- Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 1
Dell Force10 S25 Systems Quick Start Guide Regulatory Model: S25N/S25V/S25P - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 2
- Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 3
Dell Force10 S25 Systems Quick Start Guide Regulatory Model: S25N/S25V/S25P - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 4
: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. If you purchased a Dell n Series computer, any references in this publication to Microsoft Windows operating - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 5
S25N and S25V Installing the S25P System power-up instructions Systems Software configuration FTOS Configuration Guide FTOS Configuration Guide Command line interface FTOS Command Line Reference Guide FTOS Command Line Reference Guide Latest updates FTOS Release Notes for the FTOS Release - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 6
4 About this Guide - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 7
, Dell Force10 recommends that you complete the installation procedures in the order presented below. NOTE: Unless stated otherwise, the installation instructions below apply to the S25N, S25V, and S25P systems. Always handle the system and its components with care. Avoid dropping the switch or - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 8
rack. Secure the unit with two of the supplied screws through each bracket and onto the rack post. S25N/V AC STACK ID XFP25 XFP26 Alarm DC 27 P28 S50-01-GE-24V S25P Stack ID AC1 XFP25 XFP26 AACla2rm 27 P28 S25-01-GE-24P 6 Installing the Hardware - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 9
switch is running. CAUTION: Before connecting a transceiver to a source, check the receive power of the transceiver with an optical power meter. Generally, Dell Force10 catalog number GP-SFP2-1T is used in the S25P switch, the SFP speed can be manually set with the speed command. When the speed is - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 10
that prevents it from being inserted incorrectly.). 2 Insert the SFP into the port until it gently snaps into place. S25N/V with SFP S25P with SFP S25-01-GE-24P 8 Installing the Hardware - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 11
XFP transceivers while the switch is operating. However, inserting or removing the module is not supported; it can crash or lock up the switch, requiring a reboot. into place. NOTE: For details on Dell Force10 supported optics, refer to http://www.force10networks.com/products/specifications.asp Installing - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 12
to the switch - AC only, DC only, or using both AC and DC sources. • To use AC only, connect the supplied AC power cord first to the switch (receptacle is secure. • For DC power, you must provide your own cables to connect to the power source. Cables must be sized for 11.5 A service at no more than - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 13
two terminal blocks for two DC power supply inputs acting in load-sharing mode. The left terminal block, as you face the PSU side, corresponds to the DC2 status LED on the I/O side of the switch; DC1 is on the right. Cables must be sized for 11.5 A service at -48VDC input (per NEC - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 14
the system and its components. Power Supplies On the S25N, S25V, and S25P systems, either the AC or DC power supplies alone are sufficient to power the switch. When both AC and DC power supplies are connected, they act in roughly a 60%/40% load-sharing mode. WARNING: To prevent electrical shock - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 15
non-operating (storage temperature) temperature) Maximum Thermal Output S25N: 349.05 BTU/Hour S25V: 349.05 BTU/Hour S25P: 305 BTU/Hour S25P-DC: 262 BTU/Hour Maximum altitude No performance degradation No performance degradation to 10,000 feet (3,048 meters) to 10,000 feet (3,048 meters - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 16
Requirements Parameter S25N/V Specifications S25P Specifications Nominal Input Voltage 90 - 254 VAC, 47/63 Hz S25P: 90 - 254 VAC, 47/63 Hz S25P-DC: -48 VDC Maximum Current Draw S25N: 2 A @ 100/120 VAC; 1 S25P: 2 A @ 100/120 VAC; 1 A @ 200/240 VAC A @ 200/240 VAC S25V (AC): 6.5 A @ 100/120 - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 17
2 Installing the Software Navigating CLI Modes The FTOS prompt changes to indicate the CLI mode. You must move linearly through the command modes, with the exception of the end command which takes you directly to EXEC Privilege mode; the exit command moves you up one command mode level. Console - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 18
Stack ID AC1 XFP25 XFP26 AACla2rm 27 P28 Step Task 1 Install the RJ-45 copper cable that is shipped with the system into the console port. CAUTION: You must install a straight-through RJ-45 copper cable (a standard Ethernet cable) into the console port. This is different from many other - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 19
can modify the settings to match at each end of the connection. 4 S25P only: If you use the console port to download software to the switch, you will probably want to raise the console baud rate. Establish a connection with the default settings to verify the connection. Then use the lineconfig - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 20
Dell Force10 Operating System (FTOS) is pre-loaded onto the chassis, however the system is not configured when you power up for the first time (except for the default hostname, which is Force10 2 Place the interface in switchport Layer 2 (switching) mode. Command Mode INTERFACE INTERFACE To view - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 21
The S25N, S25V, and S25P systems do not have a dedicated management port, nor a separate management routing able. Configure any port on one of the chassis to be the port through which you manage the system and configure an IP route to that gateway. Step Task Command Syntax 1 Configure an IP - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 22
using a DES encryption method. • enable secret is stored in the running/startup configuration in using a stronger, MD5 encryption method. Dell Force10 recommends using the enable secret password. Task Command Syntax Create a password to enable [password | secret] [level level] access EXEC - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 23
Create a VLAN The Default VLAN is part of the system startup configuration, and is by default, VLAN 1. You may make another VLAN the Default VLAN. The Default VLAN cannot be deleted, disabled, or configured (you cannot assign it an IP address), and only untagged interfaces can belong to it. When an - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 24
Step Task Command Syntax 1 Assign a switchport to [tagged | untagged] interface a VLAN. 2 Display all show vlan switchports and the VLANs of which they are members. Command Mode INTERFACE VLAN EXEC Privilege Assign an IP address to a VLAN NOTE: An IP address cannot be assigned to the - Dell Force10 S25-01-GE-24V | Quick Start Guide for the S25 System - Page 25