Dell PowerEdge R820 Technical Guide

Dell PowerEdge R820 Manual

Dell PowerEdge R820 manual content summary:

  • Dell PowerEdge R820 | Technical Guide - Page 1
    PowerEdge T110 II Technical Guide Ideal for collaboration, file sharing, and data protection, the T110 II is an ideal first server for small businesses.
  • Dell PowerEdge R820 | Technical Guide - Page 2
    Windows Server, SQL Server, Dell Inc. All rights reserved. Reproduction or translation of any part of this work beyond that permitted by U.S. copyright laws without the written permission of Dell Inc. is unlawful and strictly forbidden. December 2012 | Version 3.0 PowerEdge T110 II Technical Guide
  • Dell PowerEdge R820 | Technical Guide - Page 3
    Environmental Specifications 19 5.5 Maximum Input Amps 20 5.6 Thermal...20 5.7 Acoustics 20 6 Processors ...23 6.1 Overview 23 6.2 Processor Features 23 6.3 Supported Processors 23 6.4 Processor Configurations 24 6.5 Processor Installation 24 7 Memory ...25 PowerEdge T110 II Technical Guide
  • Dell PowerEdge R820 | Technical Guide - Page 4
    31 9.2.1 Power Management 31 10 Embedded NICs/LAN on Motherboard (LOM 33 10.1 Overview 33 10.2 NICs ...33 11 PCI Slots ...34 11.1 Overview 34 11.2 Quantities and Priorities 34 11.3 PCI Card Dimensions 34 12 Storage...35 12.1 Overview 35 12.2 Hard Drives 35 12.3 RAID Configurations 35 12
  • Dell PowerEdge R820 | Technical Guide - Page 5
    for Maximum Operating Temperature at Given Altitude 19 Table 6. Shock and Vibration Specifications 20 Table 7. Acoustical Specifications 21 Table 8. Supported Processors 23 Table 9. Supported Memory Configurations 26 Table 10. Power Management Features 31 Table 11. Supported Hard Drives 35
  • Dell PowerEdge R820 | Technical Guide - Page 6
    , preventing downtime in the event of a hard drive failure.  Protect your files with the Microsoft Windows Small Business Server 2011 standard backup features that let you restore files and recover data, including automatic backups on PowerEdge servers. PowerEdge T110 II Technical Guide 6
  • Dell PowerEdge R820 | Technical Guide - Page 7
    Dell 1.5 Business Friendly Easy to install, tailorable to your specific requirements and offering room for growth, the PowerEdge T110 II is the ideal server for small businesses and for remote offices of larger organizations.  Get the processing power your business demands with options from the
  • Dell PowerEdge R820 | Technical Guide - Page 8
    Hot-plug hard drives Redundant power Quad-pack LED or LCD diagnostic with hot-plug hard drive chassis Baseboard Management Controller (BMC), IPMI 2.0 compliant, Full Dell OpenManage™ suite Optional: iDRAC6 Express, iDRAC6 Enterprise, vFlash media I/O Slots NIC/LOM USB Power Supplies Fans 1 PCIe
  • Dell PowerEdge R820 | Technical Guide - Page 9
    (up to 25%) over previous generation  Twice the memory footprint at 32GB  Direct Media Interface (DMI) Gen 2  Support for up to four 3.5‖ SAS, nearline SAS, or SATA drives; support for up to six 2.5‖ SAS or SSD hard drives 2.2 Processor Features The Intel Xeon processor E3-1200 product
  • Dell PowerEdge R820 | Technical Guide - Page 10
    drives or Up to six 2.5‖ cabled SATA SSD or SAS drives Maximum Internal Storage1 Up to 12TB Hard Drives 3.5‖ SAS (15K), nearline SAS (7.2K), SATA (7.2K, 5.4K) 2.5‖ SATA SSD, SAS (10K) Embedded LOM/ NIC Integrated Broadcom® BCM5722 Gigabit Ethernet Controller PowerEdge T110 II Technical Guide
  • Dell PowerEdge R820 | Technical Guide - Page 11
    power supply (305W) Availability Video Quad-pack LED diagnostics, ECC memory, add-in RAID, TPM/TCM Matrox® G200eW with 8MB memory Remote Management N/A Systems Management Dell™ OpenManage™ featuring Dell Management Console (DMC) BMC, IPMI 2.0 compliant Unified Server Configurator Operating
  • Dell PowerEdge R820 | Technical Guide - Page 12
    Dell 4 Mechanical 4.1 Chassis Description The PowerEdge T110 II is a tower chassis design that supports the following features:  Four 3.5‖ cabled hard drives or six 2.5‖ cabled hard drives  Single non-redundant power supply  Diagnostic LED panel 4.2 Dimensions and Weight *Note: Zb goes to the
  • Dell PowerEdge R820 | Technical Guide - Page 13
    the front-panel view of the PowerEdge T110 II. Figure 2. Front-Panel View See the Front-Panel Features and Indicators section in the About Your System chapter of the PowerEdge T110 II Systems Owner's Manual on Support.Dell.com for more information on features. PowerEdge T110 II Technical Guide 13
