Asus Z10PR-D16 User Guide

Asus Z10PR-D16 Manual

Asus Z10PR-D16 manual content summary:

  • Asus Z10PR-D16 | User Guide - Page 1
    Z10PR-D16
  • Asus Z10PR-D16 | User Guide - Page 2
    Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless such repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the product is defaced or missing. ASUS PROVIDES THIS MANUAL "AS IS" WITHOUT WARRANTY
  • Asus Z10PR-D16 | User Guide - Page 3
    notice ix How this guide is organized x Where to find more information x Z10PR-D16 specifications summary xii ASUS features 1-4 Chapter 2: Hardware Information 2.1 Before you proceed 2-2 2.2 Motherboard overview 2-3 2.2.1 Placement direction 2-3 2.2.2 Screw holes 2-3 2.2.3 Motherboard
  • Asus Z10PR-D16 | User Guide - Page 4
    the dual function power switch 3-3 Chapter 4: BIOS setup 4.1 Managing and updating your BIOS 4-2 4.1.1 ASUS CrashFree BIOS 3 utility 4-2 4.1.2 ASUS EZ Flash 2 Utility 4-3 4.1.3 BUPDATER utility 4-4 4.2 BIOS setup program 4-6 4.2.1 BIOS menu screen 4-7 4.2.2 Menu bar 4-7 4.2.3 Menu items
  • Asus Z10PR-D16 | User Guide - Page 5
    Miscellaneous Configuration 4-34 4.5.9 Server ME Configuration 4-34 4.5.10 Runtime Error Logging Support 4-34 4.6 Server Mgmt menu 4-35 4.7 Installing hard disk drives 5-3 5.1.3 Setting the RAID item in BIOS 5-3 5.1.4 RAID configuration utilities 5-3 5.2 LSI Software RAID Configuration
  • Asus Z10PR-D16 | User Guide - Page 6
    RAID 5-29 5.3.6 Setting the Boot array in the BIOS Setup Utility 5-31 5.4 Intel® Rapid Storage Technology driver 6-21 6.6 VGA driver installation 6-24 6.7 Intel® Rapid Storage Technology enterprise 4.0 installation 6-26 Appendix A: Reference Information A.1 Z10PR-D16 block diagram A-2 ASUS
  • Asus Z10PR-D16 | User Guide - Page 7
    frequency energy and, if not installed and used in accordance with manufacturer's instructions, may cause harmful interference to radio communications. However, there is no , we publish the chemical substances in our products at ASUS REACH website at http://csr.asus.com/english/REACH.htm. vii
  • Asus Z10PR-D16 | User Guide - Page 8
    service technician or your retailer. Operation safety • Before installing the motherboard and adding devices on it, carefully read all the manuals encounter technical problems with the product, contact a qualified service technician or your retailer. DO NOT throw the motherboard in municipal waste
  • Asus Z10PR-D16 | User Guide - Page 9
    Australian Consumer Law. For the latest product warranty details please visit http:// support.asus.com. Our goods come with guarantees that cannot be excluded under the failure. If you require assistance please call ASUS Customer Service 1300 2787 88 or visit us at http://support.asus.com ix
  • Asus Z10PR-D16 | User Guide - Page 10
    utilities. • Chapter 6: Driver installation This chapter provides instructions for installing the necessary drivers for different system components. • Appendix: Reference information This appendix includes additional information that you may refer to when configuring the motherboard. Where to find
  • Asus Z10PR-D16 | User Guide - Page 11
    of the following symbols used throughout this manual. DANGER/WARNING: Information to prevent injury to yourself when trying to complete a task. CAUTION: Information to prevent damage to the components when trying to complete a task IMPORTANT: Instructions that you MUST follow to complete a task
  • Asus Z10PR-D16 | User Guide - Page 12
    Z10PR-D16 specifications summary Model Name Z10PR-D16 Processor Support / System Bus Core Logic 2 x Socket R3 LGA 2011-3 Intel® Xeon® processor E5-2600 V3 product family QPI 6.4 / 8.0 / 9.6 GTps Intel® C610 PCH Form Factor SSI EEB, 12 in. x 13 in. Fan Speed Control ASUS to www.asus.com for
  • Asus Z10PR-D16 | User Guide - Page 13
    RJ-45 Intel® C610 Z10PR-D16 9 x SATA 6 Gbps ports (8 x 2 mini-SAS connector) 1 x discrete M.2 Intel® RSTe (for Windows only; supports software RAID 0, 1, 10, and 5) LSI® MegaRAID driver (support software RAID 0, 1, and 10) (Linux and Windows) Optional kits**: ASUS PIKE 3008 8-port SAS
  • Asus Z10PR-D16 | User Guide - Page 14
    xiv
  • Asus Z10PR-D16 | User Guide - Page 15
    Chapter 1: Product Introduction Product introduction This chapter describes the motherboard features and the new technologies it supports. 1
  • Asus Z10PR-D16 | User Guide - Page 16
    ! Congratulations and thank you for buying an ASUS® Z10PR-D16 motherboard! The motherboard delivers a host of new features and latest technologies, making it another standout in the long line of ASUS quality motherboards! Before you start installing the motherboard and hardware devices on it, check
  • Asus Z10PR-D16 | User Guide - Page 17
    serial number of the product, ASUS Technical Support team members can then offer a quicker and satisfying solution to your problems. Z10PR-D16 xxS2xxxxxxxx Made in China 合格 1.4 Special features 1.4.1 Product highlights Latest Processor Technology The motherboard supports Intel Xeon® processor E5
  • Asus Z10PR-D16 | User Guide - Page 18
    Intel® C610 Series Chipset The Intel® C610 series chipset supports with enterprise to the target users. Serial ATA III technology The motherboard supports the Serial ATA III technology through the Serial ATA . 1.4.2 Innovative ASUS features ASUS Fan Speed control technology The ASUS Fan Speed control
  • Asus Z10PR-D16 | User Guide - Page 19
    Chapter 2: Hardware Information Hardware Information This chapter lists the hardware setup procedures that you have to perform when installing system components. It includes description of the jumpers and connectors on the motherboard. 2
  • Asus Z10PR-D16 | User Guide - Page 20
    2.1 Before you proceed Take note of the following precautions before you install any motherboard component or change any motherboard settings. • Unplug the power cord from the wall socket before touching any component. • Use a grounded wrist strap or touch a safely grounded object or a metal object,
  • Asus Z10PR-D16 | User Guide - Page 21
