OS10 Enterprise Edition User Guide Release 10.3.1E - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 2
of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 3
Contents 1 Getting Started...19 Download OS10 image and license...20 Installation...21 Automatic installation...22 Manual installation...22 Log into OS10...23 Install OS10 license...23 Remote access...24 Configure Management IP address...25 Management Route Configuration...25 Configure user name - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 4
do...46 feature config-os9-style...47 exit...47 license...48 lock...48 management route...49 move...49 no...50 reload...50 show alias...50 show boot...51 show candidate-configuration...52 show environment...54 show inventory...54 show ip management-route...55 show ipv6 management-route...55 show - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 5
Configure interface ranges...74 Energy-efficient Ethernet...75 Enable energy-efficient Ethernet...76 Clear interface counters...76 View EEE status/statistics...76 EEE commands...77 Forward error correction...80 Switch-port profiles...80 S4148-ON series port profiles...81 S4148U-ON port profiles...82 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 6
F_Port commands...106 fc alias...106 fc zone...106 fc zoneset...107 fcoe fcmap...107 feature fc...107 member (alias)...108 member (zone)...108 member (zoneset)...109 name...109 show fc alias...109 show fc ns switch...110 show fc statistics...111 show fc switch...111 show fc zone...112 show fc - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 7
Media endpoint discovery...144 Network connectivity device...144 LLDP-MED capabilities TLV...144 Network policies TLVs...145 Define network policies...146 Packet timer values...146 Disable and re-enable LLDP ...147 Advertise TLVs...148 Network policy advertisement...148 Fast start repeat count...149 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 8
Weight and local preference...226 Multiexit discriminators...227 Origin...227 AS path and next-hop...228 Best path selection...228 More path support...229 Advertise cost...229 4-Byte AS numbers...230 AS number migration...230 Configure border gateway protocol...231 Enable BGP...231 Configure Dual - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 9
Local preference attribute...241 Weight attribute...242 Enable multipath...243 Route-map filters...243 Route reflector clusters...243 Aggregate routes...244 Confederations...245 Route dampening...246 Timers...247 Neighbor soft-reconfiguration...247 BGP commands...248 Equal cost multi-path...273 Load - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 10
360 Dynamic host configuration protocol...360 Packet format and options...360 Configure Server...361 Automatic address allocation...362 Hostname resolution...363 Manual binding entries...364 View DHCP Information...365 System domain name and list...365 DHCP commands...366 DNS commands...371 Network - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 11
Server host settings...388 System-defined user roles...388 Create user name and role...388 SSH Server...389 Security commands...389 Simple network management protocol...397 SNMP commands...397 OS10 image upgrade...398 Boot system partition...399 Upgrade commands...400 7 Access Control Lists...405 IP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 12
deny ip...420 deny ipv6...421 deny tcp...421 deny tcp (IPv6)...422 deny udp...423 deny udp (IPv6)...423 description...424 ip access-group...424 ip access-list...425 ip as-path deny...425 ip as-path permit...426 ip community-list standard deny...426 ip community-list standard permit...427 ip - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 13
seq deny icmp (IPv6)...445 seq deny ip...445 seq deny ipv6...446 seq deny tcp...447 seq deny tcp (IPv6)...447 seq deny udp...448 seq deny udp (IPv6)...449 seq permit...450 seq permit (IPv6)...450 seq permit (MAC)...451 seq permit icmp...452 seq permit icmp (IPv6)...453 seq permit ip...453 seq permit - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 14
-type...469 set next-hop...470 set origin...470 set tag...471 set weight...471 show route-map...471 8 Quality of service...473 Configure quality of service...474 Class-map configuration...475 Policy-map configuration...475 Interface policy-map...476 Control-plane policy-map...477 System policy-map - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 15
priority...504 priority-flow-control mode...504 qos-group dot1p...505 qos-group dscp...505 queue-limit...505 queue qos-group...506 random-detect...507 service-policy...507 set cos...508 set dscp...508 set qos-group...509 shape...509 show class-map...510 show control-plane info...510 show control - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 16
port-detail...536 vlt-domain...537 vlt-port-channel...537 vlt-mac...537 vrrp mode active-active...538 10 Converged data center services...539 Priority flow control...539 PFC configuration notes...540 Configure PFC...541 PFC commands...544 Enhanced transmission selection...548 ETS configuration notes - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 17
polling-interval...579 sflow sample-rate...580 show sflow...580 12 Troubleshoot OS10...582 Diagnostic tools...582 Boot partition and image...583 Monitor status...603 SupportAssist commands...604 Support bundle...610 Event notifications...610 generate support-bundle...611 System monitoring...611 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 18
Frequently asked questions...624 Installation...625 Hardware...625 Configuration...625 Security...626 Layer 2...626 Layer 3...626 System management...626 Access control lists...627 Quality of service...627 Monitoring...628 13 Support resources...629 18 Contents - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 19
(ONIE)-enabled Dell EMC device • OS10 software image stored on an HTTP server or universal serial bus (USB) media • Familiarity with any Linux release Supported Dell EMC platforms • S3048-ON • S4048-ON, S4048T-ON • S6000-ON, S6010-ON • S4128F-ON, S4128T-ON • S4148F-ON, S4148T-ON • S4148U-ON, S4148FE - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 20
run beyond the trial period. See the Quick Start Guide shipped with your device and My Account FAQs for more the License.zip file and follow the instructions in Install license to install the license. service tag of the switch to extend the entitled download period to be the same time as the support - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 21
a manual installation: automatically. • Manual installation - Manually configure your Guide shipped with your device or the platform-specific Installation Guide at www.dell.com/support ONIE prompt and allows for manual installation of an OS10 image During an automatic or manual OS10 installation, if - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 22
from, and xxP represents the version number of the software to install. Install using USB drive You can manually install the OS10 software image using USB media. Verify that the USB storage device supports a FAT or EXT2 file system. Plug the USB storage device into the USB storage port on the device - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 23
The ONIE auto-discovery process discovers the image file at the specified USB path, loads the software image, and reboots. Log into OS10 To log in to OS10 Enterprise Edition, power up the device and wait for the system to perform a power-on self test (POST). Enter admin for both the default user - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 24
Name : S4048-ON PPID : CN0M68YC2829855M0133 Service Tag : CFNNX42 License Details Software : OS10-Enterprise Version : 10.3.0E License Type : PERPETUAL License Duration: Unlimited License Status : Active License location: /mnt/license/CFNNX42.lic Troubleshoot license installation failure An error - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 25
Remote access Linux shell ssh linuxadmin@ip-address password: linuxadmin Configure Management IP address To remotely access OS10, assign an IP address to the Management port. 1 Configure the management interface from CONFIGURATION mode. interface mgmt node/slot/port 2 Configure an IPv4 or IPv6 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 26
then click Download Now. Install the OS10 image on an ONIE-enabled switch with an installed OS10 license. See Install OS10 license for complete instructions. CLI Basics The OS10 command-line interface (CLI) is the software interface you use to access a device running the software - from the console - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 27
names, usernames, and configuration statements. CLI command modes The OS10 CLI has two top-level modes: • EXEC mode - Used to monitor, troubleshoot, check status, and network connectivity. • CONFIGURATION mode - Used to configure network devices. When you enter CONFIGURATION mode, you are changing - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 28
is a sub-mode of CONFIGURATION mode. Interface mode is where you configure Layer 2 and Layer 3 protocols, and IPv4 and IPv6 services specific to an interface: • Physical interfaces include the Management interface and Ethernet ports • Logical interfaces include loopback, port-channel, and virtual - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 29
configure copy debug delete dir discard exit generate help image kill-session license location-led lock move no ping ping6 reload show start support-assist-activity system terminal traceroute unlock validate write Alarm commands Set alias for a command Batch Mode Tell the system where to access the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 30
mac management monitor no ntp policy-map qos-map radius-server pa rameters route-map router sflow snmp-server spanning-tree support-assist system track trust username vlt-domain vrrp Load balancing configurations Logging commands MAC Address Table Configuration Subcommands management interface - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 31
policy-map port-channel processes qos queuing route-map running-configuration sessions sflow spanning-tree startup-configuration storm-control support-assist system tech-support terminal trace track uptime users the session id version vlan vlt vrrp Show network policy NTP associations Show parser - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 32
prefix-list qos-map radius-server route-map sflow snmp spanning-tree support-assist system-qos trust-map Current candidate aaa configuration Current candidate Current candidate spanning-tree configuration Current candidate support-assist configuration Current candidate system-qos configuration - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 33
access vlan 1 no shutdown ! interface vlan 1 no shutdown ! interface mgmt1/1/1 ip address dhcp no shutdown ipv6 enable ipv6 address autoconfig ! support-assist ! policy-map type application policy-iscsi ! class-map type application class-iscsi ! class-map type qos class-trust View compressed - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 34
