- Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 1
HP Uninterruptible Power System R6000 Models User Guide December 2002 (Third Edition) Part Number 347223-003 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 1/9/03 9:32 AM - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 2
accompanying such products. Nothing herein should be construed as constituting an additional warranty. HP Uninterruptible Power System R6000 Models User Guide December 2002 (Third Edition) Part Number 347223-003 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 1/9/03 9:32 AM - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 3
...2-2 Front Panel LCD ...2-2 Front Panel LEDs ...2-3 Modes of Operation ...2-3 Charging the Batteries ...2-5 Placing the UPS in Operate Mode ...2-5 HP Uninterruptible Power System R6000 Models User Guide iii HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 1/9/03 9:32 - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 4
Batteries ...4-7 Care and Storage of Batteries...4-7 Pre-Failure Battery Warranty...4-8 Chapter 5 Troubleshooting Responding to Audible Alarms ...5-1 Trouble Indicators ...5-4 LED Alarm Configurations ...5-4 Repairing the UPS...5-5 iv HP Uninterruptible Power System R6000 Models User Guide HP - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 5
B-1 Appendix C Specifications Physical Specifications ...C-1 Input Specifications ...C-1 Output Specifications...C-2 Battery Specifications ...C-3 Battery Runtime...C-4 Environmental Specifications ...C-4 Index HP Uninterruptible Power System R6000 Models User Guide v HP CONFIDENTIAL Codename - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 6
for one individual to handle safely. Weight in kg WARNING: To prevent personal injury or damage to the equipment, observe Weight in lb local occupational health and safety requirements and guidelines for manual material handling. HP Uninterruptible Power System R6000 Models User Guide vii HP - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 7
Text set off in this manner presents clarifying information or specific instructions. NOTE: Text set off in this manner presents commentary and user input. • Sans serif typeface is used for uniform resource locators (URLs). viii HP Uninterruptible Power System R6000 Models User Guide HP - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 8
or software • Operating system type and revision level • Power management software type and version HP Website For information on this product as well as the latest drivers, firmware, and service packs, go to www.hp.com. HP Uninterruptible Power System R6000 Models User Guide ix HP CONFIDENTIAL - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 9
, call 1-800-263-5868. • Elsewhere, see the HP website for locations and telephone numbers. Reader's Comments To comment on this guide, send an email to [email protected]. x HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 10
computers. CAUTION: Use only the DE9 cables supplied by HP to connect the communications port to the host computer. Use of standard RS-232 cables may cause equipment damage. HP Uninterruptible Power System R6000 Models User Guide 1-1 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 11
R6000 Models UPS Model Part Number Comments R6000 347207-001 North American, high-voltage, rack-mounted UPS R6000j 347207-291 Japanese, high-voltage, rack-mounted UPS R6000i 347207-B31 International, high-voltage, rack-mounted HP Uninterruptible Power System R6000 Models User Guide HP - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 12
(left to right) 1, 2, 3, 4, and 5 7 Circuit breakers for (left to right) • Segments 1 and 4 • Segment 2 • Segments 3 and 5 8 REPO port HP Uninterruptible Power System R6000 Models User Guide 1-3 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 8:21 AM - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 13
segment 3 (two IEC-320-C14 receptacles and one IEC-320-C20 receptacle) 4 Load segment 4 (three IEC-320-C14 receptacles) 5 Load segment 5 (three IEC-320-C14 receptacles) 1-4 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 14
Power Management Software Power management software ensures maximum power reliability of computer systems through comprehensive control of UPSs. Specifically, power management software: IMPORTANT: Not all UPSs are equipped to support HP Uninterruptible Power System R6000 Models User Guide 1-5 HP - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 15
are chained, no additional boards can be used in the other units. For installation instructions, refer to the documentation shipped with the option card kits. 1-6 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12 - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 16
Power management software enables a single UPS with one Multi-Server UPS Card to protect up to four servers. If two Multi-Server UPS Cards are installed devices can be powered from a different UPS load segment. HP Uninterruptible Power System R6000 Models User Guide 1-7 HP CONFIDENTIAL Codename: - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 17
example, connecting three UPS R6000 units to one Scalable UPS Card creates a virtual 18 kVA UPS. The virtual UPS would have nine independently controlled load segments. Figure 1-5: Scalable UPS Card 1-8 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 18
