Dell External OEMR XL R210II Technical Guide

Dell External OEMR XL R210II Manual

Dell External OEMR XL R210II manual content summary:

  • Dell External OEMR XL R210II | Technical Guide - Page 1
    Dell PowerEdge R210 Technical Guide 1-socket 1U rack server providing the features you need without a lot of the unnecessary extras.
  • Dell External OEMR XL R210II | Technical Guide - Page 2
    of any kind. Dell, PowerEdge, PowerVault, OpenManage, and ReadyRails are trademarks of Dell, Inc. Citrix® InfiniBand is a registered trademark and service mark of the InfiniBand Trade Association . Dell disclaims proprietary interest in the marks and names of others. ©Copyright 2010 Dell Inc
  • Dell External OEMR XL R210II | Technical Guide - Page 3
    Dell Table of Contents 1 Product Comparison 7 2 New Technologies 11 2.1 Overview 11 2.2 Detailed Information 11 2.2.1 System Management 11 2.2.2 Software Level 27 5.4 Power Supply Unit (PSU) Specifications 28 5.5 ENERGY STAR® Compliance 28 5.6 Thermal 28 PowerEdge R210 Technical Guide 3
  • Dell External OEMR XL R210II | Technical Guide - Page 4
    Dell 5.7 Acoustics 29 6 Processors 31 6.1 Overview 31 6.2 Supported Processors 31 6.3 Processor Configurations 31 7 Memory 32 7.1 Overview 32 7.2 DIMMs Supported Overview 39 9.2 ACPI 40 9.3 Power Management Modes 40 9.3.1 Dell Active Power Controller 40 9.3.2 Power Saving BIOS Setting (OS
  • Dell External OEMR XL R210II | Technical Guide - Page 5
    Dell Enterprise 58 17 Peripherals 61 17.1 USB 61 17.2 USB Device 61 17.3 External Storage 62 18 Packaging Options 62 Table 1. Table 2. Table 3. Table 4. Specifications 28 Acoustical Specifications 29 Processor Information 31 Supported Processor Configurations 32 Wake Up Events and States
  • Dell External OEMR XL R210II | Technical Guide - Page 6
    Dell Table 17. Table 18. Table Supported Microsoft Operating Systems 53 Supported Linux Operating Systems 54 Supported Virtualization OS 55 Unified Server Configurator Features and Description 58 Features List for BMC, iDRAC6, and vFlash 59 USB Controller Priorities 61 External Guide 6
  • Dell External OEMR XL R210II | Technical Guide - Page 7
    of the server for ease of monitoring and troubleshooting condition of the server. It was designed to Dell server and provides IT administrators with a consolidated console view of their IT infrastructure. Built with cost-effective RAID options to further protect your valuable data, new eSATA external
  • Dell External OEMR XL R210II | Technical Guide - Page 8
    Dell Table 1. Comparison of PowerEdge Server Features Feature Processor Front Side ECC or Registered w/ECC 1333/1066MHz 512MB/8GB 1GB/32GB 2 x 3.5" 4 x 3.5" Optional Hot-Swap Support 2.5" HDDs via Hot-Swap tray Default SATA. Optional SAS via addin controller Default SATA. Optional SAS and
  • Dell External OEMR XL R210II | Technical Guide - Page 9
    , Add-in RAID, toolless chassis BMC, IPMI 2.0 compliant; Full Dell™ OpenManage™ suite Optional; iDRAC6 Express, iDRAC6 Enterprise, vFlash DRAC4 Full Dell™ OpenManage™ suite 1 x PCIe x16 (True x16, Gen2); full height, half length Support x16 bandwidth card under 25W Riser 1: One PCIex 8, one PCIe
  • Dell External OEMR XL R210II | Technical Guide - Page 10
    Dell Feature RAID NIC/LOM USB Power Supplies Fans Form Factor Dimensions (HxWxD) R210 See Optional Storage Controller row above 2x GbE LOM w/o TOE Optional: various .10" x 24.00" Weight Max. 17.76 lbs (8.058 Kg) Max. 28.7 lbs (13.01 Kg) Max. 33.02 lbs (15 Kg) PowerEdge R210 Technical Guide 10
