Dell PowerConnect B-TI24x Hardware Installation Guide

Dell PowerConnect B-TI24x Manual

Dell PowerConnect B-TI24x manual content summary:

  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 1
    53-1002265-01 18 March 2011 Dell PowerConnect BSeries TI24X Hardware Installation Guide
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 2
    of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell, the DELL logo,, Dell OpenManage and PowerConnect are trademarks of Dell Inc.; Microsoft, Windows, Windows Server, MS-DOS and Windows Vista are either
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 3
    Contents About This Document In this chapter vii Audience vii Supported hardware and software vii Document conventions vii Text formatting site 15 Cabling infrastructure 15 Installation location 15 Dell PowerConnect B-Series TI24X Hardware Installation Guide iii 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 4
    route 31 Troubleshooting network connections 31 Support for digital optical monitoring 31 Managing the PowerConnect B-Series TI24X In this PowerConnect B-Series TI24X Hardware In this chapter 37 Hardware maintenance schedule 37 iv Dell PowerConnect B-Series TI24X Hardware Installation Guide
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 5
    39 Installation precautions and warnings 40 Determining which power supply failed 40 AC power supplies 41 Replacing the fan tray 45 Installation precautions and warnings power cords 63 Korea 63 China RoHS 64 Dell PowerConnect B-Series TI24X Hardware Installation Guide v 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 6
    Appendix C Caution and Danger Notices Cautions 65 Danger 68 vi Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 7
    hardware platform is supported by this release of this guide: • PowerConnect B-Series TI24X Series Document conventions This section describes text formatting conventions and important notice formats used in this document. Dell PowerConnect B-Series TI24X Hardware Installation Guide vii 53
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 8
    this manual. They are listed below in order of increasing severity of potential hazards. NOTE A note provides a tip, guidance or advice, emphasizes important information, or provides a reference to related information. viii Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 9
    and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues: Dell PowerConnect B-Series TI24X Hardware Installation Guide ix 53-1002265
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 10
    your country or region at the bottom of the page. For a full listing of countries and regions, click All. 3. In the Support menu, click All Support. 4. Choose the method of contacting Dell that is convenient for you. x Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 11
    for converged services. The PowerConnect B-Series TI24X supports: • PowerConnect B-Series TI24X models. For details about physical dimensions, power supply specifications, and pin-outs, refer to Appendix A, "Hardware Specifications". Dell PowerConnect B-Series TI24X Hardware Installation Guide
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 12
    10/100/1000 Mbps copper ports, supporting 100Base-TX and 1000Base-T RJ-45 connectors Control features PowerConnect B-Series TI24X front panel has the following control features: in the upper right of the front panel. 2 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 13
    link, and adjusts port speed accordingly. The Management port on the PowerConnect B-Series TI24X supports RJ-45 copper connectors, auto MDI or MDIX detection, and has : EMPTY Port 11: Type : EMPTY Port 12: Type : EMPTY Dell PowerConnect B-Series TI24X Hardware Installation Guide 3 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 14
    : 1G M-C (Gig-Copper) Port 28: Type : 1G M-C (Gig-Copper) 10 Gbps ports Ports 1 - 24 support 1-GbE SFP transceivers and 10-GbE SFP and SFP+ transceivers listed in Table 1. Figure 3 shows ports 1 - 24. speed accordingly. 4 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 15
    PowerConnect B-Series TI24X support auto MDI or MDIX detection. For more information about this feature, refer to "Configuring MDI/MDIX" in the PowerConnect B-Series TI24X Configuration Guide received on the copper port. Dell PowerConnect B-Series TI24X Hardware Installation Guide 5 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 16
    left side of the front panel (when facing the front of the device) State On Off AC OK Upper center of power supply's On front panel (when facing the rear of the device) to "Power supply specifications" on page 55. 6 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 17
    (the device can be running while a power supply is being installed or removed, but the power supply itself should not be connected to a power source). Dell PowerConnect B-Series TI24X Hardware Installation Guide 7 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 18
    1 Hardware features 8 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 19
    Dell PowerConnect B-Series TI24X device with dual AC power supplies installed • AC PDU power cords (C13-C14) • Document kit • Retainer nuts and screws • Rubber feet • Rack mount kit (includes rack mount brackets, retainer nuts and screws) Dell PowerConnect B-Series TI24X Hardware Installation Guide
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 20
    using the CLI. You also can use Brocade PowerConnect B-Series TI24X Network Advisor to manage the device. Configuration Guide 11 Secure access to the device. PowerConnect B-Series TI24X Configuration Guide 10 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 21
