- Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 1
English P1-P5945G/P2-P5945G ASUS PC (Desktop Barebone) Installation Manual Download the latest manual from the ASUS website: www.asus.com - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 2
port VGA port DVI-D port Serial port PCI slot metal brackets * The system's power supply unit has a 115 V/230 V voltage selector switch located near the power connector. Use this switch to select the correct system input voltage according to the voltage supply in your area. Installation manual - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 3
3.5 inch hard disk drive cage 2. Front panel cover 3. Power supply unit 4. PCI card riser bracket (connected to the motherboard PCI slot) 5. ASUS motherboard 6. DIMM sockets 7. LGA775 socket (under the CPU fan and heatsink assembly) 8. CPU fan and heatsink assembly Removing the cover 1. Remove the - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 4
cover, then set it aside. Removing the storage drive assembly 1. Lay the system on its side, then locate and remove three storage drive assembly screws. Removing the CPU fan and heatsink 1. Disconnect the CPU fan cable. 2. Loosen the CPU fan and heatsink assembly screws. 3. Lift the CPU fan and - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 5
fan and heatsink assembly, then reconnect the CPU fan cable to the CPU fan connector on the motherboard. Refer to the instructions in the previous section for details. Installing a DIMM 1. Locate the DIMM sockets in the motherboard. 2. Unlock a DIMM socket by pressing the retaining clips outward - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 6
card connector to the slot, then press the card firmly until it fits in place. Secure the card with a screw. 4. Reinstall the PCI riser card assembly. Make sure that the riser card connector sits properly on the motherboard then secure it with two screws on both sides. 2 3 Installation manual - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 7
reinstalling the storage drive assembly, connect the IDE/SATA and power plugs to the IDE/SATA and power connectors at the back of the drives. 1. Connect the black plug of the IDE cable to the optical drive, then direction of the rear panel until it disengages from the chassis. Installation manual - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 8
cover tabs fit the chassis rails. 2. Push the cover toward the front panel until it fits in place. 3. Secure the cover with two screws. 1 2 3 Installation manual - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 9
Français P1-P5945G/P2-P5945G ASUS PC (Système barebone) Manuel d'installation Téléchargez les derniers manuels depuis le site web d'ASUS: www.asus.com. - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 10
Caractéristiques de la façade Fermé Bouton d'ejection du lecteur optique LED HDD Capot de la baie du lecteur optique Appuyez pour ouvrir le capot de la façade Bouton d'alimentation LED d'alimentation Français Caractéristiques de la façade Ouvert Bouton Reset Slot pour cartes MS/MS Pro Slot pour - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 11
disque dur 3.5''. 2. Façade 3. Alimentation 4. Bracket du PCI Card Riser (connecté au slot PCI de la carte mère) 5. Carte mère ASUS 6. Sockets DIMM 7. Socket LGA775 (sous le système de refroidissement du CPU) 8. Système de refroidissement du CPU Enlever le capot 1. Enlevez les deux vis. Conservez - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 12
, puis mettez-le de côté. Retirez le dissipateur et le ventilateur du CPU 1. Déconnectez le câble de ventilation du CPU. 2. Retirez les vis de l'ensemble dissipateur/ventilateur du CPU. 3. Soulevez l'ensemble dissipateur/ventilateur du CPU, puis mettez-le de côté. Manuel d'installation - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 13
5. Réinstallez l'ensemble dissipateur/ventilateur du CPU, puis reconnectez le câble du ventilateur CPU au connecteur de la carte mère marqué CPU_FAN. Référez-vous aux instructions de la section précédente pour plus de détails. Installer un module DIMM 1. Localisez les sockets DIMM de la carte mère - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 14