  • Dell External OEMR XL R210II | Technical Guide - Page 11
    Dell PowerEdge RAID controller portfolio now offers Enterprise Software RAID in the PERC S100 and PERC S300 options. PERC S100 and S300 are supported support, solution supports up Dell SAS HBA (leveraging SAS 6/iR) and allows for both SAS and SATA connectivity. PERC S300 controller solution supports
  • Dell External OEMR XL R210II | Technical Guide - Page 12
    ICH10R 3Gb SAS/SATA (SAS 1.1) Dell 3Gb/s SAS Adapter (2 internal Support Not Supported Not Supported Storage Management OpenManage™ 6.2 or later OpenManage 6.2™ or later Note: Microsoft Windows Server 2003 R2 is supported with Service Pack 2. For the most PowerEdge R210 Technical Guide
  • Dell External OEMR XL R210II | Technical Guide - Page 13
    , see the Operating System Support Matrix for Dell PowerEdge Systems on Dell.com. 2.2.3 eSATA External Serial Advanced Technology Attachment (eSATA) serves as an external interface for SATA technologies. For customers who want fast (up to 1.5Gbit/s), easyto-use external storage that has advanced
  • Dell External OEMR XL R210II | Technical Guide - Page 14
    Dell 3 System Overview Feature Form Factor Internal Controllers: SAS 6/iR PERC S100 (software-based) PERC S300 (software-based) PERC H200 External Controllers: PERC 6/E with 256MB or 512MB of battery-backed cache SAS 5/E PERC H800 LSI2032 PCIe , TOE/ISCI PCIe x4 PowerEdge R210 Technical Guide 14
  • Dell External OEMR XL R210II | Technical Guide - Page 15
    compliant Dell™ OpenManage™ featuring Dell Management Console Unified Server Configurator Lifecycle Controller enabled via optional: iDRAC6 Express, iDRAC6 Enterprise and vFlash Support for Static OS Option: Microsoft® Windows Server® 2008, with Hyper-V™ PowerEdge R210 Technical Guide 15
  • Dell External OEMR XL R210II | Technical Guide - Page 16
    Dell 4 Mechanical 4.1 Chassis Description The PowerEdge R210 is a 1-socket 1U server. The configuration details are as follows: • HDD Type : 2x 3.5" Cabled HDD or 2 x 2.5" Yb Yc with bezel bezel Zb* N/A N/A 31.35 NA 393.7 L6 Sys Wgt Zc (Kg) 397.49 5.95 PowerEdge R210 Technical Guide 16
  • Dell External OEMR XL R210II | Technical Guide - Page 17
    Dell Figure 1. Server Dimensions * Zb goes to the nominal rear wall external surface where the motherboard I/O connectors reside. 4.3 Front Panel View and Features Figure 2. Front Panel View PowerEdge R210 Technical Guide 17
  • Dell External OEMR XL R210II | Technical Guide - Page 18
    Dell 4.4 Back Panel View and Features Figure 3. Back Panel View 4.5 Power Supply Indicators 4.5.1 Power Button LED during non-operational (standby, shutdown) modes to enable system identification. 4.6 NIC Indicators See the Hardware Owner's Manual for information. PowerEdge R210 Technical Guide 18
  • Dell External OEMR XL R210II | Technical Guide - Page 19
    Dell 4.7 Side View Figure 5. Side View PowerEdge R210 Technical Guide 19
  • Dell External OEMR XL R210II | Technical Guide - Page 20
    Dell 4.8 Internal Chassis View Figure 6. Internal Chassis View PowerEdge R210 Technical Guide 20
  • Dell External OEMR XL R210II | Technical Guide - Page 21
    Dell 4.9 Rails ReadyRails™ static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post for the R210, see Section 13. Figure 7. R210 Static Rails Figure 8. R210 Mounted In Four-Post Square-Hole Rack PowerEdge R210 Technical Guide 21
  • Dell External OEMR XL R210II | Technical Guide - Page 22
