    DES-5016 Fast Ethernet Switching System User's Guide Rev. 02 (October, 2004) 651DES32.K15
  • D-Link DES-5016 | Product Manual - Page 2
    materials, under normal use and service, for the following periods measured from date of purchase from D-Link or its authorized Reseller: Product returned to a D-Link office within ninety (90) days of purchase. A list of DLink offices is provided at the back of this manual, together with a copy
  • D-Link DES-5016 | Product Manual - Page 3
    the back of this manual, must be sent to a D-Link office. To obtain an RMA number for warranty service as to a hardware product, or to obtain warranty service as to a software product, contact the D-Link office nearest to you. D-Link Offices to Contact for Warranty Service: To mail your Registration
  • D-Link DES-5016 | Product Manual - Page 4
    such as translation, transformation, or adaptation without permission from D-Link Corporation/D-Link Systems Inc., as stipulated by the United States Copyright Act if not installed and used in accordance with this user's guide, may cause harmful interference to radio communications. Operation of
  • D-Link DES-5016 | Product Manual - Page 5
    Aerosolreiniger. Am besten dient ein angefeuchtetes Tuch zur Reinigung. Um eine Beschädigung des Gerätes zu vermeiden sollten Sie nur Zubehörteile verwenden, die vom Hersteller Wenden Sie sich mit allen Fragen die Service und Repartur betreffen an Ihren Servicepartner. Somit stellen
  • D-Link DES-5016 | Product Manual - Page 6
    Table of Contents Table of Contents...vi About This Guide...1 Audience...1 Organization...1 1...2 Introduction...2 Features...2 Front Panel...4 Rear 7 RMON ...7 Updating Firmware ...7 2...8 Installing the DES-5016 8 Unpacking the DES-5016 8 Installation Options ...9 Installing Optional Modules 14
  • D-Link DES-5016 | Product Manual - Page 7
    CPU Module ...24 8-Port TX Module ...26 8-Port FX Module ...28 2-Port 100BASE-FX Module 29 1-Port 1000BASE-SX Module 31 5...32 Managing the DES-5016 32 Local Console Management 33 Telnet...34 Log In ...35 Help Message...36 Panel Conventions...37 Console Program...38 System Configuration 38 User
  • D-Link DES-5016 | Product Manual - Page 8
    Menu 69 Create New VLAN 70 Delete VLAN Menu 72 Trunking Port Management Menu 74 Create New Trunking Port 75 Delete Trunking Port 77 6...79 Troubleshooting ...79 Appendix A...82 DES-5016 Technical Specifications 82 Switch Specifications 82 Port Specifications 82 Index...87 viii
  • D-Link DES-5016 | Product Manual - Page 9
    the contents of each chapter. It describes the features of the D-Link DES-5016 Fast Ethernet Switching System. Information about the DES-5016 and other D-Link products is available on our web site at www.dlink.com. Audience This user guide is intended for the networking or computer technician who is
  • D-Link DES-5016 | Product Manual - Page 10
    or for use with other switches and hubs on a larger network. There are three models available: the DES-5016TX, DES-5016TF and the DES-5016FX. This manual refers to all models as the DES-5016. There are two optional modules available: a 2-Port 100BASE-FX and a 1-Port 1000BASE-SX modules. Both modules
  • D-Link DES-5016 | Product Manual - Page 11
    Switching System User's Guide • Supports Full and Half Duplex for both 10 Mbps and 100 Mbps. • Eight thousand active MAC address table entries per device with self-learning and table aging. • The DES-5016 supports SNMP for RFC 1213, RFC 1757, and RFC 1493. • VLAN support for eight broadcast domains
  • D-Link DES-5016 | Product Manual - Page 12
    Fast Ethernet Switching System User's Guide Front Panel The DES-5016 is designed for management at a glance. The front of the DES-5016 has LEDs that give you essential information at a glance. The DES-5016 is a modular unit. The chassis has five slots. All the modules have LEDs. See Chapter 4,