    . Ensure to unplug the chassis power cord before installing or removing the motherboard. Failure to do so can cause you physical injury and damage motherboard components! 2.2.1 Placement direction When installing the motherboard, ensure that you place it into the chassis in the correct orientation
  • Asus Z10PR-D16 | User Guide - Page 22
    2.2.3 Motherboard layout 2-4 Chapter 2: Hardware information
  • Asus Z10PR-D16 | User Guide - Page 23
    2.2.4 Layout contents Slots/Sockets 1. CPU sockets 2. DDR4 sockets 3. PCI Express x16 / PCI Express x8 Page 2-7 2-12 2-16 Onboard LEDs 1. Standby Power LED (SBPWR1) 2. Baseboard Management Controller LED (BMCLED1) 3. CPU Warning LED (ERRCPU1, ERRCPU2) 4. Location LED (LOCLED1) 5. Memory error LED
  • Asus Z10PR-D16 | User Guide - Page 24
    Internal connectors 1. Serial ATA 6.0 / 3.0 Gbps connectors (7-pin SATA6 [Light Blue]) 2. Power Supply SMBus connector (5-pin PSUSMB1) 3. USB 2.0 connector (10-1 pin USB56, USB7) 4. USB 3.0 connector (20-1 pin USB3_34) 5. CPU, front, and rear fan connectors (4-pin CPU_FAN1, CPU_FAN2,
  • Asus Z10PR-D16 | User Guide - Page 25
    the cost of repair only if the damage is shipment/ transit-related. • Keep the cap after installing the motherboard. ASUS will process Return Merchandise Authorization (RMA) requests only if the motherboard comes with the cap on the LGA 2011 R3 socket. • The product warranty does not cover damage to
  • Asus Z10PR-D16 | User Guide - Page 26
    2. Press the left load lever down with your thumb (A), move it to the right until it is released from the retention tab (B) then gently lift the load lever (C). To prevent damage to the socket pins, do not remove the PnP cap unless you are installing a CPU. Load lever 3. Press the right load lever
  • Asus Z10PR-D16 | User Guide - Page 27
    4. Push the left load lever to slightly lift the load plate (G). Do not insert the load lever into the retention tab. edge of the Load plate 5. Hold the edge then gently lift the load plate (H). Load plate 6. Get the CPU. 7. Align and position the CPU over the socket ensuring that the triangle
  • Asus Z10PR-D16 | User Guide - Page 28
    out of the load plate when the right load lever is inserted into the retention tab. Keep the PnP cap. ASUS will process Return Merchandise Authorization (RMA) requests only if the motherboard comes with the PnP cap on the LGA 2011 socket. PnP cap 11. Push down the left load lever (L) then
  • Asus Z10PR-D16 | User Guide - Page 29
    or touches your skin, wash it off immediately, and seek professional medical help. 13. Connect the CPU fan cable to the connector on the motherboard labeled CPU_FAN1 / CPU_FAN2. DO NOT forget to connect the CPU fan connector! Hardware monitoring errors can occur if you fail to plug this connector
  • Asus Z10PR-D16 | User Guide - Page 30
    2.4 System memory 2.4.1 Overview The motherboard comes with sixteen (16) Double Data Rate 4 (DDR4 -DIMMs and NVDIMM into the DIMM sockets using the memory configurations in this section. • Refer to ASUS Server AVL for the updated list of compatible DIMMs. • When installing only one DIMM in a single
  • Asus Z10PR-D16 | User Guide - Page 31
    Single CPU configuration You can refer to the following recommended memory population for a single CPU configuration. Single CPU configuration (must be installed on CPU1) DIMM A2 A1 B2 B1 C2 C1 D2 D1 1 DIMM P 1 DIMM P 2 DIMMs P P 4 DIMMs P P P P 8 DIMMs P P P P P P P P
  • Asus Z10PR-D16 | User Guide - Page 32
    system components. Failure to do so may cause severe damage to both the motherboard and the components. 1. Unlock a DIMM socket by pressing the retaining clips to unlock the DIMM. 2. Remove the DIMM from the socket. Support the DIMM lightly with your fingers when pressing the retaining clips. The
  • Asus Z10PR-D16 | User Guide - Page 33
    if your motherboard is BIOS setup. 2. Assign an IRQ to the card. Refer to the table Standard Interrupt assignments in section Interrupt assignments for more information. 3. Install the software drivers for the expansion card. When using PCI cards on shared slots, ensure that the drivers support
  • Asus Z10PR-D16 | User Guide - Page 34
    for ISA or PCI devices. 2.5.4 PCI Express x16 slot (x16 link) The onboard PCIE6 provide one x16 Gen3 link to CPU1. This slot support VGA cards and various server class high performance add-on cards. 2.5.5 PCI Express x8 slot (x8 link) The onboard PCIE1 and PCIE2 provides two x8 Gen3 link to
  • Asus Z10PR-D16 | User Guide - Page 35
    No. (Slot location) Short description 1 PCIE1 PCI-E x8 (x8 Gen3 link) 2 PCIE2 PCI-E x8 (x8 Gen3 link) 3 PCIE3 PCI-E x16 (x16 Gen3 link) 2-17
  • Asus Z10PR-D16 | User Guide - Page 36
    shut down the system and unplug the power cable before removing or plugging in any motherboard component. The illustration below shows the location of the onboard LED. 2. Baseboard Management heartbeat LED functions only when you install the ASUS ASMB8. 2-18 Chapter 2: Hardware information
  • Asus Z10PR-D16 | User Guide - Page 37
    light up to indicate failure on either CPU1, CPU2, or both. 4. Location LED (LOCLED1) This onboard LED lights up when the Location button on the server is pressed or when triggered by a system management software. The Location LED helps visually locate and quickly identify the
  • Asus Z10PR-D16 | User Guide - Page 38
    , MEMERRH2) The DIMM warning LEDs light up to indicate failure on the corresponding DIMMs. The warning LEDs only functions when you enable the ASUS ASMB8. 6. CATT LED (CATTERR_LED1) The CATT LED indicates that the system has experienced a fatal or catastrophic error and cannot continue to operate
  • Asus Z10PR-D16 | User Guide - Page 39
    7. Message LED (MESLED1) This onboard LED lights up to red when there is temperature warning or a BMC event log is generated. 8. OCPLAN Activity LED connector (4-pin OCP_LED1) OCPLAN LED connector supports ASUS MCB-10G-2S OCP card Active LED. 2-21
  • Asus Z10PR-D16 | User Guide - Page 40