    precautions 2 Installation precautions Follow these precautions when installing a Dell PowerConnect device. General precautions CAUTION Do not install the device DANGER All fiber-optic interfaces use Class 1 lasers. Dell PowerConnect B-Series TI24X Hardware Installation Guide 11 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 22
    above. Power precautions The following precautions apply to PowerConnect B-Series TI24X devices: CAUTION Use a separate branch circuit for each AC power cords , to provide redundancy in case the fan vent is on the right. 12 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 23
    power supply is designed exclusively for use with PowerConnect B-Series TI24X devices. Installing the power supply in a device other than the PowerConnect B-Series TI24X will cause extensive damage to your equipment. Dell PowerConnect B-Series TI24X Hardware Installation Guide 13 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 24
    Dispose of used battery according to the instructions. DANGER Disconnect the power cords from all AC power supply. DANGER Power supplies are hot swappable. However, Dell recommends that you disconnect the power supply from AC Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 25
    mount installation,the Dell PowerConnect B-Series TI24X supports the use of a two post Telco equipment rack and four post equipment rack. NOTE For additional support under the stack of switches. Use Dell 1U shelf, Dell p/n:G118R. Dell PowerConnect B-Series TI24X Hardware Installation Guide 15 53
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 26
    of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. 16 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 27
    the PowerConnect B-Series TI24X and would invalidate your warranty. Figure 5 shows how to attach the short mounting brackets. FIGURE 5 Attaching the short mounting brackets Mount the device in the rack as illustrated in Figure 6. Dell PowerConnect B-Series TI24X Hardware Installation Guide 17
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 28
    package. • Attach the AC PDU power cords (C13-C14) to the AC connector on the rear panel as shown in Figure 7. NOTE Align the locating notch on the underside of the AC PDU power cords (C13-C14) before inserting. 18 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 29
    working properly (refer to "Verifying proper operation".) Powering off the system To turn an AC system OFF: • Unplug the PDU power cords(C13-C14) from the power source. on specific LED conditions after system start-up. Dell PowerConnect B-Series TI24X Hardware Installation Guide 19 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 30
    State Pwr (Power) Left-most LED on the On front panel Off AC OK On power supply 1 front On panel AC OK Off On power supply 2 front On panel Off Meaning The device • Data bits: 8 • Parity: None • Stop bits: 1 20 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 31
    with a female DB-9 connector. Terminal connections will vary, requiring either a DB-9 or DB-25 connector, male or female. Serial cable options between a Dell switch or router and a PC or terminal are shown in Figure 9. Dell PowerConnect B-Series TI24X Hardware Installation Guide 21 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 32
    the wires should not be connected. If you do connect the wires that are labeled "Reserved", you might get unexpected results with some terminals. 22 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 33
    connectivity 29 •Troubleshooting network connections 31 Assigning permanent passwords DANGER The procedures in this manual are intended for qualified service personnel. before you can set other types of passwords. Dell PowerConnect B-Series TI24X Hardware Installation Guide 23 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 34
    flash primary at the prompt. This command causes the device to bypass the system password check. 6. After the console prompt reappears, assign a new password. 24 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 35
    in your network. Dell PowerConnect devices support both classical IP PowerConnect(config)# ip default-gateway 192.22.3.1 NOTE You do not need to assign a default gateway address for single subnet networks. Syntax: enable [] Dell PowerConnect B-Series TI24X Hardware Installation Guide
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 36
    Dell PowerConnect devices. Connectors and cable specifications Refer to "Cable specifications" on page 53 for cable lengths and types supported on the PowerConnect B-Series TI24X PowerConnect B-Series TI24X Configuration Guide. 26 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 37
    or MDIX detection All 10/100/1000 Copper ports on the Dell PowerConnect B-Series TI24X devices support automatic Media Dependent Interface (MDI) and Media Dependent Interface Crossover designate the port as an MDIX port. Dell PowerConnect B-Series TI24X Hardware Installation Guide 27 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 38
    For more information about this feature and how configure it, refer to the PowerConnect B-Series TI24X Configuration Guide. Connecting a network device to a fiber port For direct attachment from the Dell PowerConnect device to a Gigabit NIC, switch, or router, fiber cabling with an LC connector
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 39
    Testing connectivity 3 Fiber-optic connectors To avoid problems with the connection between the fiber optic module (SFP (mini-GBIC) or the IP broadcast address, the device lists the first four responses to the ping. Dell PowerConnect B-Series TI24X Hardware Installation Guide 29 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 40