access vlan 1 no shutdown ! interface vlan 1 no shutdown ! interface mgmt1/1/1 ip address dhcp no shutdown ipv6 enable ipv6 address autoconfig ! support-assist ! policy-map type application policy-iscsi ! class-map type application class-iscsi ! class-map type qos class-trust Show difference between - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 35
command, the current session switches back to the default behavior of committing all configuration changes automatically. Save configuration changes manually OS10# start transaction OS10# configure terminal OS10(config)# OS10(config)# interface ethernet 1/1/1 OS10(config-if-eth1/1/1)# no shutdown - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 36
file from server OS10# copy scp://admin:admin@hostip/backup-9-28.xml config://startup.xml OS10# reload Reload system image Reboot the system manually using the reload command in EXEC mode. You are prompted to confirm the operation. OS10# reload System configuration has been modified. Save? [yes - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 37
The alias command allows you to create shortcuts for commonly used or long commands, and execute long commands along with the parameters. The alias supports the following modes: • Persistent mode - The alias is persistent and can be used in other sessions as well. The aliases created in the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 38
Eth 1/1/18 up 40G A 1 - Eth 1/1/19 up 40G A 1 - Eth 1/1/20 up 40G A 1 - Eth 1/1/21 up 40G A 1 - Eth 1/1/22 up 40G A 1 - Eth 1/1/23 up 40G A 1 - Eth 1/1/24 up 40G A 1 - Eth 1/1/25 up 40G A 1 - Eth 1/1/26 up 40G A 1 - Eth 1/1/27 up 40G A 1 - Eth 1/1/28 up 40G - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 39
Batch mode commands You can create a batch file to simplify routine or repetitive tasks. A batch file is an unformatted text file that contains two or more commands and has a .cmd file name extension. You can use vi or any other editor to create the .cmd file, then use the batch command to execute - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 40
16 SSH commands You can execute commands remotely using an SSH session. This is supported only for show commands. • Enter the show command along with SSH. $ by using the feature config-os9-style command. The current release supports VLAN tagging and port-channel grouping commands. • VLAN Interface - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 41
• no channel-member • Enable the feature to configure commands in an OS9 environment in CONFIGURATION mode. OS10(config)# feature config-os9-style OS10(config)# exit OS10# show running-configuration compressed interface breakout 1/1/28 map 10g-4x feature config-os9-style • Once this feature is - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 42
Feb 15 19:26:1: %Dell EMC (OS10) %Node.1-Unit.1:PRI:OS10 %lognotice:IP_ADDRESS_ADD: IP Address add is successful.:IP 172.17.4.1/24 added successful Supported Releases 10.2.0E or later boot Configures which OS10 image to use the next time the system boots up. Syntax boot system [active | standby - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 43
Use the show boot command to view the configured next boot image. This command is applied immediately. OS10# boot system standby Supported Releases 10.2.0E or later commit Commits changes in the candidate configuration to the running configuration. Syntax commit Parameters None Default Not - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 44
SCP server. • sftp://userid:passwd@hostip/filepath - (Optional) Copy from a remote SFTP server. • supportbundle://filepath - (Optional) Copy from the support-bundle directory. • tftp://hostip/filepath - (Optional) Copy from a remote TFTP server. • usb:filepath - (Optional) Copy from an USB file - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 45
to reboot the switch - reload for the operation to take effect. Use caution when removing the startup configuration. OS10# delete startup-configuration Supported Releases 10.2.0E or later dir Displays files stored in available directories. Syntax Parameters dir [config | coredump | home | image - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 46
) OS10# dir config Directory contents for folder: config Date (modified) Size (bytes) Name 2017-04-26T15:23:46Z 26704 startup.xml Supported Releases 10.2.0E or later discard Discards any changes made to the candidate configuration file. Syntax Parameters Default Command Mode Usage - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 47
next session, you can configure the commands in OS9 format. The current release supports VLAN tagging and Port channel grouping commands. This feature does not have any impact breakout 1/1/28 map 10g-4x feature config-os9-style Supported Releases 10.3.0E or later exit Returns to the next - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 48
is installed in the /mnt/license directory. OS10# license install scp://user:userpwd/10.1.1.10/CFNNX42-NOSEnterpriseLicense.lic License installation success. Supported Releases 10.3.0E or later lock Locks the candidate configuration and prevents any configuration changes on any other CLI sessions - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 49
10.10.20.0/24 10.1.1.1 OS10(config)# management route 172.16.0.0/16 managementethernet Example (IPv6) OS10(config)# management route 10::/64 10::1 Supported Releases 10.2.2E or later move Moves or renames a file on the config or home system directories. Syntax Parameters move [config: | home - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 50
this command, as it reloads the OS10 image and reboots the device. Example OS10# reload Proceed to reboot the system? [confirm yes/no]:y Supported Releases 10.2.0E or later show alias Displays configured alias commands available in both persistent and non-persistent modes. Syntax show alias - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 51
---- ---- govlt Config goint Config shconfig Local showint Local shver Local Number of config aliases : 3 Number of local aliases : 3 Supported Releases 10.3.0E or later Value ----"vlt-domain..." "interface ..." "show runni..." "show inter..." "show versi..." Value ----"vlt-domain - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 52
: 10.2.9999E Standby SW Build Version: 10.2.9999E(3633) Standby Build Date/Time: 2017-01-25T06:36:22Z Next-Boot: active[A] Supported Releases 10.2.0E or later show candidate-configuration Displays the current candidate configuration file. Syntax Parameters show candidate-configuration [aaa - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 53
password $6$q9QBeYjZ$jfxzVqGhkxX3smxJSH9DDz7/3OJc6m5wjF8nnLD7/ VKx8SloIhp4NoGZs0I/UNwh8WVuxwfd9q4pWIgNs5BKH. aaa authentication local snmp-server contact http://www.dell.com/support snmp-server location "United States" logging monitor disable ip route 0.0.0.0/0 10.11.58.1 ! Getting Started 53 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 54
32 switchport access vlan 1 no shutdown ! interface vlan 1 no shutdown ! interface mgmt1/1/1 ip address 10.11.58.145/8 no shutdown ipv6 enable ipv6 address autoconfig ! support-assist ! policy-map type application policy-iscsi ! class-map type application class-iscsi ! class-map type qos class-trust - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 55
A00 CN-0MGDH8-28298-52R-0394 AEIOU## 226 457 410 1 S6000-ON-FANTRAY-3 0MGDH8 A00 CN-0MGDH8-28298-52R-0392 AEIOU## 226 457 410 Supported Releases 10.2.0E or later show ip management-route Displays the IPv4 routes used to access the management port. Syntax Parameters show ip management-route - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 56
------ManagementEthernet 1/1 2001:34::16 State ----Connected Active Supported Releases 10.2.2E or later show license status Displays command to verify the current license for running OS10, its duration, and the service tag of the switch to which it is assigned. Example OS10# show license - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 57
| lldp | logging | monitor | ospf | ospfv3 | policy-map | prefix-list | qos-map | radius-server | route-map | sflow | snmp | spanningtree | support-assist | system-qos | trust-map | users | vlt] Parameters • aaa - (Optional) Current operating AAA configuration. • access-list - (Optional) Current - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 58
vlan 1 no shutdown ! interface vlan 1 no shutdown ! interface mgmt1/1/1 ip address 10.11.58.145/8 no shutdown ipv6 enable ipv6 address autoconfig ! support-assist ! policy-map type application policy-iscsi ! class-map type application class-iscsi ! class-map type qos class-trust 58 Getting Started - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 59
password $6$q9QBeYjZ$jfxzVqGhkxX3smxJSH9DDz7/3OJc6m5wjF8nnLD7/ VKx8SloIhp4NoGZs0I/UNwh8WVuxwfd9q4pWIgNs5BKH. aaa authentication local snmp-server contact http://www.dell.com/support snmp-server location "United States" ip route 0.0.0.0/0 10.11.58.1 ! interface range ethernet 1/1/1-1/1/32 switchport - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 60
-assist ! policy-map type application policy-iscsi ! class-map type application class-iscsi ! class-map type qos class-trust Supported Releases 10.2.0E or later show system Displays system information. Syntax Parameters show system [brief | node-id] • brief - View abbreviated list of system - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 61
2 up 3 up NORMAL 1 6698 up 2 7168 up NORMAL 1 7149 up 2 7104 up Example (node-id) OS10# show system node-id 1 fanout-configured Interface Breakout capable Breakout state Eth 1/1/1 Yes BREAKOUT_1x1 Eth 1/1/2 Yes BREAKOUT_1x1 Eth 1/1/3 Yes BREAKOUT_1x1 Eth 1/1/4 Yes - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 62
) Build Time: 2017-04-13T06:00:50.738-07:00 System Type: S6000-ON Architecture: x86_64 Up Time: 2 weeks 1 day 10:27:15 Supported Releases 10.2.0E or later start Activates the transaction-based configuration mode for the active session. Syntax start transaction Parameters transaction - Enables - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 63
Mode CONFIGURATION Usage Information The system ID is displayed in the stack LED on the front panel. Example OS10(config)# system identifier 1 Supported Releases 10.3.0E or later terminal Sets the number of lines to display on the terminal and enables logging. Syntax terminal {length lines - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 64
number of probe packets that are sent out simultaneously to accelerate traceroute (default 16). • -t tos - (Optional) For IPv4, enter the Type of Service (TOS) and Precedence values to use. 16 sets a low delay; 8 sets a high throughput. • -UL - (Optional) Use UDPLITE for tracerouting (default port - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 65
traceroute 20::1 traceroute to 20::1 (20::1), 30 hops max, 80 byte packets 1 20::1 (20::1) 2.622 ms 2.649 ms 2.964 ms Supported Releases 10.2.0E or later unlock Unlocks a previously locked candidate configuration file. Syntax Parameters Default Command Mode Usage Information Example unlock None - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 66
