    Belkin Bulldog Plus Shutdown Management Software for UNIX User's Manual
  • Belkin F6C700 | User Manual - Page 2
    Table of Contents Introduction 4 Bulldog Plus Installation 5 Bulldog Plus Services 6 Bulldog Plus Monitor 7 Networking 8 Remote Monitoring and Control 9 Bulldog Plus Monitor Operation 12 Top Layer Menu 40 Event Log 41 History Graph 42 History Data 43 Remote Hosts 44 Belkin Components 2
  • Belkin F6C700 | User Manual - Page 3
    Buttom Layer Buttons 45 Service and Support 47 Belkin Components 3
  • Belkin F6C700 | User Manual - Page 4
    your computer and attached components are protected from any power problems. Bulldog Plus features: 1.Graceful operating system shutdown 2.Schedule /restart 9.Support Simple Network Management Protocol (SNMP) 10.Support HTTP, remote monitor and control using Internet browser Belkin Components
  • Belkin F6C700 | User Manual - Page 5
    require "-" before arguments. 5. Run ./install. 6. Follow the instructions from the install program. 7. After installation, Bulldog Plus program files comprised of two modules: l A UPS Monitoring Module (Bulldog Plus Service, file name: upsd), that runs in the background as a Belkin Components 5
  • Belkin F6C700 | User Manual - Page 6
    Plus Service, which runs in the background, is a daemon process when the system starts up. You can also run Bulldog Plus Service manually by typing the command ./upsd in the installation directory. To stop Bulldog Plus Service, type the command ./upsd stop in the installation directory. Belkin
  • Belkin F6C700 | User Manual - Page 7
    memory; the execution depends on the user's requirements. This can save precious system resources and maintain a higher level of performance. After finishing the Belkin Bulldog installation, Bulldog Service automatically loads into memory and runs once the Windows operating system has started. The
  • Belkin F6C700 | User Manual - Page 8
    called the Slave. Master communicates to Slave via a TCP/IP network. When a power event occurs, Master (Bulldog Plus Service) gets the information and then transmits it to the Salve(s) (Bulldog Plus Service). Each Bulldog Plus Service executes different "Actions" (FlexEvent) such that the system
  • Belkin F6C700 | User Manual - Page 9
    Plus Monitor without running Bulldog Plus Service, Bulldog Plus Monitor will search hosts in the LAN (Local Area Network) that are running Bulldog Plus Service in the combo box. Click input the remote host IP address from the View - Remote Hosts menu to establish the connection. Belkin Components 9
  • Belkin F6C700 | User Manual - Page 10
    Belkin Components 10
  • Belkin F6C700 | User Manual - Page 11
    Another method for remote monitoring with Bulldog Plus Service is by using the Internet Browser. Launch the Microsoft Internet Explorer or Netscape Communicator, type the IP address in the URL and press enter you will .176.141:2000 where 2000 is the port number you assigned. Belkin Components 11
  • Belkin F6C700 | User Manual - Page 12
    Host Selection: Press the combo box to select hosts that runs Bulldog Plus Service in the LAN. Users can monitor or control (need password) the while the communication between Bulldog Plus Monitor and Bulldog Plus Service is established. Information Display: Press Bottom Layer Buttons to change
  • Belkin F6C700 | User Manual - Page 13
    menu allows you to see the real-time values and history events/data. Help: The Help menu allows you to access the online help system. Belkin Components 13
  • Belkin F6C700 | User Manual - Page 14
    if you want to do configuration or control the UPS, otherwise, you can only view the UPS information. If the user runs Bulldog Plus Service and Bulldog Plus Monitor in the same computer, you can set your configurations or control the UPS without a password. To change your password, please
  • Belkin F6C700 | User Manual - Page 15
    you to change the display items in the Information Display Area. The items in the menu refer to each button in the Bottom Layer Buttons. Belkin Components 15
  • Belkin F6C700 | User Manual - Page 16
    System Menu (cont.) Close Monitor Close Bulldog Plus Monitor and leave Bulldog Plus Service running. Belkin Components 16
  • Belkin F6C700 | User Manual - Page 17
    IP: IP address of a computer, that runs Bulldog Plus Monitor. Bulldog Service Mode: Bulldog Plus Service acts as a Master or Slave. Remote Host IP: The host, that runs Bulldog Plus Service. If Bulldog Plus Monitor and Bulldog Plus Service run on the same computer this field will be empty. Belkin
  • Belkin F6C700 | User Manual - Page 18
    before paging is a ttempted. d. Dial Prefix: The string, that is added to the beginning of each Pager Number before they are sent to the modem. Belkin Components 18
