Compaq ML330e Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui
Compaq ML330e - ProLiant - 64 MB RAM Manual
UPC - 720591690243
View all Compaq ML330e manuals
Add to My Manuals
Save this manual to your list of manuals |
Compaq ML330e manual content summary:
- Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 1
ProLiant ML330e/ML330 Server Maintenance and Service Guide Fourth Edition (March 2001) Part Number 174623-004 Spare Part Number 176670-001 Compaq Computer Corporation - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 2
the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting a further or additional warranty. Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Fourth Edition (March 2001) Part Number 174623-004 Spare Part Number 176670-001 - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 3
Guide Symbols in Text...v Important Safety Information v Compaq ProLiant ML330e Server 2-10 SCSI Hard Drive Compartment (ProLiant ML330 Server 2-12 Hard Drives ...2-14 Power Switch...2-15 Fan ...2-17 Cable Routing Diagrams 2-18 Processor with Heatsink 2-21 Memory Modules 2-23 Removing a Memory - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 4
iv Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Removal and Replacement Procedures continued Expansion Board Guide 2-28 System Board ...2-29 Power Supply ...2-30 Replacing a Battery 2-31 Replacing the System Board Battery 2-31 Replacing the Server Feature Board Battery 2-33 - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 5
Guide This maintenance and service guide is a troubleshooting guide that can be used for reference when servicing the Compaq ProLiant ML330e/ML330 server. WARNING: To reduce the risk of personal injury from electric shock and hazardous energy levels, only authorized service specific instructions. - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 6
vi Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Compaq Technician Notes WARNING: Only authorized technicians trained by Compaq can attempt to repair this equipment. All troubleshooting and repair procedures are detailed to allow only subassembly/module-level repair. Because of - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 7
are available: User documentation Compaq Service Quick Reference Guide Service training guides Compaq service advisories and bulletins Compaq QuickFind™ information services Compaq Insight Manager software Integrated Management Log The ProLiant ML330e/ML330 server includes an integrated, nonvolatile - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 8
1 Chapter Illustrated Parts Catalog This chapter provides the illustrated parts breakdown and spare parts lists for the Compaq ProLiant™ ML330e/ML330 server with an Intel Pentium III processor and a 133-MHz system bus. See Table 1-1 and Table 1-2 for the names of referenced spare parts. - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 9
1-2 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Mechanical Parts Exploded View 3a 3b 2 4c 5a Figure 1-1. Mechanical parts exploded view 4b 1 4a - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 10
ML330e server ProLiant ML330 server Panel access left/right a) Hood panel (right) b) Access panel (left) Miscellaneous Hardware kit a) Hard drive compartment b) Removable drive tray c) Expansion board knockout Miscellaneous plastics kit a) Expansion board guide b) Rubber bumpers* c) Removable - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 11
1-4 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide System Components Exploded View 13 9 10 14 15 16a 11 12 15 Figure 1-2. System components exploded view 6a 7 8a - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 12
ML330e server ProLiant ML330 server Server Feature Board ProLiant ML330e server ProLiant ML330 server Power CE Mark-compliant power supply Spare Part Number 163354-001 179963-001 123958-001 230699-001 349534-001 176609-001 159225-001 159226-001 164278-001 159304-001 159377-001 159227-001 177628-001 - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 13
1-6 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Table 1-2 System Components Spare Parts List continued Item Description 14 Pentium III processor a) 667/133 with heatsink* b) 733/133 with heatsink* c) 800/133 with heatsink* (ProLiant ML330e and ML330) d) 866/133 with heatsink* - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 14
for the Compaq ProLiant ML330e/ML330 server. Run the diagnostics program to verify that all components properly operate. To service the ProLiant ML330e/ML330 server, you might need the following: Torx T-15 screwdriver Phillips screwdriver From the Compaq SmartStart™ and Support Software CD: Array - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 15
2-2 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Electrostatic Discharge Information An electrostatic discharge (ESD) can damage static-sensitive devices or microcircuitry place drives with the Printed Circuit Board (PCB) assembly-side down. Use conductive field service tools. - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 16
upgrades, and servicing to qualified personnel. This symbol indicates the presence of electric shock hazards. The area contains no user- or field-serviceable on power supplies or systems, indicate that the equipment is supplied by multiple sources of power. manual material Weight in lb handling. - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 17
