Dell PowerSwitch S6000 ON OpenSwitch OPX Administration Guide Release 2.1.0
Dell PowerSwitch S6000 ON Manual
View all Dell PowerSwitch S6000 ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell PowerSwitch S6000 ON manual content summary:
- Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 1
OpenSwitch OPX Administration Guide Release 2.1.0 - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 2
2017 - 7 Rev. A02 - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 3
Puppet open source...8 Nagios Open Source...11 2 Troubleshooting...13 Debug port interfaces...13 Layer 2 troubleshooting...13 Layer 3 troubleshooting...14 Log management...14 Manage CPS API objects show-transceivers...26 opx-show-version...27 opx-switch-log...27 4 Support resources...29 Contents 3 - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 4
after system boot up (see Run-time components in the OpenSwitch OPX Developers Guide for a list of processes). • ACL entries are installed to direct control the IP address of the Management interface is configured. By default, SSH service is enabled. The user name and password are both admin. $ ssh - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 5
.xml - default configuration of objects, such as mirroring, sFlow, and VLANs created during system boot up as part of the systemd service (file is stored in /etc/opx/dn_nas_default_init_config.xml) • dn_nas_fanout_init_config.xml - interfaces fanned out during system boot up (file is stored in - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 6
Linux firewall features. You can also set up rate limiting for incoming traffic to prevent denial of service attacks. Configure physical port See the OpenSwitch OPX Configuration Guide to configure physical port attributes. Create user accounts Use standard Linux commands to manage user accounts - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 7
: /system.slice/snmpd.service └─3416 /usr/sbin/snmpd -Lsd -Lf /dev/null -u snmp -g snmp -I -smux... Monitoring OpenSwitch OPX supports network monitoring features to . See the OpenSwitch OPX Installation Guide for complete information on using ONIE to upgrade the software image. Administration - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 8
Write Protect is off sd 6:0:0:0: [sdb] Write cache: disabled, read cache: enabled, doesn't support DPO or FUA sd 6:0:0:0: [sdb] Attached SCSI removable disk up. Info: Trying DHCPv4 on interface systems running the software by following the instructions at www.puppetlabs.com. 8 Administration - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 9
the Puppet agent on both systems by following the instructions at www.puppetlabs.com. 3 Verify if the daemons': owner => quagga, group => quagga, source => 'puppet:///modules/ibgp/quagga_daemons', notify => Service['quagga'] } file { '/etc/quagga/Quagga.conf': owner => root, group => quaggavty, mode - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 10
Sample configuration-Quagga configuration file ! This file is managed by Puppet hostname zebra log file /var/log/quagga/zebra.log hostname ospfd log file /var/log/quagga/ospfd.log log timestamp precision 6 hostname bgpd log file /var/log/quagga/bgpd.log ! password cn321 enable password - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 11
bit mask # (i.e. 192.168.1.0/24) are also supported. Hostname wildcards are not currently supported. # Note: The daemon only does rudimentary checking of is the daemon running on the Nagios server). A plugin monitors the services and resources on an OpenSwitch OPX system and returns the results to - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 12
.cfg file on the Nagios server to configure services to be monitored on the system. define service{ use host_name service_description check_command } generic-service Dell_OPX Current Processes check_nrpe!check_total_procs define service{ use host_name service_description check_command } generic - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 13
, physical ports map to Linux network interfaces. See Physical ports in the OpenSwitch OPX Configuration Guide for information about the naming convention of Linux network interfaces. Troubleshoot interfaces • If Linux network interfaces are not created: • Check that the NAS process is running - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 14
contents of NPU log files in Layer 3. Verify routing-related tables • ip route show • arp -a IPv6 debugging • ip -6 neighbor show • ip -6 route show Troubleshoot routing issues in the NPU • opx-switch-shell "l3 defip show" • opx-switch-shell "l3 l3table show" • opx-switch-shell "l3 egress show" IPv6 - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 15
[module_name] [level_name] where: • module_name specifies a SAI module: • WRED • FDB • ROUTE • VLAN • HOST_INTERFACE • ACL • MIRROR • QOS_QUEUE • SCHEDULER_GROUP • PORT • VIRTUAL_ROUTER • NEXT_HOP_GROUP • SWITCH • POLICER • NEIGHBOR • UNSPECIFIED • SAMPLEPACKET • QOS_MAPS Troubleshooting 15 - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 16