  • Belkin F6C700 | User Manual - Page 19
    the Pager Action in the Action dialog box. a. Add: Add a new pager number. b. Modify: Modify the selected pager number. c. Delete: Delete the selected pager number. Belkin Components 19
  • Belkin F6C700 | User Manual - Page 20
    enable the e -mail Action in the Action dialog box. a. Add: Add a new user. b. Modify: Modify the selected user name. c. Delete: Delete the selected us er. Belkin Components 20
  • Belkin F6C700 | User Manual - Page 21
    hosts that user assigned. b. Add: Add a new machine name. c. Modify: Modify the selected machine name. d. Delete: Delete the selected name. Close: Close the Configuration window. Belkin Components 21
  • Belkin F6C700 | User Manual - Page 22
    Load warning. c. Load Severity: User must reduce UPS loading. d. Last Battery Replacement Date: Record last battery replacement date. e. Next Battery Replacement Date: The date of next battery replacement, Bulldog Plus will notify user to replace f. Host Name: Local host name. Belkin Components 22
  • Belkin F6C700 | User Manual - Page 23
    Log Interval: Time to save a record of UPS data. c. Maximun Data Log Storage: It allows you to save how many months of UPS data files. Belkin Components 23
  • Belkin F6C700 | User Manual - Page 24
    is applicable for every day c. Weekly: This set schedule is applicable for once a week period. d. Monthly: This set schedule is applicable for once a month period. Belkin Components 24
  • Belkin F6C700 | User Manual - Page 25
    set the desired time for delay in the Delay combo box. a. Enable Auto-Save: Bulldog Plus Service running on MS Windows will save opened files and close applications automatically when you enable this function. b. : Clicking on this terminates all the a ctions immediately. Belkin Components 25
  • Belkin F6C700 | User Manual - Page 26
    . Action - Logging: Permits you to log events as well as modify default logging messagex. You can see this message in the Event Log dialog box. Belkin Components Action - Broadcasting: Permits you to broadcast an event based on a set period of time. If you want to be notified once, set the time
  • Belkin F6C700 | User Manual - Page 27
    execute command files and set a period of time to delay its activation. To enable or disable this action, mark the Enable Command check box. Belkin Components Action - Alarm: Permits you to send out audible alarm instead of a broadcast message. There is only buzzer alarm for Bulldog Plus on UNIX
  • Belkin F6C700 | User Manual - Page 28
    check box. You also need to specify the SNMP Trap target hosts and community string, please see the SNMP dialog box in the Network menu. Belkin Components 28
  • Belkin F6C700 | User Manual - Page 29
    Action: Receptacle Control Action - Receptacle Control: Permits you to control Receptacle Relay on or off. Each Receptacle Relay may control only one outlet, please see the rear panel of your UPS or the UPS hardware user's manual. Belkin Components 29
  • Belkin F6C700 | User Manual - Page 30
    Transfer Voltage: When utility power voltage is lower than the assigned value, the UPS will switch to backup. The output power is supplied from battery. b. High Transfer Voltage: When utility power voltage is higher than the assigned value, the UPS will switch to backup. The output power is supplied
  • Belkin F6C700 | User Manual - Page 31
    select this item. Enable Wakeup Computer: If your computer's architecture is compatible to ATX and the BIOS supports RS-232 (RI) Wakeup function. You should enable this item to make the Schedule work correctly. the test procedure automatically when it reaches the test time. Belkin Components 31
  • Belkin F6C700 | User Manual - Page 32
    c. Master IP Address: When Bulldog Plus Service becomes a Slave you must assign the Master IP address such that the Slave can connect to the Master host and get the UPS information. If you leave the item empty or type a wrong address, Bulldog Plus will show a disconnected message. Belkin Components
  • Belkin F6C700 | User Manual - Page 33
    Packet through the network. You must give the IP address and the network hardware address (MAC address) of the remote host. In Windows98, you can address of the local host. Or, input the "arp -a" command to see the remote host's physical address. Your network card must support Belkin Components 33
  • Belkin F6C700 | User Manual - Page 34
    its respective command button. If the Bulldog Plus Service you are connecting is running on UNIX series Service you are connecting is running on Windows NT must install the SNMP Service and configure the SNMP the SNMP Service in the Network option. Select the SNMP Service from the Network option