SNMP-EN Adapter Kit includes OnliNet software and documentation, as well as information on installing and configuring the SNMP-EN Adapter using MIB and Power MIB. Figure 1-6: SNMP-EN Adapter HP Uninterruptible Power System R6000 Models User Guide 1-9 HP CONFIDENTIAL Codename: Arcuda Part Number - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 19
250 VA. To connect devices to the PDU, use IEC-320 jumper cords (Part No. 295633-B21). Two are provided with the PDU kit. 1-10 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 2/20/03 2:48 PM - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 20
transient), misuse, or abuse. Pre-Failure Battery Warranty Refer to the section, "Pre-Failure Battery Warranty," in Chapter 4 for specific information on the battery warranty. HP Uninterruptible Power System R6000 Models User Guide 1-11 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 21
options in the LCD menu structure 4 On Starts UPS powering the load 5 Standby Places UPS into Standby mode/Reset 6 Test/Alarm Reset Resets alarm or initiates self-test HP Uninterruptible Power System R6000 Models User Guide 2-1 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 22
of the UPS. Refer to the section, "Changing Configuration Parameters," in Chapter 3 for configuration instructions. Figure 2-2: Front panel LCD display 2-2 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/13/02 12 - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 23
mode (batteries charging) 2 Yellow Solid yellowOn Battery 3 Yellow Solid yellowOn Bypass 4 Red Flashing redOne or more Power is available at the UPS output receptacles. - The UPS monitors and charges batteries if required. HP Uninterruptible Power System R6000 Models User Guide 2-3 HP - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 24
the UPS shuts down when it is on battery power and the load is less than eight percent. - Power is automatically restored to the output receptacles when utility power is restored. 2-4 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 25
Allow the batteries to charge for at least 24 hours before supplying backup power to your devices. Placing the UPS in Operate Mode Press the On button (1) to transfer the system to Operate mode. Figure 2-5: On button HP Uninterruptible Power System R6000 Models User Guide 2-5 HP CONFIDENTIAL - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 26
, refer to the section, "Status," in Chapter 3. For causes and suggested actions for all alarm conditions, refer to Chapter 5, "Troubleshooting." 2-6 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/13/02 12:54 PM - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 27
condition that caused the alarm still exists. Refer to Chapter 5, "Troubleshooting," for information on what to do if the UPS detects an or circuit breaker at the utility panel. HP Uninterruptible Power System R6000 Models User Guide 2-7 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 28
functions on the unit, such as maintaining the battery and troubleshooting alarms. Changing Configuration Parameters Use the front panel deselects options in the LCD menu structure HP Uninterruptible Power System R6000 Models User Guide 3-1 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223 - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 29
supplies utility power to the output receptacles. • If the utility voltage is outside this range, the UPS supplies battery power to the ," in this chapter for more information. 3-2 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 30
a list of all menu options. The variable xxxxxx is one of the choices in the left column of the menu map. Submenu choices are shown to the right. Main Menu → xxxxxx HP Uninterruptible Power System R6000 Models User Guide 3-3 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 31
Set Sync Range ± Hertz Communications Setup Set Voltage Set Site Fault Set Sleep Mode Load Segments Battery Setup Serial Port 1 Serial Port 2 3-4 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/13/02 12:54 PM - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 32
to battery power. The UPS has been placed in Bypass mode. The power feeding the UPS-protected devices has terminated. Utility power has been restored to the devices backed up by the UPS. There are too many loads attached to the UPS. HP Uninterruptible Power System R6000 Models User Guide 3-5 HP - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 33
two squares past the line each represent 10% of overload (20% overload in all). In contrast, this display shows a 60% load. The battery voltage. 3-6 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/13/02 12:54 PM - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 34
than one alarm, Battery Low x Alarms Utility Not Present x Alarms Battery Totally Discharged Explanation Contact an authorized service provider. Contact an authorized service battery power, the battery needs to be replaced. continued HP Uninterruptible Power System R6000 Models User Guide 3-7 HP - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 35