  • Dell PowerEdge R820 | Technical Guide - Page 14
    the back-panel view of the PowerEdge T110 II. Figure 3. Back-Panel View See the Back-Panel Features and Indicators section in the About Your System chapter of the PowerEdge T110 II Systems Owner's Manual on Support.Dell.com for more information on features. PowerEdge T110 II Technical Guide 14
  • Dell PowerEdge R820 | Technical Guide - Page 15
    Systems Owner's Manual on Support.Dell.com for more information. 4.8 Rails and Cable Management The PowerEdge T110 II is not a rackable system and does not have a rack kit. However, the T110 II can be stored in a rack using a third-party rack tray. 4.9 Fans There is one cabled system fan located at
  • Dell PowerEdge R820 | Technical Guide - Page 16
    Setup. This mode includes the option to lock out the power or set up a system password. For more information, see System and Setup Password Features section in the About Your System chapter in the PowerEdge T110 II Systems Owner's Manual on Support.Dell.com. PowerEdge T110 II Technical Guide 16
  • Dell PowerEdge R820 | Technical Guide - Page 17
    used as SEL (system event log) especially to be used by the baseboard management controller (BMC). 4.15 User Accessible Jumpers, Sockets, and Connectors See the Jumpers and Connectors chapter in the PowerEdge T110 II Hardware Owner's Manual on Support.Dell.com. PowerEdge T110 II Technical Guide 17
  • Dell PowerEdge R820 | Technical Guide - Page 18
    Dell 5 Power, Thermal, Acoustic 5.1 Power Supplies The base PowerEdge T110 II system includes a single 305W power supply. This unit provides power to the planar, the internal hard drive bays, and the two 5.25‖ internal drive bays. Power is soft-switched, allowing power cycling using a switch on the
  • Dell PowerEdge R820 | Technical Guide - Page 19
    Dell 5.4 Environmental Specifications Table 4 summarizes the environmental specifications for the PowerEdge T110 II. Table 4. Environmental Specifications Specification Operating Requirements Non-Operating Requirements Temperature Ranges (For altitude ≤ 900m or 2952.75ft) Temperature Ranges (
  • Dell PowerEdge R820 | Technical Guide - Page 20
    from sound power level and sound pressure level in that it describes how humans respond to annoyances in sound, like whistles and hums. One of the sound quality metrics in the Dell specification is prominence ratio of a tone, which is listed in Table 7. PowerEdge T110 II Technical Guide 20
  • Dell PowerEdge R820 | Technical Guide - Page 21
    (hence noise levels) ramp up during the boot process to add a layer of protection for component cooling (in the case that the system does not boot properly). Table 7. Acoustical Specifications Minimum Configuration @ 23°C Ambient Processor Hard Drives Power Supply Tape Drives PCI Cards RAID
  • Dell PowerEdge R820 | Technical Guide - Page 22
    and D.11 of ECMA-74 11th ed. (2010) are followed to determine if discrete tones are prominent. The system is placed in a rack with its bottom at 75-cm from the floor. The acoustic transducer is at front bystander position, ref ISO7779 3rd (2010), Section 8.6.2. PowerEdge T110 II Technical Guide 22
  • Dell PowerEdge R820 | Technical Guide - Page 23
    quad-core  Power Aware Interrupt routing for power saving  PCIe 3.0 graphics and I/O  Integrated memory channel o 2 channels DDR3-1600 o 2 DIMMs per channel 6.3 Supported Processors Processors supported on the T110 II are listed in Table 6. For the most up-to-date listings, see Dell.com. Model
  • Dell PowerEdge R820 | Technical Guide - Page 24
    is embedded in the processor. 6.5 Processor Installation Refer to the Processors section in the Installing System Components chapter of the Dell PowerEdge T110 II Systems Owner's Manual on Support.Dell.com for processor installation and removal instructions. PowerEdge T110 II Technical Guide 24
  • Dell PowerEdge R820 | Technical Guide - Page 25
    not supported. 7.6 Mirroring Memory mirroring is not supported. 7.7 RAID Memory RAID is not supported. 7.8 Supported Configurations Supported memory configurations for the T110 II are listed in Table 9. For the latest information on memory options, visit Dell.com. PowerEdge T110 II Technical Guide
  • Dell PowerEdge R820 | Technical Guide - Page 26
