and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2016 - 2019 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 3
Contents 1 About this guide...5 Related documents...5 2 The S4048T-ON System...6 Introduction...6 System status...7 LED display...7 LED behavior...8 Luggage tag...11 Prerequisites...11 S4048T-ON configurations...12 3 Site preparations...13 Site selection...13 Cabinet placement...14 Rack mounting... - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 4
Grub bootloader exampleONIE example...27 ONIE service discovery...28 6 Power supplies...30 Components...30 AC power supply installation...31 AC power and Compliance Agency Certifications 42 Electromagnetic Compatibility ...43 Product Recycling and Disposal...43 10 Dell EMC support...45 4 Contents - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 5
the S4048T-ON System • Dell Networking Configuration Guide for the S4048T-ON System • Dell Networking Command Line Reference Guide for the S4048T-ON System • Dell Open Networking Hardware Diagnostic Guide NOTE: For the most recent documentation, visit Dell EMC support: www.dell.com/support About - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 6
Dell EMC S4048T-ON system: Topics: • Introduction • System status • LED display • Luggage tag • Prerequisites • S4048T-ON configurations Introduction The S4048T The S4048T-ON offers the following features: • 48 fixed 10GBase-T ports supporting 1G/10G speeds • Six fixed QSFP+ ports supporting either - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 7
PSU2 5 10/100/1000BaseT Ethernet management port System status You can view system status information using the light emitting diodes (LEDs). LED display The S4048T-ON includes LED displays on both the I/O side and PSU side of the chassis. For LED information, see your third-party operating software - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 8
Fan status LED 7 Locator LED 8 QSFP+ LED-top row port 9 Stack ID number 10 QSFP+ LED-bottom row port Table 1. S4048T-ON I/O-side LED behavior LED 10 GBT Master System 8 The S4048T-ON System Description • Off-no link • Solid green-link at 10G speed • Blinking green-port activity at 10G speed • Solid - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 9
-port locator function Stack ID Number Displays the stack unit number of the switch Displays 1 by default if switch is not part of a stack Figure 5. S4048T-ON PSU-side LEDs 1 Fan LED The - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 10
2 Management port link LED 3 PSU LED 4 Management port act LED Table 2. S4048T-ON PSU-side LED behavior LED Fan LED Management port Link LED Management port Activity LED PSU LED to PSU/failure • Solid Green-PSU is operating normally • Blinking Green-PSU is turned off 10 The S4048T-ON System - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 11
S4048T-ON luggage tag 1 Service tag 3 MAC address Prerequisites 2 PPID 4 Express service code The following is a list of system components: NOTE: For more information, see Site Preparations and S4048T-ON Installation. • S4048T -Dell EMC recommends NOALOX 4 or equivalent The S4048T-ON System 11 - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 12
-ON system in several different configurations. Optional modules and optics are available to order separately. You can order the following supported hardware components: • S4048T-ON AC or DC Normal Airflow: 48-port 10GBase-T ports with six QSFP+ 40 G ports, two AC power supply units and four fan - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 13
components Site selection Install Dell EMC equipment in restricted access areas. A restricted access area is one in which service personnel can only gain guide before installing and powering up the system. WARNING: The following information is a condensed reference. Read the safety instructions - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 14
rack is grounded. Ground the equipment rack to the same ground point the power service in your area uses. The ground path must be permanent. System ground Dell EMC recommends you ground your system. Use the S4048T-ON in a common bond network (CBN). Connect the grounding cable as described in Ground - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 15
system has stock keeping units (SKUs) that support the following configurations: • AC or DC falls to 127.4°F (53°C). The S4048T-ON never intentionally turns off the Always disconnect the power cable before you service the power supply slots. CAUTION: Use components immediately, Dell EMC recommends - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 16