2-4 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Preparation Procedures WARNING: Only authorized technicians trained by Compaq should attempt to repair this equipment. Because of the complexity of the individual boards and subassemblies, no one should attempt to make repairs at - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 18
injury and to prevent damage to the equipment, before removing the front bezel, make sure that the server is powered down, all cables are disconnected from the back of the server, and the power cord is disconnected from the grounded (earthed) AC outlet. To remove the front bezel: 1. Complete the - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 19
2-6 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Access Panel WARNING: To reduce the risk removing the access panel, make sure that the server is powered down, all cables are disconnected from the back of the server, and the power cord is disconnected from the grounded (earthed) - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 20
and Replacement Procedures 2-7 Storage Devices The ProLiant ML330e/ML330 server ships standard with seven drive bays, five Position Table 2-1 Storage Device Drive Bay Descriptions Description 5.25-inch x 1.6-inch IDE CD-ROM drive bay 5.25-inch x 1.6-inch available removable media drive bay 5.25-inch - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 21
2-8 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Bezel Blanks To remove a bezel blank from the front bezel: WARNING: To reduce the risk of personal injury and to prevent damage to the equipment, before removing the front bezel, make sure that the server is powered down, all - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 22
injury and to prevent damage to the equipment, before removing the access panel, make sure that the server is powered down, all cables are disconnected from the back of the server, and the power cord is disconnected from the grounded (earthed) AC outlet. NOTE: The drive trays in the removable media - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 23
2-10 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide ATA Hard Drive Compartment (ProLiant ML330e Server) To remove an ATA hard drive compartment from the ProLiant ML330e server: 1. Complete the preparation procedures. See "Preparation Procedures" earlier in this chapter. 2. Remove - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 24
Removal and Replacement Procedures 2-11 5. Remove the three shipping screws , squeeze the two spring clips , and then pull the drive compartment from the chassis . 2 2 3 1 1 Figure 2-7. Removing an ATA hard drive compartment To replace an ATA hard drive compartment, reverse steps 2 through 5. - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 25
2-12 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide SCSI Hard Drive Compartment (ProLiant ML330 Server) To remove a SCSI hard drive compartment from the ProLiant ML330 server: 1. Complete the preparation procedures. See "Preparation Procedures" earlier in this chapter. 2. Remove - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 26
Removal and Replacement Procedures 2-13 5. Remove the three shipping screws , squeeze the two spring clips , and then pull the drive compartment from the chassis . 2 2 3 1 1 Figure 2-9. Removing a SCSI hard drive compartment To replace a SCSI hard drive compartment, reverse steps 2 through 5. - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 27
2-14 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Hard Drives To remove a hard drive from 3. Remove the access panel. See "Access Panel" earlier in this chapter. 4. Disconnect all the power and data cables from the back of all drives on the hard drive compartment. 5. Remove the - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 28
Removal and Replacement Procedures 2-15 Power Switch IMPORTANT: To completely remove all power from the system, you must disconnect the power cord from the server. To remove the power switch: 1. Complete the preparation procedures. See "Preparation Procedures" earlier in this chapter. 2. Remove the - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 29
2-16 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide 5. From the front of the chassis, squeeze the sides of the power switch to disengage the two retainer clips from the chassis , and then gently remove the power switch from the chassis . 6. Also from the front of the chassis, - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 30
panel. See "Access Panel" earlier in this chapter. 4. Disconnect the fan power cable from the system board fan connector . 5. Use a Phillips screwdriver to remove the four mounting screws from the rear of the server . 6. Pull the fan out and away from the chassis . 2 3 1 Figure 2-13. Removing the - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 31
2-18 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Cable Routing Diagrams Figure 2-14 through Figure 2-18 show cable routing diagrams for the ProLiant ML330e/ML330 server. 1 2 Figure 2-14. Diskette drive cable and IDE CD-ROM drive cable routing Table 2-2 Diskette Drive Cable - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 32