This menu selection shows the control board firmware version. Control Board Version x. x x This menu selection shows the communication board firmware version. Communication Bd Version x. x x 3-8 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 36
2 3 - 5 ON Display Test Select Display Test from the Main Menu to test the LCD display. Press the Escape button to exit the test. DISPLAY TEST HP Uninterruptible Power System R6000 Models User Guide 3-9 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/13/02 12:54 PM - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 37
of each cabinet, or configures the number of external battery cabinets. Choose 5 A-H for the UPS batteries, and 5 A-H for each additional ERM, using the Center and Enter buttons. 3-10 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 38
The password must be six characters long. The default password is COMPAQ. Set Password COMPAQ To set the password: 1. Select the first digit using the password, contact an HP authorized service provider. HP Uninterruptible Power System R6000 Models User Guide 3-11 HP CONFIDENTIAL Codename: Arcuda - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 39
option. The current Parity value is displayed next to the asterisk (*). Select the desired value for parity: odd, even, none, mark, or space. 3-12 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/13/02 12:54 PM - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 40
is enabled, if the UPS is supplying battery power and the load on the UPS is less than eight percent, the UPS switches to Sleep mode and the UPS turns off . Set Sleep Mode * Enable HP Uninterruptible Power System R6000 Models User Guide 3-13 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223 - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 41
in use. Refer to the section, "Care and Storage of Batteries," in this chapter for information on keeping the batteries charged while the UPS is in extended storage. HP Uninterruptible Power System R6000 Models User Guide 4-1 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 42
service provider. WARNING: To reduce the risk of personal injury, do not attempt to replace batteries unless all battery circuit breakers (UPS and any connected ERMs) are in the off position. There is a 400 Vdc across the batteries. 4-2 HP Uninterruptible Power System R6000 Models User Guide HP - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 43
Placing the UPS in Manual Bypass mode 2. Using a Philips screwdriver, remove the lower front bezel by backing off the captive screws on each side. Figure 4-2: Removing screws from the lower front bezel HP Uninterruptible Power System R6000 Models User Guide 4-3 HP CONFIDENTIAL Codename: Arcuda - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 44
replacement. Figure 4-3: Placing the battery circuit breaker in the off position 4. Squeeze the release tabs on the sides of the battery cable connectors to disconnect the cables from the battery. Figure 4-4: Disconnecting the battery cables 4-4 HP Uninterruptible Power System R6000 Models User - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 45
that were removed from the unit. 7. Set aside the used battery packs for proper disposal. Refer to the section, "Disposing of Used Batteries," in this chapter. HP Uninterruptible Power System R6000 Models User Guide 4-5 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 46
within approximately four hours. Allow the batteries to charge for 24 hours before using the UPS to supply backup power to devices. The load may not be fully protected for 24 hours. 4-6 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223 - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 47
c. Allow the UPS to charge the batteries for 24 hours. d. Update the battery recharge date label. CAUTION: Because of the battery's short shelf life, avoid storing a battery spare as a backup. HP Uninterruptible Power System R6000 Models User Guide 4-7 HP CONFIDENTIAL Codename: Arcuda Part Number - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 48
the first year of ownership includes parts and labor. If battery spares are not available for a particular UPS model, then the entire UPS, including its battery, is replaced. 4-8 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 49
troubleshooting guide when problems occur with the UPS. Solutions for alarms are provided, as well as general solutions for UPS problems an authorized service provider. Reduce the load. Check the status of the batteries. continued HP Uninterruptible Power System R6000 Models User Guide 5-1 - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 50
's ambient temperature. If the alarm still sounds, contact an authorized service provider. Cycle the input power (turn the mains circuit breaker off, then on). If the condition remains, contact an authorized service provider. continued 5-2 HP Uninterruptible Power System R6000 Models User Guide - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 51
service provider. Contact an authorized service provider. Check battery connections and make sure the battery breaker is in the on position. Run the UPS for 24 hours. If the condition does not clear, contact an authorized service provider. HP Uninterruptible Power System R6000 Models User Guide - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 52
