- Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 1
Microsoft Windows Event ID and SNMP Traps Reference Guide For use with SmartStart version 8.25 Part number: 347870-009 Ninth edition: June 2009 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 2
products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or standard commercial license. Microsoft®, Windows®, Windows NT®, and Windows Server® are U.S. registered trademarks of Microsoft Corporation. - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 3
-774 ...29 Event Identifiers 1061-1098 ...32 Event Identifiers 1101-1199 ...38 Event Identifiers 1200-1294 ...64 Event Identifiers 1343-4613 ...77 Server agents...82 Event Identifiers 256-774 ...82 Event Identifiers 1024-1092 ...85 Event Identifiers 1103-1183 ...93 Event Identifiers 1539-3352 ...124 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 4
00-Success 01-Informational 10-Warning 11-Error C-The customer code flag R-A reserved bit Facility-The facility code (always "CPQ") Code-The facility's status code-the event number; the upper byte refers to the HP Insight Management Agent that served the event, the lower byte is the actual - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 5
In addition to this guide, the following information sources are available: • User documentation • HP Insight Manager software Telephone numbers For the name of the nearest HP authorized reseller: • In the United States, see the HP US service locator webpage, http://www.hp.com/service_locator. • In - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 6
insertion string is: %1. The data contains the error code. Event identifier: cpqhsmsg.dll - 257 (Hex)0x84350101 (Service Event) Log Severity: Warning (2) Log Message: The Foundation Agents service could not allocate memory. The data contains the error code. Event identifier: cpqhsmsg.dll - 258 (Hex - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 7
not stop agent "%1". The data contains the error code. Event identifier: cpqhsmsg.dll - 270 (Hex)0x8435010e (Service Event) Log Severity: Warning (2) Log Message: The Foundation Agents service could not terminate agent "%1". The data contains the error code. Event identifier: cpqhsmsg.dll - 271 (Hex - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 8
service. Please install the SNMP service to enabled remote management of the server. Event identifier: cpqhsmsg.dll - 768 (Hex)0x84350300 (Service %1. The data contains the error code. Event identifier: cpqhsmsg.dll - 772 (Hex)0xc4350304 (Service Event) Log Severity: Error (3) Log Message: The Host - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 9
.MIB Symptom: An application has generated an exception. Specific error information is contained in the variable cpqHoSwPerfAppErrorDesc. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHoSwPerfAppErrorDesc Supporting SNMP Trap Description: "[cpqHoSwPerfAppErrorDesc]" NT Event ID: 1162 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 10
within the variable list are those of the alarm entry that generated this trap. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqMeAlarmVariable • cpqMeAlarmSampleType • cpqMeAlarmValue • cpqMeAlarmFallingThreshold • cpqMeAlarmOwner • cpqMeAlarmSeverity • cpqMeAlarmExtendedDescription - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 11
of the alarm entry that generated this trap. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • process has either started or stopped running. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHoSwRunningTrapDesc Supporting SNMP Trap Description: "[cpqHoSwRunningTrapDesc]" NT Event - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 12
any time the condition of a cluster resource has failed. User Action: Make a note of the cluster resource name, and then check the resource for the cause of the failure. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqClusterResourceName Supporting SNMP Trap Description: "Cluster resource - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 13
SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqClusterNodeName Supporting SNMP Trap Description: "Cluster service on [cpqClusterNodeName] has become degraded." NT Event ID: 1172 (Hex)0xc4350494 (cpqhsmsg.dll) Log Severity: Error (3) Log Message: The cluster service on %4 has failed. SNMP Trap - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 14
(cpqhsmsg.dll) Log Severity: Error (3) Log Message: The Processor Performance Instance, '%4' is failed with Processor Time of %5 percent. SNMP Trap: cpqOsCpuTimeFailed - 19002 in CPQWINOS.MIB Symptom: The Processor Time performance property is set to critical. Supporting SNMP Trap Data: • sysName - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 15
.dll) Log Severity: Error (3) Log Message: The PagingFile Performance Instance, '%4' is failed with PagingFile Usage of %5 percent. SNMP Trap: cpqOsPageFileUsageFailed - 19006 in CPQWINOS.MIB Symptom: The PagingFile Usage performance property is set to critical. Supporting SNMP Trap Data: • sysName - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 16
." NT Event ID: 1181 (Hex)0xc435049d (cpqhsmsg.dll) Log Severity: Error (3) Log Message: '%4' SNMP Trap: cpqHoCriticalSoftwareUpdateTrap - 11014 in CPQHOST.MIB Symptom: This trap is sent to notify the user of a Critical Software Update. Supporting SNMP Trap Data: • sysName Foundation agents 16 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 17