(Ethernet), port-channels, and VLANs in L2 or L3 modes. Table 1. Interface types Interface type Ethernet (PHY) Management Loopback Port-channel VLAN Supported / default mode L2, L3 / unset N/A L3 / L3 L2, L3 / unset L2, L3 / L3 Requires creation / default status No / no shutdown (enabled) No - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 67
Figure 1. S4148U-ON unified port groups To enable Ethernet interfaces in a unified port group: 1 Configure a unified port group in CONFIGURATION mode. Enter 1/1 for node/slot. The port-group range is 1-10. port-group node/slot/port-group 2 Activate the unified port group for Ethernet operation in - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 68
carries only untagged traffic on the access VLAN - you must manually configure other VLANs for tagged traffic. 1 Select one of 2 configuration before assigning an IP Fibre Channel interfaces OS10 unified port groups support Fibre Channel (FC) interfaces. A unified port group operates in Fibre Channel - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 69
Figure 2. S4148U-ON port groups On a S4148U-ON, the activated FC interfaces depend on the currently configured port profile. For more information, see S4148U-ON port profiles. To enable a fibre channel interface: 1 Configure a unified port group in CONFIGURATION mode. Enter 1/1 for node/slot. The - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 70
VLAN interfaces VLANs are logical interfaces and are, by default, in L2 mode. Physical interfaces and port-channels can be members of VLANs. OS10 supports inter-VLAN routing. You can add IP addresses to VLANs and use them in routing protocols in the same manner that physical interfaces are used - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 71
address is 120.120.120.120/24 Mode of IPv4 Address Assignment : MANUAL MTU 1532 bytes Flowcontrol rx false tx false ARP type: ARPA, ARP Timeout: a port-channel must contain interfaces of the same interface type and speed. OS10 supports up to 128 port-channels, with up to 16 10G or 40G ports per - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 72
configuration settings - only the description and shutdown or no shutdowncommands are supported. You cannot add an IP address or a static MAC address A static port-channel (LAG) contains member interfaces that you manually assign using the channel-group command. OS10(config)# interface port-channel - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 73
LACP enables ports to be dynamically bundled as members of a port-channel. To configure a port for LACP operation, use the channelgroup mode command. Active and passive modes allow LACP to negotiate between ports to determine if they can form a port -channel based on their configuration settings. - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 74
When you configure an IP and MAC hashing scheme at the same time, the MAC hashing scheme takes precedence over the IP hashing scheme. • Select one or more methods of load balancing and replace the default IP 4-tuple method of balancing traffic over a port-channel in CONFIGURATION mode. OS10(config - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 75
regular power mode only during data transmission. EEE is enabled on devices that support LOW POWER IDLE (LPI) mode. Such devices can save power by entering LPI on both ends of the link saves power by shutting down certain services. EEE transitions into and out of LPI mode transparently to upper- - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 76
Enable energy-efficient Ethernet To reduce power consumption, enable EEE. EEE is disabled by default. 1 Enter the physical Ethernet interface information in CONFIGURATION mode. interface ethernet node/slot/port[:subport] 2 Enable EEE in INTERFACE mode. eee Enable EEE OS10(config)# interface ethernet - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 77
EXEC Use this command to clear all EEE counters. OS10# clear counters interface eee Clear all eee counters [confirm yes/no]:yes Supported Releases 10.3.0E or later clear counters interface ethernet eee Clears EEE counters on a specified interface. Syntax Parameters Default Command Mode Usage - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 78
)# interface ethernet 1/1/1 OS10(conf-if-eth1/1/1)# eee Example (Disable EEE) OS10(config)# interface ethernet 1/1/2 OS10(conf-if-eth1/1/2)# no eee Supported Releases 10.3.0E or later show interface eee Displays the EEE status for all interfaces. Syntax show interface eee Parameters None - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 79
Command Mode EXEC Example OS10# show interface ethernet 1/1/48 eee Port EEE Status Speed Duplex Eth 1/1/48 on up 1000M Supported Releases 10.3.0E or later show interface ethernet eee statistics Displays EEE statistics for a specified interface. Syntax show interface ethernet - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 80
to the protocol, the character is rejected and an underscore or blank is displayed in its place. • CL74-FC - Supports 25G and 50G • CL91-RS - Supports 100G • CL108-RS - Supports 25G and 50G • off - Disables FEC Configure FEC OS10(config)# interface ethernet 1/1/1 OS10(conf-if-eth1/1/1)# fec CL74-FC - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 81
Forwarding Table (UFT) mode • ECMP maximum paths You must manually reconfigure other settings on a switch after you apply a new and Ethernet ports, see S4148U-ON port profiles. An S4148U-ON unified port supports Fibre Channel and Ethernet modes. For example, profile-1 enables 10G speed on forty - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 82
-54: • 10GE mode is an SFP+ 10GE port or a 4x10G breakout of a QSFP+ port. • 40GE mode is a QSFP+ port. For example, all S4148U-ON activate support 10G speed on unified ports 1-24 and Ethernet ports 31-54, but only profile-1 and profile-2 activate QSFP+ ports 27-28 in 40GE mode with - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 83
connect FC devices for plug-and-play; profile-2 is designed for a standard Ethernet-based data network. **Oversubscription: Configure oversubscription to support bursty storage traffic on a Fibre Channel interface. Oversubscription allows a port to operate faster, but may result in traffic loss. To - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 84
• vlan vlan-id - Display the VLAN interface information (1 to 4094). View interface information OS10# show interface Ethernet 1/1/1 is up, line protocol is up Hardware is Dell EMC Eth, address is 00:0c:29:98:1b:79 Current address is 00:0c:29:98:1b:79 Pluggable media present, QSFP-PLUS type is - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 85
unassigned OK? Method NO Manual NO Manual YES Manual YES Manual YES Manual YES Manual NO Manual NO Manual NO Manual Status administratively down administratively )# interface ethernet 1/1/2:1 OS10(conf-if-eth1/1/2:1)# channel-group 20 mode active Supported Releases 10.3.0E or later Interfaces 85 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 86
configured for each interface. • The no version of this command deletes the description. Example OS10(conf-if-eth1/1/7)# description eth1/1/7 Supported Releases 10.2.0E or later duplex Configures duplex mode on the Management port. Syntax Parameters duplex {full | half | auto} • full - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 87
on 25G, 50G, and 100G interfaces. Syntax fec {CL74-FC | CL91-RS | CL108-RS | off} Parameters • CL74-FC - Supports 25G and 50G • CL91-RS - Supports 100G • CL108-RS - Supports 25G and 50G • off - Disables FEC Defaults • For 25G and 50G interfaces: off • For 100G interfaces: CL91-RS Command Mode - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 88
CONFIGURATION The no version of this command deletes the loopback interface. OS10(config)# interface loopback 100 OS10(conf-if-lo-100)# Supported Releases 10.2.0E or later interface mgmt Configures the Management port. Syntax interface mgmt node/slot/port Parameters node/slot/port - Enter - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 89
CONFIGURATION The no version of this command deletes the interface. OS10(config)# interface port-channel 10 OS10(conf-if-po-10)# Supported Releases 10.2.0E or later interface range Configures a range of Ethernet, port-channel, or VLAN interfaces for bulk configuration. Syntax interface - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 90
interface vlan vlan-id vlan-id - Enter the VLAN ID number (1 to 4094). VLAN 1 CONFIGURATION FTP, TFTP, MAC ACLs, and SNMP operations are not supported - IP ACLs are supported on VLANs only. The no version of this command deletes the interface. OS10(config)# interface vlan 10 OS10(conf-if-vl-10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 91
VLAN INTERFACE Use the no version of this command to remove the configuration. OS10(config)# interface vlan 11 OS10(conf-if-vl-11)# mgmt Supported Releases 10.3.0E or later mode Configures a front-panel unified port group to operate in Fibre Channel or Ethernet mode with the specified speed on - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 92
Eth 10g-4x Example: Reset mode OS10(conf-pg-1/1/2)# mode FC 16g-2x OS10(conf-pg-1/1/2)# no mode OS10(conf-pg-1/1/2)# mode Eth 10g-4x Supported Releases 10.3.1E or later mtu Sets the link maximum transmission unit (MTU) frame size for an Ethernet L2 or L3 interface. Syntax Parameters Default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 93
view the ports that belong to a port group, enter the show port-group command. OS10(config)# port-group 1/1/8 OS10(conf-pg-1/1/8)# Supported releases 10.3.1E or later show interface Displays interface information. Syntax Parameters show interface [type] interface type - Enter the interface type - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 94
10 (Up) Eth 1/1/11 (Down) Eth 1/1/12 (Inact) 23 L2 up 20:34:32 Eth 1/1/20 (Up) Eth 1/1/21 (Up) Eth 1/1/22 (Up) Supported Releases 10.2.0E or later show link-bundle-utilization Displays information about the link-bundle utilization. Syntax show link-bundle-utilization Parameters None Default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 95
-Channel Type Protocol Member Ports 22 port-channel22 (U) Eth STATIC 1/1/10(P) 1/1/11(P) 1/1/14(P) 1/1/16(P) 1/1/19(P) 23 port-channel23 (D) Eth STATIC Supported Releases 10.2.0E or later show port-group Displays the current port-group configuration on a switch. Syntax Parameters Default Command - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 96
20 1/1/6 FC 16g-2x 21 22 23 24 1/1/7 Eth 100g-1x 25 1/1/8 Eth 40g-1x 26 1/1/9 Eth 100g-1x 29 1/1/10 Eth 40g-1x 30 Supported Releases 10.3.1E or later show switch-port-profile Displays the current and default port profile on a switch. Syntax Parameters show switch-port-profile node - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 97
on an interface that is a member of a port-channel. Example OS10(config)# interface ethernet 1/1/7 OS10(conf-if-eth1/1/7)# no shutdown Supported Releases 10.2.0E or later speed (Fibre Channel) Configures the transmission speed of a Fibre Channel interface. Syntax Parameters speed {8 | 16 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 98
