Function List, FUNCTION SETTINGS OPERATION PANEL, Function No. 0

Page 13 highlights

3. FUNCTION SETTINGS (OPERATION PANEL) 3-5. Function List Function No. 0 − 15 No. Initial value 0 0 (degrees) 1 0 (degrees) 2 0 3 1 4 0 5 0 6 0 7 0 9 0 11 (NOTE 1) 0 12 0 13 0 14 0 15 0 Setting range -10 - 20 (degrees) -10 - 10 (degrees) 0 - 1 0 - 1 0 - 1 - 0 - 1 0 - 1 0 - 1 0 - 4 0 - 1 0 - 1 0 - 1 0 - 1 Setting details Needle up stop position setting Becomes higher Needle down stop position setting Becomes lower 2243M Becomes lower Becomes higher 2244M Depressing forward when depressed backward (thread trimming) 0: Disabled (depressing forward is enabled after returning to neutral position) 1: Enabled Power supply voltage drop check (reset detection) function 0: Not used 1: Used; "Err 6" is displayed when a voltage drop occurs Buzzer (electronic sound) for panel operation 0: Used 1: Not used (Do not change this setting.) Needle penetration up operation 0: Used 1: Not used Backtack sewing speed 0: Limited by sewing speed control key 1: Not limited by sewing speed control key End backtack sewing speed 0: Separate setting from start backtack sewing speed is possible 1: Setting for start backtack sewing is used Option actuator operation setting 0: Half stitch correction sewing 1: Single stitch correction sewing 2: Single reverse stitch correction sewing (reverse feed) 3: Thread trimming 4: Single end backtack cycle cancel 5: Solenoid-type presser foot lifter is raised (Alternating*) 6: Solenoid-type presser foot lifter is raised (Momentary*) Presser foot status when treadle is returned to neutral after thread trimming 0: Presser foot drops (See NOTE 2) 1: Presser foot does not drop Presser foot status after treadle stops at neutral 0: Presser foot does not lift 1: Presser foot lifts Actuator function 0: Reverse stitch switch during operation, correction sewing switch when stopped 1: Thread trimming switch Slow stop control when treadle is returned to neutral 0: Slow stop control without step operation 1: Above control is not used (NOTE 1) If function No. 69 is set to "3", operation is enabled. (NOTE 2) Presser foot will not drop if DIP switch 1 is set to OFF. *... Enabled if the control box model is MD-741A/751A. (Alternating): The presser foot is raised or lowered each time the optional actuator is pressed. (Momentary): The presser foot is raised only while the optional actuator is being pressed. S-7200B 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

S-7200B
3. FUNCTION SETTINGS (OPERATION PANEL)
6
Becomes higher
Becomes lower
Becomes lower
Becomes higher
3-5. Function List
Function No. 0
15
No.
Initial value
Setting range
Setting details
0
0 (degrees)
-10
20
(degrees)
Needle up stop position setting
1
0 (degrees)
-10
10
(degrees)
Needle down stop position setting
2
0
0
1
Depressing forward when depressed backward (thread trimming)
0: Disabled (depressing forward is enabled after returning to neutral position)
1: Enabled
3
1
0
1
Power supply voltage drop check (reset detection) function
0: Not used
1: Used; "Err 6" is displayed when a voltage drop occurs
4
0
0
1
Buzzer (electronic sound) for panel operation
0: Used
1: Not used
5
0
(Do not change this setting.)
6
0
0
1
Needle penetration up operation
0: Used
1: Not used
7
0
0
1
Backtack sewing speed
0: Limited by sewing speed control key
1: Not limited by sewing speed control key
9
0
0
1
End backtack sewing speed
0: Separate setting from start backtack sewing speed is possible
1: Setting for start backtack sewing is used
11
(NOTE 1)
0
0
4
Option actuator operation setting
0: Half stitch correction sewing
1: Single stitch correction sewing
2: Single reverse stitch correction sewing (reverse feed)
3: Thread trimming
4: Single end backtack cycle cancel
5: Solenoid-type presser foot lifter is raised (Alternating*)
6: Solenoid-type presser foot lifter is raised (Momentary*)
12
0
0
1
Presser foot status when treadle is returned to neutral after thread trimming
0: Presser foot drops (See NOTE 2)
1: Presser foot does not drop
13
0
0
1
Presser foot status after treadle stops at neutral
0: Presser foot does not lift
1: Presser foot lifts
14
0
0
1
Actuator function
0: Reverse stitch switch during operation, correction sewing switch when
stopped
1: Thread trimming switch
15
0
0
1
Slow stop control when treadle is returned to neutral
0: Slow stop control without step operation
1: Above control is not used
(NOTE 1) If function No. 69 is set to “3”, operation is enabled.
(NOTE 2) Presser foot will not drop if DIP switch 1 is set to OFF.
*…
Enabled if the control box model is MD-741A/751A.
(Alternating): The presser foot is raised or lowered each time the optional actuator is pressed.
(Momentary): The presser foot is raised only while the optional actuator is being pressed.
2244M