• cpqHoCriticalSoftwareUpdateData Supporting SNMP Trap Description: "[cpqHoCriticalSoftwareUpdateData]" Event identifier: cpqhsmsg.dll - 1792 (Hex)0x84350700 (Service Event) Log Severity: Warning (2) Log Message: The agent is unable to generate traps due to an error during initialization - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 18
Log Severity: Warning (2) Log Message: Unable to create thread. This error can be caused by a low memory condition. Rebooting the server may correct this error. Event identifier: cpqhsmsg.dll - 2098 (Hex)0x84350832 (Service Event) Log Severity: Warning (2) Log Message: Unable to acquire file system - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 19
Log Message: Unable to acquire the current process list. This error can be caused by a low memory condition. Rebooting the server may correct this error. Event identifier: cpqhsmsg.dll - 2101 (Hex)0x84350835 (Service Event) Log Severity: Warning (2) Log Message: Unable to acquire the CPU performance - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 20
there is an adequate amount of free memory. Event identifier: cpqhsmsg.dll - 2356 (Hex)0x84350934 (Service Event) Log Severity: Warning (2) Log Message: "%1". The data contains the error code. Event identifier: cpqhsmsg.dll - 2357 (Hex)0x84350935 (Service Event) Log Severity: Warning (2) Log Message - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 21
Message: Could not read from the registry sub-key. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqhsmsg.dll - 3073 (Hex)0x84350c01 (Service Event) Log Severity: Warning (2) Log Message: Could not create the - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 22
Message: Could not read from the registry sub-key. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqhsmsg.dll - 3842 (Hex)0x84350f02 (Service Event) Log Severity: Warning (2) Log Message: Could not write the - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 23
: Could not enumerate all of the nodes in the cluster. The data contains the error code. Event identifier: cpqhsmsg.dll - 3857 (Hex)0x84350f11 (Service Event) Log Severity: Warning (2) Log Message: Could not get the cluster's status. The Cluster service may not be running. Try to restart the Cluster - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 24
only supports the disk resource class. Event identifier: cpqhsmsg.dll - 3874 (Hex)0x84350f22 (Service Event) Log Severity: Warning (2) Log Message: Could not read the registry sub-key: "%1". This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 25
Event) Log Severity: Warning (2) Log Message: The External Status MIB Agent could not allocate memory. The data contains the error code. Event identifier: cpqhsmsg.dll - 4353 (Hex)0x84351101 (Service Event) Log Severity: Warning (2) Log Message: The External Status MIB Agent could not open the - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 26
the system type. The data contains the error code. Event identifier: cpqhsmsg.dll - 4402 (Hex)0x84351132 (Service Event) Log Severity: Warning (2) Log there is an adequate amount of free memory. Event identifier: cpqhsmsg.dll - 4405 (Hex)0x84351135 (Service Event) Log Severity: Warning (2) Log - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 27
be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqhsmsg.dll - 4623 (Hex)0x8435120f (Service Event) Log Severity: Warning (2) Log Message: The Agent could not access WMI. The WMI support may have not been started or installed - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 28
or may still be in the starting state. Event identifier: cpqhsmsg.dll - 4626 (Hex)0x84351212 (Service Event) Log Severity: Warning (2) Log Message: The Agent failed to process the MOF file to get the data from WMI. Problem with WMI service or MOF file or wrong file paths used. Foundation agents 28 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 29
The insertion string is: %1. The data contains the error code. Event identifier: cpqstmsg.dll - 257 (Hex)0x84350101 (Service Event) Log Severity: Warning (2) Log Message: The Storage Agents service could not allocate memory. The data contains the error code. Event identifier: cpqstmsg.dll - 258 (Hex - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 30
terminate agent "%1". The data contains the error code. Event identifier: cpqstmsg.dll - 271 (Hex)0x8435010f (Service Event) Log Severity: Warning (2) Log Message: The Storage Agents service could not unload the module "%1". The data contains the error code. Event identifier: cpqstmsg.dll - 272 (Hex - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 31
by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqstmsg.dll - 526 (Hex)0x8435020e (Service Event) Log Severity: Warning (2) Log Message: Unsupported storage system. The ProLiant storage system %1 is not supported by this version of the - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 32
574 (Hex)0x8435023e (Service Event) Log Severity: Warning (2) Log Message: The Drive Array Agent failed to get capacity on SCSI drive because %1. The data contains the error code. Event identifier: cpqstmsg.dll - 772 (Hex)0xc4350304 (Service Event) Log Severity: Error (3) Log Message: The Remote - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 33
• cpqDaLogDrvStatus Supporting SNMP Trap Description: "Status is now [cpqDaLogDrvStatus]." NT Event ID: 1063 (Hex)0xc4350427 (cpqstmsg.dll) Log Severity: Error (3) Event current spare drive status. User Action: If the spare drive status is failed, replace the drive. Supporting SNMP Trap Data: • - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 34