device. Defaults Command Mode Usage Information Auto INTERFACE The speed command is supported only on the Management and Fibre Channel interfaces. This command is not supported on Ethernet interfaces. • When you manually configure the management port speed, match the speed of the remote device - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 99
31-54) and QSFP28 100G ports (25-26 and 29-30) are enabled. QSFP28 ports support 100GE and 4x10G, 4x25G, and 2x50G breakouts. • profile-2 - SFP+ 10G ports (1-24 40G mode (25-26 and 29-30) are enabled. QSFP+ and QSFP28 ports support 40GE and 4x10G breakouts. • profile-3 - SFP+ 10G ports (5-24 and 31- - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 100
Unified Forwarding Table (UFT) mode • ECMP maximum paths You must manually reconfigure other settings on a switch after you apply a new port the reload. OS10(config)# do write memory OS10(config)# do reload Supported Releases 10.3.0E or later switchport access vlan Assigns access VLAN membership - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 101
configures an interface to transmit tagged VLAN traffic. You must manually configure VLAN membership for a trunk port with the switchport on VLAN 1. Example OS10(conf-if-eth1/1/7)# switchport mode access Supported Releases 10.2.0E or later switchport trunk allowed vlan Configures the tagged - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 102
Example OS10(conf-if-ma-1/1/1)# switchport trunk allowed vlan 1000 OS10(conf-if-ma-1/1/1)# no switchport trunk allowed vlan 1000 Supported Releases 10.2.0E or later 102 Interfaces - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 103
Fibre channel Fibre channel fabric port (F_Port) is the switch port that connects the Fibre Channel (FC) fabric to a node. S4148U-ON switches support F_Port. Enable Fibre channel F_Port mode globally using the feature fc domain-ID domain-ID command in CONFIGURATION mode. Enable Fibre channel F_Port - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 104
fcoe fcmap 0xEFC64 zoneset activate set zone default-zone permit OS10# show vfabric Fabric Name 100 Fabric Type FPORT Fabric Id 100 Vlan Id 1023 FC-MAP 0xEFC64 Config-State ACTIVE Oper-State UP Switch Config Parameters Domain ID 100 Switch Zoning Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 105
5 Create a zoneset using the fc zoneset zoneset-name command in CONFIGURATION mode. The switch enters Zoneset CONFIGURATION mode. 6 Add the existing zones to the zoneset with the member zone-name command in Zoneset CONFIGURATION mode. 7 Activate the zoneset using the zoneset activate zoneset-name - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 106
)# member wwn 21:00:00:24:ff:7b:f5:c9 OS10(config-fc-alias-test)# member wwn 20:25:78:2b:cb:6f:65:57 Supported Releases 10.3.1E or later fc zone Creates an FC zone and adds members to the zone. An FC zone can have a maximum of 527 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 107
Information The no version of this command disables the FC map. Example OS10(config)# vfabric 100 OS10(conf-vfabric-100)# fcoe fcmap 0xEFC64 Supported Releases 10.3.1E or later feature fc Enables the F_Port globally. Syntax feature fc domain-id domain-id Parameters domain-id - Enter the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 108
and zoning configurations. Example OS10(config)# feature fc domain-id 100 Supported Releases 10.3.1E or later member (alias) Add members to (config-fc-alias-test)# member wwn 20:25:78:2b:cb:6f:65:57 Supported Releases 10.3.1E or later member (zone) Adds members to existing zones. Identify - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 109
Usage Information The no version of this command removes the vfabric name.. Example OS10(config)# vfabric 100 OS10(conf-vfabric-100)# name test_vfab Supported Releases 10.3.1E or later show fc alias Displays the details of a FC alias and its members. Syntax Parameters Default Command Mode - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 110
NameServer Registered for SCN Switch Name Domain Id Switch Port FC-Id Port Name Node Name Class of Service Symbolic Port Name Symbolic Node Name Port Type Registered with NameServer Registered for SCN 10:00:14: :22:19 21:00:00:24:ff:7b:f5:c8 Supported Releases 10.3.1E or later 110 Fibre channel - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 111
: 1 Number of FLOGI Rejects : 0 Number of FDISC Accepts : 0 Number of FDISC Rejects : 0 Number of FLOGO Accepts : 0 Number of FLOGO Rejects : 0 Supported Releases 10.3.1E or later show fc switch Displays the FC switch parameters. Syntax show fc switch Parameters None Default Not - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 112
:c8 10:00:00:90:fa:b8:22:19 21:00:00:24:ff:7f:ce:ee 21:00:00:24:ff:7f:ce:ef Supported Releases 10.3.1E or later show fc zoneset Displays the FC zonesets, the zones in the zoneset, and the zone members. Syntax show fc zoneset - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 113
:1b 50:00:d3:10:00:ec:f9:05 50:00:d3:10:00:ec:f9:1f 20:35:78:2b:cb:6f:65:57 Supported Releases 10.3.1E or later show vfabric Displays vfabric details. Syntax show vfabric Parameters None Default Not configured Fibre channel 113 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 114
/1/20 fibrechannel1/1/21 fibrechannel1/1/22 fibrechannel1/1/23 fibrechannel1/1/24 fibrechannel1/1/25:1 fibrechannel1/1/29:1 fibrechannel1/1/30:1 fibrechannel1/1/30:3 Supported Releases 10.3.1E or later vfabric Configures a virtual fabric (vfabric). Enable the F_Port before configuring - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 115
version of this command removes the vfabric from the FC interface. Example OS10(config)# interface fibrechannel 1/1/1 OS10(conf-if-fc1/1/1)# vfabric 100 Supported Releases 10.3.1E or later vlan Associate an existing VLAN ID to the vfabric to carry traffic. Create the VLAN ID before associating - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 116
between FC nodes in the absence of an active zoneset. Example OS10(config)# vfabric 100 OS10(conf-vfabric-100)# zone default-zone permit Supported Releases 10.3.1E or later zoneset activate Activates an existing zoneset. You can activate only one zoneset in a vfabric. Syntax zoneset activate - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 117
4 Layer 2 802.1X Verifies device credentials prior to sending or receiving packets using the extensible authentication protocol (see 802.1X Commands). Link Aggregation Control Protocol (LACP) Exchanges information between two systems and automatically establishes a LAG between the systems (see - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 118
NOTE: OS10 supports only RADIUS as the back-end authentication server. The authentication process involves three devices: • Supplicant - The device attempting to access the network performs the role - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 119
802.1X with EAP-MD5, EAP-OTP, EAP-TLS, EAP-TTLS, PEAPv0, PEAPv1, and MS-CHAPv2 with PEAP and all platforms support RADIUS as the authentication server. If the primary RADIUS server becomes unresponsive, the authenticator begins using a secondary RADIUS server if configured. NOTE: 802.1X is - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 120
Enable 802.1X 1 Enable 802.1X globally in CONFIGURATION mode. dot1x system-auth-control 2 Enter an interface or a range of interfaces in INTERFACE mode. interface range 3 Enable 802.1X on the supplicant interface only in INTERFACE mode. dot1x port-control auto Configure and verify 802.1X - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 121
reasons why the supplicant might fail to respond - the supplicant may have been booting when the request arrived, there may be a physical layer problem, and so on. 1 Configure the amount of time that the authenticator waits before re-transmitting an EAP Request Identity frame in INTERFACE mode - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 122
Failure quiet period If the supplicant fails the authentication process, the authenticator sends another Request Identity frame after 30 seconds by default. The quiet period is a transmit interval time after a failed authentication. The Request Identity Re-transmit interval is for an unresponsive - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 123
force-authorized (default) force-unauthorized auto This is an authorized state. A device connected to this port does not use the authentication process but can communicate on the network. Placing the port in this state is same as disabling 802.1X on the port. forceauthorized is the default mode. - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 124
Configure and verify reauthentication time period OS10(config)# interface range ethernet 1/1/7-1/1/8 OS10(conf-range-eth1/1/7-1/1/8)# dot1x re-authentication OS10(conf-range-eth1/1/7-1/1/8)# dot1x timeout re-authperiod 3600 OS10(conf-range-eth1/1/7-1/1/8)# show dot1x interface ethernet 1/1/7 802. - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 125
Port Auth Status: Re-Authentication: Tx Period: Quiet Period: Supplicant Timeout: Server Timeout: Re-Auth Interval: Max-EAP-Req: Host Mode: Auth PAE State: Backend State: UNAUTHORIZED Enable 120 seconds 120 seconds 45 seconds 60 seconds 3600 seconds 5 MULTI_HOST Initialize Initialize View - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 126
to 10). 2 INTERFACE The no version of this command resets the value to the default. OS10(conf-range-eth1/1/7-1/1/8)# dot1x max-req 4 Supported Releases 10.2.0E or later dot1x port-control Controls the 802.1X authentication performed on the interface. Syntax dot1x port-control {force-authorized - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 127
The no version of this command resets the value to the default. Example OS10(conf-range-eth1/1/7-1/1/8)# dot1x timeout quiet-period 120 Supported Releases 10.2.0E or later dot1x timeout re-authperiod Sets the number of seconds between re-authentication attempts. Syntax dot1x timeout re - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 128
65535). 30 seconds INTERFACE The no version of this command resets the value to the default. OS10(conf-range-eth1/1/7-1/1/8)# dot1x timeout supp-timeout 45 Supported Releases 10.2.0E or later dot1x timeout tx-period Sets the number of seconds that the device waits for a response to an EAP-request - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 129
and State info for Supplicant: 01:80:c2:00:01:1c Port Auth Status: UNAUTHORIZED Untagged VLAN id: 1 Auth PAE State: Initialize Backend State: Idle Supported Releases 10.2.0E or later Layer 2 129 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 130
Link aggregation control protocol Group Ethernet interfaces to form a single link layer interface called a LAG or port-channel. Aggregating multiple links between physical interfaces creates a single logical LAG, which balances traffic across the member links within an aggregated Ethernet bundle and - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 131
