(76 mm)
3"*
(76 mm)
29" Wide Models
Dryer Dimensions
Installation Spacing
27" Wide Models
Dryer Dimensions
A. Large opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
A. Recessed area
B. Side view – closet or confined area
C. Closet door with vents
*Required spacing
Installation Spacing
Installation spacing for recessed area or closet
The dimensions shown are for the minimum spacing allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer
is recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
A. Large opening side-swing door
B. Large opening side-swing door
A. Recessed area
B. Side view – closet or confined area
C. Closet door with vents