Supporting SNMP Trap Description: "Physical Drive Status is now [cpqDaPhyDrvStatus]." NT Event ID: 1065 (Hex)0xc4350429 (cpqstmsg.dll) Log Severity: Error cpqDaAccelStatus. User Action: If the accelerator board status is permDisabled(5), you may need to replace the accelerator board. Supporting SNMP - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 35
accelerator cache board that has lost battery power. If data was being stored in the accelerator cache memory when the server lost power, that data has been lost. User Action: Verify that no data has been lost. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrSlot • cpqDaCntlrModel - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 36
SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqScsiCntlrStatus Supporting SNMP Trap Description: "Status is now [cpqScsiCntlrStatus]." NT Event ID: 1069 (Hex)0xc435042d (cpqstmsg.dll) Log Severity: Error (3) Event Title: SCSI Logical Drive Status Change. Log Message: The SCSI logical drive - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 37
system. The variable cpqSsBoxFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsBoxFanStatus Supporting SNMP Trap Description: "Storage System fan status changed to - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 38
by the administrator. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsBoxTempStatus Supporting SNMP Trap Description: "Storage System temperature ok." Event identifier: cpqstmsg.dll - 1098 (Hex)0x4435044a (Service - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 39
degraded status. Restore power or replace any failed power supply. SNMP Trap: cpqSs4PwrSupplyDegraded - 8015 in CPQSTSYS.MIB Symptom: A storage system power supply status has been set to degraded. User Action: Restore power or replace any failed storage system power supply. Supporting SNMP Trap Data - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 40
• cpqHoTrapFlags • cpqSsBoxFltTolPwrSupplyStatus Supporting SNMP Trap Description: "A storage system power supply unit has become degraded." NT Event ID: 1107 (Hex)0xc4350453 (cpqstmsg.dll) Log Severity: Error (3) Event Title: SCSI Tape Drive Status Change. Log Message: The tape drive with SCSI - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 41
been set to degraded. User Action: The drive should be scheduled for replacement. For detailed information on a component replacement, see the appropriate Maintenance and Service Guide. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqIdeIdentIndex Supporting SNMP Trap Description: "IDE - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 42
NT Event ID: 1145 (Hex)0xc4350479 (cpqstmsg.dll) Log Severity: Error (3) Event Title: External Array Logical Drive Status Change. Log Message: Logical status. User Action: If the physical drive status is threshExceeded(4), predictiveFailure(5) or failed(6), replace the drive. Supporting SNMP Trap - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 43
associated with this drive. User Action: If the spare drive status is failed, replace the drive. Supporting SNMP Trap Data: • Supporting SNMP Trap Description: "Spare Status is now [cpqFcaSpareStatus] on bus [cpqFcaSpareBusNumber]." NT Event ID: 1148 (Hex)0xc435047c (cpqstmsg.dll) Log Severity: Error - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 44
Accelerator Cache Board that has lost battery power. If data was being stored in the accelerator memory when the system lost power, that data has been lost. User Action: Verify that no data has been lost. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 45
cpqFcaCntlrStatus indicates the current controller status. User Action: If the controller status is offline(4), access to the storage box has been lost. Check the storage box and all fibre channel connections for problems. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 46
system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsPowerSupplyStatus indicates the current status. User Action: If the power supply status is failed, restore power or replace the failed power supply. Supporting SNMP - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 47
Supporting SNMP Trap Description: "Storage system power supply indicates the current status. User Action: If the error. SNMP Trap: cpqTape3LibraryFailed - 5010 in CPQSCSI.MIB Symptom: Tape Library Error. The Insight Agent has detected that an autoloader unit has encountered an error. Supporting - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 48
connected to SCSI bus %5 of the controller in slot %4 has recovered from errors. SNMP Trap: cpqTape3LibraryOkay - 5011 in CPQSCSI.MIB Symptom: Tape Library Okay has recovered from errors. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqTapeLibrarySerialNumber Supporting SNMP Trap - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 49
SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqTapeLibrarySerialNumber Supporting SNMP Trap Description: "Tape library [cpqTapeLibrarySerialNumber] door closed." NT Event ID: 1161 (Hex)0xc4350489 (cpqstmsg.dll) Log Severity: Error (3) Event Title: SCSI CD Library Status Change. Log Message - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 50
active controller slot, and cpqDaCntlrPartnerSlot indicates the backup. User Action: Check the partner controller for problems. If this was the result of a user initiated switchover, no action is required. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrSlot • cpqDaCntlrPartnerSlot - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 51
world wide name associated with this controller. User Action: If the tape controller status is offline, access to the tape library and tapes has been lost. Check the tape library and all Fibre connections for problems. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcTapeCntlrWWN - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 52