et pressez jusqu'à ce que la carte soit en place. Sécurisez la carte avec une vis. 4. Réinstallez l'ensemble PCI Riser Card. Assurez-vous que le connecteur de la riser card soit bien connecté au slot PCI de la carte mère. Français Installer un lecteur optique ou de stockage 1. Placez l'ensemble - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 15
sur le châssis. 4. Sécurisez l'ensemble de stockage avec trois vis. 3 4 Installer le pied de support 1. Faites correspondre les crochets du pied de support aux ouvertures sur le châssis. 2. Tirez le pied de support dans la direction de la flèche jusqu'à ce qu'il soit bien en place. Pour - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 16
Français Réinstaller le capot de la façade 1. Insérez les onglets du capot 1 2 dans les ouvertures situées à droite du châssis, puis refermez-le. 2. Insérez les crochets du capot de la façade dans les onglets du châssis jusqu'à ce que le capot soit bien en place. Réinstaller le panneau 1. - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 17
繁體中文 P1-P5945G/P2-P5945G www.asus.com - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 18
外觀功能 I/O 外蓋 繁體中文 Reset 按鈕 MS/MS Pro CompactFlash SD/MMC card 麥克風 PS/2 滑鼠 PS/2 鍵盤 RJ-45 4-pin IEEE 1394 埠� USB 2.0 埠 耳機 麥克風 USB 2.0 埠� SPDIF VGA 埠� DVI-D 埠� 串列埠 PCI 100-127V 115V 200-240V 230V。 安裝手冊 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 19
繁體中文 內部組件 3 4 1 5 8 6 2 7 1. 5.25 3.5 5. 主機板 組支架 6. DIMM 插槽 2. 前面板 7. LGA775 CPU 3 下方) 4. PCI 8. CPU 風扇 PCI 插槽) 打開機殼 1 2 3 1 2 3 安裝手冊 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 20
1 1 2 扳開。 1 2 移除 CPU 風扇 1. 移除 CPU 3. 取出 CPU 2. 鬆 開 C P U 繁體中文 安裝手冊 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 21
安裝 CPU 1 90�-��1�0�0度�。� 2. 將��C�P�U CPU 固定扣 回定扳手 3 C�P�U C��P�U� �只 4 上。 繁體中文 5 C�P�U 1 2 3 DDR DIMM 安裝手冊 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 22
1. 將 PCI 2 3 4. 將 PCI PCI 插槽上。 繁體中文 1 2 3 2 3 安裝手冊 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 23
I�D�E�/�S�A�T�A 1. 請將 I D E SATA SATA 排線至 SATA 硬碟。 2. 連接 4-pin 3 4 3 4 安裝腳座 1 2 繁體中文 安裝手冊 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 24
1 1 2 上。 2 主機上 裝回機殼 1 2 3 1 2 3 繁體中文 安裝手冊 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 25
簡體中文 P1-P5945G/P2-P5945G www.asus.com - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 26
外觀功能 I/O 外蓋 簡體中文 Reset 按鈕 MS/MS Pro CompactFlash SD/MMC card 麥克風 PS/2 PS/2 鍵盤 RJ-45 4-pin IEEE 1394 USB 2.0 USB 2.0 SPDIF VGA DVI-D 串口 PCI 插槽 100-127V 115V 200-240V 230V。 安裝手冊 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 27
內部組件 3 4 1 5 8 6 2 7 1. 5.25 3.5 5. 主板 支架 6. DIMM 插槽 2. 前面板 7. LGA775 CPU 3 下方) 4. P C I 8. CPU 風扇 PCI 插槽) 1 2 3 1 2 3 簡體中文 安裝手冊 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 28
1 1 2 扳開。 1 2 去除 CPU 風扇 1. 去除 CPU 3. 取出 CPU 2. 鬆 開 C P U 簡體中文 安裝手冊 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 29
安裝 CPU 1 90�-��1�0�0度�。� 2 C�P�U CPU 固定扣 回定扳手 3 C�P�U C��P�U 4 簡體中文 5 C�P�U 1 2 3 DDR DIMM 凹槽 安裝手冊 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 30
1. 將 PCI 2 3 4. 將 PCI P���C��I 插槽上。 簡體中文 1 2 3 2 3 安裝手冊 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 31
I�D�E�/�S�A�T�A 1. 請將 IDE S�A�T�A SATA 2. 連接 4-pin 3 4 3 4 安裝腳座 1 2 簡體中文 安裝手冊 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 32
1 1 2 上。 2 主機上 1 2 3 1 2 3 簡體中文 安裝手冊 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 33
P1-P5945G/P2-P5945G ASUS PC ASUSのWeb www.asus.com. 日本語 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 34
HDD LED LED 日本語 MS/MS Pro CompactFlash SD/MMC L/R L/R PS/2 PS/2 LAN (RF-45) ポート 4ピン IEEE 1394 ポート USB 2.0 USB 2.0 ポート SPDIF VGA ポート DVI-D ポート PCI 115 V/230 V - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 35
3 4 1 5 8 6 2 7 1. 5.25 3.5インチHDDケージ 2 3 4. PCI PCI 5. ASUS 6. DIMM 7. LGA775 CPU 8. CPU 1 2 3 1 2 3 日本語 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 36
1 1 2 します。 2 1 2 CPU 1. CPU 3. CPU 2. CPU 日本語 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 37
CPU 1 2 3. CPU CPU 4 日本語 5. CPU CPU CPU DIMM 1 DIMM 2 DIMM 3. DIMM DIMM DDR DIMM の溝 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 38