Configure LACP OS10(config)# lacp system-priority 65535 OS10(config)# interface range ethernet 1/1/7-1/1/8 OS10(conf-range-eth1/1/7-1/1/8)# lacp port-priority 4096 OS10(conf-range-eth1/1/7-1/1/8)# lacp rate fast Verify LACP configuration OS10(conf-range-eth1/1/7-1/1/8)# do show running-configuration - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 132
Configure LACP timeout OS10(conf-if-eth1/1/29)# lacp rate fast View port status OS10# show lacp port-channel Port-channel 20 admin up, oper up, mode lacp Actor System ID: Priority 32768, Address f8:b1:56:00:02:33 Partner System ID: Priority 4096, Address 10:11:22:22:33:33 Actor Admin Key 20, Oper - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 133
Bravo LAG configuration summary OS10(config)# interface port-channel 1 OS10(conf-if-po-1)# exit OS10(config)# interface ethernet 1/1/49 OS10(conf-if-eth1/1/49)# no switchport OS10(conf-if-eth1/1/49)# channel-group 1 mode active OS10(conf-if-eth1/1/49)# interface ethernet 1/1/50 OS10(conf-if-eth1/1/ - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 134
0 runts, 0 giants, 0 throttles 0 CRC, 0 overrun, 465 discarded Output statistics: 7840 packets, 938965 octets 0 64-byte pkts,1396 over 64-byte pkts, 6444 over 127-byte pkts 0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts 7840 Multicasts, 0 Broadcasts,0 Unicasts 0 throttles, 0 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 135
| passive} • number - Enter the port-channel group number (1 to 128). The maximum number of port-channels is 128. The maximum physical port/maximum NPU is supported. • mode - Enter the interface port-channel mode. Layer 2 135 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 136
10 mode active OS10(conf-if-eth1/1/10)# exit OS10(config)# interface ethernet 1/1/11 OS10(conf-if-eth1/1/11)# channel-group 10 mode active Supported Releases 10.2.0E or later clear lacp counters Clears the statistics for all interfaces for LACP groups. Syntax clear lacp counters [interface port - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 137
The no version of this command resets the maximum bundle size to the default value. OS10(conf-if-po-10)# lacp max-bundle 10 Supported Releases 10.2.0E or later lacp port-priority Sets the priority for the physical interfaces for LACP. Syntax Parameters Default Command Mode Usage Information - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 138
each device. The no version of this command resets the system priority to the default value. OS10(config)# lacp system-priority 32768 Supported Releases 10.2.0E or later show lacp counter Displays information about LACP statistics. Syntax show lacp counter [interface port-channel channel-number - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 139
=passive LACP_Timeout=Long Timeout(30s) Synchronization=IN_SYNC Collecting=true Distributing=true Partner Admin State=BCEGIKNP Partner Oper State=BDEGIKMO Supported Releases 10.2.0E or later show lacp neighbor Displays information about LACP neighbors. Syntax show lacp neighbor [interface port - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 140
Partner Port: 178 Partner Port Priority: 32768 Partner Oper Key: 1 Partner Oper State:aggregation synchronization collecting distributing defaulted expired Supported Releases 10.2.0E or later show lacp port-channel Displays information about LACP port-channels. Syntax show lacp port-channel - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 141
system ID is different for each device. OS10# show lacp system-identifier Actor System ID: Priority 32768, Address 90:b1:1c:f4:9b:8a Supported Releases 10.2.0E or later Link layer discovery protocol LLDP enables a LAN device to advertise its system and receive system information from adjacent LAN - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 142
configuration information. These sub-types are management TLVs, IEEE 802.1, IEEE 802.3, and TIA-1057 organization-specific TLVs. Optional TLVs OS10 supports basic TLVs, IEEE 802.1, and 802.3 organizationally-specific TLVs, and TIA-1057 organizationally-specific TLVs. A basic TLV is an optional TLV - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 143
and bit rate settings of the sending device. Also configuration/status indicates whether the current settings are due to auto-negotiation or due to manual configuration. 127 - Power via MDI Not supported. 127 - Maximum frame size Maximum frame size capability of the MAC and PHY. Layer 2 143 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 144
address LCI • Emergency call services ELIN 127/4 - Extended Power requirements, priority, and power status. power-via-MDI LLDP-MED capabilities TLV The LLDP-MED capabilities TLV communicates the types of TLVs that the endpoint device and the network connectivity device support. The value of the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 145
LLDP-MED capabilities Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bits 6-15 LLDP-MED capabilities Network policy Location ID Extended power via MDI-PSE Extended power via MDI-PD Inventory Reserved LLDP-MED device types 0 1 2 3 4 5-255 Type not defined Endpoint class 1 Endpoint class 2 Endpoint class 3 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 146
and similar applications supporting streaming video services that require specific network policy treatment. 8 - Video signaling Used only if video control packets use a separate network policy than video data. 9-255 - Reserved - Define network policies You can manually - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 147
2 Enter the multiplier value for the hold time in CONFIGURATION mode. lldp holdtime-multiplier 3 Enter the delay (in seconds) for LLDP initialization on any interface in CONFIGURATION mode. lldp reinit Configure LLDPDU timer OS10(config)# lldp timer 60 OS10(config)# do show lldp timers LLDP Timers: - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 148
Enable LLDP OS10(config)# interface ethernet 1/1/1 OS10(conf-if-eth1/1/1)# lldp transmit OS10(conf-if-eth1/1/1)# lldp receive Disable LLDP globally OS10(config)# no lldp enable Advertise TLVs Configure the system to advertise TLVs out of all interfaces or specific interfaces. If you configure an - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 149
interval. Change the number of packets a device sends per second - up to 10. Rapid availability is crucial for applications such as emergency call service location (E911). • Enable fast start repeat count which is the number of packets sent during activation in CONFIGURATION mode (1 to 10, default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 150
View LLDP global traffic OS10# show lldp traffic LLDP traffic statistics: Total Frames Out : 0 Total Entries Aged : 0 Total Frames In : 0 Total Frames Received In Error : 0 Total Frames Discarded : 0 Total TLVS Unrecognized : 0 Total TLVs Discarded : 0 View LLDP interface traffic - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 151
Enabled System Capabilities: Repeater, Bridge, Router Remote Max Frame Size: 0 Remote Aggregation Status: false MAC PHY Configuration: Auto-neg supported: 1 Auto-neg enabled: 1 Auto-neg advertised capabilities: 10BASE-T half duplex mode, 10BASE-T full duplex mode, 100BASE-TX half duplex - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 152
clear lldp counters None Not configured EXEC The counter default value resets to zero for all physical interfaces. OS10# clear lldp counters Supported Releases 10.2.0E or later clear lldp table Clears LLDP neighbor information for all interfaces. Syntax Parameters Default Command Mode Usage - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 153
disabled. The no version of this command disables LLDP globally irrespective of whether LLDP is manually enabled on an interface. OS10(config)# lldp enable Supported Releases 10.3.1E or later lldp holdtime-multiplier Configures the multiplier value for the hold time (in seconds). Syntax lldp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 154
or lldp med disable command to disable LLDP-MED on a specific interface. OS10(conf-if-eth1/1/1)# lldp med disable Supported Releases 10.2.0E or later lldp med network-policy Manually defines an LLDP-MED network policy. Syntax lldp-med network-policy number app {voice | voice-signaling | guest - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 155
Usage Information Example Not configured INTERFACE Attach only one network policy for per interface. OS10(conf-if-eth1/1/5)# lldp med network-policy add 1 Supported Release 10.2.0E or later lldp med tlv-select Configures the LLDP-MED TLV type to transmit or receive. Syntax Parameters lldp med - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 156
seconds Command Mode CONFIGURATION Usage Information The no version of this command resets the value to the default. Example OS10(config)# lldp reinit 5 Supported Releases 10.2.0E or later lldp timer Configures the rate (in seconds) at which LLDP packets send to the peers. Syntax lldp timer - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 157
conf-if-eth1/1/3)# lldp tlv-select dot1tlv port-vlan-id Example (Link Aggregation) OS10(conf-if-eth1/1/3)# lldp tlv-select dot1tlv link-aggregation Supported Releases 10.2.0E or later lldp tlv-select dot3tlv Enables or disables the dot3 TLVs to transmit in LLDP packets. Syntax Parameters lldp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 158
The no version of this command disables the transmission of LLDP packets on a specific interface. OS10(conf-if-eth1/1/9)# lldp transmit Supported Releases 10.2.0E or later show lldp interface Displays the LLDP information advertised from a specific interface. Syntax show lldp interface ethernet - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 159
errors None Not configured EXEC None OS10# show lldp errors Total Memory Allocation Failures: 0 Total Input Queue Overflows: 0 Total Table Overflows: 0 Supported Release 10.2.0E or later show lldp med Displays the LLDP MED information for all the interfaces. Syntax Parameters Default Command - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 160
/1/22 | ethernet1/1/23 | ethernet1/1/24 | ethernet1/1/25 | ethernet1/1/26 | ethernet1/1/27 | ethernet1/1/28 | ethernet1/1/29 | ethernet1/1/30 | ethernet1/1/31 | ethernet1/1/32 | Supported Releases 10.2.0E or later Yes| Yes| Yes| Yes| Yes| Yes| Yes| Yes| Yes| Yes| Yes| Yes| Yes| Yes| Yes| No| Yes - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 161
interface ethernet 1/1/1 Loc PortID Rem Host Name Rem Port Id Rem Chassis Id ethernet1/1/1 OS10 ethernet1/1/2 4:17:eb:f7:06:c4 Supported Releases 10.2.0E or later show lldp timers Displays the LLDP hold time, delay time, and update frequency interval configuration information. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 162
port-description system-name system-description system-cababilities management-address port-vlan mac-phy-config link-aggregation max-frame-size Supported Releases 10.2.0E or later show lldp traffic Displays LLDP traffic information including counters, packets transmitted and received, discarded - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 163