cpqFcTapeLibraryScsiTarget indicates the SCSI ID of the tape library. User Action: If the tape library door is open, close the tape library door. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcTapeCntlrWWN • cpqFcTapeLibraryScsiBus • cpqFcTapeLibraryScsiTarget • cpqFcTapeLibraryScsiLun - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 53
variable cpqFcaCntlrBoxIoSlot indicates the new active controller index. User Action: Check the partner controller for problems. If this was the result of a user initiated switchover, no action is required. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 54
variable cpqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library. User Action: If the tape library door is open, close the tape library door. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaTapeLibraryCntlrIndex • cpqDaTapeLibraryScsiBus • cpqDaTapeLibraryScsiTarget Storage - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 55
cpqDaTapeDrvScsiIdIndex indicates the SCSI ID of the tape drive. User Action: If the tape is failed, check the tape and all SCSI connections. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaTapeDrvCntlrIndex • cpqDaTapeDrvBusIndex • cpqDaTapeDrvScsiIdIndex • cpqDaTapeDrvLunIndex - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 56
Channel Host Controller. The variable cpqFcaHostCntlrStatus indicates the current controller status. User Action: If the controller status is failed, replace the controller. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcaHostCntlrSlot • cpqFcaHostCntlrStatus • cpqFcaHostCntlrModel - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 57
drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If the physical drive status is smartError(3) or failed(4), replace the drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqIdeAtaDiskControllerIndex • cpqIdeAtaDiskIndex • cpqIdeAtaDiskModel - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 58
fan status. User Action: If the fan status is degraded or failed, replace any failed fans. Supporting SNMP Trap the temperature in a storage system. The variable cpqSsBackplaneTempStatus indicates the current status. User Action: If the temperature status is degraded or failed, shut down the storage - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 59
agent has detected a change in the power supply status of a storage system. The variable cpqSsBackplaneFtpsStatus indicates the current status. User Action: If the power supply status is degraded, restore power or replace the failed power supply. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 60
Tape Drive. The variable cpqFcTapeDriveStatus indicates the current tape status. User Action: If the tape is failed or is offline, check the tape and all connections. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcTapeDriveCntlrIndex • cpqFcTapeDriveScsiBus • cpqFcTapeDriveScsiTarget - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 61
tape inserted and run. This causes the tape drive heads to be cleaned. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcTapeDriveCntlrIndex • cpqFcTapeDriveScsiBus • cpqFcTapeDriveScsiTarget • cpqFcTapeDriveScsiLun • cpqFcTapeDriveModel • cpqFcTapeDriveFWRev • cpqFcTapeDriveSerialNumber - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 62
indicates the current status. User Action: If the RSO status is noSecondary(6) or linkDown(7), Be sure that the secondary server is operational and that all secondaryRunningAuto(8) or secondaryRunningUser(9), examine the primary server for failed components. Supporting SNMP Trap Data: • sysName • - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 63
variable cpqFcTapeLibraryDoorStatus indicates the current tape library door status. User Action: If the tape library door is open, close the tape library door. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcTapeLibraryCntlrIndex • cpqFcTapeLibraryScsiBus • cpqFcTapeLibraryScsiTarget - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 64
User Action: If the board status is generalFailure(3), you may need to replace the controller. If the board status is cableProblem(4), check the cable connections between the controller and the storage system. Supporting • cpqDaCntlrFWRev • cpqDaAccelTotalMemory Supporting SNMP Trap Description: " - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 65
. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If the physical drive status is failed(3) or predictive Failure(4), replace the drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaPhyDrvCntlrIndex • cpqDaPhyDrvIndex - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 66
with one of the physical drive objects on a drive array has been exceeded. User Action: Replace the physical drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaPhyDrvCntlrIndex • cpqDaPhyDrvIndex • cpqDaPhyDrvBusNumber • cpqDaPhyDrvBay • cpqDaPhyDrvModel - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 67
If data was being stored in the accelerator cache memory when the server lost power, that data has been lost. User Action: Verify that no data has been lost. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaCntlrModel • cpqDaAccelCntlrIndex • cpqDaAccelSerialNumber - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 68
status. The variable cpqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library. User Action: If the tape library door is open, close the tape library door. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaTapeLibraryCntlrIndex • cpqDaTapeLibraryScsiBus - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 69