  • D-Link DES-5016 | Product Manual - Page 13
    's Guide DES-5016TF The DES-5016TF, displayed in Figure 2, comes with eight 10/100-TX ports and eight 100BASE-FX ports. The DES-5016TF is shown with the optional 1-Port 1000BASE-SX module installed. Slot 1 CPU Module RS-232 Port Slot 2 1x BASE-FX Switched ports module 2x 3x 4x Link/Act
  • D-Link DES-5016 | Product Manual - Page 14
    System User's Guide Rear Panel The three pronged power plug, ventilation fan and the on/off switch are located at the rear of the DES-5016 displayed in requirements are indicated on the rear panel of the DES5016. When installing the DES-5016, leave enough room to allow you to plug in the power
  • D-Link DES-5016 | Product Manual - Page 15
    to log in and change the configuration. D-View/ SNMP Management The DES-5016 supports SNMP through D-View, D-Link's proprietary SNMP application and through other vendors' SNMP applications. Please refer to the appropriate documentation for instructions on installing and using D-View and other SNMP
  • D-Link DES-5016 | Product Manual - Page 16
    DCE serial cable • Two mounting brackets and eight screws • Four rubber pads with adhesive backing • One six foot (1.82 m) power cord • DES-5016 User's Guide CD ROM, DES-32/50 V.01 5.25/625M, part # 651DES32.K15 • Registration card If any items are missing, contact the retailer where you purchased
  • D-Link DES-5016 | Product Manual - Page 17
    Fast Ethernet Switching System User's Guide Installation Options There are two options for installing the DES-5016: desktop/ shelf installation or rack installation. Follow these guidelines for desktop/ shelf installation or rack installation: • The surface must support 18 lbs or 8 kg. • The power
  • D-Link DES-5016 | Product Manual - Page 18
    Switching System User's Guide Desktop/ Shelf Installation The dimensions of the DES-5016 are 4.72 inches (120 mm) x 10.39 inches (264 mm) x 17.32 inches (440 mm). These measurements include the 8-mm rubber feet provided with the DES-5016. Follow these steps to install the DES-5016 on a desktop
  • D-Link DES-5016 | Product Manual - Page 19
    Fast Ethernet Switching System User's Guide Figure 6: Attach Feet Installing the DES-5016 11
  • D-Link DES-5016 | Product Manual - Page 20
    Fast Ethernet Switching System User's Guide Rack Installation The DES-5016 can be mounted in an EIA standard size, 19-inch rack. The dimensions of the DES-5016 are 4.4 inches (112 mm) x 10.39 inches (264 mm) x 17.32 inches (440 mm). The DES-5016 can be placed in a wiring closet along with other
  • D-Link DES-5016 | Product Manual - Page 21
    Fast Ethernet Switching System User's Guide Figure 8: Insert into Rack Installing the DES-5016 13
  • D-Link DES-5016 | Product Manual - Page 22
    into the guides, see DES-5016 will auto detect the new module. 6. Remove the dust cover from the transceiver and plug the cable in, if you are installing a fiber optic or gigabit module. 7. Check the LEDs to verify that there is a link and a proper connection at the port. See the Troubleshooting
  • D-Link DES-5016 | Product Manual - Page 23
    Fast Ethernet Switching System User's Guide Figure 9: Remove Blank Bracket Installing the DES-5016 15
  • D-Link DES-5016 | Product Manual - Page 24
    Fast Ethernet Switching System User's Guide Figure 10: Insert Optional Module Installing the DES-5016 16
  • D-Link DES-5016 | Product Manual - Page 25
    all ports will auto negotiate the proper speed and duplex mode when the DES-5016 is powered on. Reboot the DES-5016 if there is a problem. Contact D-Link Systems, Inc. for technical support. Check the configuration of the DES-5016 after a power failure but do not reset unless it is necessary. The
  • D-Link DES-5016 | Product Manual - Page 26