none Network Policy Profile 30 voice vlan 30 cos 5 Interface: none Network Policy Profile 36 voice vlan 4 cos 3 Interface: ethernet 1/1/1,ethernet 1/1/3-5 Supported Releases 10.2.0E or later Media Access Control All Ethernet switching ports maintain media access control (MAC) address tables. Each - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 164
Static MAC Address A static MAC address entry is one that you manually configure. A static entry is not subject to aging. • Create a static MAC address entry in the MAC address table in CONFIGURATION mode. mac-address-table static - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 165
all dynamic entries from the address table. OS10# clear mac address-table dynamic all Example (VLAN) OS10# clear mac address-table dynamic vlan 20 Supported Releases 10.2.0E or later mac address-table aging-time Configures the aging time for entries in the L2 address table. Syntax mac address - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 166
entries. The aging time counts from the last time that the device detected the MAC address. OS10(config)# mac address-table aging-time 3600 Supported Releases 10.2.0E or later mac address-table static Configures a static entry for the L2 MAC address table. Syntax mac address-table static mac - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 167
protocol is compatible with RSTP and RPVST+. When you enable MST, all ports in Layer 2 mode participate in MST. Keep in mind that OS10 only supports one MST region. Load balancing can be achieved using the MST protocol. When three VLANs are mapped to two MSTIs, VLAN 100 traffic takes a different - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 168
Configuring MST is a four-step process: 1 Enable MST, if the current running STP version is not MST. 2 (Optional) Map the VLANs to different instances to achieve load balancing. 3 Ensure the same region name is configured in all the bridges running MST. 4 (Optional) Configure the revision number. - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 169
Create instances You can create multiple MSTP instances and map VLANs. A single MSTI provides no more benefit than RSTP. To take full advantage of the MST protocol, create multiple MSTIs and map VLANs to them. 1 Enter an instance number in CONFIGURATION mode. spanning tree mst configuration 2 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 170
ethernet1/1/17 128.324 128 200000000 BLK 0 32768 90b1.1cf4.a523 128.324 ethernet1/1/18 128.328 128 200000000 BLK 0 32768 90b1.1cf4.a523 128.328 ethernet1/1/19 128.332 128 200000000 BLK 0 32768 90b1.1cf4.a523 128.332 ethernet1/1/20 128.336 128 200000000 BLK 0 32768 90b1.1cf4.a523 128.336 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 171
Non-Dell hardware OS10 supports only one MST region. For a bridge to be in the same MST region as another, the three unique attributes (name, revision, and VLAN-to-instance- - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 172
4 Change the max-hops parameter in CONFIGURATION mode (1 to 40, default 20). spanning-tree mst max-hops number MST configuration OS10(config)# spanning-tree mst OS10(config)# spanning-tree mst forward-time 16 OS10(config)# spanning-tree mst hello-time 5 OS10(config)# spanning-tree mst max-age 10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 173
by securely enforcing the active network topology. OS10 supports BPDU filtering, BPDU guard, root guard, and flooding of BPDUs from an erroneous device. Enabling BPDU Filtering instructs the hardware to drop BPDUs and prevents flooding from reaching the state after manual intervention. Layer 2 173 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 174
Root guard Loop guard Avoids bridging loops and preserves the root bridge position during network transitions. STP selects the root bridge with the lowest priority value. During network transitions, another bridge with a lower priority may attempt to become the root bridge and cause unpredictable - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 175
Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ethernet1/1/4 128.272 128 500 BLK 500 32769 90b1.1cf4.a911 128.272 BPDU guard OS10(config)# interface ethernet 1/1/4 OS10(conf-if-eth1/1/4)# spanning-tree bpduguard enable OS10(conf-if-eth1/1/4)# do show spanning-tree - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 176
debug direction. • events - Debugs PVST events. Default Command Mode Usage Information Example Not configured EXEC None OS10# debug spanning-tree bpdu rx Supported Releases 10.2.0E or later spanning-tree mst forward-time Configures a time interval for the interface to wait in the Blocking state - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 177
to the default. OS10(config)# spanning-tree mst forward-time 16 Supported Releases 10.2.0E or later spanning-tree mst hello-time Sets the to the default. Example OS10(config)# spanning-tree mst max-age 10 Supported Releases 10.2.0E or later spanning-tree mst max-hops Configures the maximum - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 178
the port. The command configuration applies to all common IST (CIST) in the MST region. OS10(config)# spanning-tree mst max-hops 30 Supported Releases 10.2.0E or later instance Configures MST instances and one or multiple VLANs mapped to the MST instance. Syntax instance instance-number {vlan - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 179
devices, ensure the revision number value matches on all the devices (see Non-Dell Hardware). Example OS10(conf-mst)# revision 10 Supported Releases 10.2.0E or later show spanning-tree mst Displays MST configuration information. Syntax show spanning-tree mst configuration Parameters None - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 180
3 4 4 5 5 6 Supported Releases 10.2.0E or later show spanning-tree msti Displays MST instance information. Syntax show spanning-tree msti [instance-number [brief | guard | interface interface]] Parameters • - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 181
Information Example Disabled INTERFACE Use the enable parameter to enable BPDU filtering. OS10(conf-if-eth1/1/4)# spanning-tree bpdufilter enable Supported Releases 10.2.0E or later spanning-tree bpduguard Enables or disables BPDU guard on an interface. Syntax spanning-tree bpduguard {enable - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 182
If the port receives a BPDU, it is placed in the Error-Disabled state as a protective measure. OS10(conf-if-eth1/1/4)# spanning-tree bpduguard enable Supported Releases 10.2.0E or later spanning-tree guard Enables or disables loop guard or root guard on an interface. Syntax spanning-tree guard - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 183
of this command resets the value to the default. OS10(config)# spanning-tree mst 0 priority 0 OS10(config)# spanning-tree mst 2 root primary Supported Releases 10.2.0E or later spanning-tree mst force-version Configures a forced version of STP to transmit BPDUs. Syntax spanning-tree mst force - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 184
port if several ports have the same cost. OS10(conf-if-eth1/1/1)# spanning-tree msti 1 priority 0 OS10(conf-if-eth1/1/1)# spanning-tree msti 1 cost 3 Supported Releases 10.2.0E or later spanning-tree port Sets the port type as the EdgePort. Syntax spanning-tree port type edge Parameters None - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 185
3 Enable Rapid-PVST+ (only required if another variation of STP is present). 4 (Optional) Select a non-default bridge-priority for the VLAN for load balancing. By default, each VLAN instance is assigned default bridge priority 32768. For example, all three instances have the same forwarding topology - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 186
Enable RPVST+ By default, RPVST+ is enabled and creates an instance only after you add the first member port to a VLAN. Port-channel or physical interfaces must be a member of a VLAN to participate in RPVST+. Add all physical and port-channel interfaces to the default VLAN (VLAN1). • Enable the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 187
We are the root of VLAN 1 Configured hello time 2, max age 20, forward delay 15 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ethernet1/1/5 128.276 128 500 FWD 0 4097 90b1.1cf4.a523 128.276 ethernet1/1/6 128.280 128 500 FWD 0 4097 90b1.1cf4.a523 128.280 Interface - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 188
ethernet1/1/8 Disb 128.288 128 200000000 FWD 0 AUTO No ethernet1/1/9 Disb 128.292 128 200000000 FWD 0 AUTO No ethernet1/1/10 Disb 128.296 128 200000000 FWD 0 AUTO No ethernet1/1/11 Disb 128.300 128 200000000 FWD 0 AUTO No Root assignment RPVST+ assigns the root bridge according to the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 189
Port enabled with loop guard conditions • Loop guard is supported on any STP-enabled port or port-channel interface in RPVST+ mode. • You cannot enable root guard and loop guard at the same time on - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 190
EXEC Clear all STP counters on the device per Ethernet interface or port-channel. OS10# clear spanning-tree counters interface port-channel 10 Supported Releases 10.2.0E or later clear spanning-tree detected-protocol Forces the MST ports to renegotiate with neighbors. Syntax clear spanning-tree - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 191
11 128.300 128 200000000 FWD 0 32769 0000.0000.0000 128.300 ethernet1/1/12 128.304 128 200000000 FWD 0 32769 0000.0000.0000 128.304 Supported Releases 10.2.0E or later spanning-tree bpdufilter Enables or disables BPDU filtering on an interface. Syntax spanning-tree bpdufilter {enable | disable - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 192
port receives a BPDU, it is placed in the Error-Disabled state as a protective measure. OS10(conf-if-eth1/1/4)# spanning-tree bpduguard enable Supported Releases 10.2.0E or later spanning-tree guard Enables or disables loop guard or root guard on an interface. Syntax Parameters spanning-tree - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 193
new mode. You can also change to RSTP/MST mode. OS10(config)# spanning-tree mode rstp Example (MST) OS10(config)# spanning-tree mode mst Supported Releases 10.2.0E or later spanning-tree port Sets the port type as the EdgePort. Syntax spanning-tree port type edge Parameters None Default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 194
The media speed of a LAN interface determines the STP port path cost default value. OS10(conf-if-eth1/1/4)# spanning-tree vlan 10 cost 1000 Supported Releases 10.2.0E or later spanning-tree vlan forward-time Configures a time interval for the interface to wait in Blocking state or Learning state - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 195
to 40). Default 20 seconds Command Mode CONFIGURATION Usage Information None Example OS10(config)# spanning-tree vlan 10 max-age 10 Supported Releases 10.2.0E or later spanning-tree vlan priority Sets the priority value for RPVST+. Syntax Parameters Default Command Mode Usage Information - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 196