cpqDaTapeDrvScsiIdIndex indicates the SCSI ID of the tape drive. User Action: If the tape is failed, check the tape and all SCSI connections. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaTapeDrvCntlrIndex • cpqDaTapeDrvBusIndex • cpqDaTapeDrvScsiIdIndex - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 70
change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Storage agents 70 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 71
User Supporting SNMP Trap Description: "Storage System temperature status changed to [cpqSsBoxTempStatus]." NT Event ID: 1214 (Hex)0x843504be (cpqstmsg.dll) Log Severity: Warning (2) Event Title: Storage System Fault Tolerant Power Supply Status Change. Log Message: The fault tolerant power supply - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 72
User Action: If the power supply status is degraded, restore power or replace the failed power supply. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsBoxCntlrHwLocation • cpqSsBoxCntlrIndex • cpqSsBoxBusIndex • cpqSsBoxVendor • cpqSsBoxModel • cpqSsBoxSerialNumber • - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 73
spare drive. The variable cpqDaSpareStatus indicates the current spare drive status. User Action: If the spare drive status is failed, replace the drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaSpareCntlrIndex • cpqDaSparePhyDrvIndex • cpqDaSpareStatus - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 74
a storage system. The variable cpqSsBoxFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsBoxCntlrHwLocation • cpqSsBoxCntlrIndex • cpqSsBoxBusIndex • cpqSsBoxVendor - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 75
has detected a change in the power supply status of a storage system. The variable cpqSsBoxFltTolPwrSupplyStatus indicates the current power supply status. User Action: If the power supply status is degraded, restore power or replace the failed power supply. Supporting SNMP Trap Data: • sysName - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 76
• cpqSasPhyDrvFWRev • cpqSasPhyDrvSerialNumber • cpqSasPhyDrvSasAddress Supporting SNMP Trap Description: "Status is error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqstmsg.dll - 1282 (Hex)0x84350502 (Service Event - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 77
caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqstmsg.dll - 1294 (Hex)0x8435050e (Service Event) Log Severity: Warning (2) Log Message: Unsupported storage system. The ProLiant storage system %1 is unsupported by this version - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 78
problem. Event identifier: cpqstmsg.dll - 1803 (Hex)0xc435070b (Service Event) Log Severity: Error (3) Log Message: Unable to load a required library. This error by a failure in the Remote Access Service or by a missing or invalid configuration. Use the HP Insight Management Agents control panel to - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 79
IDE Agent could not allocate memory. The data contains the error code. Event identifier: cpqstmsg.dll - 3585 (Hex)0x84350e01 (Service Event) Log Severity: Warning (2) Log Message: The IDE Agent could not open the base of the registry. The data contains the error code. Event identifier: cpqstmsg.dll - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 80
Log Message: Could not write the registry subkey: "%1". This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqstmsg.dll - 4099 (Hex)0x84351003 (Service Event) Log Severity: Warning (2) Log Message: Could not read - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 81
Log Message: Could not write the registry subkey: "%1". This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqstmsg.dll - 4611 (Hex)0x84351203 (Service Event) Log Severity: Warning (2) Log Message: Could not read - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 82
Server Agents service detected an error. The insertion string is: %1. The data contains the error code. Event identifier: cpqsvmsg.dll - 257 (Hex)0x84350101 (Service Event) Log Severity: Warning (2) Log Message: The Server Agents service could not allocate memory. The data contains the error code - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 83
Log Severity: Warning (2) Log Message: The Server Agents service could not load the module "%1". The data contains the error code. Event identifier: cpqsvmsg.dll - 265 (Hex)0x84350109 (Service Event) Log Severity: Warning (2) Log Message: The Server Agents service could not get the control function - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 84
Log Severity: Error (3) Log Message: The Server Agents service encountered a fatal error. The service is terminating. The data contains the error code. Event identifier: cpqsvmsg.dll - 400 (Hex)0x44350190 (Service Event) Log Severity: Information (1) Log Message: The Server Agents service version %1 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 85
- 6047 in CPQHLTH.MIB Symptom: Advanced Memory Protection Online Spare Engaged. The Advanced Memory Protection subsystem has detected a memory fault. The Online Spare Memory has been activated. User Action: Schedule server down time to replace the faulty memory. Supporting SNMP Trap Data: • sysName - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 86
SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "The Advanced Memory Protection subsystem has engaged the XOR memory." NT Event ID: 1029 (Hex)0x44350405 (cpqsvmsg.dll) Log Severity: Information (1) Log Message: The Fault Tolerant Power Supply Sub-system has returned to - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 87