the command as a CPS API key in A.B.C.D format. See CPS keys in the OpenSwitch OPX Developers Guide for information about how to build a key, and the appropriate header files for actual key values. cps_trace_events generated by PAS cps_trace_events.py observed base-pas/entity 16 Troubleshooting - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 17
by default) • opx-show-stats clear [iface_name | vlan_ifindex] - delete statistics for all or specified port or VLAN interfaces See Statistics in the OpenSwitch OPX Configuration Guide for more information about the opx-show-stats command. Troubleshooting 17 - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 18
3 Linux management Topics: • opx-config-fanout • opx-chassis-beacon • opx-config-switch • opx-ethtool • opx_logging_cli • opx-show-alms • opx-show-env • opx-show-packages • opx-show-stats • opx-show-system-status • opx-show-transceivers • opx-show-version • opx-switch-log opx-config-fanout Enables - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 19
opx-chassis-beacon Toggles the port LED of an interface to easily identify each time a beacon is sent to check for pending packets on the interface. Syntax opx-chassis-beacon [on | off] Parameters on Enable the beacon LED. off Disable the beacon LED. Default Example None $ opx-chassis- - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 20
opx-ethtool Display statistics and media information from a Linux interface which maps to a physical port. The output is a subset of the show-stats output for the same physical port interface. Syntax Parameters opx-ethtool [-v | -e | -s | -S] -v Display version information -e Display - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 21
Example (port statistics) base-pas/media/rx-power-measurement-type = 0 base-pas/media/wavelength = 0 base-pas/media/cc_base = 54 base-pas/media/temp-low-alarm-threshold = base-pas/media/tx-power-low-warning-threshold = base-pas/media/insertion-timestamp = 0 base-pas/media/current-voltage = base-pas - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 22
opx_logging_cli Enables logging which is maintained in the var/log/syslog file. You must restart the module after changing logging levels. Syntax opx_logging_cli [show-id | show all module-id {log-level value} | enable | disable] Parameters show-id Display module IDs and current logging levels - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 23
tag: PPID: Platform name: Product name: Hardware version: Number of MAC addresses: Base MAC address: Operating status: Power supplies Slot 1 Present: Vendor name: Service tag: PPID: Platform name: Product name: Hardware version: Operating status: Input: Fan airflow: Slot 2 Present: Vendor name - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 24
Fan 1, PSU slot 1 Operating status: Up Speed (RPM): 6720 Speed (%): 37 Fan 1, Fan tray slot 1 Operating status: Up Speed (RPM): 6916 Speed (%): 38 Fan 2, Fan tray slot 1 Operating status: Up Speed (RPM): 6803 Speed (%): 37 Fan 1, Fan tray slot 2 Operating status: Up Speed ( - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 25
opx-show-stats Displays a dump of port and VLAN statistics. Syntax opx-show-stats [if_stat iface_name filter_list | vlan_stat vlan_ifindex filter_list | clear iface_name vlan_ifindex] Parameters if_stat Statistics for all or specified port interfaces iface_name Physical port such as e101-001 - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 26
. Syntax Parameters Default Example opx-show-system-status None None $ opx-show-system-status System State: running No Failed Service No Modified Package opx-show-transceivers Displays information about the transceiver types present. Syntax opx-show-transceivers [summary] Parameter summary - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 27
... 32 Not Present opx-show-version Displays OpenSwitch OPX software version information. Syntax opx-show-version Parameters None Default None Example $ opx-show-version OS_NAME="OPX" OS_VERSION="2.1.0" PLATFORM="S6000-ON" ARCHITECTURE="x86_64" INTERNAL_BUILD_ID="OpenSwitch Blue Print - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 28
Default Example level_name • ALL • STP • LAG • ROUTER_INTERFACE • NEXT_HOP • SCHEDULER SAI logging level: • debug • info • notice • warning • critical • error None $ opx-switch-log set wred debug 28 Linux management - Dell PowerSwitch S6000 ON | OpenSwitch OPX Administration Guide Release 2.1.0 - Page 29
tag or express service code, pull out the luggage tag on the chassis or enter the show chassis command from the CLI. • To receive additional kinds of technical support, click Contact Us, then click Technical Support. To access system documentation, see www.dell.com/manuals/. To search for drivers
OpenSwitch OPX Administration Guide
Release 2.1.0