Brother International S-7200B Service Manual - Page 49

Rotary hook RP, REPLACING PARTS, <Replacing&gt, <Adjusting the adjusting screw&gt

Page 49 highlights

7. REPLACING PARTS 7-4. Rotary hook RP If replacing the standard rotary hook with a rotary hook RP (lubrication-free rotary hook) on sub-class -40[] or -43[] machines, use the following parts. S52936-001 (ROTARY HOOK, W/BOX) S35786-001 (SCREW, CAP) NOTE: When using the rotary hook RP (lubrication-free rotary hook), set the sewing speed to 4,000 rpm or less. 1. Remove the needle and the presser foot. 2. Remove the needle plate (1) and the feed dog (2). 3. Remove the rotary hook. 4. Replace the screw (3). Tighten the screw (3) securely. 5. Install the rotary hook RP(4) and the needle. After installing the rotary hook RP, adjust the needle and rotary hook timing. (Refer to page 31.) 6. Install the feed dog (2). 7. Install the needle plate (1). Adjust the installation position of the feed dog (2) so that it is in the middle of the needle plate (1) groove. 8. Install the presser foot. 2313M 0740B Tighten the adjusting screw (5) as far as it will go, and then turn it back the other way about three full turns. (At this time, the head (A) of the adjusting screw (5) should be almost flush with the edge (B) of the bed.) NOTE: If the sewing machine is used while the adjusting screw (5) is in the fully-tightened position, it will cause oil to leak out through the gap between the rotary hook shaft (6)and the bracket (7). 0741B S-7200B 42

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

S-7200B
7. REPLACING PARTS
42
7-4. Rotary hook RP
If replacing the standard rotary hook with a rotary hook RP (lubrication-free rotary hook) on sub-class -40[] or -43[] machines,
use the following parts.
S52936-001 (ROTARY HOOK, W/BOX)
S35786-001 (SCREW, CAP)
NOTE:
When using the rotary hook RP (lubrication-free rotary hook), set the sewing speed to 4,000 rpm or less.
<Replacing>
1. Remove the needle and the presser foot.
2. Remove the needle plate (1) and the feed dog (2).
3. Remove the rotary hook.
4. Replace the screw (3).
Tighten the screw (3) securely.
5. Install the rotary hook RP(4) and the needle.
After installing the rotary hook RP, adjust the needle and
rotary hook timing. (Refer to page 31.)
6. Install the feed dog (2).
7. Install the needle plate (1).
Adjust the installation position of the feed dog (2) so that it
is in the middle of the needle plate (1) groove.
8. Install the presser foot.
<Adjusting the adjusting screw>
Tighten the adjusting screw (5) as far as it will go, and then
turn it back the other way about three full turns.
(At this time, the head (A) of the adjusting screw (5) should
be almost flush with the edge (B) of the bed.)
NOTE:
If the sewing machine is used while the adjusting
screw (5) is in the fully-tightened position, it will
cause oil to leak out through the gap between the
rotary hook shaft (6)and the bracket (7).
2313M
0741B