    Dell Table 9. Supported Memory Configurations System Capacity (GB) DIMM Capacity (GB) DIMM Quantity DIMM Type 2 1 2 UDIMM 4 1 4 UDIMM 1 1 1 UDIMM 2 2 x8 1.5 2 x8 1.5 1 x8 1.5 2 X8 1.5 1 x8 1.5 2 x8 1.5 2 X8 1.5 2 X8 1.5 PowerEdge T110 II Technical Guide 26
  • Dell PowerEdge R820 | Technical Guide - Page 27
    (LPC) bridge function of the chipset resides in PCI Device 31: Function 0. In addition to the LPC bridge interface function, D31:F0 contains other functional units including DMA, interrupt controllers, timers, power management, system management, GPIO, and RTC. PowerEdge T110 II Technical Guide 27
  • Dell PowerEdge R820 | Technical Guide - Page 28
    to read and write accesses. This prevents unauthorized reading of passwords or other system security information. The RTC also supports a date alarm that allows for scheduling a wake up event up to 30 days in advance, rather than only 24 hours in advance. PowerEdge T110 II Technical Guide 28
  • Dell PowerEdge R820 | Technical Guide - Page 29
    -Disk). A hardware-based thermal management circuit permits software-independent entrance to low-power states. The chipset contains full support for the Advanced Configuration and Power Interface (ACPI) Specification, Revision 3.0a. 8.15 System Management Features The C200 series chipset integrates
  • Dell PowerEdge R820 | Technical Guide - Page 30
    Dell 8.17 Intel Virtualization Technology for Directed I/O The chipset provides hardware support for implementation of Intel Virtualization Technology with Directed I/O (Intel VT-d). Intel VT-d Technology consists of technology components that support memory. PowerEdge T110 II Technical Guide 30
  • Dell PowerEdge R820 | Technical Guide - Page 31
    Dell 9 BIOS 9.1 Overview The PowerEdge T110 II BIOS supports ACPI and power management features. 9.2 Supported ACPI States The PowerEdge T110 II BIOS is compliant with ACPI version 2.0a. 9.2.1 Power Management Power management features come in two types: fixed or generic. Fixed features use bits
  • Dell PowerEdge R820 | Technical Guide - Page 32
    will work under Windows and an ACPI OS that understands C states. In addition to P, C, and T states, the BIOS will expose the Power Profiles to the OS. Each Power profile will have a specific settings and it will fine tune the processor and South Bridge. PowerEdge T110 II Technical Guide 32
  • Dell PowerEdge R820 | Technical Guide - Page 33
    PCIe Card with TOE  Broadcom NetXtreme II 5709 Dual Port Ethernet PCIe Card with TOE and iSCSI Offload  Intel® PRO/1000 PT Server Adapter  Intel Gigabit ET Dual Port Server Adapter For the latest information on NIC offerings for the T110 II, see Dell.com. PowerEdge T110 II Technical Guide 33
  • Dell PowerEdge R820 | Technical Guide - Page 34
    Owner's Manual on Support.Dell.com. 11.3 PCI Card Dimensions For information about PCIe slots and card dimensions, see the Expansion Cards section in the Installing System Components chapter in the Dell PowerEdge T110 II Systems Owner's Manual on Support.Dell.com. PowerEdge T110 II Technical Guide
  • Dell PowerEdge R820 | Technical Guide - Page 35
    Dell 12 Storage 12.1 Overview The PowerEdge T110 II supports up to four 3.5‖ internal hard drives or up to six 2.5‖ internal hard drives. The following drive configurations are supported:  4 x 3.5‖ cabled SATA from motherboard SATA connector  4 x 3.5‖ cabled SAS or SATA with add-on storage
  • Dell PowerEdge R820 | Technical Guide - Page 36
    are as follows:  Configurations 0 to 5 are for 3.5‖ hard drives only  Configurations 6 to 14 are for 2.5‖ or 3.5‖ hard drives 12.4 Storage Controllers T110 II supports software RAID (PERC S100, PERC S300) and hardware RAID (PERC H200) for internal storage. PowerEdge T110 II Technical Guide 36
  • Dell PowerEdge R820 | Technical Guide - Page 37
    the PowerEdge T110 II:  No optical drive configuration  DVD-ROM (SATA)  DVD+RW (SATA) 12.6 Tape Drives Internal and external tape drives and tape libraries are supported. For more information on supported tape drives and tape libraries, see Dell.com/Storage. PowerEdge T110 II Technical Guide 37
  • Dell PowerEdge R820 | Technical Guide - Page 38
    Dell 13 Video The PowerEdge T110 II includes a Matrox® G200eW with 8 MB memory integrated in Winbond® WPCM450 (BMC controller). Supported resolutions 132 bit color only supported at 60Hz for this resolution. 285Hz for KVM and 1600x1200 at 60Hz for video out. PowerEdge T110 II Technical Guide 38