    the cap back to pins 1-2. 3. Plug the power cord and turn ON the computer. 4. Hold down the key during the boot process and enter BIOS setup to reenter data. DO NOT remove the cap on CLRTC jumper default position except when clearing the RTC RAM. Removing the cap will cause
  • Asus Z10PR-D16 | User Guide - Page 41
    2. VGA controller setting (3-pin VGA_SW1) This jumper allows you to enable or disable the onboard VGA controller. Set to pins 1-2 to activate the VGA feature. 3. LAN controller setting (3-pin LAN_SW1, LAN_SW2) These jumpers allow you to enable or disable the onboard LAN_SW1 or LAN_SW2. Set to pins
  • Asus Z10PR-D16 | User Guide - Page 42
    4. ME firmware force recovery setting (3-pin ME_RCVR1) This jumper allows you to force Intel® Management Engine (ME) boot from recovery mode when ME becomes corrupted. 5. DDR4 thermal event setting (3-pin DIMMTRIP1) This jumper allows you to enable or disable DDR4 DIMM thermal sensing event pin. 2-
  • Asus Z10PR-D16 | User Guide - Page 43
    6. RAID configuration utility selection (3-pin RAID_SEL1) This jumper allows you to select the RAID configuration utility to use when you create disk arrays. Place the jumper caps over pins 1-2 to use the third party software LSI MegaRAID software RAID Configuration Utility; otherwise, place the
  • Asus Z10PR-D16 | User Guide - Page 44
    2.8 Connectors 2.8.1 Rear panel connectors 1. RJ-45 ports for LAN. These ports allows Gigabit connection to a LAN through a network hub. Refer to the LAN port LED indications table for more information. 2. PS/2 keyboard/mouse port (purple/green). This port is for a PS/2 keyboard or mouse. 3. RJ-45
  • Asus Z10PR-D16 | User Guide - Page 45
    Q-Code table Action Normal boot PHASE Security Phase PEI(Pre-EFI initialization) phase POST CODE 01 02 03 06 04 10 15 19 78~00 A1 A3 A7 A8 A9 AA AB AC AD AE AF 2F B0 B1 AF B4 B2 B3 B5 B6 B7 B8 B9 BA BB BC BF 5A 31 32 34 36 4F TYPE Progress Progress Progress Progress Progress Progress Progress
  • Asus Z10PR-D16 | User Guide - Page 46
    . AMI USB Driver Init. AMI USB Driver Init. AMI USB Driver Init. Legacy Option ROM Init. Reset system USB hotplug NVRAM clean up NVRAM configuration reset IDE, AHCI Init. IDE, AHCI Init. IDE, AHCI Init. IDE, AHCI Init. BIOS Setup Utility password verify BIOS Setup Utility start BIOS Setup Utility
  • Asus Z10PR-D16 | User Guide - Page 47
    2.8.2 Internal connectors 1. Serial ATA 6.0 Gbps connector (7-pin SATA6 [Light Blue]) Supported by the Intel® 610 series Chipset, this connector is for the Serial ATA signal cables for Serial ATA hard using the SMBus interface. This connector functions only when you install the ASUS ASMB8. 2-29
  • Asus Z10PR-D16 | User Guide - Page 48
    connectors are for USB 2.0 ports. Connect the USB module cables to connectors USB56. These USB connectors comply with USB 2.0 specification that supports up to 480 Mb/s connection speed. 4. USB 3.0 connector (20-1 pin USB3_34) This connector allows you to connect a USB 3.0 module for additional
  • Asus Z10PR-D16 | User Guide - Page 49
    REAR_FAN2) The fan connectors support cooling fans. Connect the fan cables to the fan connectors on the motherboard, ensuring that the black wire damage the motherboard components. • These are not jumpers! DO NOT place jumper caps on the fan connectors! • All fans feature the ASUS Smart Fan
  • Asus Z10PR-D16 | User Guide - Page 50
    the module to a slot opening at the back of the system chassis. 8. Trusted Platform Module connector (20-1 pin TPM1) This connector supports a Trusted Platform Module (TPM) system, which can securely store keys, digital certificates, passwords, and data. A TPM system also helps enhance network
  • Asus Z10PR-D16 | User Guide - Page 51
    recommended when configuring a system with more power-consuming devices. The system may become unstable or may not boot up if the power is inadequate. • This motherboard supports ATX2.0 PSU or later version. • Ensure that your PSU can provide at least the minimum power required by your system. 2-33
  • Asus Z10PR-D16 | User Guide - Page 52
    System panel connector (20-1 pin PANEL1) This connector supports several chassis-mounted functions. 1. System power LED turns the system on or puts the system in sleep or soft-off mode depending on the BIOS settings. Pressing the power switch for more than four seconds while the system is ON turns
  • Asus Z10PR-D16 | User Guide - Page 53
    11. Auxiliary panel connector (20-2 pin AUX_PANEL1) This connector is for additional front panel features including front panel SMB, locator LED and switch, chassis intrusion, and LAN LEDs. 1. Front panel SMB (10-2 pin FPSMB) These connectors are for the front panel SMBus cable. 2. LAN activity LED
  • Asus Z10PR-D16 | User Guide - Page 54
    12. VGA connector (10-1 pin VGA_HDR1) This connector supports the VGA High Dynamic-Range interface. 13. Hard disk activity LED connector (4-pin HDLED1) This LED connector is for the storage add-on card cable
  • Asus Z10PR-D16 | User Guide - Page 55
    default setting is short CASEOPEN and GND pin by jumper cap to disable the function. 15. ISATA & ISSATA connectors (ISATA; ISSATA) The ISATA connector (AHCI) supports 4 SATA 6Gb/s ports and Intel RAID/LSI MegaRAID. The ISSATA connector (AHCI
  • Asus Z10PR-D16 | User Guide - Page 56
    connector allows you to install an M.2 device. This connector supports type 2242 devices on both PCI-E and SATA interface. The M.2 (NGFF) device is purchased separately 17. Mezzanine PCI card connector (MEZZ1) The MEZZ1 connector supports Open Compute Project (OCP) cards. 2-38 Chapter 2: Hardware
  • Asus Z10PR-D16 | User Guide - Page 57
    Chapter 3: Powering Up Powering Up This chapter describes the power up sequence, and ways of shutting down the system. 3
  • Asus Z10PR-D16 | User Guide - Page 58
    the power-on self-test or POST. While the tests are running, the BIOS beeps or additional messages appear on the screen. If you do not see anything . Chassis Intrusion. BIOS-image Crash Detected. 7. At power on, hold down the key to enter the BIOS Setup. Follow the instructions in Chapter 4.