    Guide 3 Connecting the DES-5016 to the Network This chapter covers the following: • Cable Specifications • Ports • Connecting the DES-5016 to another DES-5016 • Connecting the DES . Telephone cable does not support Ethernet or Fast Ethernet. connector. The most common problem on Ethernet or Fast
  • D-Link DES-5016 | Product Manual - Page 27
    Switching System User's Guide Table 1: Cable Specifications for Copper Connection Ethernet Type 10BASE-T 100-TX Cable Requirements Category 3, 4, or 5 UTP or STP Category 5 UTP or STP Maximum Length 328 ft (100 M) 328 ft (100 M) Figure 11: Cable Diagram Connecting the DES-5016 to the Network
  • D-Link DES-5016 | Product Manual - Page 28
    Fast Ethernet Switching System User's Guide Fiber Optic Cable Data can travel much farther over fiber optic cable than over Category 3, 4 or 5 cable. Cable length the specified cable: • 62.5 um cable 720 feet (220 meters) • 50 um cables 1639 (500 meters) Connecting the DES-5016 to the Network 20
  • D-Link DES-5016 | Product Manual - Page 29
    Guide supports full duplex at 1000 Mbps. Contact sales at D-Link, Inc. to purchase either of the optional modules. Refer to Installing Optional Modules, for installation instructions duplex mode. RS-232 Port Follow these steps to connect the DES-5016 and another device: 1. Plug one end of the cable
  • D-Link DES-5016 | Product Manual - Page 30
    configured on the device if more than one port is connected between a DES-5024, DES3216 and DES-3224. Port trunking increases the efficiency of the DES-5016 by increasing the bandwidth. See the section on Port Trunking in Chapter 5 for instructions on how to configure trunked ports. Connecting the
  • D-Link DES-5016 | Product Manual - Page 31
    Switching System User's Guide 4 LEDs The LED panel of the DES-5016, is designed to allow you to manage the DES-5016 at a glance 4 Link/Act Full/Half 1x 2x 3x 4x Link/Act Full/Half 5x 5x 6x 7x 8x 6x 7x 8x Link Duplex Collision Figure 12: DES-5016TF LEDs Transmitting Link/Act
  • D-Link DES-5016 | Product Manual - Page 32
    during normal operation. Diagnostic The Diagnostic LED is used to diagnose any problem on the DES-5016. If any part of the DES-5016 fails the POST or if a problem occurs the Diagnostic LED displays a code indicating the problem. See Chapter 6 for the meaning of the LED code and a recommended action
  • D-Link DES-5016 | Product Manual - Page 33
    Guide Table 3: CPU Module LEDs LED Lit or Flashing Status Diagnostic Utilization Status LED increments when firmware is being loaded to the DES- Normal if there are no problems. See Chapter 6 for a chart showing the meaning of the Diagnostic LED. Check Diagnostic if DES-5016 is on and all
  • D-Link DES-5016 | Product Manual - Page 34
    -TX ports auto-negotiate the speed by default. The ports can be manually set for a particular speed. Green indicates the port is running at 100 Mbps. The 100BASE-FX ports do not support 10 Mbps. The 1000BASE-SX port only supports 1000 Mbps. Full/ Half The Full/ Half LED indicates the duplex mode
  • D-Link DES-5016 | Product Manual - Page 35
    Fast Ethernet Switching System User's Guide Table 4: 8-Port TX Module LEDs LED Link Act (Activity) 100/10 Full/ Half receiving data at full duplex Lit when the port is at full duplex Dark No link or link is down Port is not transmitting or receiving Dark when port is transmitting or receiving
  • D-Link DES-5016 | Product Manual - Page 36
    of the LEDs. BASE-FX Switched ports module 1 2 3 4 Link/Act Full/Half Link/Act Full/Half Link/ Act Figure 15: 8-Port FX Module Full/ Half Link/ Act The Link/ Act LED indicates two things: link and activity. Link refers to the link between the DES-5016 and another device. The LED lights when
  • D-Link DES-5016 | Product Manual - Page 37
    Switching System User's Guide 2-Port 100BASE-FX Module Link Transmitting Recieving Duplex Mode link at the port. Dx Dx means duplex mode. The Dx LED indicates the port's duplex mode. The ports will not auto negotiate the duplex mode. The default value is half duplex. They can be manually