    Dell 4.10 Fans There are three system fans located in the middle of the system. Figure 9. System Fans 4.11 Control Panel LED See the Hardware Owner's Manual 1.2 compliant encryption chip solution on the system board with BIOS support worldwide, except for China where Trusted Computing Module (TCM)
  • Dell External OEMR XL R210II | Technical Guide - Page 23
    Dell Table 7. TPM Pin Signals Pin SIGNAL 1 TPM_PRES_N 2 LPC_LAD0 3 GND 4 LPC_LAD1 5 SEEPROM I2C Address E0 6 P3V3_AUX 7 RST_TPM_R_N 8 LPC_LFRAME_N 9 GND switch detects and alerts the user that the side cover is open. Figure 10. Intrusion Switch PowerEdge R210 Technical Guide 23
  • Dell External OEMR XL R210II | Technical Guide - Page 24
    Dell 4.12.6 Secure Mode BIOS has the ability to enter a secure boot mode via setup. This mode includes the option to lock out the power and NMI switches on the control panel or set up a system password. See the BIOS specification in the Hardware Owner's Manual ). PowerEdge R210 Technical Guide 24
  • Dell External OEMR XL R210II | Technical Guide - Page 25
    ) The planar contains a 16K x 8 serial EEPROM to store FRU information including Dell part number, part revision level, and serial number. This information is used by System fan 4.16 User Accessible Jumpers, Sockets, and Connectors See the Hardware Owner's Manual. PowerEdge R210 Technical Guide 25
  • Dell External OEMR XL R210II | Technical Guide - Page 26
    Dell 5 Power, Thermal, Acoustic 5.1 Power Supplies The base system includes a single 250W power supply. This unit provides power to the planar and P5V 23 P5V 24 GND Pin SIGNAL 1 GND 2 GND Table 9. Power Supply 4 Pins and Signals Pin SIGNAL 3 P12V2 4 P12V2 PowerEdge R210 Technical Guide 26
  • Dell External OEMR XL R210II | Technical Guide - Page 27
    Dell 5.3 Environmental Specifications 5.3.1 Temperature Operating: 10° to 35°C (50° to 95°F) with a maximum temperature gradation of 10°C per hour (NOTE: For 50 to 35,000 ft) 5.3.6 Airborne Contaminant Level Class: G2 or lower as defined by ISA-S71.04-1985 PowerEdge R210 Technical Guide 27
  • Dell External OEMR XL R210II | Technical Guide - Page 28
    power supply handle or ejection tab 5.5 ENERGY STAR® Compliance See the ENERGY STAR Compliance results on Dell.com. 5.6 Thermal The thermal design of the PowerEdge R210 reflects the following: • Closed loop thermal according to what the system really needs. PowerEdge R210 Technical Guide 28
  • Dell External OEMR XL R210II | Technical Guide - Page 29
    humans respond to annoyances in sound, like whistles, hums, etc. One of the sound quality metrics in the Dell specification is prominence ratio of a tone, as listed in the table below. • Noise ramp and descent at prominent. The system is placed in a rack with its PowerEdge R210 Technical Guide 29
  • Dell External OEMR XL R210II | Technical Guide - Page 30
    Dell bottom at 75 cm from the floor. The acoustic transducer is at front bystander position, ref ISO7779 (1999) Section 8.6.2. PowerEdge R210 Technical Guide 30
  • Dell External OEMR XL R210II | Technical Guide - Page 31
    Dell 6 Processors 6.1 Overview The PowerEdge R210 is a 1S, entry-level server based on the Intel FCLGA1156 to support Intel Xeon 3400 series and Core i3 processors. 6.2 Supported Processors Model Table 12 . The memory controller is embedded in the processor. PowerEdge R210 Technical Guide 31
  • Dell External OEMR XL R210II | Technical Guide - Page 32
    Dell 7 Memory 7.1 Overview Features of the PowerEdge R210 memory include: • 2 channels per processor • Support for Unbuffered ECC DDDR3 DIMMs. • Support for DDR3 speeds of 1066/1333 • 4 DIMM sockets (16GB Maximum capacity) • Support for Single Rank and Dual Rank DIMMs 7.2 DIMMs Supported Guide 32