  • Asus Z10PR-D16 | User Guide - Page 59
    check box is checked. 4. If necessary, key in comments. 5. Click OK. Using Windows® Server 2012: 1. Press ++. 2. Click on the Power icon on the lower right side or to soft-off mode, depending on the BIOS setting. Pressing the power switch for more than four seconds lets the system
  • Asus Z10PR-D16 | User Guide - Page 60
    3-4 Chapter 3: Powering up
  • Asus Z10PR-D16 | User Guide - Page 61
    Chapter 4: BIOS setup BIOS setup This chapter tells how to change the system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided. 4
  • Asus Z10PR-D16 | User Guide - Page 62
    disk drive in case you need to restore the BIOS in the future. Copy the original motherboard BIOS using the BUPDATER utility. 4.1.1 ASUS CrashFree BIOS 3 utility The ASUS CrashFree BIOS 3 is an auto recovery tool that allows you to restore the BIOS file when it fails or gets corrupted during the
  • Asus Z10PR-D16 | User Guide - Page 63
    EZ Flash 2 Utility. Press . ASUS Tek. EzFlash Utility Current Platform Platform : Z10PR-D16 Version : 0020 Build Date :04/25/2014 New Platform Platform : Z10PR-D16 Version : 0022 Build Date :05/05/2014 FS0 System Volume Information Z10PR-D16 BIOS Windows [Up/Down
  • Asus Z10PR-D16 | User Guide - Page 64
    using the BUPDATER utility: 1. Visit the ASUS website at www.asus.com and download the latest BIOS file for the motherboard. Save the BIOS file to a bootable USB flash disk drive. 2. Copy the BUPDATER utility (BUPDATER.exe) from the ASUS support website at support.asus.com to the bootable USB flash
  • Asus Z10PR-D16 | User Guide - Page 65
    (11/08/04) FLASH TYPE: KALEL 05MAR12 Current ROM BOARD: Z10PR-D16 VER: 0301 DATE: 04/30/2014 Update ROM BOARD: Z10PR-D16 VER: 0303 DATE: 05/09/2014 PATH: Note Writing BIOS: DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure! 5. The utility returns to the
  • Asus Z10PR-D16 | User Guide - Page 66
    setup program This motherboard supports a programmable firmware chip that you can update using the provided utility described in section 5.1 Managing and updating your BIOS. Use the BIOS Setup program when you are installing a motherboard, reconfiguring your system, or prompted to "Run Setup." This
  • Asus Z10PR-D16 | User Guide - Page 67
    4.2.1 BIOS menu screen Menu items Menu bar Configuration fields General help Navigation keys changing the advanced system settings IntelRCSetup For changing the Intel RC settings Server Mgmt For changing the Server Mgmt settings Event Logs For changing the event log settings Monitor 
  • Asus Z10PR-D16 | User Guide - Page 68
    the submenu, select the item then press . 4.2.5 Navigation keys At the bottom right corner of a menu screen are the navigation keys for the BIOS setup program. Use the navigation keys to select items in the menu and change the settings. 4.2.6 General help At the top right corner of the
  • Asus Z10PR-D16 | User Guide - Page 69
    4.3 Main menu When you enter the BIOS Setup program, the Main menu screen appears. The Main menu provides you an overview of the basic system information, and allows you to set the
  • Asus Z10PR-D16 | User Guide - Page 70
    4.4 Advanced menu The Advanced menu items allow you to change the settings for the CPU and other system devices. Take caution when changing the settings of the Advanced menu items. Incorrect field values can cause the system to malfunction. 4-10 Chapter 4: BIOS setup
  • Asus Z10PR-D16 | User Guide - Page 71
    4.4.1 ACPI Settings Enable ACPI Auto Configuration [Disabled] Allows you to enable or disable the BIOS ACPI Auto Configuration. Configuration options: [Disabled] [Enabled] Enable Hibernation [Enabled] Allows you to enable or disable the ability of the system to hibernate (OS/Sleep
  • Asus Z10PR-D16 | User Guide - Page 72
    =3F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12;] [IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12;] [IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12;] [IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12;] 4-12 Chapter 4: BIOS setup
  • Asus Z10PR-D16 | User Guide - Page 73
    4.4.4 Intel LAN I210 Configuration Intel I210 Lan1 Enable/ Intel I210 Lan2 Enable [Enabled] Allows you to enable or disable the Intel LAN. Configuration options: [Disabled] [Enabled] Intel LAN ROM Type [PXE] Allows you to select the Intel LAN ROM type. Configuration options: [Disabled] [PXE] [iSCSI]
  • Asus Z10PR-D16 | User Guide - Page 74
    [VT-UTF8] Allows you to set the terminal type. [VT100] ASCII char set. [VT100+] Extends VT100 to support color, function keys, et. [VT-UTF8] Uses UTF8 encoding to map Unicode chars onto 1 or more bytes [Mark] parity bit is always 1 [Space] parity bit is always 0 4-14 Chapter 4: BIOS setup
  • Asus Z10PR-D16 | User Guide - Page 75
    allows you to set the number of rows and columns supported on the Legacy OS. Configuration options: [80x24] [ ] [SCO] [ESCN] [VT400] Redirection After BIOS POST [Always Enable] This setting allows you to -Band Management/ Windows Emergency Management Services (EMS) Console Redirection [Disabled]
  • Asus Z10PR-D16 | User Guide - Page 76
    Windows Emergency Management Services (EMS) allow for remote management of a Windows Server OS through Emergency Management Services (EMS) allow for remote management of a Windows Server OS through Emergency Management Services (EMS) allow for remote management of a Windows Server OS through
  • Asus Z10PR-D16 | User Guide - Page 77
    4.4.6 APM Restore AC Power Loss [Last State] When set to [Power Off], the system goes into off state after an AC power loss. When set to [Power On], the system will reboot after an AC power loss. When set to [Last State], the system goes into either off or on state, whatever the system state was
  • Asus Z10PR-D16 | User Guide - Page 78
    decoded in above 4G address space. It only works if the system supports 64-bit PCI decoding. Configuration options: [Disabled] [Enabled] SR-IOV Support [Disabled] This option enables or disables SIngle Root IO Virtualization Support if the system has SRIOV capable PCIe devices. Configuration options
  • Asus Z10PR-D16 | User Guide - Page 79
    . Configuration options: [Disable] [Enable] The following item appears only when Network stack is set to [Enabled]. Ipv4 PXE Support [Enabled] Enables or disables the Ipv4 PXE Boot Support. If disabled, Ipv4 PXE boot option will not be created. Configuration options: [Disabled] [Enabled]. Ipv6 PXE
  • Asus Z10PR-D16 | User Guide - Page 80
    ] This option allows you to enable or disable CSM Support. Configuration options: [Disabled] [Enabled] GateA20 Active [Upon Request] This allows you to set the GA20 option. Configuration options: [Upon Request] [Always] Option ROM Messages [Force BIOS] This allows you to set the display mode for
  • Asus Z10PR-D16 | User Guide - Page 81
    4.4.10 Trusted Computing Configuration Security Device Support [Disabled] Allows you to enable or disable the BIOS support for security device. Configuration options: [Disabled] [Enabled] 4-21
  • Asus Z10PR-D16 | User Guide - Page 82
    Enabled] EHCI Hand-off [Disabled] This is a workaround for 0Ses without EHCI hand-off support. The EHCI ownership change should be claimed by EHCI driver. Configuration options: [Disabled] [Enabled] USB Mass Storage Driver Support [Enabled] Allows you to enable or disable the USB Mass Storage drvier
  • Asus Z10PR-D16 | User Guide - Page 83