equipment building system (NEBS) compliant, you must follow the instructions detailed in this chapter. To be NEBs compliant, orient or at 100-240 VAC at a maximum current level of 7.1A. NOTE: The S4048T-ON is Earthquake Z4-compliant when you attach the ReadyRails to the frame using threaded hardware - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 17
the S4048T-ON system, Dell EMC recommends completing the installation procedures in the order presented in this guide. Always handle the S4048T- /region-specific power cords • Getting Started Guide • Safety and Regulatory Information • Warranty and Support Information Unpack 1 Place the container on - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 18
install the system in a rack, install the ground (GND) lug and bracket assembly with a ground wire attached. Dell EMC supplies a kit with the following: • One 2-hole UL-certified GND lug • L-bracket • Two flat two flat head screws, then attach the GND lug to the L-bracket. 18 S4048T-ON installation - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 19
Figure 8. Screws, GND lug, and L-bracket assembly a 1-Flat head screws b 2-GND lug c 3-Attached ground wire 3 Attach the assembly to the S4048T-ON chassis: a Apply the thread-locker compound to the two pan head screws. b Attach the GND lug and bracket assembly to the two-hole chassis - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 20
Figure 9. S4048T-ON PSU-side ground a 1-Pan head screws b 2-L-bracket CAUTION: Take care not to damage the attached ground wire as you proceed to if you use this method. 1 Face the ReadyRails flange ears outward, place one rail between the left and right vertical posts. 20 S4048T-ON installation - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 21
the vertical post and secure the plunger bracket to the post flange with two user-supplied screws, item 3. 4 Repeat this procedure for the second rail. S4048T-ON installation 21 - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 22
bracket towards the post and secure it to the post flange with two user-supplied screws, item 2. 3 Repeat this procedure for the second rail. 22 S4048T-ON installation - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 23
future rack requirements. 2 Attach the front and rear flanges for each rail to the post flanges with two user-supplied screws at each end, item 2. S4048T-ON installation 23 - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 24
chassis members switch rails to the system, items 1 and 2. The following illustration, item 3, shows the detail for the front standoff with the locking tab. 24 S4048T-ON installation - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 25
and falling. NOTE: Do not the use the mounted Ready-Rails as a shelf or a workplace. Ground wire installation After you have installed the S4048T-ON switch in a rack, complete the installation of the ground wire. You previously installed the GND lug and bracket assembly, with ground wire attached - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 26
ports and six quad small form-factor pluggable plus (QSFP+) optical ports. For a list of supported optics, see the S4048T-ON Specification Sheet at www.dell.com/support/ or contact your Dell EMC Networking representative. CAUTION: ESD damage can occur if the components are mishandled. Always wear an - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 27
splitting a single 40G QSFP+ port into four 10G ports using one of the supported breakout cables. System power-up Supply power to the S4048T-ON after it is mounted in a rack or cabinet. Dell EMC recommends reinspecting your system before powering up. Verify the following: • The equipment is properly - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 28
ONIE Run Diagnostic package for S4048T-ON During initial setup, the system boots to ONIE Install. ONIE Install boots with ONIE Discovery to the console, ONIE:. To configure your system, see your third-party ONIE-compatible OS or Dell EMC OS documentation. ONIE service discovery ONIE attempts to - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 29
bytes 64 bytes from 10.11.8.12: seq=0 ttl=62 time=1.357 ms 64 bytes from 10.11.8.12: seq=1 ttl=62 time=0.577 ms ^C S4048T-ON installation 29 - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 30
6 Power supplies The S4048T-ON ships with two power supply units. The system supports AC or DC power supplies with two air- NOTE: If you use a single PSU, install a blank plate in the other PSU slot. Dell EMC recommends using PSU2 as the blank plate slot. NOTE: Connect the power supply to the - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 31
plate in the other PSU slot. If you are only using one power supply, Dell EMC recommends installing the power supply in the first slot, PSU1, and installing a in the second slot, PSU2. 1 Remove the PSU slot cover from the S4048T-ON system. 2 Remove the PSU from the electro-static bag. 3 Insert the - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 32
