- Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 1
HP BladeSystem p-Class and c-Class servers 10 Cabling stacked HP 1/10G Virtual Connect Ethernet Modules 13 Adjustable fan speeds in the HP BladeSystem c7000 enclosure 16 ProLiant for HP BladeSystem c-Class server blades or the c-Class power enclosure. How to make a request for server blade - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 2
ISS Technology Update NOTE The HPONCFG command is supported with Onboard Administrator Version 2.00 (or greater). OA-12345678> HPONCFG ALL tftp://some/power/ribcl/script.xml Figure 1-1. Sample output from HPONCFG ALL command Volume 6, Number 7 2 - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 3
12345678> SHOW POWER Figure 1-2. Sample output from SHOW POWER command The SHOW ENCLOSURE STATUS command displays the enclosure health, Onboard Administrator health, and unit identification LED in the "Enclosure" section. The "Power Subsystem" section displays the power status and capacity (Figure - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 4
Update Figure 1-3. Sample output from SHOW ENCLOSURE STATUS command Volume 6, Number 7 Using HP Lights-Out XML Scripting as an alternative method for accessing power consumption information for HP BladeSystem p-Class servers HP Systems Insight Manager (HP SIM) 5.1 or later is the easiest - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 5
a request for power enclosure information" section). Figure 2-1. Sample output from the first request ProLiant BL35p G1 < WMM> 477 M00SNC2146 D232KJP3D008 - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 6
for the second request is as follows: http:///xmldata?item=icmb&addr= Where is the ICMB address of the power enclosure to be viewed. The data returned contains information about the current generated by each supply in the tag (see the yellow - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 7
> 24 35 55 32 70 75 Volume 6, Number 7 7 - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 8
in Table 2-2. Table 2-2. Web resources Resource URL HP BladeSystem server information and resources www.hp.com/go/blades HP Lights-Out product information and resources www.hp.com/go/ilo HP Systems Insight Manager product information and resources www.hp.com/go/hpsim 1 The power supply is - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 9
BL680c G5 ProLiant DL320s ProLiant BL685c ProLiant DL360 G5 ProLiant BL20p G4 ProLiant DL365 ProLiant BL25p G2 ProLiant DL380 G5 ProLiant BL45p G2 ProLiant DL385 G2 ProLiant DL580 G5 ProLiant DL585 G2 HP ProLiant ML servers ProLiant ML110G4 ProLiant ML115 ProLiant ML150 G3 ProLiant ML370 - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 10
support.microsoft.com/kb/283037 that is part of the Microsoft website. Basic power control for HP BladeSystem p-Class and c-Class servers enclosures, two external bus bars, and five server enclosures. This configuration is shown in Figure 4-1. Power is distributed to the attached server enclosures - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 11
. Each of these circuit breakers allows DC power to be turned off for unused power taps or for service of an individual server enclosure without power interruption to other attached server enclosures. The p-Class power structure's two independent -48 VDC bus bars (A and B) are energized by the power - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 12
separate enclosure subsystems (power and server), bus bars, or DC power cables with in-use service complexities (Figure 4-2). Complete power integration negates the previous need for AC and DC breakers at multiple stages of an external power distribution subsystem. Figure 4-2. HP BladeSystem - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 13
websites Technology briefs HP BladeSystem www.hp.com/go/blades HP BladeSystem c-Class architecture HP BladeSystem c7000 Enclosure technologies Managing the HP BladeSystem c-Class http://h20000.www2.hp.com/bc/docs/support/SupportManual/c0 0810839/c00810839.pdf http://h20000.www2.hp.com/bc/docs - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 14
adjusting the .5m 10GbE CX4 cable To manually adjust the .5m 10GbE CX4 cable to meet the bend 10G Virtual Connect Ethernet modules as shown in Figure 5-1. Figure 5-1. Initial bend radius 2. Manually form the cable to have a larger, more rounded configuration as shown in Figure 5-2. Figure 5-2. - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 15
ISS Technology Update Volume 6, Number 7 3. If you will need to close the rack door, the cable may need additional manipulation as shown in Figures 5-3 and 5-4. Figure 5-3. Adjusted cable so that the rack door can close Figure 5-4. Adjusted cable with door closed 15 - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 16
to log onto the Onboard Administrator system for a specific enclosure, and then go to the Power and Thermal category where the fan information can be found. 2 The HP Onboard Administrator User Guide can be found at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00705292/c00705292.pdf. 16 - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 17
by the Onboard Administrator for a typical 10-fan c7000 enclosure. Figure 6-1. View of a fan summary from the HP Onboard Administrator A more detailed view of the fans and their zones is shown on the fan zones tab of the HP Onboard Administrator. Figure 6-2 shows the devices within that zone, the - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 18
product websites HP BladeSystem www.hp.com/go/blades HP Systems Insight Manager www.hp.com/go/hpsim Technology briefs HP BladeSystem c-Class architecture HP BladeSystem c7000 Enclosure technologies Managing the HP BladeSystem c-Class http://h20000.www2.hp.com/bc/docs/support/SupportManual/c0 - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 19
"How to manage non-HP servers with HP Systems Insight Manager in the Information Library. Also in the Information Library, you can find several Success Stories from customers who have shared their experiences with HP SIM. Just use the SIM sizer you'll find under Technical Support. Follow the "ITRC - Compaq BL10e | ISS Technology Update, Volume 6 Number 7 - Newsletter - Page 20
at www.hp.com/servers/technology. Contact us Send comments about this newsletter to [email protected]. Legal Notices © Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set
ISS Technology Update
Volume 6, Number 7
Keeping you informed of the latest ISS technology
Using HP Onboard Administrator as an alternative method for accessing power consumption information
for HP BladeSystem c-Class servers
.........................................................................................................
1
Using HP Lights-Out XML Scripting as an alternative method for accessing power consumption
information for HP BladeSystem p-Class servers
......................................................................................
4
Recovering memory that is invisible to the Microsoft® Windows® operating system
................................
9
Basic power control for HP BladeSystem p-Class and c-Class servers
.....................................................
10
Cabling stacked HP 1/10G Virtual Connect Ethernet Modules
.................................................................
13
Adjustable fan speeds in the HP BladeSystem c7000 enclosure
..............................................................
16
ProLiant management tip of the month
..................................................................................................
18
Recently published industry standard server technology papers
............................................................
20
Contact us
.............................................................................................................................................
20
Using HP Onboard Administrator as an alternative method for accessing power
consumption information for HP BladeSystem c-Class servers
HP Onboard Administrator Command Line Interface (CLI) commands can be used (and scripted) to view power consumption
information for HP BladeSystem c-Class server blades or the c-Class power enclosure.
How to make a request for server blade information
The HPONCFG command sends a Remote Insight Board Command Language (RIBCL) script to the specified BladeSystem
c-Class server blades. You can send the same RIBCL script to one or more of the server blades in the enclosure, such as in the
following examples:
•
HPONCFG ALL returns power consumption information for all server blades in the enclosure.
•
HPONCFG 1, 3, 5 returns power consumption information for server blades in Bays 1, 3, and 5.
•
HPONCFG returns power consumption information for server blades in Bay 2 (Figure 1-1 shows the sample output).