    OB36, OB52, OBS36, OBS52 36 instructions. All tolerances: +1/16" (+1.6 mm), -0, unless otherwise stated Revised 01/11/11 Page 1/3 PLANNING GUIDE cm) 36" (91.4 cm) *Total depth with handle: 30" (76.2 cm) oB[S]36 overall dimensions Model Type Natural Gas LP Gas Electrical Dacor.com Minimum Gas Supply Pressure
  • Dacor OBS36 | Planning Guides - Page 2
    001 OB36, OB52, OBS36, OBS52 36", 52" Wide Outdoor Grills Revised 01/11/11 Page 2/3 PLANNING GUIDE All tolerances: +1/16" (+1.6 mm), -0, unless otherwise stated OB[S]36 - 36 1/2" (92.7 cm) OB[S]52 - 52 1/2" (133.4 cm) 9" (22.8 cm) max. 3/4" (1.9 cm) min. to any material for 36" ventilation
  • Dacor OBS36 | Planning Guides - Page 3
    OB36, OB52, OBS36, OBS52 36", 52" Wide Outdoor Grills All tolerances: +1/16" (+1.6 mm), -0, unless otherwise stated Revised 01/11/11 Page 3/3 PLANNING GUIDE - 1 OBAD36 - 2 Accessory Door Cutout Dimensions Specifications subject to change without notice. www.Dacor.com Phone: (800) 7913-30.0393
  • 1
  • 2
  • 3

PLANNING
GUIDE
Specifications subject to change without notice.
Phone: (800) 793-0093
www.Dacor.com
36”, 52” Wide Outdoor Grills
OB36, OB52, OBS36, OBS52
9 1/8"
(23.2 cm)
23 3/4"
(60.3 cm)
26 1/2"
(67.3 cm)
27” *
(68.6 cm)
36"
(91.4 cm)
25 1/8"
(63.8 cm)
9 1/8"
(23.2 cm)
23 3/4"
(60.3 cm)
26 1/2"
(67.3 cm)
27" *
(68.6 cm)
52"
(132.1 cm)
25 1/8"
(63.8 cm)
OB[S]36 OVERALL DIMENSIONS
OB[S]52 OVERALL DIMENSIONS
NOTE:
Supply access for the rotisserie power or an alternate 120 Vac duplex outlet location.
Model Type
Electrical Circuit Required
Total Connected Load
Gas Type
Manifold Pressure
Minimum Gas Supply
Pressure
Natural Gas
120 Vac, 60 Hz, 15 Amp.
2.9 Amps (0.35 kW)
Natural
4” Water column
5” Water column
LP Gas
120 Vac, 60 Hz, 15 Amp.
2.9 Amps (0.35 kW)
Propane
11” Water column
12” Water column
*Total depth with handle: 30” (76.2 cm)
All tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated
Document # PG13-001
Revised 01/11/11
Page 1/3
WARNING
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the
accompanying installation instructions.