  • D-Link DES-5016 | Product Manual - Page 38
    Fast Ethernet Switching System User's Guide Table 6: FX Module LED LED Lit Lk (Link) (Green) Dx (Duplex mode) (Green) Tx (Transmitting) (Green) Rx (Receiving) (Green) Col (collisions) (Amber) Port is linked to another device Port is in full duplex Port is transmitting data Data is being
  • D-Link DES-5016 | Product Manual - Page 39
    System User's Guide 1-Port 1000BASE-SX Module Act Link 1000BASE-SX Switched ports module Figure 17: 1-Port 1000BASE-SX Module The gigabit expansion module, displayed in Figure 17, is has one port. Refer to Table 7: Gigabit Module LED for an explanation the LEDs. Link The link LED lights to
  • D-Link DES-5016 | Product Manual - Page 40
    manage the DES-5016. D-View is a proprietary SNMP management program. D-View is provided with the DES5016. The DES-5016 supports other SNMP using other vendors' SNMP applications. All instructions given in this chapter assume that you are logged into the DES-5016 and are at the appropriate panel for
  • D-Link DES-5016 | Product Manual - Page 41
    Ethernet Switching System User's Guide Local Console Management Local Console Management is always done through the RS-232 serial port and requires a direct connection between the DES-5016 and a PC. This type of management is very useful when the network is down and the DES-5016 cannot be reached
  • D-Link DES-5016 | Product Manual - Page 42
    System User's Guide Telnet You can manage the DES-5016 via Telnet session. However, first you must assign a unique IP address to the DES-5016. Use Local assign an IP address. Once you have assigned an IP address to the DES-5016, you can use the management method of your choice. Telnet management
  • D-Link DES-5016 | Product Manual - Page 43
    Guide Log In The Log In panel, displayed in Figure 18, is the first panel you see when connecting to the DES-5016. All management methods require you to log into the DES Password. Figure 18: Login Follow these steps to log into the DES-5016 for the first time: Enter the default User Name and
  • D-Link DES-5016 | Product Manual - Page 44
    Fast Ethernet Switching System User's Guide Help Message A one page panel, displayed in Figure 19, is available. The menu lists the keystroke and typographic conventions available on the DES-5016. Figure 19: Help Message Managing the DES-5016 36
  • D-Link DES-5016 | Product Manual - Page 45
    Fast Ethernet Switching System User's Guide Panel Conventions Keystroke Conventions Example Description UP, DOWN, or TAB keys Select different items. SPACEBAR Toggle-switch. . After you are finished viewing the help panel, press Enter to return to the main menu. Managing the DES-5016 37
  • D-Link DES-5016 | Product Manual - Page 46
    Fast Ethernet Switching System User's Guide Console Program The Console Program, shown in Figure 20, is the main menu of the DES-5016. Figure 20: Console Program System Configuration The System Configuration menu gives you general information about the DES-5016 and allows you to assign a LAN IP
  • D-Link DES-5016 | Product Manual - Page 47
    Fast Ethernet Switching System User's Guide Spanning Tree Configuration The Spanning Tree Configuration menu allows you to enable or disable Spanning Tree Algorithm, set the Bridge menu: 1. Use the tab key or the up and down arrow keys to select an option. 2. Press Enter. Managing the DES-5016 39
  • D-Link DES-5016 | Product Manual - Page 48
    Fast Ethernet Switching System User's Guide System Configuration Menu The System Configuration menu, displayed in Figure 21, allows you to change the configuration of the DES-5016. Figure 21: System Configuration menu System Information The System Information menu displays the Hardware revision,
  • D-Link DES-5016 | Product Manual - Page 49
