Dell External OEMR R620 Owners Manual - Page 119
Review System Event Log and Operating System Logs. If the issue persists, see, Message Information
View all Dell External OEMR R620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 119 highlights
Error Code Message Information BAT0002 Message LCD Message Details Action The system board battery has failed. The system board battery has failed. Check battery. The system board battery is either missing or bad. See Getting Help. BAT0017 Message The battery has failed. LCD Message The battery has failed. Check battery. Details The battery is either missing, bad, or unable to charge due to thermal issues. Action Check system fans. If the problem persists, see Getting Help. CPU0000 Message CPU has an internal error (IERR). LCD Message CPU has an internal error (IERR). Details System Event Log and Operating System Logs may indicate that the exception is external to the processor. Action Review System Event Log and Operating System Logs. If the issue persists, see Getting Help. CPU0001 Message CPU has a thermal trip (over-temperature) event. LCD Message CPU has a thermal trip. Check CPU heat sink. Details The processor temperature increased beyond the operational range. Action Review the logs for fan failures. If no fan failures are detected, check inlet temperature (if available) and reinstall processor heat sink. If the problem persists, see Getting Help. CPU0005 Message LCD Message Details Action CPU configuration is unsupported. CPU configuration is unsupported. Check CPU or BIOS revision. System is unable to boot or may run in a degraded state. Review the technical specifications for supported processor types. CPU0010 Message Details Action CPU is throttled. The CPU is throttled due to thermal or power conditions. Review system logs for power or thermal exceptions. CPU0023 Message LCD Message Action CPU is absent. CPU is absent. Check CPU. Verify processor installation. If present, re-seat the processor. 119