  • Dell External OEMR XL R210II | Technical Guide - Page 33
    Dell System System Memory DIMM DIMM_T DIMM NUM_DI Capacity Speed Speed ECH Module • 4GB, DIMM Module 7.4 Speed The PowerEdge R210 supports 1066/1333MHz DDR3 memory. 7.5 Sparing Not supported. 7.6 Mirroring Not supported. 7.7 RAID Memory RAID is not supported. PowerEdge R210 Technical Guide 33
  • Dell External OEMR XL R210II | Technical Guide - Page 34
    Dell 8 Chipset 8.1 Overview The PowerEdge R210 planar incorporates the Intel Ibex Peak as PCH chipset. The Ibex Peak is a highly integrated I/O controller. The high-level features supported servicing support independent DMA operation on up to six ports and supports that supports up to four external PCI
  • Dell External OEMR XL R210II | Technical Guide - Page 35
    the functionality of two, 82C59 interrupt controllers. The two interrupt controllers are cascaded so that 14 external and two internal interrupts are possible. In addition, the Ibex Peak supports a serial interrupt scheme. All of the registers in these modules can be read and restored. This
  • Dell External OEMR XL R210II | Technical Guide - Page 36
    Dell battery. The RTC also supports two lockable memory ranges. By . The RTC also supports a date alarm that support an external microcontroller instruction after reset. If the processor does not fetch the first instruction instruct the Ibex Peak to generate an SMI#, NMI, SERR#,
  • Dell External OEMR XL R210II | Technical Guide - Page 37
    Dell 8.15.4 Function Disable The Ibex Peak provides the ability to Intel VT-d). Intel VT-d Technology consists of technology components that support the virtualization of platforms based on Intel Architecture Processors. Intel its own subset of host physical memory. PowerEdge R210 Technical Guide 37
  • Dell External OEMR XL R210II | Technical Guide - Page 38
    Dell 8.19 JTAG Boundary-Scan Ibex Peak adds the industry standard JTAG interface and enables Boundary-Scan in place of the XOR chains used chain. This eases pin breakout and trace routing and simplifies the interface between the system and a bed-of-nails tester. PowerEdge R210 Technical Guide 38
  • Dell External OEMR XL R210II | Technical Guide - Page 39
    BIOS 1.0a compliant • MP 1.4 • SMBIOS 2.5 • USB 1.1 with legacy USB support • USB 2.0 support in BIOS during pre-boot • Dell Server Assistant 7.0 support • System Service support • iDRAC supported • Error logging via ESM • ACPI 2.0 support (S0, OS-S4, S5 states) • I2O v1.5 ready • Selectable Boot
  • Dell External OEMR XL R210II | Technical Guide - Page 40
    : S0, S4, S5 supported NO S1, S2, S3 (STR) support. S4 will be supported by OS support only. Table 14. Wake supported S5, OS-S4 Not supported Not supported Not supported S5, OS-S4 9.3 Power Management Modes 9.3.1 Dell Active Power Controller The Dell Active Power Controller (DAPC) is a Dell
  • Dell External OEMR XL R210II | Technical Guide - Page 41
    Dell 9.3.2 Power Saving BIOS Setting (OS Control) Intel processors support supported the OS. Dell provides ASL code states Fixed PCH Supported states: S0(Working), S4-OS (' 'suspend') and S3 are not supported. Power Button Fixed PCH In Dell defined ASL routine handles the event. Wake-on
  • Dell External OEMR XL R210II | Technical Guide - Page 42
    Dell USB wake Generic N/A This feature is not supported on this system since the S1 state is not supported. DBS N/A C State N/A Support Power Profile N/A support Processor MSRs |800Mhz| Minimum Power Fan Algorithm Maximum Performance | Minimum Power PowerEdge R210 Technical Guide 42
