D-Link DCS-6620 Product Manual - Page 131

External I/O Port Definition for the PTZ Internet Camera

Page 131 highlights

DCS-6620 User's Manual External I/O Port External I/O Port External I/O Port Definition for the PTZ Internet Camera The DCS-6620 provides a general I/O terminal block with one digital input and one relay switch for device control. Pin 1 and pin 2 can be connected to an external sensor and the state of voltage will be monitored from the initial state 'LOW'. The relay switch of pin 3 and pin 4 can be used to turn on or off the external device. The I/O connector provides the physical interface for digital output (DO) and digital input (DI) that is used for connecting a diversity of external alarm devices to the PTZ Internet Camera such as IR-Sensors and alarm relays. The digital input is used for connecting external alarm devices and once triggered images will be taken and e-mailed. External I/O Port I/O Terminal Block: 1 DI+ 2 DI3 SW_COMMON 4 SW_NOPEN INPUT (Max. 50mA, 12VDC) INPUT (Initial state of DI is low) OUTPUT (open from SW_OPEN at initial state) (close with SW_OPEN when set DO to ON) OUTPUT (Max. 1A, 24VDC or 0.5A, 125VAC) D-Link Systems, Inc. 131

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143

131
DCS-6620 User’s Manual
D-Link Systems, Inc.
External I/O Port
External I/O Port
1
DI+
INPUT (Max. 50mA, 12VDC)
2
DI-
INPUT (Initial state of DI is low)
3
SW_COMMON
OUTPUT (open from SW_OPEN at initial state)
(close with SW_OPEN when set DO to ON)
4
SW_NOPEN
OUTPUT (Max. 1A, 24VDC or 0.5A, 125VAC)
The digital input is used for connecting external alarm devices and once triggered images will
be taken and e-mailed.
I/O Terminal Block:
External I/O Port
External I/O Port Definition for the PTZ Internet Camera
The
DCS-6620
provides a general I/O terminal block with one digital input and one relay switch
for device control. Pin 1 and pin 2 can be connected to an external sensor and the state of
voltage will be monitored from the initial state ‘LOW’. The relay switch of pin 3 and pin 4 can
be used to turn on or off the external device.
The I/O connector provides the physical interface for digital output (DO) and digital input (DI)
that is used for connecting a diversity of external alarm devices to the PTZ Internet Camera
such as IR-Sensors and alarm relays.