Mounting on a Suspended Ceiling Chapter 3 Mounting Instructions Mounting on a Suspended Ceiling Follow these steps to mount your access point on a suspended ceiling. It may be helpful to refer to Figure 3-2 before beginning the process. Figure 3-2 Suspended Ceiling Mounting Bracket Parts 1 2 2 3 3 4 5 5 81190 1 Suspended ceiling T-rail 2 Caddy fastener 3 Plastic spacer 4 Wall or ceiling mounting bracket 5 Keps nut Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Determine the location at which to mount the access point. Attach two caddy fasteners to the ceiling's T-rail. Use the wall or ceiling mounting bracket to adjust the distance between the caddy fasteners so that they align with the holes in the bracket. • The distance between the caddy fastener studs is 2.5 in (6.35 cm). Use a standard screwdriver to tighten the caddy fastener studs in place on the T-rail. Do not overtighten. Install a plastic spacer on each caddy fastener stud. The spacer's legs should contact the ceiling grid T-rail. Attach the wall or ceiling mounting bracket to the caddy fastener studs and start a Keps nut on each stud. Use a wrench or pliers to tighten the Keps nuts. Do not overtighten. Cisco Aironet 1100 Series Access Point Hardware Installation Guide 3-4 OL-4309-07

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

3-4
Cisco Aironet 1100 Series Access Point Hardware Installation Guide
OL-4309-07
Chapter 3
Mounting Instructions
Mounting on a Suspended Ceiling
Mounting on a Suspended Ceiling
Follow these steps to mount your access point on a suspended ceiling. It may be helpful to refer to
Figure 3-2
before beginning the process.
Figure 3-2
Suspended Ceiling Mounting Bracket Parts
Step 1
Determine the location at which to mount the access point.
Step 2
Attach two caddy fasteners to the ceiling’s T-rail.
Step 3
Use the wall or ceiling mounting bracket to adjust the distance between the caddy fasteners so that they
align with the holes in the bracket.
The distance between the caddy fastener studs is 2.5 in (6.35 cm).
Step 4
Use a standard screwdriver to tighten the caddy fastener studs in place on the T-rail. Do not overtighten.
Step 5
Install a plastic spacer on each caddy fastener stud. The spacer’s legs should contact the ceiling grid
T-rail.
Step 6
Attach the wall or ceiling mounting bracket to the caddy fastener studs and start a Keps nut on each stud.
Step 7
Use a wrench or pliers to tighten the Keps nuts. Do not overtighten.
1
Suspended ceiling T-rail
4
Wall or ceiling mounting bracket
2
Caddy fastener
5
Keps nut
3
Plastic spacer