Dacor DHI542 Planning Guides

Dacor DHI542 Manual

Dacor DHI542 manual content summary:

  • Dacor DHI542 | Planning Guides - Page 1
    pressure General Specifications Model DHI361 DHI421 DHI482 DHI542 DHI602 Blowers 1 1 2 range or cooktop in use. Check the manufacturers specifications for the cooktop or range. www.Dacor.com Phone: (800) 793-0093 Specifications are subject to change without notice. See installation instructions
  • 1

PLANNING
GUIDE
www.Dacor.com
Phone: (800) 793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
7.2
36” (91.4 cm) - 42” (106.7 cm)
48” (121.9 cm) - 54” 137.2 cm)
60” (152.4 cm)
30”
(76.2 cm)
15 ¾” (40.0 cm)
Chimney
12 9/16” (31.9 cm)
12 ½”
(31.8 cm)
15 ½”
(39.4 cm)*
28” (71.1 cm) to 36” (91.4 cm)
DHI SERIES OVERALL DIMENSIONS
Blower
600 CFM* (1200 CFM* for units with 2 blowers)
with electronic speed control
Blower Speeds
4
Lights
12 Vac, 20 Watt halogen
Filters
Baffle type, dishwasher safe
Exhaust
8 Inch
Finish
430 stainless steel
Total connected
load
120 Vac, 60 Hz (see table at right for current
rating)
Circuit
requirements
120 Vac, 15 Amp. grounded, dedicated 3-wire
circuit (hot, neutral, ground)
* At zero inches static pressure
36”, 42”, 48”, 54” and 60” Wide
Ceiling Mount Island Hoods
DHI Hoods
Model
Blowers
Lights
Filters
Maximum
Current Draw
DHI361
1
4
1
3.8 Amp.
DHI421
1
4
1
3.8 Amp.
DHI482
2
4
2
6.8 Amp.
DHI542
2
6
2
7.1 Amp.
DHI602
2
6
3
7.1 Amp.
GENERAL SPECIFICATIONS
MODEL SPECIFIC SPECIFICATIONS
*
18” 1/4 on models DHI482, DHI542 and DHI602
Chimney can accommodate up to 10” round duct work
All tolerances: ±1/16” (±1.6 mm), -0, unless otherwise stated
WARNING
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the
accompanying installation instructions.
DO NOT install an additional in-line or external blower to
increase the length of the duct run. Even small differences
between blower air flow rates can greatly reduce the air draw
of the hood.
Document # PG07 - 002
Revised 10/21/09
Page 1/1
Maximum Duct Length
The maximum straight duct length for the hood is 50 feet. To determine the
actual maximum duct run, subtract the equivalent length of each elbow,
transition and cap from 50 feet. See the
Duct Planning Guide
or the
installation instructions for more details.
IMPORTANT:
The minimum installed distance from the hood to the cooking
surface must be no less than 30 inches. The minimum specified distance
may be higher for the particular range or cooktop in use. Check the
manufacturers specifications for the cooktop or range.