Brother International KE-430F Input Check - English
Brother International KE-430F Manual
View all Brother International KE-430F manuals
Add to My Manuals
Save this manual to your list of manuals |
Brother International KE-430F manual content summary:
- Brother International KE-430F | Input Check - English - Page 1
= Input status 2618B Check code Abbreviatio n [ 1] [orX] [ 2] [ 3] [ 4] [EnX] [orY] [EnY] Input status Check items and checking methods X-feed shaft motor home position sensor position [ on]/[ oFF] Move the feed mechanism manually in the X-feed direction [-999]~[ 999 - Brother International KE-430F | Input Check - English - Page 2
Check code [ 5] [ 6] [ 7] [ 8] [ 9] [ 10] [ 11] [ 12] [ 13] [ 14] [ 15] Abbreviatio n [orP] [EnP] [dEG] [ UP] [voL] [PnL] [FtA] [FtS] [CL1] [CL2] [Stt] Input status Check items and checking methods [ - Brother International KE-430F | Input Check - English - Page 3
Check code [ 16] [ 17] [ 18] [ 19] [ 20] [ 21] [ 22] [ 23] [ 24] [ 25] [ 26] [ 27] [ 28] [ 29] Abbreviatio n [EMC] [HEd] [orn] [Enn] [in1] [in2] [in3] [in4] [in5] [in6] [ - Brother International KE-430F | Input Check - English - Page 4
and after, depress the foot switch to the 2nd step. 4. When returning to normal operation, turn power off and then on again. Check code [ 51] [ 52] [ 53] [ 54] Abbreviation [PM-X] [PM-y] [PM-P] [PM-n] When you press the When you press the When you press the When you press the - Brother International KE-430F | Input Check - English - Page 5
on. [ 76] [oP18] Option output 18 turns on. [ 77] [oP19] Option output 19 turns on. [ 78] [oP20] Option output 20 turns on. ・ * Spare for the KE-430F and BE-438
. INPUT Check
1.
Press
△
key (1) + Power ON
Program Number display (2) = Check Code
Tension display (3) = Abbreviation
Menu display (4) = Input status
<Input check list>
Check
code
Abbreviatio
n
Input status
Check items and checking methods
[
1
]
[
orX
]
[
on
]
/
[
oFF
]
X-feed shaft motor home position sensor position
Move the feed mechanism manually in the X-feed
direction
[
2
]
[
EnX
]
[
-999
]~[
999
]
X-feed shaft motor encoder counter value
[
3
]
[
orY
]
[
on
]
/
[
oFF
]
Y-feed shaft motor home position sensor position
[
4
]
[
EnY
]
[
-999
]~[
999
]
Y-feed shaft motor encoder counter value
2618B