Dell PowerStore 3000X EMC PowerStore Power Down and Reboot Procedures Guide
Dell PowerStore 3000X Manual
View all Dell PowerStore 3000X manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell PowerStore 3000X manual content summary:
- Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 1
Dell EMC PowerStore Power Down and Reboot Procedures Guide 1.x August 2020 Rev. A02 - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 2
of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 3
X model node...8 Powering on procedures for PowerStore node...9 Power on a PowerStore T model node using a service script 9 Power on a PowerStore T model node by reseating the node 10 Power on a PowerStore X model node using a service script 10 Power on a PowerStore X model node by reseating the - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 4
to the PowerStore Documentation page at www.dell.com/ powerstoredocs. • Troubleshooting For information about products, software updates, licensing, and service, go to www.dell.com/support and locate the appropriate product support page. • Technical support For technical support and service requests - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 5
○ Ensure that you also record the Dell service tag numbers of all enclosures in your cluster. • A PowerStore X model appliance consists of two ESXi information about the service scripts, see the PowerStore Service Scripts Guide. • If both nodes in an appliance reboot in service mode, always return - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 6
up the relevant component in your cluster: Table 1. Power control procedures preview Component Node Action Power off PowerStore T model Use PowerStore Manager. Or Run a service script. PowerStore X model Use VMware vCenter server. Appliance Cluster Power on Reboot Power off Power on Power off - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 7
power off (power down) a PowerStore T model node using PowerStore Manager: NOTE: If you are unable to access PowerStore Manager, see Power off a PowerStore T model node using a service script on page 8. Steps 1. Disable support notifications as described in Disable support notifications on page 19 - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 8
to the peer node. About this task Use the following procedure to power off (power down) a PowerStore T model node using a service script: Steps 1. Disable support notifications as described in Disable support notifications on page 19. 2. Launch an SSH client, and connect to the appliance using the - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 9
. Review the Management IPs table to identify the management IP address associated with the appliance. • Service account credentials About this task Use the following procedure to power on (power up) a PowerStore T model node in scenarios such as: • You are remote and cannot reseat the node. • Node - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 10
the power cable. 3. Wait for the node to complete powering on. 4. Enable support notifications as described in Enable support notifications on page 19. Power on a PowerStore X model node using a service script Prerequisites Obtain the following information: • Address of the VMware vCenter server - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 11
as described in Enable support notifications on page 19. Rebooting procedures for a PowerStore node This section includes the following procedures: • Reboot a PowerStore T model node using PowerStore Manager on page 11 • Reboot a PowerStore T model node using a service script on page 12 - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 12
reboot peer to reboot the peer node. For more information, see the PowerStore Service Scripts Guide. 5. Enable support notifications as described in Enable support notifications on page 19. Reboot a PowerStore X model node Prerequisites Obtain the following information: • Address of the VMware - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 13
VM have returned to normal operation. 10. Enable support notifications as described in Enable support notifications on page 19. Powering off procedures for PowerStore appliances This section includes the following procedures: • Power off a PowerStore T model appliance on page 13 • Power off - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 14
○ Associated vCenter server account credentials ○ Service tags of the appliance and, if applicable, the associated expansion enclosures About this task Use the following procedure to power off (power down) a PowerStore X model appliance: Steps 1. Disable support notifications as described in Disable - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 15
as described in Enable support notifications on page 19. Power on a PowerStore X model appliance Prerequisites Obtain the following information: • Address of the VMware vCenter server associated with the appliance • Associated vCenter server account credentials • Service tags of the appliance - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 16
on the cluster in a specific order. You can also find these instructions on www.dell.com/powerstoredocs. • Obtain the following information: ○ Management IP address of the cluster ○ Service account credentials ○ Site ID ○ Service tags of the appliances, and if applicable, the associated expansion - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 17
the information you require to power on the cluster in a specific order. You can also find these instructions on www.dell.com/powerstoredocs. • Obtain the following information: ○ Site ID ○ Service tags of the appliances, and if applicable, the associated expansion enclosures ○ Address of the VMware - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 18
as described in Enable support notifications on page 19. Power on a PowerStore X model cluster Prerequisites Obtain the following information: • Address of the VMware vCenter server associated with the appliance. • Associated vCenter server account credentials • Service tags of the appliance - Dell PowerStore 3000X | EMC PowerStore Power Down and Reboot Procedures Guide - Page 19
time when the system will resume sending support notifications. Enable support notifications Enable support notifications when you have finished servicing an appliance. Steps 1. In PowerStore Manager, go to Settings > Support > Disable Support Notifications. 2. Click the checkbox for the appliance
Dell EMC PowerStore
Power Down and Reboot Procedures Guide
1.x
August 2020
Rev. A02