Dell PowerSwitch S5000 Networking S5000 Getting Started Guide
Dell PowerSwitch S5000 Manual
View all Dell PowerSwitch S5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell PowerSwitch S5000 manual content summary:
- Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 1
Dell Networking S5000 Getting Started Guide - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 2
use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2014 Dell Inc. All rights reserved. This product is - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 3
, refer to the documents listed below: Table 1. S5000 Documents Information Documentation Hardware installation and power-up instructions Installing the S5000 Switch Software configuration FTOS Configuration Guide for the S5000 Switch Command line interface FTOS Command Line Reference - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 4
Guide for the S5000 Switch, which is available on the Dell Support website at http://www.dell.com/ support/manuals supports Data Center Bridging (ETS/PFC/DCBX), FCoE Transit (FIP Snooping), NPIV Proxy Gateway (NPG), FC Fabric services or reseller for instructions. WARNING: Electrostatic discharge - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 5
female cable • Two AC or DC power cords for AC or DC units (country/region specific) • Getting Started Guide • Safety and Regulatory Information • Warranty and Support Information • Software License Agreement 1. Place the container on a clean, flat surface and cut all straps securing the container - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 6
Hardware Installation Overview To install the S5000, follow these steps: 1. Attach the mounting brackets. 2. Install the S5000 chassis into a 4-post rack or cabinet. 3. Ground the rack. 4. Install the Ethernet and/or Unified Port modules (Unified Port module must be installed only in slot 0). 5. - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 7
RS-232 console port with YOST RJ-45 pinout and a dedicated Ethernet service port for out-of-band (OOB) management functions. I/O Panel All 0 (supports Ethernet and Unified Port modules) 3. Slot 2 (supports only Ethernet modules) 2. Slot 1 (supports only Ethernet modules) 4. Slot 3 (supports only - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 8
(two PSUs installed and running), you can remove and replace one PSU while the other PSU is running without disrupting traffic. Fans The S5000 supports two fan trays with airflow directions from I/O to Utility or Utility to I/O. Do not mix I/O to Utility and Utility to I/O airflows in a single S5000 - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 9
panel. You can also use the 40GbE ports in 4 × 10GbE mode. The S5000 supports the following possible modules: • 12-Port Ethernet Module (100MbE/1GbE/10GbE speeds, RJ-45 the Dell Networking OS Command Line Reference Guide and Dell Networking OS Configuration Guide for the S5000 Switch. As shown in - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 10
Figure 5. System LEDs (Utility Panel) (AC Power Supplies installed) 1. Locator beacon LED 3. System status LED 5. Seven-segment display to identify Stack ID 7. Fan status LED 2. Alarm LED 4. Master LED 6. PSU status LED NOTE: For AC PSUs, an illuminated translucent handle indicates the power - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 11
LED LED Color/Display • Amber solid • Green solid • Green blinking • Off • Green solid • Off • Green solid • Off Description • System in card problem state • Switch in Stacking Master mode OR Switch in Standalone mode • Switch in Stacking Standby mode • Switch in Stacking Member mode • Normal - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 12
Green solid • Yellow Description • Port has activity • No activity • Module beacon/locator • Module is not powered up • Module is powered up • Problem detected with module Description • No link or interface disabled • 10G link, interface enabled • 10G link activity • 1G/100M link, interface enabled - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 13
Figure 8. QSFP+ Port LEDs 1. Port link/activity LED Table 6. 40GbE Port/Module LEDs Label Port link/activity LED LED Color/Display • Off • Green solid • Green blinking Table 7. 10G Base-T Port LEDs Label Port link/activity LED LED Color/Display • Off • Green solid • Green blinking Description - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 14
4 Installation Before installing the switch, verify that you meet these guidelines: • Enough clearance to the front of the switch so you can read the LEDs. • AC/DC power cord reaches from the power outlet to the Utility-panel connector. • Switch is rack-mounted before you install the power supply - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 15
Attaching the Mounting Brackets The S5000 is shipped with mounting brackets (rack ears) and the required screws (eight screws) for rack or cabinet installation. The brackets are enclosed in a package with the chassis. 1. Take the brackets and screws out of their packaging. 2. Slide the mounting - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 16
. • Do not mount the equipment with the Utility panel facing in the downward position. WARNING: These instructions are a condensed reference. Read the safety instructions in your Safety, Environmental, and Regulatory information booklet before you begin. NOTE: The illustrations in this document - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 17
prepare your equipment rack, ensure that the rack is earth ground. You must ground the equipment rack to the same ground point the power service uses in your area. The ground path must be permanent. Important Points to Remember for Installing an Ethernet Module • Installing and swapping of Ethernet - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 18
. Instead, you must power down the switch before removing and replacing an Ethernet module. A red color release latch indicates that the Ethernet module supports hot swapping during switch operations. Figure 11. Part name and Port number on the Ethernet Module Handle 1 Part Name . 2 Port Number - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 19
is powered up, the system does not recognize the module. Online insertion of modules can result in a catastrophic failure. • The S5000 does not support the hot swapping of a Unified Port pluggable module during switch operations. Instead, you must power down the switch before removing and replacing - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 20
NOTE: The part name and port number of a Unified Port module are inscribed on the handle as shown below. Figure 13. Part name and Port number on the Unified Port Module Handle 1 Part Name . 2 Port Number . Installing a Unified Port Module 1. Use the grab handle on the Unified Port module to - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 21
the PSU or the S5000 chassis. • The S5000 supports AC and DC power supplies with two air-flow directions (I/O to Utility and Utility to I/O). the Dell Networking OS Command Line Reference Guide for the S5000 Switch and Dell Networking OS Configuration Guide for the S5000 Switch. WARNING: Although the - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 22
