- Brother International BAS-423A | Changing Needle Bar Cushions - English - Page 1
, BES-916, BES-1216, BES-1230, BES-1210, BES-1240, BES-1241, BES-1260, BES-1261, BES- 1262, BES-1263, BES-960, BES-961 1. Move the needle case to the highest needle bar number (9 or 12 depending on your model). 2. Remove the lower cover (plate that has the Brother logo on it). 3. Loosen Top Dead - Brother International BAS-423A | Changing Needle Bar Cushions - English - Page 2
it's even with the needle bar(s) next to it. After this is done, you may let go of the Top Dead Center Stopper. 8. Repeat for needles 1-6. 9. Move the needle case to needle number 1 and finish the needles from 7 on up. 10. Please see "Adjusting Needle Bar Height" in instruction manual for completing
1
Technical Reference
Title:
Needle Bar Cushions - changing
Date:
March 5, 2009
Models:
BAS-416, BAS-416A, BAS-423, BAS-423A, BE-0901, BE-1201, BES-916,
BES-1216, BES-1230, BES-1210, BES-1240, BES-1241, BES-1260, BES-1261, BES-
1262, BES-1263, BES-960, BES-961
1. Move the needle case to the highest
needle bar number (9 or 12
depending on your model).
2. Remove the lower cover (plate that
has the Brother logo on it).
3. Loosen Top Dead Center Stopper
screw with a 2.5mm hex wrench on
all the needles.