    Fast Ethernet Switching System User's Guide Software Update The Software Update menu is used to update the software on the DES-5016. This feature is only supported through Local Console Management. Follow these steps to select a menu: 1. Highlight the menu option. 2. Press Enter. System Information
  • D-Link DES-5016 | Product Manual - Page 50
    Guide MAC Address Specifies the hardwired address of the DES-5016. This address cannot be changed. System Description Brief manufacturer description of the DES-5016. This value cannot be changed. System Name Specifies the full name of the DES the physical location of the DES-5016, such as a building
  • D-Link DES-5016 | Product Manual - Page 51
    Fast Ethernet Switching System User's Guide System Reset The System Reset panel, displayed in Figure 23, enables you to reset the DES-5016 without powering off. Figure 23: System Reset Some configurations will require you to reset the DES-5016 in order for them to take effect. Screen prompts will
  • D-Link DES-5016 | Product Manual - Page 52
    Fast Ethernet Switching System User's Guide Factory Reset The Factory Reset panel, displayed in Figure 24, is used to reset the DES-5016 and restore all factory default values. Using this panel erases all configurations and customization. Figure 24: Factory Reset Follow these steps to restore
  • D-Link DES-5016 | Product Manual - Page 53
    Fast Ethernet Switching System User's Guide Figure 25: Factory Reset Confirmation Follow these steps to exit the panel without restoring factory default parameters: 1. Select No or Exit. 2. Press Enter. Managing the DES-5016 45
  • D-Link DES-5016 | Product Manual - Page 54
    Guide System Rate Control The System Rate Control panel, displayed in Figure 26, allows you to set the packet forwarding rate on the DES-5016. There are two options: Store & Forward and CutThrough. Figure 26: System Rate Control The DES means that when the DES-5016 receives an incoming packet
  • D-Link DES-5016 | Product Manual - Page 55
    Fast Ethernet Switching System User's Guide example, 1500 byte packets are delayed by 1200 microseconds in a Store and Forward device versus 60 microseconds in a Cut-Through device. Store and Forward requires more memory because the DES-5016 must store the packet before sending it out. Advantages of
  • D-Link DES-5016 | Product Manual - Page 56
    Switching System User's Guide Software Update Menu The Software Update menu, displayed in Figure 27, is used to upgrade the software on the DES-5016. Figure 27: . Never attempt to load software from the floppy drive. 2. Connect the DES-5016 and the PC with the software on it with the RS-232 cable
  • D-Link DES-5016 | Product Manual - Page 57
    Fast Ethernet Switching System User's Guide Figure 28: Transfer Firmware Figure 29: Send File Managing the DES-5016 49
  • D-Link DES-5016 | Product Manual - Page 58
    Fast Ethernet Switching System User's Guide Figure 30: Xmodem When the transfer is complete you will see the panel in Figure 31. The DES-5016 will reset itself automatically and you will have to log in again. Figure 31: EEPROM Managing the DES-5016 50
  • D-Link DES-5016 | Product Manual - Page 59
    Fast Ethernet Switching System User's Guide User Account Management The User Account Management panels allow you to add users, delete users and modify user Figure 32: User Account Change Follow these steps to select a menu option: 1. Select an option. 2. Press Enter. Managing the DES-5016 51
  • D-Link DES-5016 | Product Manual - Page 60
    Fast Ethernet Switching System User's Guide Create New User The Create New User panel, displayed in Figure 33, allows you to add new users. You can have a total of three users on the DES-5016. Figure 33: Create New User User Name Enter the user's name in this field. User names are case
  • D-Link DES-5016 | Product Manual - Page 61