  • Dell External OEMR XL R210II | Technical Guide - Page 43
    Dell 10 I/O Slots 10.1 Overview The PowerEdge R210 system provides: • Riser support x16 PCIe card (Gen2 link x16) • Support x16 bandwidth card under 25W Figure 13. PCIe x16 Riser Card PowerEdge R210 Technical Guide 43
  • Dell External OEMR XL R210II | Technical Guide - Page 44
    Dell Figure 14. SAS 6/iR Adapter Card Installed 10.2 PCI Devices Xeon 3400 Series CPU PCI devices include: • Intel QuickPath Rank • Integrated Memory Controller Channel 1 Thermal Control • DMI Root Port • PCI Express Root Port 1 • PCI Express Root Port 3 PowerEdge R210 Technical Guide 44
  • Dell External OEMR XL R210II | Technical Guide - Page 45
    Dell • Core Addressing Mapping, Intel VT-d, System Management • Core Semaphore and Scratchpad Registers • Core System Control/Status Registers • Slot # 1 Table 17. I/O Slot Information Mechanical PCIe x 16 Electrical PCIe x 16 Gen 2 Height Full Length Half PowerEdge R210 Technical Guide 45
  • Dell External OEMR XL R210II | Technical Guide - Page 46
    Controllers External Storage Controllers Optional NICs Description Dell™ SAS 6iR Adapter (SASRAID) Dell™ PERC S300 (SW RAID) Dell™ PERC H200 (HW RAID) Dell™ SAS 5E Adapter Dell™ PERC Card with TOE and iSCSI Offload Slot Priority 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 PowerEdge R210 Technical Guide 46
  • Dell External OEMR XL R210II | Technical Guide - Page 47
    Dell 10.3 Boot Order The PowerEdge R210 supports only 1 PCIe x8 slot. 10.4 NICs There is Broadcom 5716 chip on the PowerEdge R210 motherboard. The chip is connected to the PCH via a PCI Express x4 gen2 link. Broadcom 5716 does not support TOE (TCP Offload Engine). The chip provides two Gigabit
  • Dell External OEMR XL R210II | Technical Guide - Page 48
    Dell 11 Storage 11.1 Overview The PowerEdge R210 supports up to 2 HDDS: • 2 x 2.5"/ 3.5" cabled SATA or SSD from motherboard SATA connector • 2 x 2.5"/ 3.5" cabled SAS, SSD, , or 450GB, 600GB 3.5"/10K: 600GB 2.5"/10K: 146 or 300GB HDD/SSD 2.5": or 50GB, 100GB PowerEdge R210 Technical Guide 48
  • Dell External OEMR XL R210II | Technical Guide - Page 49
    Dell Optical Disk Drive (ODD) The PowerEdge R210 will support up to 1 slim type internal optical drive and optional external USB DVD-ROM. The PowerEdge R210 can boot from either the internal optical drive or the optional external drive and supports
  • Dell External OEMR XL R210II | Technical Guide - Page 50
    Dell 11.5 Tape Drives Table 22. Supported Tape Drives PV DAS External TBU External TBU/Automation PowerVault™ MD1000 PowerVault™ MD3000 PowerVault™ MD1120 PowerVault™ RD1000 PowerVault™ 114X PowerVault™ DAT 72 PowerVault™ LTO-3-060 PowerVault™ 110T LTO-3 PowerVault™ LTO4-120 PowerVault™
  • Dell External OEMR XL R210II | Technical Guide - Page 51
    Dell 12 Video and Audio 12.1 Video Matrox® G200eW w/ 8MB memory integrated in Winbond® WPCM450 (BMC controller): • 640x480 (60/72 (60/75/85 Hz; 8/16-bit color) • 1280x1024 (60 Hz, 32-bit color) 12.2 Audio The PowerEdge R210 does not support audio (sound card or speakers). PowerEdge R210 Technical
  • Dell External OEMR XL R210II | Technical Guide - Page 52
    racks via Dell's ReadyRails™ mounting interface. The rails also support a " Static Rack Types Supported 4-Post 2-Post support a wide variety of racks and mounting configurations but do not support the ability to extend the system out of the rack for service. Thus, they do not provide support