128 INTERFACE Breaks the tie between the two bridges which compete for root bridge. OS10(conf-if-eth1/1/4)# spanning-tree vlan 10 priority 16 Supported Releases 10.2.0E or later spanning-tree vlan root Designates a device as primary or secondary root bridge. Syntax spanning-tree vlan vlan-id - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 197
• Re-enable an interface in INTERFACE mode. no spanning-tree disable • Re-enable RSTP globally for all L2 interfaces in CONFIGURATION mode. no spanning-tree disable View all port participating in RSTP OS10# show spanning-tree Spanning tree enabled protocol rstp with force-version rstp Executing - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 198
ethernet1/1/23 128.348 128 200000000 BLK 0 0 0000.0000.0000 0.0 ethernet1/1/24 128.352 128 200000000 BLK 0 0 0000.0000.0000 0.0 ethernet1/1/25 128.356 128 200000000 BLK 0 0 0000.0000.0000 0.0 ethernet1/1/26 128.360 128 200000000 BLK 0 0 0000.0000.0000 0.0 ethernet1/1/27 128.364 128 200000000 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 199
Root ID Priority 32768, Address 90b1.1cf4.9b8a Root Bridge hello time 2, max age 20, forward delay 15 Bridge ID Priority 32768, Address 90b1.1cf4.9b8a We are the root Configured hello time 2, max age 20, forward delay 15 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 200
Root bridge selection RSTP determines the root bridge. Assign one bridge a lower priority to increase the likelihood that it is selected as the root bridge. • Assign a number as the bridge priority or designate it as the primary or secondary root in CONFIGURATION mode. Configure the priority value - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 201
supports BPDU filtering, BPDU guard, loop guard, and root guard STP extensions. BPDU filtering BPDU guard Root guard Loop guard Protects the network from unexpected flooding of BPDUs from an erroneous device. Enabling BPDU Filtering instructs Shutdown state after manual intervention. Avoids - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 202
violation :disable RootGuard: enable LoopGuard disable Bpdus (MRecords) sent 134, received 138 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ethernet1/1/4 128.272 128 500 BLK 500 32769 90b1.1cf4.a911 128.272 BPDU guard OS10(config)# interface ethernet 1/1/4 OS10( - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 203
all STP counters on the device per Ethernet interface or port-channel. OS10# clear spanning-tree counters interface port-channel 10 Supported Releases 10.2.0E or later show spanning-tree active Displays the RSTP configuration and information for RSTP-active interfaces. Syntax Parameters Default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 204
to forwarding state 1 Link type is point-to-point by default, auto PVST Simulation is enabled by default BPDU sent 3, received 7 Supported Releases 10.2.0E or later spanning-tree bpdufilter Enables or disables BPDU filtering on an interface. Syntax spanning-tree bpdufilter {enable | disable - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 205
If the port receives a BPDU, it is placed in the Error-Disabled state as a protective measure. OS10(conf-if-eth1/1/4)# spanning-tree bpduguard enable Supported Releases 10.2.0E or later spanning-tree guard Enables or disables loop guard or root guard on an interface. Syntax spanning-tree guard - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 206
new mode. You can also change to RSTP/MST mode. OS10(config)# spanning-tree mode rstp Example (MST) OS10(config)# spanning-tree mode mst Supported Releases 10.2.0E or later spanning-tree port Sets the port type as the EdgePort. Syntax spanning-tree port type edge Parameters None Default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 207
-age seconds seconds - Enter a maximum age value in seconds (6 to 40). 20 seconds CONFIGURATION None OS10(config)# spanning-tree rstp max-age 10 Supported Releases 10.2.0E or later spanning-tree rstp Sets the priority value for RSTP. Syntax spanning-tree rspt priority priority value Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 208
the root bridge. A lower priority value increases the probability of the bridge becoming a root bridge. OS10(config)# spanning-tree rstp priority 200 Supported Releases 10.2.0E or later Virtual LANs VLAN segments a single flat L2 broadcast domain into multiple logical L2 networks. Each VLAN is - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 209
Create or remove VLANs You can create VLANs and add physical interfaces or port-channel (LAG) interfaces to the VLAN as tagged or untagged members. You can add an Ethernet interface as a trunk port or as an access port, but it cannot be added as both at the same time. Multiple non-default vlans - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 210
ARP type: ARPA, ARP Timeout: 240 Last clearing of "show interface" counters Queueing strategy: fifo Time since last interface status change: Vlan 200 is up, line protocol is up Address is , Current address is Interface index is 69209064 Internet address is not set MTU 1532 bytes LineSpeed auto - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 211
Trunk mode A trunk port can be a member of multiple VLANs set up on an interface. A trunk port can transmit traffic for all VLANs. To transmit traffic on a trunk port with multiple VLANs, OS10 uses tagging or the 802.1q encapsulation method. 1 Configure a port in INTERFACE mode. interface ethernet - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 212
View VLAN configuration OS10(conf-if-vl-200)# do show interface vlan Vlan 1 is up, line protocol is up Address is , Current address is Interface index is 69208865 Internet address is not set MTU 1532 bytes LineSpeed auto Flowcontrol rx off tx off ARP type: ARPA, ARP Timeout: 240 Last clearing of " - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 213
320 up View interface VLAN configuration T Po40 A Eth1/1/31 T Eth1/1/25:4 1/1/32 T Po40 A Eth1/1/3:1 OS10# show interface vlan Vlan 1 is up, line protocol is up Address is , Current address is Interface index is 69208865 Internet address is not set MTU 1532 bytes LineSpeed auto Flowcontrol rx off - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 214
interface vlan vlan-id vlan-id - Enter the VLAN ID number (1 to 4094). VLAN 1 CONFIGURATION FTP, TFTP, MAC ACLs, and SNMP operations are not supported - IP ACLs are supported on VLANs only. The no version of this command deletes the interface. OS10(config)# interface vlan 10 OS10(conf-if-vl-10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 215
Supported Releases 10.2.0E or later Port monitoring T Po40 A Eth1/1/3:1 Port monitoring enables mirroring of ingress or egress traffic of one port to another for analysis. A - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 216
ACL mode. The ACL rules describe the traffic you want to monitor. Flow monitoring is supported for IPv4 ACLs, IPv6 ACLs, and MAC ACLs. seq sequence-number {deny | permit helps network administrators monitor and analyze traffic to troubleshoot network problems in a time-saving and efficient way. In - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 217
restriction on the VLAN IDs used for the reserved remote-mirroring VLAN. Valid VLAN IDs are from 2 to 4094. The default VLAN ID is not supported. • In mirrored traffic, packets that have the same destination MAC address as an intermediate or destination device in the path used by the reserved VLAN - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 218
functions as the destination port. • The reserved VLAN used to transport mirrored traffic must be a L2 VLAN - L3 VLANs are not supported. Configure remote port mirroring Remote port mirroring requires a source session (monitored ports on different source network devices), a reserved tagged VLAN - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 219
the value to the default. OS10(conf-mon-local-10)# destination interface port-channel 10 OS10(conf-mon-rspan-source-3)# destination remote-vlan 20 Supported Releases 10.2.0E or later flow-based Enables flow-based monitoring. The monitoring session can be one of the following: local, RPM. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 220
OS10# show monitor session all S.Id Source Destination Dir SrcIP DstIP DSCP TTL State Reason 1 ethernet1/1/6 port-channel10 rx N/A N/A N/A N/A true Is UP Supported Releases 10.2.0E or later shut Disables the monitoring session. The monitoring session can be one of the following: local, RPM - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 221
)# monitor session 1 OS10(conf-mon-local-1)# no shut OS10(config)# monitor session 5 type rspan-source OS10(conf-mon-rspan-source-5)# no shut Supported Releases 10.2.0E or later source (Port Monitoring) Configures a source for port monitoring. The monitoring session can be one of the following - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 222
same autonomous system First (OSPF) area using link-state advertisements (LSAs). OS10 supports up to 10,000 OSPF routes for OSPFv2 to designate up to 8,000 one network to another. An ISP uses a transit AS to sell transit service to a customer network. When BGP operates inside an AS - AS1 or AS2 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 223
AS. EBGP routers exchange information with other EBGP routers and IBGP routers to maintain connectivity and accessibility. Classless interdomain routing BGPv4 supports classless interdomain routing (CIDR) with aggregate routes and AS paths. CIDR defines a network using a prefix consisting of an IP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 224
, and notification messages to and from its peer. Peer templates Peer templates allow BGP neighbors to inherit the same outbound policies. Instead of manually configuring each neighbor with the same policy, you can create a peer group with a shared policy that applies to individual peers. A peer - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 225
per peer basis. The default is the IPv4 unicast routes. BGP session supports multiple address family interface (AFI) and sub address family interface (SAFI) is exchanged over the IPv4 peers and vice versa. BGP routers that support IPv6 can set up BGP sessions using IPv6 peers. If the existing BGP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 226
• A path with no AS_PATH configured has a path length of 0 • AS_CONFED_SET is not included in the AS_PATH length • AS_CONFED_SEQUENCE has a path length of 1 no matter how many ASs are in the AS_CONFED_SEQUENCE 4 Prefer the path with the lowest ORIGIN type-IGP is lower than EGP and EGP is lower than - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 227
Multiexit discriminators If two autonomous systems connect in more than one place, use a multiexit discriminator (MED) to assign a preference to a preferred path. MED is one of the criteria used to determine best path-other criteria may also impact selection. One AS assigns the MED a value. Other - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 228
The question mark (?) indicates an origin code of INCOMPLETE, and the lower case letter (i) indicates an origin code of IGP. Origin configuration OS10# show ip bgp BGP local RIB : Routes to be Added , Replaced , Withdrawn BGP local router ID is 30.1.1.1 Status codes: s suppressed, S stale, d - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 229