  • Dell PowerEdge R820 | Technical Guide - Page 39
    Dell 14 Rack Information Dell does not provide rack support for the PowerEdge T110 II. However, the system can be placed in a rack enclosure using a 3rd party tray. PowerEdge T110 II Technical Guide 39
  • Dell PowerEdge R820 | Technical Guide - Page 40
    Dell 15 Operating Systems For detailed information, see the following:  Operating System Support Matrix for Dell PowerEdge Systems on Dell.com  Dell PowerEdge T110 II Systems Getting Started Guide on Support.Dell.com PowerEdge T110 II Technical Guide 40
  • Dell PowerEdge R820 | Technical Guide - Page 41
    available content: • Dell Systems Build and Update Utility (SBUU): Dell Systems Build and Update Utility assists in OS install and pre-OS hardware configuration and updates. • Server Update Utility (SUU): This DVD has an inventory tool for managing updates to firmware, BIOS, and drivers for either
  • Dell PowerEdge R820 | Technical Guide - Page 42
    Simplified Hardware Configuration Description Drivers and the installation utility are embedded on system, so no need to scour Dell.com. Integration with Dell support automatically directed to latest versions of the Unified Server Configurator, RAID, BIOS, NIC, and power supply. Ability to
  • Dell PowerEdge R820 | Technical Guide - Page 43
    Dell 17 Peripherals The PowerEdge T110 II supports the following USB devices:  DVD (bootable; requires two USB ports)  USB key (bootable)  Keyboard (only one USB keyboard is supported)  Mouse (only one USB mouse is supported) PowerEdge T110 II Technical Guide 43
  • Dell PowerEdge R820 | Technical Guide - Page 44
    based executable containing the firmware file and the loader. System loaded with arbitrary data in firmware memory would not operate. Software write protected Details 512 Bytes Battery-backed NVRAM No RTC and Configuration settings F2 Setup Menu during POST N/A PowerEdge T110 II Technical Guide 44
  • Dell PowerEdge R820 | Technical Guide - Page 45
    NV storage. May be used to securely storage of encryption keys. TCG TPM Specification defined command interface or Using TPM Enabled operating systems As defined by the TCG TPM Specification, protection of this NV memory area is configurable by the TPM owner. PowerEdge T110 II Technical Guide 45
  • Dell PowerEdge R820 | Technical Guide - Page 46
    arbitrary data in firmware memory would not operate. Software write protected To obtain optional component information, please refer to the Dell Statement of Volatility for the individual components. Please direct any questions to your Dell Marketing contact. PowerEdge T110 II Technical Guide 46
  • Dell PowerEdge R820 | Technical Guide - Page 47
    1. Regulatory Certifications Regulatory compliance certificates can be located at the following sites:  http://www.dell.com/content/topics/global.aspx/about_dell/values/regulatory_compliance NEMKO GOST KSA ICCP NRCS BSMI UKRTEST or UKRSERTCOMPUTER NRTL STZ PowerEdge T110 II Technical Guide 47
  • Dell PowerEdge R820 | Technical Guide - Page 48
    Dell B 3. Electromagnetic Compatibility The product has been certified and bears the Mark, as applicable, of the EMC authorities as 18. Table 18. Ergonomics, Acoustics and Hygienics Country/Region Belarus Germany Russia Authority or Mark BELLIS GS GOST PowerEdge T110 II Technical Guide 48
  • Dell PowerEdge R820 | Technical Guide - Page 49
    Dell Appendix C. Industry Standards The PowerEdge T110 II system conforms to the industry standards detailed in Table 19. Table 19. Industry Standards Standard ACPI Advance Configuration and Power Interface Specification, v2.0c Energy Star EPA Version 1.0 of the Computer Server specification
  • Dell PowerEdge R820 | Technical Guide - Page 50
    USB Universal Serial Bus Specification, Rev. 2.0 Windows Logo Windows Logo Program System and Device Requirements, v3.10 URL for Information and Specifications http://www.usb.org/developers/docs/ http://www.microsoft.com/whdc/winlogo/hwrequirements. mspx PowerEdge T110 II Technical Guide 50
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

PowerEdge T110 II
Technical Guide
Ideal for
collaboration, file
sharing, and data
protection, the
T110 II is an ideal
first server for
small businesses.