    Ethernet Switching System User's Guide Follow these steps to add users: 1. Enter the User Name. 2. Enter the Password. 3. Reenter the password in the Confirm Password field. 4. Toggle the space bar to set the access level of the new user. 5. Select Save and press Enter. Managing the DES-5016 53
  • D-Link DES-5016 | Product Manual - Page 62
    Guide Delete Users The Delete Users panel, displayed in Figure 34, allows you to delete users from the DES5016. As a safety precaution, the DES-5016 . Figure 34: Delete Users User Name Identifies the users listed on the DES-5016. Access Level Determines whether the user is a Super User with full
  • D-Link DES-5016 | Product Manual - Page 63
    Fast Ethernet Switching System User's Guide 2. Toggle the space bar to change the current Access Level. 3. Select Save and press Enter. Follow these steps to change user the space bar to toggle the option from No to Yes. 3. Press Enter. 4. Select Save and press Enter. Managing the DES-5016 55
  • D-Link DES-5016 | Product Manual - Page 64
    Fast Ethernet Switching System User's Guide Change Password The Change Password panel, displayed in Figure 35, enables you to change user passwords. Figure 35: Enter the new password in the New Password field. 4. Reenter the new password in the Confirm Password field. Managing the DES-5016 56
  • D-Link DES-5016 | Product Manual - Page 65
    Fast Ethernet Switching System User's Guide 5. Select Save and press Enter to save your changes. Managing the DES-5016 57
  • D-Link DES-5016 | Product Manual - Page 66
    Fast Ethernet Switching System User's Guide Switch Port Configuration The Switch Port Configuration panels are used to configure individual ports on the DES5016. The only with. 2. Select the group on the Console Program panel. 3. Press Enter to go to the appropriate panel. Managing the DES-5016 58
  • D-Link DES-5016 | Product Manual - Page 67
    Fast Ethernet Switching System User's Guide Switch Port Configuration Menu The Switch to use a disabled port. Physical Refers to the physical state of the port. If you manually change the state of a port it will remain in that state until you change it. It Mbps half duplex. Managing the DES-5016 59
  • D-Link DES-5016 | Product Manual - Page 68
    Guide Ports can only be in 1000SX/Full. Half-duplex operation is not supported. Port State All ports have four states: blocking, listening, learning learning the MAC address for data packets. This setting cannot be manually changed. Priority The port priority can be set from zero to 255 DES-5016 60
  • D-Link DES-5016 | Product Manual - Page 69
    Guide Spanning Tree Configuration The Spanning Tree Configuration panel is used to configure the Spanning Tree Algorithm. The Spanning Tree Algorithm (STA) in the DES your network. These backup paths are idle until the DES-5016 determines that a problem has developed in the primary path. If the
  • D-Link DES-5016 | Product Manual - Page 70
    Guide Spanning Tree Algorithm Spanning Tree Algorithm can be enabled or disabled. Use Spanning Tree to prevent network loops. Bridge Priority The Bridge Priority can be from 0 to 65535. Zero is the highest Bridge Priority. The higher the Bridge Priority the greater the chance that the DES manually,
  • D-Link DES-5016 | Product Manual - Page 71
    Max Age Time Avoid low number for unnecessary reset of Root Bridge Max Age < 2 x (Forward Delay 1) Max Age > 2 x Hello Time + 1) Disable a port for security or problem isolation Managing the DES-5016 63
  • D-Link DES-5016 | Product Manual - Page 72
    Guide SNMP Management Configuration The SNMP Management Configuration panel is used to configure the DES-5016 for SNMP management. Leave the default values in place if you are not managing your network through SNMP. The DES based network manager. The DES-5016 supports its own proprietary enterprise
  • D-Link DES-5016 | Product Manual - Page 73