Removal and Replacement Procedures 2-19 Figure 2-15. Server Management Information Cable (SMIC) routing (ProLiant ML330e server) Figure 2-16. Server Management Information Cable (SMIC) routing (ProLiant ML330 server) - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 33
2-20 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Figure 2-17. ATA cable routing (ProLiant ML330e server) Figure 2-18. Integrated Wide Ultra2 SCSI cable routing (ProLiant ML330 server) - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 34
Removal and Replacement Procedures 2-21 Processor with Heatsink To remove a processor with heatsink: CAUTION: Electrostatic discharge (ESD) can damage electronic access panel. See "Access Panel" earlier in this chapter. 4. Unplug the processor fan from the system board. Figure 2-19. Unplugging the - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 35
2-22 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide 5. Press down and release the heatsink retainer clip to disengage one side from the processor socket . 6. Unhook the opposite side of the heatsink retainer clip from the processor socket , and then lift the heatsink/fan assembly - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 36
Removal and Replacement Procedures 2-23 Memory Modules The ProLiant ML330e/ML330 server supports 64-, 128-, 256-, or 512-MB PC 133-MHz Registered error checking and correcting (ECC) synchronous dynamic random access memory (SDRAM) dual inline memory modules (DIMMs). CAUTION: Electrostatic discharge - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 37
2-24 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide NOTE: Memory modules do not need to be installed in pairs and can be installed in any available socket. 1 2 3 4 Figure 2-21. Memory module socket locations Table 2-3 Memory Module Socket Locations Item Description Socket 1 - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 38
. See "Front Bezel" earlier in this chapter. 3. Remove the access panel. See "Access Panel" earlier in this chapter. 4. Press outward on both latches of the memory module socket at the same time . This step releases the DIMM and pushes it partially out of the socket. 5. Lift the - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 39
2-26 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Expansion Slots 1 2 3 4 5 6 Figure 2-23. Expansion slot locations Table 2-4 Expansion Slots Item Description 64-bit PCI (half-length) 64-bit PCI 32-bit PCI (Server Feature Board) 32-bit PCI 32-bit PCI 32-bit PCI Slot - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 40
4. Disconnect any cables connected to the Server Feature Board. 5. Remove the screw securing the Server Feature Board to the chassis , and then pull the Server Feature Board out of the server . 1 2 Figure 2-24. Removing the Server Feature Board NOTE: The Server Feature Board is located only in slot - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 41
2-28 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Expansion Board Guide To remove the expansion board guide: 1. chapter. 4. Remove all expansion boards supported by the board guide. 5. Push in the four locking tabs , and then pull the guide back and away from the chassis . - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 42
Removal and Replacement Procedures 2-29 System Board CAUTION: Electrostatic discharge (ESD) can damage electronic components. Be sure that you are properly grounded (earthed) before beginning any installation procedure. See "Electrostatic Discharge Information" earlier in this chapter for more - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 43
2-30 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Power Supply To remove the power supply: WARNING: To reduce the risk of electric shock or damage to the equipment: Unplug the power cord before removing the power supply from the server. Install the power supply before connecting - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 44
ProLiant ML330e/ML330 server has nonvolatile memory, which requires a battery to retain system information. There is a battery on the system board and a battery on the Server server no longer automatically displays the correct date and time, you may need to replace the battery that provides power - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 45
2-32 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide 4. Locate the battery on the system board, and then slide the battery out of the holder. 5. Slide the replacement battery into the proper position with - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 46
(+) polarity must be positioned up. 7. Replace the Server Feature Board, front panel, and bezel. 8. Connect the server and power up. 9. For the ProLiant ML330 server, run the BIOS Setup utility to reconfigure your system. 10. For the ProLiant ML330e server, run the RBSU to reconfigure your system. - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 47
3 Chapter Diagnostics Tools This chapter provides an overview of the software and firmware diagnostics tools available for the Compaq ProLiant ML330e/ML330 server. - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 48