    configuration change. You can use the CLI. If you have configured an IP address on the device, you also can use Brocade Network Advisor. If a problem persists after taking these actions, contact Dell technical support. 30 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 41
    to the destination, the Dell PowerConnect device displays up to three responses by default. Troubleshooting network connections • For the PowerConnect B-Series TI24X Configuration Guide. • If the other procedures don't resolve the problem, try using a different port or a different cable. Support
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 42
    3 Troubleshooting network connections 32 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 43
    chassis Power supply 1 (NA - NA - Regular) present, status ok Power supply 2 not present Fan 1 ok, speed (auto): [[1]]23 Fan 2 ok, speed (auto): [[1]]23 Fan 3 ok, speed (auto): [[1]]23 Dell PowerConnect B-Series TI24X Hardware Installation Guide 33 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 44
    reaches or exceeds the configured shutdown level for five minutes. The PowerConnect B-Series TI24X has the capability to register negative temperature settings. To change the temperature device poll time using the CLI. 34 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 45
    in all VLANs, enter the following command at the Privileged EXEC level of the CLI. PowerConnect# clear mac-address 000d.cb80.00d0 Syntax: clear mac-address | ethernet MAC addresses for a specified VLAN. Dell PowerConnect B-Series TI24X Hardware Installation Guide 35 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 46
    4 Removing MAC address entries 36 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 47
    schedule This chapter provides instructions for maintaining the PowerConnect B-Series TI24X hardware. DANGER The procedures in this manual are for qualified service personnel. The PowerConnect B-Series TI24X switch hardware components require minimal maintenance. Dell recommends that you clean
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 48
    also called a Small Form-factor Pluggable Plus) or an SFP from a port while the PowerConnect B-Series TI24X is powered on and running. Before removing a fiber optic module, you will need an or in an anti-static bag. 38 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 49
    optic connectors To avoid problems with the connection PowerConnect B-Series TI24X is powered on and running (if two power supplies are installed). The power supplies are located in slots at the rear of the PowerConnect B-Series TI24X . Dell PowerConnect B-Series TI24X Hardware Installation Guide
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 50
    sure which Power supply has failed or you not applid AC Voltage, enter the following command at any CLI command prompt: PowerConnect# show chassis Power supply 1 (NA - NA deg-C Speed 3: 3590 deg-C (shutdown) 40 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 51
    power supply Removing an AC power supply Follow the steps to remove an AC power supply. 1. Unplug the PDU power cords (C13-C14) from the power source. 2. Disconnect the PDU power cords (C13-C14) from the power supply. Dell PowerConnect B-Series TI24X Hardware Installation Guide 41 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 52
    until it is removed from the device. FIGURE 16 Removing the power supply 6. Place the power supply in an anti-static bag for storage. 42 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 53
    Replacing a power supply 5 Installing an AC power supply NOTE If the empty power supply bay With the other hand, support the underside of the power supply, and insert the power supply into the empty power supply slot. Dell PowerConnect B-Series TI24X Hardware Installation Guide 43 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 54
    -side up when the power connector is on the left and the fan vent is on the right. FIGURE 19 Installing the power supply 44 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 55
    after removing it from the device, otherwise the device will overheat. The fan tray is located in a slot at the rear of the PowerConnect B-Series TI24X . This section provides information about the following topics: Dell PowerConnect B-Series TI24X Hardware Installation Guide 45 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 56
    . NOTE If the device is connected with two Power supplies, you need to disconnect both the PDU power cords (C13-C14) from the device. 46 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 57
    power cords (C13-C14) to the power supply (refer to "Powering on the system" on page 18). 6. Verify that the system is working properly as instructed in "Verifying proper operation" on page 19. Dell PowerConnect B-Series TI24X Hardware Installation Guide 47 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 58
    5 Replacing the fan tray 48 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 59
    • "Key features" • "Physical dimensions and weight" • "Environmental considerations" • "Power supply consumption" • "Input connector and plug" • "Regulatory compliance" • "Safety warnings" • "Electrical specifications" Dell PowerConnect B-Series TI24X Hardware Installation Guide 49 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 60
    Environmental considerations For optimal performance, operate or store your Dell PowerConnect B-Series TI24X device in compliance with the following environmental conditions. Operating device as shown in Figure 25. 50 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 61
    Immunity standards, and safety agency approvals for PowerConnect B-Series TI24X switches. TABLE 9 Device regulatory compliance Description Products - Part 2 IEC 60950-1, 2nd Edition UL 60950-1, 2nd Edition Dell PowerConnect B-Series TI24X Hardware Installation Guide 51 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 62