: cpqHe5CorrMemReplaceMemModule - 6064 in CPQHLTH.MIB Symptom: Corrected Memory Errors Detected. The errors have been corrected, but the memory module should be replaced. Value 0 for CPU means memory is not processor-based. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHeResMem2BoardNum - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 88
sub-system board, cartridge, or riser bus error has been detected. Value 0 for CPU means memory is not processor-based. User Action: Replace the indicated board or cartridge or Riser. SNMP Trap Data: • sysName, • cpqHoTrapFlags • cpqHeResMem2BoardSlotNum • cpqHeResMem2BoardCpuNum Server agents 88 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 89
engine has been activated. For instruction on replacing the faulty memory, see the server documentation. SNMP Trap: cpqHeResilientMemLockStepMemoryEngaged - 6068 in CPQHLTH.MIB Symptom: Advanced Memory Protection LockStep Engine Memory Engaged. The Advanced Memory Protection subsystem has detected - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 90
- 6019 in CPQHLTH.MIB Symptom: The temperature status has been set to OK. The server's temperature has returned to the normal operating range. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "Temperature has returned to normal range." NT Event ID: 1085 (Hex - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 91
Supporting SNMP Trap Description: "System fan has returned to normal operation." NT Event ID: 1088 (Hex)0xc4350440 (cpqsvmsg.dll) Log Severity: Error . The server is shut down. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "CPU fan has failed. Server will be - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 92
Message: Post Errors were detected. One or more Power-On-Self-Test errors were detected during server startup. SNMP Trap: cpqHe3PostError - 6027 in CPQHLTH.MIB Symptom: One or more POST errors occurred. Power On Self-Test (POST) errors occur during the server restart process. Supporting SNMP Trap - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 93
- 6028 in CPQHLTH.MIB Symptom: The fault tolerant power supply sub-system condition has been set to degraded. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "The server power supply status has become degraded." NT Event ID: 1108 (Hex - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 94
Insight/ Integrated Lights-Out interface. The firmware is not responding. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "Server [sysName], Remote Insight/Integrated Lights-Out interface error." NT Event ID: 1112 (Hex)0x84350458 (cpqsvmsg.dll) Log Severity - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 95
. This trap is sent when cpqSeCpuThreshPassed transitions from false to true. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSeCpuSlot • cpqSeCpuSocketNumber Supporting SNMP Trap Description: "CPU internal corrected errors have passed a set threshold." NT Event ID: 1115 (Hex)0x8435045b - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 96
tolerant power supply condition has been set back to the OK state for the specified chassis and bay location. Supporting SNMP Severity: Warning (2) Log Message: Post Errors were detected. One or more Power-On-Self-Test errors were detected during server startup. SNMP Trap: cpqHe3PostError - 6027 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 97
cpqHoTrapFlags Supporting SNMP Trap Description: "Errors occurred during server restart." NT Event ID: 1124 (Hex)0x84350464 (cpqsvmsg.dll) Log Severity: Warning (2) Log Message: The Fault Tolerant Power Supply Sub-system is in a degraded state. Restore power or replace the failed power supply. SNMP - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 98
Fault Tolerant Power Supply Sub-system has lost redundancy. Restore power or replace any failed or missing power supplies. SNMP Trap: cpqHe3FltTolPowerRedundancyLost - 6032 in CPQHLTH.MIB Symptom: The Fault Tolerant Power Supplies have lost redundancy for the specified chassis. Supporting SNMP Trap - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 99
Symptom: A Fault Tolerant Power Supply has been removed from the specified chassis and bay location. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHeFltTolPowerSupplyChassis • cpqHeFltTolPowerSupplyBay Supporting SNMP Trap Description: "The Power Supply Removed on Chassis [ - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 100
Supporting SNMP Trap Description: "The Fan Removed on Chassis [cpqHeFltTolFanChassis], Fan [cpqHeFltTolFanIndex]." NT Event ID: 1134 (Hex)0xc435046e (cpqsvmsg.dll) Log Severity: Error and location. The system is shut down due to this condition. Supporting SNMP Trap Data: • sysName Server agents 100 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 101
has been set to OK in the specified chassis and location. The server's temperature has returned to the normal operating range. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHeTemperatureChassis • cpqHeTemperatureLocale Supporting SNMP Trap Description: "Temperature Normal on Chassis - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 102
Severity: Error (3) Log Message: The DC-DC power converter is in a failed state. Replace the power converter. SNMP Trap: cpqHe3PowerConverterFailed - 6044 in CPQHLTH.MIB Symptom: The DC-DC Power Converter condition has been set to failed for the specified chassis, slot, and socket. Supporting SNMP - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 103