  • Belkin F6C700 | User Manual - Page 35
    If the Bulldog Plus Service you are connecting battery ground fault 16 INFORMATION: The UPS test in progress 17 SEVER: The UPS test in progress 18 SEVER: The UPS fuse failed 19 INFORMATION: The UPS fuse recovered 20 SEVER: The UPS overload 21 INFORMATION: Recovered from UPS over- load Belkin
  • Belkin F6C700 | User Manual - Page 36
    DupsNoLongerEnvOverTemperature 33 INFORMATION: The environment recovered from over temperatur DupsEnvOverHumidity 34 WARNING: The environment over humidit DupsNoLongerEnvOverHumidity 35 INFORMATION: The environment recovered from over humidity Belkin Components 36
  • Belkin F6C700 | User Manual - Page 37
    Bulldog Plus supports WEB Server for remote manager to get UPS information. User can use IE or the Communicator to connect to Bulldog Plus Service. Even if there is already one WEB server running you can change Bulldog Plus Service HTTP port number to a different number. At the Internet Browser you
  • Belkin F6C700 | User Manual - Page 38
    selected receptacle relay on. Each Receptacle Relay may control only one outlet, please see the rear panel of your UPS or the UPS hardware user's manual. Belkin Components 38
  • Belkin F6C700 | User Manual - Page 39
    , please see the rear panel of your UPS or the UPS hardware user's manual. a. Select a Receptacle Relay: Select a receptacle relay. b. Delay: Set is supplied by battery in 10 seconds. Deep Battery Test: UPS switches to backup mode and output power is supplied by battery until the battery level is
  • Belkin F6C700 | User Manual - Page 40
    View Menu Meters: The Bulldog Plus supports up to 12 meters to be display in real-time values. Each meter has the ability to display all value. a. 2,4,6,8,12: Displayed meter number. b. Selection: Assign each meter to different UPS item value. c. Close: Close the meter window. Belkin Components 40
  • Belkin F6C700 | User Manual - Page 41
    Event Log Event Log: This menu offers you the possibility of viewing past events. a. Exit: Close event log dialog box. Belkin Components 41
  • Belkin F6C700 | User Manual - Page 42
    by blue line. e. Draw Item2(Red): Denotes the UPS item value by red line. f. Update: Update the graph. g. Exit: Close the history graph dialog box. Belkin Components 42
  • Belkin F6C700 | User Manual - Page 43
    view. a. Select Month: The UPS data in the month, that you want to see. b. Update: Update the list. c. Exit: Close the history data dialog box. Belkin Components 43
  • Belkin F6C700 | User Manual - Page 44
    Detect the hosts which running the Bulldog Plus Service in the LAN. You can also type in the IP address and connect to the WAN. a. Search button to establish the connection. b. Connect to this IP address: Bulldog Plus will connect to the IP address that you type in. c. Connect: Establish the network
  • Belkin F6C700 | User Manual - Page 45
    the UPS information. Time: Displays the time of the schedule, battery replacement date and countdown time. Status: UPS status. Diagram: Indicate Network: Indicate the connection of Master/Slave, Bulldog Plus Monitor and Bulldog Plus Service. Main UPS Health: 3 levels: Green, yellow and red. UPS Type
  • Belkin F6C700 | User Manual - Page 46
    Battery Replacement Date: To change the date of last battery replacement in the System-> Configuration UPS->UPS Property. Next Battery Replacement Date: To change the date of next battery replacement Network Display all the Bulldog Plus Service searched in the LAN. Outlet Display Belkin Components 46
  • Belkin F6C700 | User Manual - Page 47
    • USA Tel: 310.898.1100 Fax: 310.898.1111 Customer Service/Sales: 800.2BELKIN 800.223.5546 Technical Support: 310.898.1100 ext. 2263 800.223.5546 ext. 2263 Fax: 310.604.2089 [email protected] belkin.com/support/tech Belkin Components, Ltd. United Kingdom Express Business Park Shipton Way
  • Belkin F6C700 | User Manual - Page 48
    Starparc Building • Boeing Avenue 333 1119 PH Schiphol-Rijk • The Netherlands Tel: +31 (0) 20 654 7300 Fax: +31 (0) 20 654 7349 European Customer Service/Sales: 00 800 223 55 460 [email protected] European Tech Support: 00 800 223 55 460 [email protected] Belkin Components 48
  • Belkin F6C700 | User Manual - Page 49
    Singapore Toll Free 800 6161 790 belkin.com/anz China Belkin Shanghai Representative Office Suite 31 • 39/F • Plaza 66 1266 Nanjing West Road Shanghai • 200040 • China Tel: 8621-62881747 Fax: 8621-62881748 Customer Service/Sales: [email protected] Tech Support: 800-820-5816 Belkin Components 49
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49

Belkin Bulldog Plus
Shutdown Management Software
for UNIX
User’s Manual