    Fast Ethernet Switching System User's Guide SNMP Management Configuration Menu The SNMP Management Configuration menu, displayed in Figure 38, enables you to configure the DES-5016 for SNMP management. Figure 38: SNMP Management Configuration menu SNMP Manager Setting The fields under this setting
  • D-Link DES-5016 | Product Manual - Page 74
    Failure Signifies that an addressee (or manager/ user) on the DES-5016 is not a valid user of the DES-5016 and may have entered an incorrect community name. Link Change Event Signifies that the link of a port has changed from link up to link down or vice versa. IP Address This field is used to
  • D-Link DES-5016 | Product Manual - Page 75
    Fast Ethernet Switching System User's Guide 2. Select the Access Right field and toggle the space bar to select Read Only or Read/ Write. 3. Select the Status String. 3. Select Status and toggle the space bar to select Valid or Invalid. 4. Select Save and press Enter. Managing the DES-5016 67
  • D-Link DES-5016 | Product Manual - Page 76
    Fast Ethernet Switching System User's Guide VLAN Port Management A Virtual Local Area Network (VLAN) is a are not already on their own LAN segment. VLANs can be used to subdivide the network. The DES-5016 supports port based VLAN. Port based VLAN means that the VLAN is grouped by port. If a VLAN
  • D-Link DES-5016 | Product Manual - Page 77
    Fast Ethernet Switching System User's Guide VLAN Port Management Menu The VLAN Port Management menu, displayed in Figure 39, enables you to create, delete and modify VLANs on the DES-5016. Figure 39: VLAN Port Management menu Follow these steps to create, delete and modify VLAN: 1. Select the
  • D-Link DES-5016 | Product Manual - Page 78
    Fast Ethernet Switching System User's Guide Create New VLAN The Create New VLAN menu, displayed in unique name. Port # Is the number of the port. The numbers on the panel match the ports on the DES-5016. Some ports are combined. For example, ports 5 and 9 are shown as "Port 5/9". Ports that are
  • D-Link DES-5016 | Product Manual - Page 79
    Fast Ethernet Switching System User's Guide VLAN. All ports will have a status of available on this panel, even after they have been selected as part of a VLAN. VLAN and toggle the space bar to change the status from Available to Selected. 3. Select Save and press Enter. Managing the DES-5016 71
  • D-Link DES-5016 | Product Manual - Page 80
    Fast Ethernet Switching System User's Guide Delete VLAN Menu The Delete VLAN menu, displayed in Figure 41, is used to delete VLANs. the VLAN. 3. Select Save and press Enter. 4. A screen prompt will warn you that you must reset the DES-5016 in order for the change to take effect. Managing the
  • D-Link DES-5016 | Product Manual - Page 81
    Fast Ethernet Switching System User's Guide Modify VLAN Menu The Modify VLAN menu, displayed in Figure 42, enables you to modify VLANs. Figure 42: Modify VLAN menu means the port has been selected as part of a VLAN. 5. Select Save and press Enter to implement your changes. Managing the DES-5016 73
  • D-Link DES-5016 | Product Manual - Page 82
    Fast Ethernet Switching System User's Guide Trunking Port Management Menu The Trunking Port Management panels, displayed in Figure 43, are used to create, delete Follow these steps to create, delete and modify trunk ports: 1. Select the appropriate option. 2. Press Enter. Managing the DES-5016 74
  • D-Link DES-5016 | Product Manual - Page 83
    Fast Ethernet Switching System User's Guide Create New Trunking Port The Create New Trunking Port a name. Port # Is the number of the port. The numbers on the panel match the ports on the DES-5016. Some ports are not available for trunking. For example, port 5 has a status of N/A. Ports that are
  • D-Link DES-5016 | Product Manual - Page 84