  • Dell External OEMR XL R210II | Technical Guide - Page 53
    Systems For the most up-to-date information, see the Operating System Support Matrix for Dell PowerEdge Systems on Dell.com. Operating Systems Windows® Essential Business Server Microsoft® Hyper-V™ Server WHQL Test Only WHQL WHQL FI (WLK1.4) WHQL FI (WLK1.4) PowerEdge R210 Technical Guide 53
  • Dell External OEMR XL R210II | Technical Guide - Page 54
    Dell Table 25. Supported Linux Operating Systems Operating Systems Red Hat® Enterprise Linux® 4.8 x86 or x64 x86-64 x86 Installation ES ES Factory Install DIB, NFI S11 x86-64 X86-64 Enterprise Enterprise ES ES FI Yes DIB, NFI Yes DIB, NFI Yes FI Yes PowerEdge R210 Technical Guide 54
  • Dell External OEMR XL R210II | Technical Guide - Page 55
    ™ suite: vRanger™ Pro vConverter™ vReplicator vFoglight™ Supported; not offered through Dell (No FI nor DIB) Supported; not offered through Dell (No FI or DIB) Website download fulfillment; instructions are DIB Website download fulfillment; instructions are DIB PowerEdge R210 Technical Guide 55
  • Dell External OEMR XL R210II | Technical Guide - Page 56
    -specific schema class definitions and their installation are also included on the DVD. • Dell Systems Service Diagnostics Tools: Dell Systems Service and Diagnostics tools deliver the latest Dell optimized drivers, utilities, and operating system-based diagnostics that you can use to update your
  • Dell External OEMR XL R210II | Technical Guide - Page 57
    Documentation and Dell Management Console The optional iDRAC (Integrated Dell Remote Access Controller) is Dell Lifecycle Controller • Dell Unified Server Configurator • iDRAC6 (Integrated Dell drivers, etc.). Dell Unified Server Configurator within 10 seconds of the Dell logo's appearance during the
  • Dell External OEMR XL R210II | Technical Guide - Page 58
    Integration with Dell support automatically directed to power states • Advanced troubleshooting capabilities For more information iDRAC6 Enterprise include: • Scripting capability with Dell's Racadm command-line • Remote video, a 1 GB Dell branded SD card that enables a persistent 256
  • Dell External OEMR XL R210II | Technical Guide - Page 59
    Dell flash partition. A more detailed feature list for iDRAC6 Enterprise and vFlash is included in the following table. Table 28. Features List for BMC, iDRAC6, and vFlash Feature BMC iDRAC6 Express Interface and Standards Support            PowerEdge R210 Technical Guide 59
  • Dell External OEMR XL R210II | Technical Guide - Page 60
    Dell Feature capture BMC iDRAC6 Express Boot capture  Serial-over-LAN  Virtual media Virtual console Virtual System Event Log   RAC Log  Trace Log * BMC availability through OpenManage iDRAC6 Enterprise    vFlash Media    PowerEdge R210 Technical Guide 60
  • Dell External OEMR XL R210II | Technical Guide - Page 61
    Dell 17 Peripherals 17.1 USB All PowerEdge systems have a minimum of 2 front-accessible USB 2.0 compliant ports with enough is disabled (e.g., when Back USB is disabled the Front USB ports are also disabled). 17.2 USB Device Optional external USB DVD-ROM. PowerEdge R210 Technical Guide 61
  • Dell External OEMR XL R210II | Technical Guide - Page 62
    Dell 17.3 External Storage Table 30. External Storage External Optical Drive (Optional) USB DVD-ROM MD1000 JBOD PowerVault™ DAS MD3000 RBOD MD1120 - 2.5 SAS/SATA JBOD RD1000 USB PV114T (2U) External TBU DAT 72 SCSI LTO3-060 SCSI LTO3FH SCSI LTO4-120 HH and FH SAS ML6000 External TBU/