has failed to power up in the specified chassis and slot. User Action: Be sure the board and all cables are installed correctly, and that the board type and revision are the same as the replaced board. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSiHotPlugSlotChassis Server agents 103 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 104
Supporting SNMP Trap Description: "Hot Plug Slot Board Failed in Chassis [cpqSiHotPlugSlotChassis], Slot [cpqSiHotPlugSlotIndex], Error the server User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackSerialNum • cpqRackTrapSequenceNum Supporting - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 105
Supporting SNMP Trap Description: "The enclosure name has changed to been removed from the rack. User Action: None. Supporting SNMP Trap Data: • • cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap been inserted into the rack. User Action: None. Supporting SNMP Trap Data: • - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 106
that an enclosure temperature sensor has been tripped, indicating an overheat condition. User Action: Shut down the enclosure and possibly the rack as soon as been blocked. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackCommonEnclosureName Server agents 106 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 107
that an enclosure fan has failed and that no other fans in the redundant fan group are operating. This may result in the enclosure overheating. User Action: Replace the fan as soon as possible. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName Server agents 107 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 108
This may result in the enclosure overheating. User Action: Replace the fan as soon as possible. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags . This trap indicates that an enclosure fan has returned to normal operation. User Action: None. Supporting SNMP Trap Data: • sysName Server agents 108 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 109
Enclosure Fan Inserted Log Message: The enclosure fan has been inserted. SNMP Trap: cpqRackEnclosureFanInserted - 22012 in CPQRACK.MIB Symptom: The enclosure fan has been inserted. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Server agents 109 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 110
trap indicates that a power supply has failed. SNMP Trap: cpqRackPowerSupplyFailed - 22013 in CPQRACK.MIB Symptom: The power supply status has been set to failed. This trap indicates that a power supply has failed. User Action: Replace the power supply as soon as possible. Supporting SNMP Trap Data - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 111
normal operation. SNMP Trap: cpqRackPowerSupplyOk - 22015 in CPQRACK.MIB Symptom: The power supply status has been set to OK. This trap indicates that a power supply has returned to normal operation. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 112
) Log Severity: Information (1) Event Title: Rack Power Supply Inserted Log Message: The power supply has been inserted. SNMP Trap: cpqRackPowerSupplyInserted - 22017 in CPQRACK.MIB Symptom: The power supply has been inserted. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 113
- 22019 in CPQRACK.MIB Symptom: The rack power supply detected an input line voltage problem. User Action: Check the power input for the power supply or replace any failed power supplies as soon as possible. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 114
. SNMP Trap: cpqRackPowerShedAutoShutdown - 22021 in CPQRACK.MIB Symptom: Server shutdown due to power shedding. The server blade was shut down due to a lack of power. User Action: Check power connections or add power supplies. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 115
Log Message: Inadequate power to power on. SNMP Trap: cpqRackServerPowerOnFailedNotEnoughPower - 22023 in CPQRACK.MIB Symptom: Inadequate power to power on. There is not enough power to power on the server blade. User Action: Check power connections or add power supplies. Supporting SNMP Trap Data - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 116
- 22024 in CPQRACK.MIB Symptom: Inadequate power to power on. There is not enough power to power on the server blade. The server enclosure micro-controller was not found. User Action: Check server enclosure connections or add power supplies. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 117
Title: Server Power On Via Manual Override Log Message: Server power on via manual override. SNMP Trap: cpqRackServerPowerOnManualOverride - 22026 in CPQRACK.MIB Symptom: Server power on via manual override. The server blade was powered on by a manual override. User Action: None. Supporting SNMP - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 118
from the enclosure. SNMP Trap: cpqRackServerBladeRemoved - 22028 in CPQRACK.MIB Symptom: Server blade removed. The server blade has been removed from the enclosure. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackServerBladeEnclosureName - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 119
Symptom: Power subsystem DC power problem. There is a power subsystem DC power problem for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName Server agents - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 120
.MIB Symptom: Unknown power consumption. There is an unknown power consumer drawing power. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid Server agents 120 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 121