    Fast Ethernet Switching System User's Guide a TrunkGroup. All ports will have a status of available on this panel, even after they have been selected as part of a and toggle the space bar to change the status from Available to Selected. 3. Select Save and press Enter. Managing the DES-5016 76
  • D-Link DES-5016 | Product Manual - Page 85
    Fast Ethernet Switching System User's Guide Delete Trunking Port The Delete Trunking Port panel, displayed in Figure 45, is used to delete Trunk Ports. Figure Modify Trunking Port The Modify Trunking Port panel, displayed in Figure 46, enables you to Modify Trunking Ports. Managing the DES-5016 77
  • D-Link DES-5016 | Product Manual - Page 86
    Fast Ethernet Switching System User's Guide Figure 46: Modify Trunking Port Trunking Port Name The names of all Trunked Ports appear in this column. Follow are not available for inclusion in any trunking group. 5. Select Save and press Enter to implement your changes. Managing the DES-5016 78
  • D-Link DES-5016 | Product Manual - Page 87
    This troubleshooting section is intended to help you solve the most common problems on the DES-5016. The Diagnostic LED displays a code if there is a problem on the DES-5016. If an error cannot be resolved by implementing the solutions in this section, contact D-Link Technical Support. All
  • D-Link DES-5016 | Product Manual - Page 88
    it on again. Use the monitor to check the error messages. Return the DES-5016 to DLink for service if the problem persists. Forget Password If you forget your password, contact D-Link Technical Support at (949) 788-0805 for assistance or check our web site at www.dlink.com. Troubleshooting 80
  • D-Link DES-5016 | Product Manual - Page 89
    Fast Ethernet Switching System User's Guide Table 9: Diagnostic LED 2 PHY Failure ARL Failure ARL Memory Failure Troubleshooting 81
  • D-Link DES-5016 | Product Manual - Page 90
    Fast Ethernet Switching System User's Guide Appendix A DES-5016 Technical Specifications Switch Specifications • Complies and Store-and-Forward switching for reliable error-free packet transfers • Native SNMP management support with Ethernet MIB II (RFC 1213) and bridge MIB (RFC 1493), RMON MIB
  • D-Link DES-5016 | Product Manual - Page 91
    Fast Ethernet Switching System User's Guide • Full or Half Duplex for all 10/100-TX ports • 100BASE-FX ports operate at full or half duplex requires 1300 nm mulitmode fiber optic
  • D-Link DES-5016 | Product Manual - Page 92
    Fast Ethernet Switching System User's Guide Standards: Protocol: Data Transfer Rate: Topology: Network Cables: Number of Ports: (depending on modules used) General IEEE 802.3 10BASE-T Ethernet IEEE 802.3u 100-TX,
  • D-Link DES-5016 | Product Manual - Page 93
    Fast Ethernet Switching System User's Guide AC inputs: Power Consumption: DC fans: Operating Temperature: Storage Temperature: Humidity: Dimensions: Weight: EMI: Safety: Physical and Environmental 100 - 240 VAC, 50/60 Hz (internal
  • D-Link DES-5016 | Product Manual - Page 94
    Fast Ethernet Switching System User's Guide Transmission Method: RAM Buffer: Filtering Address Table: Packet Filtering/ Forwarding Rate: MAC Address Learning: Performance Cut-Through and Store-and-Forward 1 M bytes per device 8 K entries
  • D-Link DES-5016 | Product Manual - Page 95
    72, 77 Delete Trunking Port 77 Delete Users 54 Delete VLAN 72 DES-5016 to DES-5016 connection 22 diagnostic 24 Diagnostic LED table 79, 81 Duplex Default Gateway 42 LAN IP Address 42 LAN Subnet Mask 42 Link 26, 31 Link Change 66 Link/ Act 28 Lk 29 Local Console Management 7, 33 Log In
  • D-Link DES-5016 | Product Manual - Page 96
    Fast Ethernet Switching System User's Guide Port 70 Port 75 Port State 60 Port States 79 Ports 21 POST Errors 79 Power 17 Power LED 24, 79 Priority 60 R Rear Panel 6
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

DES-5016 Fast Ethernet Switching
System
User’s Guide
Rev. 02 (October, 2004)
651DES32.K15