  • Dell External OEMR XL R210II | Technical Guide - Page 63
    Dell 18 Packaging Options Options for single pack and multipack are available. Multipack will support 4 units in one pack. Table 31. AMF Single Pack Dimensions and Weights INSIDE DIMENSIONS OUTSIDE Box: 2.06 kg (4.55 lbs) Total Weight: 10.98 kg (24.2 lbs) PowerEdge R210 Technical Guide 63
  • Dell External OEMR XL R210II | Technical Guide - Page 64
    Dell Figure 16. Packaging PowerEdge R210 Technical Guide 64
  • Dell External OEMR XL R210II | Technical Guide - Page 65
    Dell Appendix A. Regulatory Certifications • FCC (U.S. only) Class A • ICES (Canada) Class A • CE Mark (EN 55022 Class A, EN55024, EN61000-3-2, EN61000 ) • UKRTEST (Ukraine) • UZBEKISTAN GOST (Uzbekistan) • KUCAS (Kuwait) • KSA-ICCP (Saudi Arabia) • MPT (Vietnam) PowerEdge R210 Technical Guide 65
  • Dell External OEMR XL R210II | Technical Guide - Page 66
    Dell Appendix B. R210 Volatility Tables Table 33. PowerEdge R210 Volatility Planar System BIOS SPI Flash NonVolatile Y LOM Configuration Y Data iDRAC6 , DIMM_ 4 up to 4 DIMMs 16GB RAM B1, DIMM_ B2 U_SEE PROM 1 256B EEPROM U21 1 256B EEPROM 66 PowerEdge R210 Technical Guide
  • Dell External OEMR XL R210II | Technical Guide - Page 67
    Dell iDRAC6 SDRAM NonVolatile iDRAC6 FRU Y iDRAC6 Boot Block Flash Y Trusted Platform Y Module Chipset CMOS Y Control Panel Internal USB Y iDRAC6 Enterprise vFlash Y Battery-backed RAM License key hard set ROM or user choice Secure Digital NAND Flash 67 PowerEdge R210 Technical Guide
  • Dell External OEMR XL R210II | Technical Guide - Page 68
    Dell Table 34. Volatility: Data Writing and Purpose Operating System; Yes for Managed System Services Repository Yes No Not used iDRAC Operating System plus Managed System Services Repository (i.e., Unified Server Configurator, OS -in module to a particular planar 68 PowerEdge R210 Technical Guide
  • Dell External OEMR XL R210II | Technical Guide - Page 69
    Dell Chipset CMOS Control Panel Can user programs booting up the system from a floppy or OS-based executable (currently only DRMK utility support) containing the firmware file and the loader. System loaded with arbitrary data in CPLD a non-functional iDRAC. 69 PowerEdge R210 Technical Guide
  • Dell External OEMR XL R210II | Technical Guide - Page 70
    Dell How is data input to this memory? Managed Services Repository: Various partitions are loaded using vendor-provided firmware file and loader program just like iDRAC OS. TPM ID ISO images, files) or local server read/write capability to use like a hard disk. 70 PowerEdge R210 Technical Guide
  • Dell External OEMR XL R210II | Technical Guide - Page 71
    Dell Table 36. Methodology for Memory Protection and Clearing Planar System BIOS SPI Flash LOM Configuration Data iDRAC6 Controller ROM iDRAC6 controller Not user clearable OS control Reboot or power down system HW read only Not clearable, read only 71 PowerEdge R210 Technical Guide
  • Dell External OEMR XL R210II | Technical Guide - Page 72
    Dell TPM Binding EEPROM (on China planar only) iDRAC6 SDRAM iDRAC6 FRU iDRAC6 Boot Block Flash Trusted Platform Module Chipset Locked by BIOS protection switch or OS control iDRAC-based format, local OS format, deleted, or card removed and formatted on a client 72 PowerEdge R210 Technical Guide
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

Technical Guide
1-socket 1U rack
server providing
the features you
need without a
lot of the
unnecessary
extras.
Dell PowerEdge R210