    power-up delay [Auto] This is the maximum time the device will take before it properly reports itself to the host controller. Configuration options: [Auto] [Manual] 4.4.12 iSCSI Configuration Allows you to configure the iSCSi parameters. 4-23
  • Asus Z10PR-D16 | User Guide - Page 84
    4.5 IntelRCSetup menu 4-24 Chapter 4: BIOS setup
  • Asus Z10PR-D16 | User Guide - Page 85
    ] [Enabled] Execute Disable Bit [Enabled] XD can prevent certain classes of malicious buffer overflow attacks when combined with a supporting OS (Windows Server 2003 SP1, Windows XP SP2, SuSE Linux 9.2, Redhat Enterprise 3 Update 3). Configuration options: [Disabled] [Enabled] Enable Intel TXT
  • Asus Z10PR-D16 | User Guide - Page 86
    Enabled] This Item allows you to enable or disable the extended APIC support. Configuration options: [Disabled] [Enabled] AES-NI [Enabled] This Item allows you to enable or disable the AES-NI support. Configuration options: [Disabled] [Enabled] Down Stream PECI
  • Asus Z10PR-D16 | User Guide - Page 87
    TDP. Configuration options: [Disabled] [Enabled] CPU Advanced PM Turning Energy Perf BIAS Energy Performance Tuning [Disabled] Selects whether BIOS or Operating System chooses energy performance bias turning. Configuration options: [Disabled] [Enabled] Energy Performance BIAS setting [Balanced
  • Asus Z10PR-D16 | User Guide - Page 88
    QPI link frequency Configuration options: [Auto] [6.4 GT/s] [8.0 GT/s] [9.6 GT/s] QPI Link0p [Enable] Configuration options: [Disable] [Enable] QPI Link1 [Enable] Configuration options: [Disable] [Enable] 4-28 Chapter 4: BIOS setup
  • Asus Z10PR-D16 | User Guide - Page 89
    [Enabled] Allows you to enable or disable halt on mem Training Error. Configuration options: [Disabled] [Enabled] ECC Support [Auto] Allows you to enable or disable the ECC support. Configuration options: [Auto] [Disabled] [Enabled] Data Scrambling [Auto] Allows you to enable/disable data scrambling
  • Asus Z10PR-D16 | User Guide - Page 90
    Options CK in SR [Auto] Configuration options: [Auto] [Driver] [Tri-State] [Pulled Low] Pulled High] MDLL enable or disable RAS Modes. Enabling Sparing and Mirroring is not supported. In case enabled, Sparing will be selected. Configuration options: [ Disabled] [Enabled] 4-30 Chapter 4: BIOS setup
  • Asus Z10PR-D16 | User Guide - Page 91
    Global Options TX EQ WA [Enabled] Use special table for TX_EQ and vendor specific cards. Configuration options: [Disabled] [Enabled] PCI-E ASPM Support (Global) [L1 Only] This option enables or disables the ASPM support for all downstream devices. Configuration options: [Disabled] [L1 Only] 4-31
  • Asus Z10PR-D16 | User Guide - Page 92
    If enabled, LED/SGPIO hardware is attached. Configuration options: [Disabled] [Enabled] Support Aggressive Link Power Management [Enabled] Allows you to enable or disable the Suport Allows you to enable or disable the SATA port Configuration options: [Disabled] [Enabled] 4-32 Chapter 4: BIOS setup
  • Asus Z10PR-D16 | User Guide - Page 93
    ] [RAID] SATA Mode options SATA LED locate [Enabled] If enabled, LED/SGPIO hardware is attached. Configuration options: [Disabled] [Enabled] Support Aggressive Link Power Management [Enabled] Allows you to enable or disable the Suport Aggressive Link Power (SALP) Management. Configuration options
  • Asus Z10PR-D16 | User Guide - Page 94
    select the video type. Configuration options: [Onboard Device] [Offboard Device] 4.5.9 Server ME Configuration Displays the Server ME Technology parameters on your system. 4.5.10 Runtime Error Logging Support Runtime Error Logging Whea Support [Disabled] This item allows you to enable or disable the
  • Asus Z10PR-D16 | User Guide - Page 95
    4.6 Server Mgmt menu OS Watchdog Timer [Disabled] This item allows you to start a BIOS timer which can only be shut off by Intel Management Software after the OS loads. Configuration options: [Disabled] [Enabled] The following items is configurable only
  • Asus Z10PR-D16 | User Guide - Page 96
    State] This item allows you to configure LAN channel parameters statistically or dynamically (by BIOS or BMC). Unspecified option will not modify any BMC network parameters during BIOS phase. Configuration options: [Previous State] [Static] [DynamicBmcDhcp] [DynamicBmcNonDhcp] 4-36 Chapter
  • Asus Z10PR-D16 | User Guide - Page 97
    allows you to enable or disable the IPv6 BMC LAN channel function. Disabling this item will not modify any BMC network during BIOS phase. Configuration options: [Disable] [Enable] IPv6 BMC LAN IP Address source [Previous State] Select to configure LAN channel parameters statically or dynamically
  • Asus Z10PR-D16 | User Guide - Page 98
    channel function. Disabling this option will not modify any BMC network during BIOS phase. The following item appears only when you set IP BMC Lan State] Select to configure LAN channel parameters statically or dynamically(by BIOS or BMC). Configuration options: [Previous State] [Static] [Dynamic-
  • Asus Z10PR-D16 | User Guide - Page 99
    IPv6 BMC LAN Default Gateway Allows you to input IPv6 BMC Lan Default Gateway. IPv6 BMC LAN DNS Settings Allows you to enter IPv6 BMC LAN DNS Settings. IPv6 BMC LAN Link IP Address Allows you to enter IPv6 BMC LAN Link IP address. IPv6 BMC LAN Link IP Prefix Length Allows you to input IPv6 BMC Lan
  • Asus Z10PR-D16 | User Guide - Page 100
    Smbios Types (Not all may be translated). Configuration options: [Disabled] [Enabled] 4.7.2 View Smbios Event Log Press to view all smbios event logs. 4-40 Chapter 4: BIOS setup
  • Asus Z10PR-D16 | User Guide - Page 101
    automatically detects and displays the CPU and motherboard component temperatures. CPU FAN1/2 Speed; rotations per minute (RPM). If the fan is not connected to the motherboard, the field shows N/A. +VCCIO, VCORE1/2 Voltage, +VDDQ_AB/CD/ Allows you to configure the ASUS Smart Fan feature that smartly
  • Asus Z10PR-D16 | User Guide - Page 102
    the administrator password, follow the same steps as in changing an administrator password, but press when prompted to create/confirm the password. 4-42 Chapter 4: BIOS setup
  • Asus Z10PR-D16 | User Guide - Page 103
    User Password To set a user password: 1. Select the User Password item and press . 2. From the Create New Password box, key in a password, then press . 3. Confirm the password when prompted. To change a user password: 1. Select the User Password item and press . 2. From the
  • Asus Z10PR-D16 | User Guide - Page 104
    Key (KEK)/ Authorized Signatures (DB)/ Authorized TimeStamps (DBT)/ Forbidden Signatures (DBX) Configuration options: [Delete] [Set New] [Append] Configuration options: [Set New] [Delete] [Append] 4-44 Chapter 4: BIOS setup
  • Asus Z10PR-D16 | User Guide - Page 105
    4.10 Boot menu The Boot menu items allow you to change the system boot options. Setup Prompt Timeout [xx] Use the and keys to adjust the number of seconds to wait for setup activation key. Bootup NumLock State [On] Allows you to select the power-on state for the NumLock. Configuration
  • Asus Z10PR-D16 | User Guide - Page 106
    Tool menu The Tool menu items allow you to configure options for special functions. Select an item then press to display the submenu. ASUS EZ Flash Allows you to run ASUS EZ Flash BIOS ROM Utility when you press . Refer to the ASUS EZ Flash Utility section for details. 4-46 Chapter
  • Asus Z10PR-D16 | User Guide - Page 107
    4.12 Exit menu The Exit menu items allow you to save or discard your changes to the BIOS items. Pressing does not immediately exit this menu. Select one of the options from this menu or from the legend bar to exit.
