- Brother International BAS-423 | Changing Needle Bar Cushions - English - Page 1
5, 2009 Models: BAS-416, BAS-416A, BAS-423, BAS-423A, BE-0901, BE-1201, BES-916, BES-1216, BES-1230, BES-1210, BES-1240, BES-1241, BES-1260, BES-1261, BES- Remove the lower cover (plate that has the Brother logo on it). 3. Loosen Top Dead Center Stopper screw with a 2.5mm hex wrench on all the - Brother International BAS-423 | Changing Needle Bar Cushions - English - Page 2
Push down on the Top Dead Center Stopper with one hand. Do not release it until instructed to do so. While holding the Top Dead Center Stopper down with one hand, use your 7 on up. 10. Please see "Adjusting Needle Bar Height" in instruction manual for completing adjustment of each needle bar. 2
1
Technical Reference
Title:
Needle Bar Cushions - changing
Date:
March 5, 2009
Models:
BAS-416, BAS-416A, BAS-423, BAS-423A, BE-0901, BE-1201, BES-916,
BES-1216, BES-1230, BES-1210, BES-1240, BES-1241, BES-1260, BES-1261, BES-
1262, BES-1263, BES-960, BES-961
1. Move the needle case to the highest
needle bar number (9 or 12
depending on your model).
2. Remove the lower cover (plate that
has the Brother logo on it).
3. Loosen Top Dead Center Stopper
screw with a 2.5mm hex wrench on
all the needles.