    after AC loss >20ms 300 watts Mean Time between Failure Table 11 lists the Mean Time between Failure (MTBF) for the PowerConnect B-Series TI24X. The the PowerConnect B-Series TI24X and a PC or terminal are shown in Figure 27. 52 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 63
    + 4 CMT 5 CMT 6 TD- 7 CMT 8 CMT Cable specifications Table 12 lists the cable specifications for the cables used with the Gigabit, and 10-Gigabit Ethernet ports. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 64
    For network-specific recommendations, consult your local PowerConnect B-Series TI24X devices reseller or system engineer. TABLE 12 2 - 33 2 - 66 2 - 82 2 - 300 NOTE SMF = Single Mode Fiber, MMF = Multi-Mode Fiber. 54 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 65
    a power source. All power supplies are auto-sensing and auto-switching. Key features Refer to "Power supplies" on page 6 for the key features of the PowerConnect B-Series TI24X power supplies. Dell PowerConnect B-Series TI24X Hardware Installation Guide 55 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 66
    and weight TABLE 13 Physical dimensions and weight of power supplies Power Supply Dimensions Weight AC 4.06 cm (1.6 in.) (H) x 10.67 cm (2.84 lbs) (4.2 in.) condensing 4545.45 meter (15,000 feet) maximum 56 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 67
    Standard IEC 320 C14 type: UL/cUL 15A/250V, VDE 10A/250V Orientation: Ground pin up. Figure 29 shows the power plug and connector for AC power supplies. FIGURE 29 AC PDU power cords (C13-C14) plug and input connector Dell PowerConnect B-Series TI24X Hardware Installation Guide 57 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 68
    the safety warnings shown in Table 18. CAUTION No operator serviceable parts inside. Refer servicing to qualified personnel. TABLE 18 Safety warning labels on power örderlich. Wartung nur durch qualifiziertes Personal. 58 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 69
    specifications Description Ranges AC Input Specifications Input PowerConnect B-Series TI24X devices. Installing the power supply in a device other than the PowerConnect B-Series TI24X will cause extensive damage to your equipment. Dell PowerConnect B-Series TI24X Hardware Installation Guide
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 70
    A Power supply specifications 60 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 71
    -1 Safety of Laser Products-Part1: Equipment Classification, Requirements and User's Guide • EN 60825-2 Safety of Laser Products-Part2: Safety of Optical frequency magnetic field • EN 61000-4-11 Voltage dips and sags Dell PowerConnect B-Series TI24X Hardware Installation Guide 61 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 72
    and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this When such trouble occurs, the user may be required to take corrective actions. 62 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 73
    EMC registration for office use (Class A), and may be used in places other than home. Sellers and/or users need to take note of this. Dell PowerConnect B-Series TI24X Hardware Installation Guide 63 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 74
    B Regulatory statements China RoHS Restriction on the use of certain hazardous substances in electrical and electronic equipment. 64 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 75
    que pueda dañar el equipo. Las siguientes son precauciones utilizadas en este manual. . CAUTION VORSICHT MISE EN GARDE PRECAUCIÓN Do not install the device in corriente en sí no deberá conectado a la corriente). Dell PowerConnect B-Series TI24X Hardware Installation Guide 65 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 76
    y posterior del instrumento no esté restringido. Use a separate branch circuit for each AC PDU power cords (C13-C14), which provides redundancy in case one of the circuits de los conectores de corriente de entrada. 66 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 77
    bloc d'alimentation à l'envers. Verifique que el suministro de energía esté bien insertado en la ranura. No inserte nunca el suministro de energía en posición invertida. Dell PowerConnect B-Series TI24X Hardware Installation Guide 67 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 78
    used batteries according to the manufacturer's instructions. Explosionsgefahr bei unsachgemäßem Austausch der es par le personnel de service qualifié uniquement. Los procedimientos de este manual se han hecho para 1. 68 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 79
    oder der Schrank nicht wackeln oder umfallen kann. Vérifiez que le bâti ou le support abritant le dispositif est bien fixé afin qu'il ne devienne pas instable ou qu' instrumento para conectarlo a la fuente de corriente. Dell PowerConnect B-Series TI24X Hardware Installation Guide 69 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 80
    can be removed and replaced while the chassis is powered on and running. However, Dell recommends that you disconnect the power supply from the wall outlet before removing and u otras piezas podrían resultar dañadas. 70 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 81
    à grande vitesse. Procure no insertar los dedos accidentalmente en la bandeja del ventilador cuando esté desmontando el chasis. El ventilador podría estar girando a gran velocidad. Dell PowerConnect B-Series TI24X Hardware Installation Guide 71 53-1002265-01
  • Dell PowerConnect B-TI24x | Hardware Installation Guide - Page 82
    C Danger 72 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

53-1002265-01
18 March 2011
Dell PowerConnect B-
Series TI24X
Hardware Installation Guide