  • Asus Z10PR-D16 | User Guide - Page 108
    selected device. Launch EFI Shell from filesystem device Attempts to launch EFI Shell application (shellx64.efi) from one of the available filesystem devices. 4-48 Chapter 4: BIOS setup
  • Asus Z10PR-D16 | User Guide - Page 109
    Chapter 5: RAID Configuration RAID Configuration This chapter provides instructions for setting up, creating, and configuring RAID sets using the available utilities. 5
  • Asus Z10PR-D16 | User Guide - Page 110
    motherboard supports the following SATA RAID solutions: • LSI MegaRAID software RAID Configuration Utility with RAID 0, RAID 1, and RAID 10 support disk drive included in a created RAID set, copy first the RAID driver from the support DVD to a floppy disk before you install an operating system to the
  • Asus Z10PR-D16 | User Guide - Page 111
    instructions in the system user guide. 2. Connect a SATA signal cable to the signal connector at the back of each drive and to the SATA connector on the motherboard disk drives attached to the SATA connectors supported by Intel® C602 chipset. To do this: 1. Enter the BIOS Setup during POST. 2. Go to
  • Asus Z10PR-D16 | User Guide - Page 112
    drives connected to the SATA connectors supported by the motherboard southbridge chip. To enter the to enter the utility. LSI MegaRAID Software RAID BIOS Version A.10 09231523R LSI SATA RAID Found at of the SATA optical drive has to be manually adjusted. Otherwise, the system will not boot
  • Asus Z10PR-D16 | User Guide - Page 113
    , the virtual drive parameters are set automatically. In New Configuration, you manually set the virtual drive parameters. Using Easy Configuration To create a RAID set Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Configuration Menu Easy Configuration
  • Asus Z10PR-D16 | User Guide - Page 114
    ONLIN A[X]-[Y], where X is the array number, and Y is the drive number. LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Easy Configuration - ARRAY SELECTION MENU Management Menu Configure PORT # Initialize Objects 0 ONLIN A00-00 Rebuild 1 ONLIN A00-01
  • Asus Z10PR-D16 | User Guide - Page 115
    to change the virtual drive parameters. LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Virtual Drive(s) Configured ManagemeLnDt MenuERaAsIyD ConfSigzueration -#SAtRrRiApYesSELECTSItOrNipMSEzNU CIonniftiigaulriez0e Objects 1 148.580GB PORT #2 0 ONLIN
  • Asus Z10PR-D16 | User Guide - Page 116
    from the menu, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Virtual Drive(s) Configured ManagemeLnDt MenuERaAsIyD ConfSigzueration -#SAtRrRiApYesSELECTSItOrNipMSEzNU Status CIonniftiigaulriez0e 1 148.580GB PORT #2 0 ONLIN A00
  • Asus Z10PR-D16 | User Guide - Page 117
    Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Virtual Drive(s) Configured ManagemeLnDt MenuERaAsIyD LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Management Menu Configure Configuration Menu Easy Configuration New
  • Asus Z10PR-D16 | User Guide - Page 118
    Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Configuration Menu Easy Configuration Management MenuNew Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Virtual Drive(s) Configured ManagemeLnDt MenuERaAsIyD
  • Asus Z10PR-D16 | User Guide - Page 119
    ONLIN A[X]-[Y], where X is the array number, and Y is the drive number. LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R View/Add Configuration - ARRAY SELECTION MENU Management Menu Configure PORT # Initialize Objects 0 ONLIN A00-00 Rebuild 1 ONLIN A00
  • Asus Z10PR-D16 | User Guide - Page 120
    From the Management Menu, select Initialize, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency Initialize VD(s) Use Cursor Keys to Navigate Between Items And Press
  • Asus Z10PR-D16 | User Guide - Page 121
    Esc> to abort initialization. When initialization is completed, press . LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency Virtual Drive(s) Configured LD RAID Size #Stripes StripSz
  • Asus Z10PR-D16 | User Guide - Page 122
    Menu, select Objects > Virtual Drive, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Objects Management MAednaupter Configure Virtual Drive Initialize Physical Drive Objects Rebuild Check Consistency Change VD Parameters Use
  • Asus Z10PR-D16 | User Guide - Page 123
    -up menu, and then press to start initialization. LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Objects Management MAednaupter Configure Virtual Drive Virtual Drive(1) Virtual Drive 0 Initialize Physical Drive Objects Rebuild Virtual Drive
  • Asus Z10PR-D16 | User Guide - Page 124
    drives You can manually rebuild failed hard disk drives using the Rebuild command in the Management Menu. To rebuild a failed hard disk drive 1. From the Management Menu, select Rebuild, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R
  • Asus Z10PR-D16 | User Guide - Page 125
    to rebuild, press . When prompted, press to rebuild the drive. LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Management MenuREBUILD - PHYSICAL DRIVES SELECTION MENU Configure PORT # Initialize Objects 0 ONLIN A00-00 Rebuild 1 FAIL A00-01
  • Asus Z10PR-D16 | User Guide - Page 126
    From the Management Menu, select Check Consistency, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency CC of VD(s) Use Cursor Keys to Navigate Between Items And Press
  • Asus Z10PR-D16 | User Guide - Page 127
    Yes from the Consistency Check? dialog box, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R LD Management Menu Configure 0 Initialize Objects Rebuild Check Consistency Virtual Drive(s) Configured ERaAsIyD ConfSigzueration
  • Asus Z10PR-D16 | User Guide - Page 128
    Using the Objects command To check data consistency using the Objects command 1. From the Management Menu, select Objects, and then select Virtual Drive from the sub-menu. 2. Use the arrow keys to select the virtual drive you want to check, and then press . 3. Select Check Consistency from
  • Asus Z10PR-D16 | User Guide - Page 129
    Configuration? dialog box, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Configuration Menu Easy Configuration Management MenuNew Configuration Configure View/Add Configuration Initialize Clear ConfCilgeuraartiCoonnfiguration
  • Asus Z10PR-D16 | User Guide - Page 130
    Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Configuration Menu Easy Configuration Management MenuNew LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Configuration BMoeontuable VDs(1): Current Boot VD(0)
  • Asus Z10PR-D16 | User Guide - Page 131
    5.2.8 Enabling WriteCache You may manually enable the RAID controller's WriteCache option after creating a Rate Disk WC = = = = = 30 30 30 30 Off Rebuild Check Consistency Read Ahead = On Bios State = Enable Cont On Error = Yes Fast Init = Enable Auto Rebuild = On Auto Resume = Enable
  • Asus Z10PR-D16 | User Guide - Page 132
    that are connected to the Serial ATA connectors supported by the Southbridge. Before you proceed, ensure that you have installed the Serial ATA hard disk drives, have set the correct jumper settings of the motherboard, and have set the correct SATA mode in the BIOS setup. You can refer to sections
  • Asus Z10PR-D16 | User Guide - Page 133
    5.3.1 Creating a RAID set To create a RAID set: 1. From the utility main menu, select 1. Create RAID Volume and press . 2. Key in a name for the RAID set and press . Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023 Copyright(C) 2003-12 Intel Corporation. All
  • Asus Z10PR-D16 | User Guide - Page 134
    range from 4 KB to 128 KB. The following are typical values: RAID 0: 128KB RAID 10: 64KB RAID 5: 64KB We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for audio and video editing. 7. In the Capacity field item, key in the RAID
  • Asus Z10PR-D16 | User Guide - Page 135
    5.3.2 Deleting a RAID set Take caution when deleting a RAID set. You will lose all data on the hard disk drives when you delete a RAID set. To delete a RAID set: 1. From the utility main menu, select 2. Delete RAID Volume and press . 2. From the Delete Volume Menu, press the up/down arrow
  • Asus Z10PR-D16 | User Guide - Page 136