Power-On Self-Test (POST). For a complete list of POST error messages, see the Compaq Servers Troubleshooting Guide. Compaq Diagnostics software is also available on the Compaq SmartStart and Support Software CD. A Diagnostics diskette can be created from the SmartStart and Support Software CD - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 49
. For a complete list of ADU error messages, see the Compaq Servers Troubleshooting Guide. The IML requires Compaq operating system-dependent drivers. Refer to the Compaq Software Support CD for instructions on installing the appropriate drivers. The BIOS Setup utility is loaded during POST if F10 - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 50
3-4 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Table 3-1 Diagnostics Tools continued Tool What it is ROM Based Setup Utility (RBSU) for the ProLiant ML330e server Utility used to configure some hardware installed in or connected to the server. Specifically, it can: - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 51
Diagnostics Tools 3-5 For More Information For detailed information about each of these diagnostics tools, see the Compaq Servers Troubleshooting Guide on the documentation CD. For the most recent version of this guide, go to the Compaq website: http://www.compaq.com - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 52
4 Chapter Connectors, Switches, and LED Indicators This chapter contains illustrations and tables identifying connectors, switches, and LED locations on the rear panel, Server Feature Board, and system board for the Compaq ProLiant ML330e/ML330 server. - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 53
4-2 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Connectors This section contains graphics and tables identifying connector locations on the system board, rear panel, and Server Feature Board for the Compaq ProLiant ML330e/ML330 server. System Board Components 15 14 16 13 - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 54
bit PCI slot 1 (half-length) Battery System fan connector Processor Serial port connector B Parallel port connector Serial port connector A USB ports (ProLiant ML330e server only) Item Description Mouse connector Keyboard connector Power supply connector Diskette drive connector DIMM slots - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 55
4-4 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Rear Panel Connectors 1 2 3 4 5 6 7 8 9 Figure 4-2. Rear panel connectors Table 4-2 Rear Panel Connectors Item Description Item Description Power cord Serial ports Voltage selector switch Parallel port Mouse RJ-45 - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 56
, Switches, and LED Indicators 4-5 Server Feature Board Components (ProLiant ML330e Server) 2 1 9 3 8 4 7 6 5 Figure 4-3. Server Feature Board components (ProLiant ML330e server) Table 4-3 Server Feature Board Components (ProLiant ML330e Server) Item Description ATA channel connector - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 57
4-6 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Server Feature Board Components (ProLiant ML330 Server) 2 1 9 3 8 4 7 6 5 Figure 4-4. Server Feature Board components (ProLiant ML330 server) Table 4-4 Server Feature Board Components (ProLiant ML330 Server) Item - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 58
tables showing switch locations on the ProLiant ML330e/ML330 server system board and Server Feature Board. Reserved Processor Switch Settings (SW1) on 12 3 4 Figure 4-5. Reserved processor switch settings (SW1) Switch 1 2 3 4 Table 4-5 Reserved Processor Switch Settings (SW1) Default Off Off - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 59
4-8 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide System Configuration Switch Settings (SW2) on 12 3 4 Figure 4-6. System configuration switch settings = Password disabled Off = Normal On = When server is powered up, all system configuration information is erased. Off = Normal - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 60
is disabled IMPORTANT: Positions 2 through 8 are reserved for Compaq authorized service providers only. Do not change these switches from the indicated default settings. NOTE: For information on troubleshooting video problems, refer to "Video Problems" in the Compaq Servers Troubleshooting Guide. - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 61
4-10 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Voltage Regulator Switch Set the voltage regulator switch to either 115 volts or 230 volts, as appropriate for your location. 115 230 Figure 4-8. Voltage regulator switch location - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 62
System Status LEDs 1 2 3 Figure 4-9. System status power button LEDs Table 4-8 System Status LEDs Item Power button Power status Hard drive activity status Status System on System on, AC power OK. Do not remove power from system. System off, no AC power Drive being accessed Drive not being - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 63
4-12 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Network Controller LEDs 1 23 Figure 4-10. Network controller LEDs Table 4-9 Network Controller LEDs Item Description Status Condition Speed Off 10Base-T 10-Mbps (10Base-T Ethernet) On - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 64
