    Dell EMC S5000 Installation Guide 9.6(0.0)
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 2
    of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. NOTE: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2014 Dell Inc. All rights reserved. This product is protected
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 3
    Contents 1 About this Guide...5 Related Publications...5 2 Introduction...6 Product Description...6 3 Unpacking the Switch...7 Important Points Before You Continue...7 Hardware Installation Overview...8 4 Hardware Overview...9 I/O Panel...9 Utility Panel...10 Port Numbering Convention...
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 4
    of Compliance...38 Safety Standards and Compliance Agency Certifications 39 Electromagnetic Compatibility (EMC)...39 Product Recycling and Disposal...39 9 Technical Support...41 The iSupport Website...41 Accessing iSupport Services...41 Requesting a Hardware Replacement...41 Contacting Technical
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 5
    Guide This guide OS Configuration Guide for the Line Reference Guide for the S5000 guide before you install and power up this equipment. This equipment contains two power cords. Disconnect both power cords before servicing Guide for the S5000 Switch • Dell Networking OS Command Line Reference Guide
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 6
    about how to configure and monitor switch features, refer to the Dell Networking OS Configuration Guide for the S5000 Switch, which is available on the Dell Support website at www.dell.com/support Topics: • Product Description Product Description This switch is part of Dell EMC S5000 Series of
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 7
    or damaged, contact your Dell EMC representative or reseller for instructions. NOTE: Electrostatic discharge (ESD) damage can occur if (country/region specific) • Getting Started Guide • Safety and Regulatory Information • Warranty and Support Information • Software License Agreement 1. Place
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 8
    Figure 1. S5000 I/O and Utility Panels 1. I/O panel 2. Utility panel 3. Four 40GbE QSFP+ ports (each port ALSO supports 4 × 10GbE mode) Hardware Installation Overview To install the S5000, follow these steps: 1. Attach the mounting brackets. 2. Install the S5000 chassis into a 4-post rack or cabinet
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 9
    RS-232 console port with YOST RJ-45 pinout and a dedicated Ethernet service port for out-of-band (OOB) management functions. Topics: • I/O (supports Ethernet and Fibre Channel modules) 2. Slot 1 (supports only Ethernet modules) 3. Slot 2 (supports only Ethernet modules) 4. Slot 3 (supports only
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 10
    two PSUs installed and running), you can remove and replace one PSU while the other PSU is running without disrupting traffic. Fans The S5000 supports two fan trays with airflow directions from I/O to Utility or Utility to I/O. Do not mix I/O to Utility and Utility to I/O airflows in a single S5000
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 11
    I/ O panel. You can also use the 40GbE ports in 4 × 10GbE mode. The S5000 supports the following possible modules: • 12-Port Ethernet Module (1G/10G speeds) (slot 0, 1, 2, the Dell Networking OS Command Line Reference Guide and Dell Networking OS Configuration Guide for the S5000 Switch. As shown in
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 12
    • No activity • System beacon/locator • No alarm • Minor alarm • Critical alarm • No power • Normal operation • System is booting • System in card problem state • Switch in Stacking Master mode OR Switch in Standalone mode • Switch in Stacking Standby mode • Switch in Stacking Member mode • Normal
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 13
    • Link present and interface enabled • Port has activity • No activity • Module beacon/locator • Module is not powered up • Module is powered up • Problem detected with module Figure 8. QSFP+ Port LEDs 1. Port link/activity LED Table 4. 40GbE Port/Module LEDs Label Port link/activity LED LED Color
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 14
    Storing Components Site Selection Dell EMC equipment is intended for installation in restricted access areas. A restricted access area can only be accessed by service personnel by using a special tool, lock, key or other means of security and access is controlled by the authority responsible for the
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 15
    6 Installation Topics: • Before You Begin • Installing in a Rack or Cabinet • Attaching the Mounting Brackets • Rack Mounting Safety Considerations • Installing the S5000 Chassis into a 4-Post Rack or Cabinet • Rack Grounding • Important Points to Remember for Installing an Ethernet Module •
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 16
    • Switch is installed in an environment as free as possible from dust and foreign conductive material (such as metal flakes from construction activities). Cooling mechanisms, such as fans and blowers in the switch, can draw dust and other particles causing contaminant buildup inside the chassis,
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 17
    strips. • Do not mount the equipment with the Utility panel facing in the downward position. NOTE: These instructions are a condensed reference. Read the safety instructions in your Safety, Environmental, and Regulatory information booklet before you begin. NOTE: The illustrations in this document
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 18
    You must ground the equipment rack to the same ground point the power service uses in your area. The ground path must be permanent. Important Points A blue color release latch indicates that the Ethernet module does not support hot swapping during switch operations. Instead, you must power down the
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 19
    Figure 11. Part name and Port number on the Ethernet Module Handle 1. Part Name 2. Port Number Installing an Ethernet Module 1. Use the grab handle on the Ethernet module to slide it into the switch module slot. 2. Connect any network interface cables to the attached module. Installation 19
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 20
    is powered up, the system does not recognize the module. Online insertion of modules can result in a catastrophic failure. • The S5000 does not support the hot swapping of a Fibre Channel pluggable module during switch operations. Instead, you must power down the switch before removing and replacing
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 21
    Figure 13. Part name and Port number on the Fibre Channel Module Handle 1. Part Name 2. Port Number Installing a Fibre Channel Module 1. Use the grab handle on the Fibre Channel module to slide it into the switch module slot. 2. Connect any network interface cables to the attached module.