. The UPS is in Standby mode and on battery power. No utility power is available. Action, if necessary Press the On button to power the output receptacles of the UPS. No action is needed. The UPS will shut down in 30 seconds. continued 5-4 HP Uninterruptible Power System R6000 Models User Guide - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 53
input voltage problem, if possible. Otherwise, be prepared to lose battery power to the loads when battery power is exhausted. HP or an HP authorized service representative. Other than battery replacement, there are no user-serviceable parts. HP Uninterruptible Power System R6000 Models User Guide - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 54
instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense. HP Uninterruptible Power System R6000 Models User - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 55
installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may void the user's authority to operate the equipment. A-2 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 56
11) - Electromagnetic Immunity • EN61000-3-2 (IEC61000-3-2) - Power Line Harmonics • EN61000-3-3 (IEC61000-3-3) - Power Line Flicker • EN60950 (IEC950) - Product Safety HP Uninterruptible Power System R6000 Models User Guide A-3 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 57
Regulatory Compliance Notices Japanese Notice BSMI Notice A-4 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 1/16/03 3:41 PM - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 58
To forward them to recycling or proper disposal, please use the public collection system or return them to HP, your authorized HP partners, or their agents. HP Uninterruptible Power System R6000 Models User Guide A-5 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 59
. Use one or more of the following methods when handling or installing electrostatic-sensitive install the part. For more information on static electricity, or assistance with product installation, contact your authorized reseller. HP Uninterruptible Power System R6000 Models User Guide B-1 HP - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 60
, 208, 220, 230, 240 U.S. 17.25 in 10.50 in 24.3 in 300 lb Power Cord Supplied Hard-wired to AC mains Hard-wired to AC mains Hard-wired to AC mains HP Uninterruptible Power System R6000 Models User Guide C-1 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 8:23 AM - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 61
Specifications Output Specifications Table C-3: Output Specifications Receptacles UPS Model R6000 Nominal Power Rating (VA) 6000 R6000j 6000 R6000i 6000 Load Segment # C14 continued C-2 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 62
Type Voltage Charging Specification Sealed lead-acid, maintenance-free Internal batteries 12 VDC each, 360 VDC total 24 hours to full charge 4 hours to 90% capacity at default nominal utility voltage and no load HP Uninterruptible Power System R6000 Models User Guide C-3 HP CONFIDENTIAL Codename - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 63
Relative humidity Operating altitude Audible noise Specification 10oC - 40o C (50 oF -104oF) 20 - 80%; non-condensing Up to 3000 m (10,000 ft) above sea level Less than 55 dBA @ 1 meter C-4 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 64
fault alarm 3-13 Sleep mode 3-13 stop bits 3-12 sync range 3-12 UPS 3-1 voltage 3-2, 3-13 controls, front panel 2-1 counting active alarms 3-5 HP Uninterruptible Power System R6000 Models User Guide Index-1 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 8:26 AM - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 65
2-2 testing 3-9 LCD menus Active Alarms 3-7 Battery Data 3-8 Display Test 3-9 Firmware Version 3-8 Load Control 3-9 Main 3-3 map 3-4 Meters 3-6 Status 3-5 System Setup 3-10 Index-2 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 66
up 3-12 Power Distribution Unit See PDU power management software 1-5 Power MIB 1-9 power, viewing 3-6 power-up display 3-3 Pre-Failure Battery Warranty 4-8 preventing electrostatic discarge B-1 Index HP Uninterruptible Power System R6000 Models User Guide Index-3 HP CONFIDENTIAL Codename - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 67
overview 1-9 part number 1-5 software 1-5 specifications battery C-3 environmental C-4 input battery maintenance 4-1 configuring 3-1 installing 2-1 models 1-2 operation 2-1 overview 1-1 repairing 5-5 specifications C-1 troubleshooting 5-1 HP Uninterruptible Power System R6000 Models User Guide HP - Compaq R6000 | HP Uninterruptible Power System R6000 Models User Guide - Page 68
, firmware 3-8 viewing active alarms 3-7 battery data 3-8 firmware versions 3-8 receptacle status 3-5 voltage, frequency, and power 3-6 Battery Warranty 4-8 wave shape C-3 website, HP ix weight C-1 width C-1 www.hp.com ix Index HP Uninterruptible Power System R6000 Models User Guide Index-5 HP
HP CONFIDENTIAL
Codename: Arcuda Part Number: 347223-003 Last Saved On: 1/9/03 9:32 AM
HP Uninterruptible Power System
R6000 Models
User Guide
December 2002 (Third Edition)
Part Number 347223-003