provides specifications for the Compaq ProLiant ML330e/ML330 server. The following specifications are provided: System Unit Memory 1.44-MB Diskette Drive IDE CD-ROM Drive Wide Ultra2 SCSI Hard Drives for the ProLiant ML330 Server ATA Hard Drives for the ProLiant ML330e Server Integrated 10/100 Wake - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 65
5-2 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide System Unit Table 5-1 System Unit Specifications Dimensions Height Width voltage Rated input frequency Rated input current Power supply output power Rated steady state power BTUs for tower model Temperature range Operating - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 66
Table 5-2 Memory Specifications 64-, 128-, 256-, and 512-MB, and 1-GB PC 133-MHz ECC Registered SDRAM DIMMs 1.44-MB Diskette Drive Table 5-3 1.44-MB Diskette Drive Specifications Size LED indicators (front panel) Read/write capacity per diskette (high/low density) Drives supported Drive height - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 67
5-4 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide IDE CD-ROM Drive Applicable disk Capacity Rotational speed Block size Dimensions Height Width Depth Weight Data transfer rate Sustained Burst Interface Access times (typical) Full stroke - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 68
25 nm Divergence angle 53.5° ± 1.5° Output power 0.14 mW Operating conditions Temperature 5°C to 45°C (41°F to 113°F) Humidity 5% to 90% (10% to 80%) ATA Hard Drives (ProLiant ML330e Server) Table 5-5 ATA Hard Drive (ProLiant ML330e Server) Specifications Capacity Height Width Interface - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 69
5-6 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Wide Ultra2 SCSI Hard Drives (ProLiant ML330 Server) Table 5-6 Wide Ultra2 SCSI Hard Drive (ProLiant ML330 Server) Specifications Capacity Height Width Interface Transfer rate synchronous (max) Seek time (typical, including - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 70
LAN NIC Specifications Network interface Compatibility Data transfer method Network transfer rate Connector I/O address and interrupt Compliance OS support (ProLiant ML330 server) OS support (ProLiant ML330e server) 10Base-T/100Base-TX IEEE 802.2, 802.3, 802.3u 32-bit, PC 33-MHz bus master 10/100 - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 71
5-8 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Integrated Ultra ATA 100 Controller Table 5-9 Integrated Ultra ATA 100 Controller Specifications Protocol Drives supported Data transfer method Maximum transfer rate per PCI Bus (peak) ATA channel transfer rate ATA connectors - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 72
memory modules 2-23 overheating vi power fluctuations 2-4 power supply 2-30 proper cooling 2-4 ventilation clearances vi CD-ROM drive cable routing, illustrated 2-18 CD-ROM drive, part number 1-5 CE Mark-compliant power supply See power supply chassis, part number 1-3 clamps, part number 1-3 Compaq - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 73
2 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide compartment ATA hard drive removing 2-10 replacing 2-11 hard drive, part number 1-3 SCSI hard drive, removing 2-12 component-level repairs, warning vi, 2-4 cooling, caution 2-4 country kit, part number 1-6 D data transfer rate 32- - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 74
ProLiant ML330 server), cable routing 2-20 LEDs, removing 2-16 mechanical parts, exploded view 1-2 memory module 2-25 removing 2-25 socket locations 2-24 network controller LEDs 4-12 power supply, removing 2-30 power switch cable, disconnecting 2-15 power switch, removing 2-16 Index 3 processor fan - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 75
4 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide K keyboard, part number 1-6 kits country 1-6 hardware 1-3 plastics, miscellaneous 1-3 power cable 1-6 return 1-6 signal cable 1-6 L labels, symbols on equipment 2-3 LEDs described 4-11 network controller status 4-11 removing 2-16 - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 76
2-3 power supply caution 2-30 part number 1-5 removing 2-30 removing, illustrated 2-30 replacing 2-30 power switch removing 2-15 removing, illustrated 2-16 replacing 2-16 power switch cable disconnecting, illustrated 2-15 powering down, server 2-4 preparing for service procedure 2-4 processor fan - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 77
6 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide specifications CD-ROM drive access times 5-4 capacity 5-4 data power supply output 5-2 temperature operating range 5-2 voltage input 5-2 weight 5-2 width 5-2 Ultra ATA 100 controller data transfer method 5-8 drives supported - Compaq ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Service Gui - Page 78
Socket Locations 2-24 Memory Specifications 5-3 Network Controller LEDs 4-12 Rear Panel Connectors 4-4 Reserved Processor Switch Settings (SW1) 4-7 Server Feature Board Components (ProLiant ML330 Server) 4-6 Server Feature Board Components (ProLiant ML330e Server) 4-5 Server Feature Board Switch
ProLiant ML330e/ML330 Server
Maintenance and Service Guide
Fourth Edition (March 2001)
Part Number 174623-004
Spare Part Number 176670-001
Compaq Computer Corporation