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 22
    Channel Module Replacing a Fibre-Channel Module NOTE: S5000 does not support the hot swapping of a Fibre-Channel pluggable module during switch the Dell Networking OS Command Line Reference Guide for the S5000 Switch and Dell Networking OS Configuration Guide for the S5000 Switch. NOTE: Although
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 23
    CAUTION: DO NOT mix airflow directions. The airflow directions are color coded. A red label indicates that hot air is expelled from the PSU and a blue label indicates that hot air is expelled from the I/O. Both power supplies must use the same airflow direction (I/O to Utility or Utility to I/O).
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 24
    CAUTION: Always disconnect the power cable before you service the power supply slots. CAUTION: Use the power . • The S5000 supports AC and DC power supplies with two air-flow directions (I/O Command Line Reference Guide for the S5000 Switch and Dell Networking OS Configuration Guide for the S5000
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 25
    connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that Dell EMC did not authorize is not covered by your warranty. 1. Strip the insulation from the end of the green/yellow wire
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 26
    Installing a DC Power Supply 1. Remove the PSU from the electro-static bag. 2. Use the grab handle to slide the PSU into the switch PSU slot (install the PSU-exposed PCB edge connector first). The PSU slot is keyed so that the PSU can be fully inserted in only one way. When you correctly install the
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 27
    powered-up as soon as the power cord is connected between the system and the power source. CAUTION: Always disconnect the power cable before you service the power supply slots. CAUTION: Use the power supply cord as the main disconnect device on the AC or DC system. Ensure that the socket
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 28
    Figure 20. Installing the Ferrite Bead for DC Power and Return Cables a. Ferrite Bead b. DC Power and Return Cables 3. Leave approximately 4 to 5 inches of the DC power and return cables end protruding from the ferrite. 4. Snap the ferrite bead shut. Securing Power Cables 1. Bend the system power
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 29
    fails, you must completely replace it. There are no field serviceable components in the PSU. 1. Disconnect the power cable from the chapters of the Dell Networking OS Command Line Reference Guide for the S5000 Switch and Dell Networking OS Configuration Guide for the S5000 Switch. CAUTION: DO NOT mix
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 30
    small vent holes above and below the ports. Splitting QSFP+ Ports to SFP+ Ports The S5000 supports splitting a single 40GbE QSFP+ port into four 10GbE SFP+ ports using one of the supported breakout cables. • Configure the system to recognize the port mode change. CONFIGURATION mode stack-unit unit
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 31
    : The S5000 system does not stack with other S-Series systems. NOTE: Stacking is not supported on 40GbE ports operating in 4x10GbE (quad) mode. NOTE: If you use three or powered down or up. Stacking ports are bidirectional. The S5000 supports stacking in either a ring or a daisy-chain topology. To
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 32
    Figure 24. Stacking Topology Connecting Two S5000 Systems To provide backup connectivity and increased data transfer between the systems, Dell EMC recommends inserting an additional cable between the two units, in a second stacking port. You can use any of the SFP+ or QSFP+ ports for stacking,
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 33
    Connecting Three S5000 Systems To provide backup connectivity and increased data transfer between the systems, Dell EMC recommends inserting an additional cable between the two units, in a second stacking port. CAUTION: The S5000 does not require special stacking cables. The cables used to connect
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 34
    Supplying Power and Powering Up the System Supply power to the S5000 system after the chassis is mounted in a rack or cabinet. NOTE: Installing and swapping of Fibre Channel or Ethernet modules must be done BEFORE power up. If you need to replace a module, power down the system before you replace it
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 35
    setting up a new set of switches in a stack, you should have no trouble forcing the identification of the management unit and unit IDs by methodically supplying power to the Stacking chapter in the Dell Networking OS Configuration Guide for the S5000 Switch and the Stacking Commands chapter in
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 36
    replaced. NOTE: Replace the battery only with same or equivalent type. Dispose of the batteries according to the manufacturer's instructions. Table 5. Chassis Physical Design Parameter Height Width Depth Chassis weight with factory-installed components Rack clearance required Specifications 1.71
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 37
    environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance to the instructions, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 38
    For Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. Korean Certification of Compliance Korean Package Label 38 Agency Compliance
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 39
    60825-1 Safety of Laser Products - Part 1: Equipment Classification Requirements and User's Guide • EN 60825-2 Safety of Laser Products - Part 2: Safety of Optical needed. Dell EMC offers various product return programs and services in several countries to assist equipment owners in recycling their
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 40
    must not dispose of end of life EEE as unsorted municipal waste, but use the collection framework available to customers for the return, Specifications | 47 recycling and recovery of WEEE. Customer participation is important to minimize any potential effects of EEE on the environment and human
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 41
    the troubleshooting steps taken. • Saved messages to a syslog server, if you use one. Contacting Technical Support Table 8. Technical Support How to Contact Dell EMC Tech Support Log in to iSupport at https://www.force10networks.com/ CSPortal20/Main/Login.aspx and select the Service Request
  • Dell PowerSwitch S5000 | EMC S5000 Installation Guide 9.60.0 - Page 42
    as a section in the output of the show tech-support command.) • Console captures showing the error messages • Console captures showing the troubleshooting steps taken • Saved messages to a syslog server, if you use one Log in to iSupport and select the Service Requestt tab to view all open cases and
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

Dell EMC S5000
Installation Guide 9.6(0.0)