1. PCI 2 4. PCI PCI 日本語 1 3.5 5.25 2 5.25 3. HDD 3.5 2 3 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 39
IDE / SATA 1. IDE HDD SA�T�A�H�D�D SA�T�A S�A�T�A�H�D 2. 4 3 4 3 4 1 2 日本語 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 40
1 1 2 す。 2 1 2 3 1 2 3 日本語 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 41
P1-P5945G/P2-P5945G ASUS PC www.asus.com 한국어 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 42
HDD LED 전원 LED MS/MS Pro CompactFlash SD/MMC L/R L/R MIC PS/2 PS/2 LAN (RJ-45) 포트 4핀 IEEE 1394 포트 USB 2.0 USB 2.0 포트 SPDIF VGA 포트 DVI-D 포트 PCI 115 V/230 V 한국어 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 43
3 4 1 5 8 6 2 7 1. 5.25 3.5 2 3 4. PCI 카드 riser PCI 5. ASUS 6. DIMM 소켓 7. LGA775 소켓 (CPU 8. CPU 1 2 3 1 2 3 한국어 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 44
1 1 2 2 1 3 2 CPU 1. CPU 2. CPU 3. CPU 한국어 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 45
CPU 설치 1 90°-100 2 PnP 3. CPU CPU 4 5. CPU CPU CPU DIMM 설치 1 DIMM 2 DIMM 3 DIMM DIMM DDR DIMM 노치 한국어 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 46
1. PCI 2 오. 3 4. PCI PCI 1. 5.25 3.5 2 5.25 3 3.5 2 3 한국어 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 47
IDE/SATA IDE/SATA 1. IDE SATA HDD SATA SATA HDD 2. 4 3 4 3 4 1 2 한국어 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 48
1 1 2 2 1 2 3 1 2 3 한국어 - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 49
Türkçe P1-P5945G/P2-P5945G ASUS PC Mini Masaüstü Bilgisayar) Kurulum Elkitabı ASUS web sitesinden en yeni kullan›m elkitab›n› indirin: www.asus.com. - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 50
-45) girifli 4-pimli IEEE 1394 portu USB 2.0 giriflleri Kulakl›k girifli Mikrofon girifli USB 2.0 giriflleri SPDIF Ç›k›fl portu VGA girifli DVI-D portu Seri girifl PCI yuvasu metal destekleri * Sistem güç besleme ünitesinde güç konektörünün yan›na yerlefltirilen 115 V/230 V de¤erinde voltaj seçme dü¤mesi - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 51
¤› 3. Güç beslemesi ünitesi 4. PCI kart› kald›rma deste¤i (anakart PCI yuvas›na ba¤lanm›flt›r) 5. ASUS anakart 6. DIMM soketleri 7. LGA775 soketi (CPU fan› ve ›s› alma komplesi alt›nda) 8. CPU fan› ve ›s› alma komplesi Kapa¤›n ç›kar›lmas› 1. Kapak vidalar›n› sökün. Vidalar› ileride kullanmak için - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 52
bulun ve ç›kar›n. 2. Saklama sürücü komplesini kald›r›n, ard›ndan kenara koyun. CPU fan›n›n ve ›s› al›c›n›n ç›kar›lmas› 1. CPU fan kablosunun 3. CPU fan›n› ve ›s› al›c› ba¤lant›s›n› kesin. komplesini kald›r›n, ard›ndan 2. CPU fan› ve ›s› al›c› komplesinin kenara koyun. vidalar›n› gevfletin - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 53
ard›ndan PnP flapkas›n› ç›kar›n. Tutma sekmesi Yük kolu 3. CPU'yu tak›n. CPU sadece bir yönde oturur. 4. Yük plakas›n› kapat›n, ard›ndan yük kolunu kilitleyin. 5. CPU fan›n› ve ›s› alma komplesini yeniden kurun, ard›ndan CPU fan kablosunu anakarttaki CPU fan konektörüne yeniden ba¤lay›n. Ayr›nt - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 54
Geniflletme kart›n›n tak›lmas› 1. Ç›karmak için PCI kald›rma kart› 2. Yuvan›n karfl›s›nda bulunan metal komplesini kald›r›n. kapa¤› ç›kar›n, böylece amaçland›¤› gibi kullanabilmelisiniz. Türkçe 3. Kart konektörünü yuvaya tak›n, ard›ndan yerine oturuncaya kadar karta düzgün bir flekilde bast›r›n. - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 55
Türkçe Saklama sürücüsü komplesinin yeniden kurulmas› Saklama sürücü komplesini yeniden kurmadan önce, IDE / SATA ve güç tapalar›n› IDE / SATA'ye ve güç konektörlerini sürücülerin arkas›na ba¤lay›n. 1. IDE kablosunun siyah renkteki fiflini optik sürücüye ba¤lay›n, ard›ndan gri renkteki fifli ise - Asus P2-P5945GC | P Series Installation manual for Multiple Languages - Page 56
Türkçe Ön panel kapa¤›n›n yeniden tak›lmas› 1. Ön panel kapa¤› sekmelerini 1 2 flasenin sa¤ taraf›ndaki deliklere yerlefltirin, ard›ndan kapa¤› kapat›n. 2. Ön panel kapa¤› çengellerini ön panel kapa¤› yerine oturuncaya kadar flase sekmelerine tak›n. Kapa¤›n yeniden tak›lmas› 1. Kapa¤› flaseye
English
P1-P5945G/P2-P5945G
ASUS PC (Desktop Barebone)
Installation Manual
Download the latest manual from the ASUS website: www.asus.com