Brother International HL-4570CDW Users Manual - English - Page 133
When you have found the mark on the drum that matches the drum dot check sheet, wipe the surface
UPC - 012502625001
View all Brother International HL-4570CDW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 133 highlights
Routine Maintenance k Confirm suspected area of the appropriate color drum by using the numbers beside the drum which relate to the numbers of column. 5 l Turn the drum unit gear toward you by hand while looking at surface of the suspected area. m When you have found the mark on the drum that matches the drum dot check sheet, wipe the surface of the drum gently with a cotton swab until the mark on the surface comes off. IMPORTANT DO NOT clean the surface of the photosensitive drum with a sharp object. 127
Routine Maintenance
127
5
k
Confirm suspected area of the appropriate color drum by using the numbers beside the drum which
relate to the numbers of column.
l
Turn the drum unit gear toward you by hand while looking at surface of the suspected area.
m
When you have found the mark on the drum that matches the drum dot check sheet, wipe the surface
of the drum gently with a cotton swab until the mark on the surface comes off.
IMPORTANT