    5.3.3 Resetting disks to Non-RAID Take caution before you reset a RAID volume hard disk drive to non-RAID. Resetting a RAID volume hard disk drive deletes all internal RAID structure on the drive. To reset a RAID set: 1. From the utility main menu, select 3. Reset Disks to Non-RAID and press <
  • Asus Z10PR-D16 | User Guide - Page 137
    5.3.4 Exiting the Intel® Rapid Storage Technology enterprise SATA Option ROM utility To exit the utility: 1. From the utility main menu, select 4. Exit then press . 2. Press to exit or press to return to the utility main menu. [ CONFIRM EXIT ] Are you sure you want to exit? (Y/N):
  • Asus Z10PR-D16 | User Guide - Page 138
    3. The utility immediately starts rebuilding after the disk is selected. When done, the status of the degraded RAID volume is changed to "Rebuild". Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023 Copyright(C) 2003-12 Intel Corporation. All Rights Reserved. [ MAIN MENU ]
  • Asus Z10PR-D16 | User Guide - Page 139
    at least one of the arrays bootable to boot from the hard disk. 1. Reboot the system and press to enter the BIOS setup utility during POST. 2. Go to the Boot menu and select the boot option priority. 3. Use up/down arrow keys to select the boot priority
  • Asus Z10PR-D16 | User Guide - Page 140
    disk drives that are connected to the Serial ATA connectors supported by the Southbridge. You need to manually install the Intel® Rapid Storage Technology enterprise utility on a Windows® operating system. Please refer to the installation instructions in Chapter 6. To enter the Intel® Rapid Storage
  • Asus Z10PR-D16 | User Guide - Page 141
    5.4.1 Creating a RAID set To create a RAID set: 1. From the utility main menu, select Create Volume and select volume type. 2. Click Next. 3. Enter a name for the RAID set, then select the array disks. 4. Select Volume Size tab, you can drag the bar to decide the volume size. 5. Click Next. • If you
  • Asus Z10PR-D16 | User Guide - Page 142
    6. Confirm the volume creation, than click Create Volume to continue. This process could take a while depending on the number and size of the disks. You can continue using other applications during this time. 7. Wait until the process is completed, then click OK when prompted. You still need to
  • Asus Z10PR-D16 | User Guide - Page 143
    values range from 4 KB to 128 KB. The following are typical values: RAID 0: 128KB RAID 10: 64KB RAID 5: 64KB We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for audio and video editing. 5-35
  • Asus Z10PR-D16 | User Guide - Page 144
    5.4.3 Deleting a volume Be cautious when deleting a volume. You will lose all data on the hard disk drives.Before you proceed, ensure that you back up all your important data from your hard drives. To delete a volume: 1. From the utility main menu, select the volume (exp. Volume_0000) in Volumes
  • Asus Z10PR-D16 | User Guide - Page 145
    5.4.4 Preferences System Preferences Allow you to set to show the notification area icon and show system information, warning, or errors here. E-Mail Preferences Allow you to set to sent e-mail of the following events: • Storage system information • Storage system warnings • Storage system
  • Asus Z10PR-D16 | User Guide - Page 146
    5-38 Chapter 5: RAID configuration
  • Asus Z10PR-D16 | User Guide - Page 147
    Chapter 6: Driver installation Driver installation This chapter provides the instructions for installing the necessary drivers for different system components in both Linux® and Windows® Operating Systems. 6
  • Asus Z10PR-D16 | User Guide - Page 148
    disk in DOS (using the Makedisk application in the support DVD). To create a RAID driver disk in DOS environment 1. Place the motherboard support DVD in the optical drive. 2. Restart the computer, and then enter the BIOS Setup. 3. Select the optical drive as the first boot priority to boot from
  • Asus Z10PR-D16 | User Guide - Page 149
    floppy disk drive. 2. Type dd if=XXX.img of=/dev/fd0 to decompress the file into the floppy disk from the following path in the support DVD: For LSI MegaRAID Driver \Drivers\C60x LSI RAID\Driver\makedisk\Linux 3. Eject the floppy disk. Z10PR-D16 6-3
  • Asus Z10PR-D16 | User Guide - Page 150
    2008 OS installation To install the RAID controller driver when installing Windows® Server 2008 OS 1. Boot the computer using the Windows® Server 2008 OS installation disc. Follow the screen instructions to start installing Windows Server 2008. 2. When prompted to choose a type of installation
  • Asus Z10PR-D16 | User Guide - Page 151
    Next. 7. When the system finishes loading the RAID driver, replace the motherboard Support DVD with the Windows Server installation disc. Select the drive to install Windows and click Next. 8. Setup then proceeds with the OS installation. Follow screen instructions to continue. Z10PR-D16 6-5
  • Asus Z10PR-D16 | User Guide - Page 152
    boot: linux dd noprobe=ata1 noprobe=ata2 3. Select Yes using the key when asked if you have the driver disk, then press . Main Menu Do you have a driver disk? Yes No 4. Insert the Red Hat® Enterprise RAID driver disk to the USB floppy disk drive, select OK, then press . Insert
  • Asus Z10PR-D16 | User Guide - Page 153
    controller drivers, select No, then press . More Driver Disks? Do you wish to load any more driver disks? Yes No 6. Follow the onscreen instructions to commands when using a Legacy floppy. mkdir /mnt/driver mount /dev/fd0 /mnt/driver cd /mnt/driver sh replace_ahci.sh reboot Z10PR-D16 6-7
  • Asus Z10PR-D16 | User Guide - Page 154
    the system from the Red Hat® OS installation CD. 2. Press to edit options. 3. While booting from DVD, press to give the third party driver. Enter the following command at the boot: Linux dd blacklist=isci blacklist=ahci nodmraid, then press . 6-8 Chapter
  • Asus Z10PR-D16 | User Guide - Page 155
    You have multiple devices which could serve as source for a driver disk. Choose one you like to use and select OK, then press . Driver Disk Sou8rce You have multiple devices which could serve as source for a driver disk. Which would you like to use? sdc sdd sdb sr0 OK Cancel Z10PR-D16 6-9
  • Asus Z10PR-D16 | User Guide - Page 156
    for the RAID card are installed to the system. 7. When asked if you will load additional RAID controller drivers, select No, then press . More Driver Disks? Do you wish to load any more driver disks? Yes No 8. Follow the onscreen instructions to finish the OS installation. 6-10 Chapter
  • Asus Z10PR-D16 | User Guide - Page 157
    a Linux-based OS to create the RAID driver. When creating the RAID driver, you may refer to the examples below which uses a 64bit SUSE Linux system to create a 64bit RAID driver for SUSE11 sp1. 1. Copy the image file as 01, into a FAT32 USB drive. 5. Rename the 01 folder to CD Image. Z10PR-D16 6-11
  • Asus Z10PR-D16 | User Guide - Page 158
    Installing SUSE 11 Linux OS To install the LSI MegaRAID controller driver when installing SUSE Linux Enterprise Server OS: 1. Boot the system from the SUSE OS installation CD. 2. Use the arrow keys to select Installation from the Boot Options menu. 3. Press , then
  • Asus Z10PR-D16 | User Guide - Page 159
    below screen appears, select the USB floppy disk drive (sda) as the driver update medium. Select OK, then press . Please choose the Driver Update medium. sda: USB Floppy other device OK Back 6. Select Back and follow the onscreen instructions to finish the installation. Z10PR-D16 6-13
  • Asus Z10PR-D16 | User Guide - Page 160
    6-14 Chapter 6: Driver installation
  • Asus Z10PR-D16 | User Guide - Page 161
    the support DVD. The main screen of the Support DVD contains the following tabs: 1. Drivers 2. Utilities 3. MakeDisk 4. Manual 5. Contact The main screen of the Support DVD looks exactly the same on the Windows® Server 2008 R2 and on the Windows® Server 2012 Operating System (OS). Z10PR-D16 6-15
  • Asus Z10PR-D16 | User Guide - Page 162
    6.3.1 Drivers menu tab The Drivers Menu shows the available device drivers if the system detects installed devices. Install the necessary drivers to activate the devices. 6.3.2 Utilities menu tab The Utilities menu displays the software applications and utilities that the motherboard supports.