PSU into a slot as this action may damage the PSU or the S4048T- ON chassis. NOTE: If a PSU fails, you must replace the entire unit. There are no field serviceable components in the PSU. To request a hardware replacement, see Dell Support. NOTE: If you use a single PSU, install a blank plate in the - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 33
to the power supply modules, you can order and install fan modules separately. The system supports two airflow direction options. DO NOT mix airflow types in a chassis; you can use Components The following list the fan components: • S4048T-ON fan module • S4048T-ON fan module-reverse flow Fans 33 - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 34
1 PSU1 3 RS-232/RJ-45 serial console port 5 10/100/1000BaseT Ethernet management port Fan module installation 2 Fan modules 4 PSU2 The fan modules in the S4048T-ON are field replaceable. Module slot 1 is on the left side of the chassis, module slot 2 is in the middle of the chassis, and module - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 35
Fan air filter replacement Environmental factors can decrease the amount of time required between air filter replacements. Check the environmental factors regularly. An increase in temperature and/or particulate matter in the air might affect performance. CAUTION: Check the fan air filters at six- - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 36
-ON chassis. Figure 21. S4048T-ON PSU-side view 1 PSU1 3 RS-232/RJ-45 serial console port 5 10/100/1000BaseT Ethernet management port 2 Fan modules 4 PSU2 CAUTION: Ensure that any equipment attached to the serial port can support the required 115200 baud rate. NOTE: When connecting the RJ45 - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 37
the system. 4 Power on the system. 5 Install the necessary USB device drivers. Go to www.dell.com/support to download the drivers. For assistance, contact Dell EMC Technical Support. 6 Access the S4048T-ON by opening your terminal software emulation program. 7 Confirm that the terminal settings as - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 38
USB storage mount The USB storage supports the FAT file system. The USB storage does not automatically mount. To use USB storage, you must first mount the device. 1 Create a mount directory for - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 39
9 Specifications This chapter lists the S4048T-ON specifications. CAUTION: Operate the product at an ambient temperature equivalent type of battery. Dispose of the batteries according to the manufacturer's instructions. NOTE: For RoHS information, see Restricted Material Compliance. Topics: • - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 40
0A −48V/19.2A −60V/ 16.0A, with fan. 39.0+/−1.5V. 37.5+/−1.5V. The S4048T-ON complies with the following IEEE standards: • 802.3ab Gigabit Ethernet (1000BASE-T) • 802.3ae it is not installed and used in accordance to the instructions, it may cause harmful interference to radio communications. - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 41
is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. WARNING: Use the AC power cords with Dell Networking equipment only. Do not use Dell EMC AC power cords with any unauthorized hardware. Specifications 41 - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 42
• CSA 60950-1-03, 2nd Edition • EN 60950-1, 2nd Edition • EN 60825-1, 1st Edition • EN 60825-1 Safety of Laser Products - Part 1: Equipment Classification Requirements and User's Guide 42 Specifications - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 43
of information technology (IT) equipment to responsibly recycle their equipment when it is no longer needed. Dell EMC offers a variety of product return programs and services in several countries to assist equipment owners in recycling their IT products. Waste Electrical and Electronic Equipment - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 44
is important to minimize any potential effects of EEE on the environment and human health due to the potential presence of hazardous substances in EEE. Dell EMC products, which fall within the scope of the WEEE, are labeled with the crossed-out wheelie-bin symbol, as shown above, as required by - Dell PowerSwitch S4048T-ON | EMC S4048T-ON Installation Guide January 2019 - Page 45
page, click Technical Support. • To access S4048T documentation, go to www.dell.com/manuals/. • To search for drivers and downloads, go to www.dell.com/drivers/. • To participate in Dell EMC community blogs and forums, go to www.dell.com/community. To view the service tag or express service code on
Dell EMC S4048T-ON Installation Guide
January 2019