number of power enclosures has been exceeded. User Action: Remove the extra power enclosure. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackCommonEnclosureName • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureTrapSequenceNum Server agents 121 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 122
contains the error code SNMP Trap: cpqHeManagementProcInReset - 6061 in CPQHLTH.MIB Symptom: The Management processor is currently in reset. The management processor is currently in the process of being reset because of a firmware update or some other event. User action: None Supporting SNMP Trap - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 123
'%5' attached. The data contains the error code. SNMP Trap: 1008 in CPQSTDEQ.MIB Symptom: The USB key is attached to the server. User Action: None required. Supporting SNMP Trap Data: • sysName, • cpqHoTrapFlags • cpqSeUSBDeviceType • cpqSeUSBDeviceName Supporting SNMP Trap Description: This trap is - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 124
can be caused by a corrupt or missing file. Reinstalling the Server Agents, the software support drivers, or running the Emergency Repair procedure may correct this error. Event identifier: cpqsvmsg.dll - 1544 (Hex)0x84350608 (Service Event) Log Severity: Warning (2) Log Message: Unable to read from - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 125
Message: Could not read from the registry sub-key. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqsvmsg.dll - 3330 (Hex)0x84350d02 (Service Event) Log Severity: Warning (2) Log Message: Could not write the - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 126
Log Message: Could not read the registry sub-key: "%1". This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqsvmsg.dll - 3333 (Hex)0x84350d05 (Service Event) Log Severity: Warning (2) Log Message: Could not read - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 127
error code. Event identifier: cpqsvmsg.dll - 5637 (Hex)0x84351605 (Service error code. Event identifier: cpqsvmsg.dll - 5639 (Hex)0x84351607 (Service error code. Event identifier: cpqsvmsg.dll - 5640 (Hex)0x84351608 (Service error code. Event identifier: cpqsvmsg.dll - 5641 (Hex)0x84351609 (Service - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 128
contains the error code. Event identifier: cpqsvmsg.dll - 5682 (Hex)0x84351632 (Service Event) Log contains the error code. Event identifier: cpqsvmsg.dll - 5683 (Hex)0x84351633 (Service Event) data contains the error code. Event identifier: cpqsvmsg.dll - 5684 (Hex)0x84351634 (Service Event) Log - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 129
Log Message: Could not create the registry key: "%1". This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqnimsg.dll - 263 (Hex)0x84350107 (Service Event) Log Severity: Warning (2) Log Message: Could not delete - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 130
to create thread. This error can be caused by a low memory condition. Rebooting the server may correct this error. Event identifier: cpqnimsg.dll - 271 (Hex)0x8435010f (Service Event) Log Severity: Warning (2) Log Message: Could not open the driver for device "%1". This error can be caused by an - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 131
drivers and team. Event identifier: cpqnimsg.dll - 274 (Hex)0x84350112 (Service Event) Log Severity: Warning (2) Log Message: The NIC Management Agent cannot generate Traps due to a communication problem contain the error code. Event identifier: cpqnimsg.dll - 285 (Hex)0x8435011d (Service Event) Log - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 132
: cpqnimsg.dll - 296 (Hex)0xc4350128 (Service Event) Log Severity: Error (3) Log Message: A driver for a NIC failed to open. This error can be caused by an improperly installed adapter. Removing and reinstalling all adapters may correct the problem. The NIC Agent service will not respond to any - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 133
not running. Starting WMI service or NIC agent might solve this problem. Event identifier: cpqnimsg.dll - 299 (Hex)0x8435012b (Service Event) Log Severity: Warning (2) Log Message: An attempt to query WMI for Virus Throttle event failed. The event data gives the error number. Event Identifiers 300 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 134
the Insight Agents may correct this problem. Event identifier: cpqnimsg.dll - 1033 (Hex)0x44350409 (Service Event) Log Severity: Information (1) Compaq Remote Insight Board trap due to processing error. The data contains the error code. Event identifier: cpqnimsg.dll - 1037 (Hex)0x8435040d (Service - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 135
. If this error persists, reinstalling the Insight Agents or the Remote Access Service may correct this error. For more information . User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement. Supporting SNMP - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 136
or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement. Supporting SNMP Trap Data: • sysName NIC agents 136 - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 137
a cable that was disconnected. User Action: None required. Supporting SNMP Trap Data: • sysName Supporting SNMP Trap Description: "Redundancy increased by adapter in slot [cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]." NT Event ID: 1293 (Hex)0xc435050D (cpqnimsg.dll) Log Severity: Error - Compaq ProLiant 7000 | Microsoft Windows Event ID and SNMP Traps Reference Guide - Page 138
adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqNicIfPhysAdapterSlot
Microsoft Windows Event ID and SNMP Traps
Reference Guide
For use with SmartStart version 8.25
Part number: 347870-009
Ninth edition: June 2009