  • Asus Z10PR-D16 | User Guide - Page 163
    RAID driver disks. Press the arrow down button in the lower part of the menu to view more items. 6.3.4 Manual menu The Manual menu provides the link to the Broadcom NetXtreme II Network Adapter user guide. You need an internet browser installed in your OS to view the User Guide. Z10PR-D16
  • Asus Z10PR-D16 | User Guide - Page 164
    6.3.5 Contact information menu The Contact menu displays the ASUS contact information, e-mail addresses, and useful links if you need more information or technical support for your motherboard. 6-18 Chapter 6: Driver installation
  • Asus Z10PR-D16 | User Guide - Page 165
    section provides the instructions on how to install the Intel® chipset device software on the system. You need to manually install the Intel® privileges. 2. Insert the motherboard/system support DVD to the optical drive. The support DVD automatically displays the Drivers menu if Autorun is enabled
  • Asus Z10PR-D16 | User Guide - Page 166
    and press Next to continue the installation. 7. Toggle Yes, I want to restart the computer npw and click Finish to complete the setup process. 6-20 Chapter 6: Driver installation
  • Asus Z10PR-D16 | User Guide - Page 167
    from the BIN folder. Double-click the ASSETUP.EXE to run the support DVD. 4. Click Intel® I350-AM1/I350-AM2/I210/X540-BT2 Gigabit Adapters Drivers in the Drivers menu of the main screen to start the installation. 5. Click Install Drivers and Software option to begin installation. Z10PR-D16 6-21
  • Asus Z10PR-D16 | User Guide - Page 168
    Setup Options window, click Next to start the installation. By default, Intel(R) PROSet for Windows Device Manager and Windows PowerShell Module are ticked. 6-22 Chapter 6: Driver installation
  • Asus Z10PR-D16 | User Guide - Page 169
    9. Click Install to start the installation. 10. When the installation is done, press Finish to complete the installation. Z10PR-D16 6-23
  • Asus Z10PR-D16 | User Guide - Page 170
    ASPEED Video Graphics Adapter (VGA) driver. You need to manually install the ASPEED VGA driver on a Windows® operating system. To install the ASPEED VGA driver: 1. Restart the computer, and then log on with Administrator privileges. 2. Insert the motherboard/system support DVD to the optical drive
  • Asus Z10PR-D16 | User Guide - Page 171
    5. Click Install to proceed with the installation. 6. Click Finish to complete the installation. Z10PR-D16 6-25
  • Asus Z10PR-D16 | User Guide - Page 172
    Insert the motherboard/system support DVD to the optical drive, and find the utility menu. 3. Click the Intel® Rapid Storage Technology enterprise 4.0 to begin installation. 4. When the Welcome to the Setup Program appears, click Next to start the installation. 6-26 Chapter 6: Driver installation
  • Asus Z10PR-D16 | User Guide - Page 173
    5. Read the Warning message and click Next to continue. 6. Read the License Agreement and click Yes to continue. 7. Read the Readme File Information and click Next to continue. Z10PR-D16 6-27
  • Asus Z10PR-D16 | User Guide - Page 174
    8. After completing the installation, click Next to complete the setup process. 9. Select Yes, I want to restart my computer now and click Finish to restart your computer before using the program. 6-28 Chapter 6: Driver installation
  • Asus Z10PR-D16 | User Guide - Page 175
    Appendix A: Reference Information Reference Information This appendix includes additional information that you may refer to when configuring the motherboard. A
  • Asus Z10PR-D16 | User Guide - Page 176
    A.1 Z10PR-D16 block diagram A-2 Appendix A: Reference information
  • Asus Z10PR-D16 | User Guide - Page 177
    11259 Telephone +886-2-2894-3447 Fax +886-2-2890-7798 E-mail [email protected] Web site http://www.asus.com.tw Technical Support Telephone Online Support +886-2-2894-3447 (0800-093-456) http://support.asus.com/techserv/techserv.aspx ASUSTeK COMPUTER INC. (China) Address No.508
  • Asus Z10PR-D16 | User Guide - Page 178
    Fax +49-2102-959911 Web site http://www.asus.de Online contact http://www.asus.de/sales Technical Support Telephone +49-1805-010923 Support Fax +49-2102-959911 Online support http://support.asus.com/techserv/techserv.aspx ASUS Czech Service s.r.o. (Europe) Address Na Rovince 887, 720 00
  • Asus Z10PR-D16 | User Guide - Page 179
    Sp. z o.o. (Poland) Address Ul. Postępu 6, 02-676 Warszawa, Poland Web site http://pl.asus.com Technical Support Telephone Online Support +48-225718033 http://support.asus.com/techserv/techserv.aspx ASK-Service (Russia and CIS) Address 10 Telephone (495) 640-32-75 Web site http://ru
  • Asus Z10PR-D16 | User Guide - Page 180
    apparatus: ASUSTeK COMPUTER INC. 4F, No. 150, LI-TE Rd., PEITOU, TAIPEI 112, TAIWAN ASUS COMPUTER GmbH HARKORT STR. 21-23, 40880 RATINGEN GERMANY Product name : Motherboard Model name : Z10PR-D16 conform with the essential requirements of the following directives: 2004/108/EC-EMC Directive EN
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180

Z10PR-D16