CAUTION: DO NOT mix airflow directions. The airflow directions are color coded. A red label indicates that hot air is expelled from the PSU and a blue label indicates that hot air is expelled from the I/O. Both power supplies must use the same airflow direction (I/O to Utility or Utility to I/O). - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 23
powered-up as soon as you connect the power cord between the system and the power source. CAUTION: Always disconnect the power cable before you service the power supply slots. CAUTION: Use the power supply cord as the main disconnect device on the AC system. Ensure that the socket-outlet is - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 24
action may damage the PSU or the S5000 chassis. • The S5000 supports AC and DC power supplies with two air-flow directions (I/O to Utility and Utility to I/O). The S5000 does chapters of the Dell Networking OS Command Line Reference Guide for the S5000 Switch and Dell Networking OS Configuration - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 25
WARNING: Although the switch can run on one PSU, Dell Networking highly recommends using two PSUs for full redundancy and proper cooling. If the switch needs to run with only one PSU for a time, be sure to cover the second PSU slot opening with a blank plate to avoid overheating. WARNING: The - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 26
Figure 18. Installing a DC Power Supply 1. Slot 0 (for DC PSU 0) 2. Release latch 3. Strip the insulation from the ends of the DC power wires, exposing approximately 13 mm (0.5 inch) of copper wire. WARNING: Reversing polarity when connecting DC power wires can permanently damage the power - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 27
powered-up as soon as the power cord is connected between the system and the power source. CAUTION: Always disconnect the power cable before you service the power supply slots. CAUTION: Use the power supply cord as the main disconnect device on the AC or DC system. Ensure that the socket - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 28
Figure 20. Installing the Ferrite Bead for DC Power and Return Cables 1. Ferrite Bead 2. DC Power and Return Cables 3. Leave approximately 4 to 5 inches of the DC power and return cables end protruding from the ferrite. 4. Snap the ferrite bead shut. Securing Power Cables 1. Bend the system - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 29
command. For more information, refer to the System Logs chapters of the Dell Networking OS Command Line Reference Guide for the S5000 Switch and Dell Networking OS Configuration Guide for the S5000 Switch. CAUTION: DO NOT mix airflow directions. The airflow directions are color coded. A red label - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 30
the SFP+ and QSFP+ Optics The S5000 has 48 small form-factor pluggable plus (SFP+) optical ports and four QSFP+ optical ports. For a list of supported optics, refer to the S5000 data sheet: http://www.dell.com/us/enterprise/p/ force10-s-series/pd. CAUTION: ESD damage can occur if the components are - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 31
splitting a single 40GbE QSFP+ port into four 10GbE SFP+ ports using one of the supported breakout cables. For a list of supported optics, refer to the S5000 data sheet: http://www.dell.com/us/enterprise/p/ force10-s-series/pd. • Configure the system to recognize the port mode change. - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 32
NOTE: For powering up an AC PSU, an AC power cable is included in the shipping container. You must order all other power cables separately. CAUTION: ESD damage can occur if the components are mishandled. Always wear an ESDpreventive wrist or heel ground strap when handling the S5000 and its - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 33
the console port. The terminal settings are the same for both access ports. The S5000 supports bare metal provisioning (BMP). For information about how to configure BMP, refer to FTOS Configuration Guide for the S5000 Switch. Software Configuration Overview To configure the S5000, follow these steps - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 34
c. 8 data bits d. 1 stop bit e. No flow control Figure 23. RS-232/RJ-45 Console Port Accessing the RJ-45 Console Port with a DB-9 Adapter You can connect to the console using an RJ-45 to RJ-45 rollover cable and an RJ-45 to DB-9 female DTE adapter to a terminal server (for example, a PC). The pin - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 35
the necessary USB device drivers (you will need an Internet connection). For assistance, contact Dell Networking Technical Support. 3. Connect the USB-A end of cable into an available USB port on the PC. 4. features and interfaces, refer to the FTOS Configuration Guide for the S5000 Switch. 35 - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 36
IP Settings You will need the following information from your network administrator: • Switch IP address • Subnet mask (IP netmask) • Default gateway (router) • Enable secret password • Enable password • Telnet password Configuring the Enable Password To access EXEC Privilege mode, use the enable - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 37
hostname name Navigate CLI modes The FTOS prompt changes to indicate the CLI mode. You must move linearly through the command modes, except for the end command which takes you directly to EXEC Privilege mode and the exit command which moves you up one command mode level. Default Configuration A - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 38
Configuring the Management Port IP Address To access the system remotely, assign IP addresses to the management ports. NOTE: Assign different IP addresses to each stack-unit's management port. 1. Enter INTERFACE mode for the Management port. CONFIGURATION mode interface ManagementEthernet slot/port - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 39
encryption-type specifies how you are inputting the password, is 0 by default, and is not required. - 0 is for inputting the password in clear text. - 7 is for inputting a password that is already encrypted using a Type 7 hash. Obtaining the encrypted password from the configuration of another Dell - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 40
3. Access the INTERFACE VLAN mode of the VLAN to which you want to assign the interface. CONFIGURATION mode interface vlan vlan-id 4. Configure an interface as untagged. This command is available only in VLAN interfaces. INTERFACE mode untagged interface Assigning an IP Address to a VLAN VLANs are a - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 41
incorrectly replaced. NOTE: Replace the battery only with same or equivalent type. Dispose of the batteries according to the manufacturer's instructions. Table 9. Chassis Physical Design Parameter Specifications Height 1.71 inches (43.5 mm) Width 17.4 inches (441 mm) Depth 28 inches (711 - Dell PowerSwitch S5000 | Networking S5000 Getting Started Guide - Page 42
42
Dell Networking S5000
Getting Started Guide