Brother International CS6000i User Guide - Page 58

Maintenance - case

Page 58 highlights

NCBC2000.book Page 57 Thursday, October 21, 2004 4:32 PM MAINTENANCE Simple sewing machine maintenance operations are described below. Cleaning the machine Cleaning the bobbin case surface If the surface of the machine is dirty, lightly soak a cloth in neutral detergent, squeeze it out firmly, and then wipe the surface of the machine. After cleaning it once with a wet cloth, wipe it again with a dry cloth. CAUTION Sewing performance will suffer if dust collects in the bobbin case; therefore, it should be cleaned periodically. CAUTION ● Make sure you unplug the machine before you clean it. Otherwise, you may get an electric shock or be injured. ● Unplug the power supply cord before cleaning the machine, otherwise injuries or an Switch the machine off and unplug it. electric shock may occur. a 4 Raise the needle and the presser foot. b Loosen the presser-foot screw and the needle c clamp screw to remove the presser-foot holder and the needle. Grasp both sides of the needle plate cover, d and then slide it toward you to remove the needle plate cover. a Needle plate cover 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

57
4
MAINTENANCE
Simple sewing machine maintenance operations are described below.
Cleaning the machine
surface
If the surface of the machine is dirty, lightly soak a
cloth in neutral detergent, squeeze it out firmly, and
then wipe the surface of the machine. After cleaning
it once with a wet cloth, wipe it again with a dry
cloth.
Cleaning the bobbin case
Sewing performance will suffer if dust collects in the
bobbin case; therefore, it should be cleaned
periodically.
a
Switch the machine off and unplug it.
b
Raise the needle and the presser foot.
c
Loosen the presser-foot screw and the needle
clamp screw to remove the presser-foot
holder and the needle.
d
Grasp both sides of the needle plate cover,
and then slide it toward you to remove the
needle plate cover.
a
Needle plate cover
Unplug the power supply cord before
cleaning the machine, otherwise injuries or an
electric shock may occur.
CAUTION
Make sure you unplug the machine before
you clean it. Otherwise, you may get an
electric shock or be injured.
CAUTION