the bestpath as-path multipath-relax command at the same time, an error message displays-only enable one command at a time. More path support More path (Add-Path) reduces convergence times by advertising multiple paths to its peers for the same address prefix without replacing existing paths with - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 230
4-byte AS number configurations by default. The 4-byte support is advertised as a new BGP capability - 4-BYTE-AS, in the OPEN message. A BGP speaker that advertises 4-Byte-AS capability to a peer, and receives the same - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 231
• reuse = 750 • suppress = 2000 Timers • keepalive = 60 seconds • holdtime = 180 seconds Add-path Disabled Enable BGP BGP is disabled by default. The system supports one AS number - you must assign an AS number to your device. To establish BGP sessions and route traffic, configure at least one - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 232
BGP mode from CONFIGURATION mode (1 to 65535 for 2-byte, 1 to 4294967295 for 4byte). Only one AS number is supported per system. If you enter a 4-byte AS number, 4-byte AS support is enabled automatically. router bgp as-number 2 Enter a neighbor in ROUTER-BGP mode. neighbor ip-address 3 Add a remote - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 233
-source Loopback loopback0 no shutdown ! neighbor 192.168.12.2 remote-as 65123 update-source Loopback loopback0 no shutdown ! Configure Dual Stack OS10 supports dual stack for BGPv4 and BGPv6. Dual stack BGP allows simultaneous exchange of same IPv4 or IPv6 prefixes through different IPv4 and IPv6 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 234
template. Create a peer template before configuring any route policies for the template. NOTE: An outbound filter policy, distribute list or route map, is not supported on a peer group member. 1 Enable BGP, and assign the AS number to the local BGP speaker in CONFIGURATION mode, from 1 to 65535 for - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 235
between advertisement runs is 30 seconds For address family: Unicast BGP neighbor is ebgppg, peer-group external Update packing has 4_OCTET_AS support enabled Number of peers in this group 1 Peer-group members: View running configuration OS10(config-router-neighbor)# do show running-configuration - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 236
Received 23 messages 1 opens, 0 notifications, 1 updates 21 keepalives, 0 route refresh requests Sent 21 messages 1 opens, 0 notifications, 0 updates 20 keepalives, 0 route refresh requests Minimum time between advertisement runs is 30 seconds Minimum time before advertisements start is 0 seconds - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 237
Fast external fallover is enabled by default. To disable or re-enable it, use the [no] fast-external-fallover command. For the fast-external-fallover command to take effect on an established BGP session, you must reset the session using the clear ip bgp {* | peer-ipv4-address | peer-ipv6-address} - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 238
, see Peer templates. If you do not configure a BGP device in Peer-Listening mode, a session with a dynamic peer comes up. Passwords are not supported on BGPv4/v6 dynamic peers. Configure passive peering OS10(config)# router bgp 10 OS10(conf-router-bgp-10)# template bgppg OS10(conf-router-template - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 239
2 Enter a local-as number for the peer, and the AS values not prepended to announcements from the neighbors in ROUTERNEIGHBOR mode (1 to 4294967295). local-as as number [no prepend] 3 Return to ROUTER-BGP mode. exit 4 Enter a template name to assign to the peer-groups in ROUTER-BGP mode (up to 16 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 240
neighbor 17.1.1.2 remote-as 102 no shutdown ! address-family ipv4 unicast allowas-in 4 Show IP BGP OS10(config)# router bgp 100 OS10(config-router-bgp-100)# neighbor 172:16:1::2 OS10(config-router-neighbor)# remote-as 100 OS10(config-router-neighbor)# no shutdown OS10(config-router-neighbor)# - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 241
1 Assign an AS number in CONFIGURATION mode. router bgp as-number 2 Enter a neighbor and IP address (A.B.C.D) in ROUTER-BGP mode. neighbor ip-address 3 Enter Address Family mode in ROUTER-NEIGHBOR mode. address-family {[ipv4 | ipv6] [unicast]) 4 Allow the specified neighbor to send or receive - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 242
4 Enter the neighbor to apply the route map configuration in ROUTER-BGP mode. neighbor {ip-address} 5 Apply the route map to the neighbor's incoming or outgoing routes in ROUTER-BGP-NEIGHBOR-AF mode. route-map map-name {in | out) 6 Enter the peer group to apply the route map configuration in ROUTER- - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 243
OS10(config-router-bgp-10)# template zanzibar OS10(config-router-template)# weight 200 Enable multipath You can have one path to a destination by default, and enable multipath to allow up to 64 parallel paths to a destination. The show ip bgp network command includes multipath information for that - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 244
Configure clusters of routers where one router is a concentration router and the others are clients who receive their updates from the concentration router. 1 Assign an ID to a router reflector cluster in ROUTER-BGP mode. You can have multiple clusters in an AS. cluster-id cluster-id 2 Assign a - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 245
byte, 1 to 4294967295 for 4-byte. All Confederation routers must be either 4 bytes or 2 bytes. You cannot have a mix of router ASN support. confederation peers as-number [... as-number] Configure BGP confederations OS10(config)# router bgp 65501 OS10(conf-router-bgp-65501)# confederation identifier - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 246
Route dampening When EBGP routes become unavailable, they "flap" and the router issues both WITHDRAWN and UPDATE notices. A flap occurs when a route is withdrawn, readvertised after being withdrawn, or has an attribute change. The constant router reaction to the WITHDRAWN and UPDATE notices causes - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 247
request to the neighbor and receives all the peer's updates. To use soft reconfiguration, or soft reset without preconfiguration, both BGP peers must support the soft route refresh capability. The soft route refresh advertises in the OPEN message sent when the peers establish a TCP session. To - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 248
neighbor, use the no activate command. Example OS10(conf-router-neighbor)# address-family ipv4 unicast OS10(conf-router-bgp-neighbor-af)# activate Supported Releases 10.2.0E or later add-path Allows the system to advertise multiple paths for the same destination without replacing previous paths - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 249
64 Example (IPv6) OS10(conf-router-bgpv6-af)# add-path both 64 Example (Receive) OS10(conf-router-bgpv6-af)# add-path receive Supported Releases 10.2.0E or later address-family Enters global address family configuration mode for the IP address family. Syntax Parameters address-family {[ipv4 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 250
mode. The no version of this command disables the advertisement-start time interval. Example OS10(conf-router-neighbor)# advertisement-start 30 Supported Releases 10.3.0E or later aggregate-address Summarizes a range of prefixes to minimize the number of entries in the routing table. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 251
the best path. The no version of this command resets the value to the default. OS10(conf-router-bgp-10)# always-compare-med Supported Releases 10.2.0E or later bestpath as-path Configures the AS path selection criteria for best path computation. Syntax Parameters bestpath as-path {ignore - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 252
ID for multiple paths. The no version of this command resets the value to the default. Example OS10(conf-router-bgp-2)# bestpath router-id ignore Supported Releases 10.3.0E or later clear ip bgp Resets BGP IPv4 or IPv6 neighbor sessions. Syntax clear ip bgp {ipv4-address | ipv6-address - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 253
Usage Information Example Not configured EXEC To reset BGP IPv4 or IPv6 neighbor sessions, use this command. OS10# clear ip bgp 1.1.15.4 Supported Releases 10.3.0E or later clear ip bgp * Resets BGP sessions. The soft parameter (BGP soft reconfiguration) clears policies without resetting the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 254
The no version of this command disables route reflection in a cluster. Example OS10(conf-router-bgp-2)# client-to-client reflection Supported Releases 10.2.0E or later bgp connection-retry-timer Configures a peer connection retry timer. Syntax Parameters Default Command Mode Usage Information - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 255
, an integer displays. The no version of this command resets the value to the default. OS10(conf-router-bgp-10)# cluster-id 3.3.3.3 Supported Releases 10.3.0E or later bgp dampening Enables BGP route-flap dampening and configures the dampening parameters. Syntax bgp dampening [half-life | reuse - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 256
the default metric value. OS10(conf-router-bgpv4-af)# default-metric 60 Example (IPv6) OS10(conf-router-bgpv6-af)# default-metric 60 Supported Releases 10.3.0E or later bgp default local-preference Changes the default local preference value for routes exchanged between internal BGP peers - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 257
indirectly connected are not valid for best path selection. The no version of this command removes multihop session. OS10(conf-router-neighbor)# ebgp-multihop 2 Supported Releases 10.3.0E or later enforce-first-as Enforces the first AS in the AS path of the route received from an external border - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 258
unreachability or link failure is detected. This only applies after you manually reset all existing BGP sessions. For the configuration to take effect, external fallover. OS10(conf-router-bgp-10)# fast-external-fallover Supported Releases 10.3.0E or later inherit template Configures a peer group - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 259
, use the show bgp config command. The no version of this command disables the feature. OS10(conf-router-bgp-10)# log-neighbor-changes Supported Releases 10.3.0E or later maximum-paths Configures the maximum number of equal-cost paths for load sharing. Syntax maximum-paths [ebgp number | ibgp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 260
The no version of this command resets the value to the default. OS10(conf-router-bgp-neighbor-af)# maximum-prefix 20 100 warning-only Supported Releases 10.3.0E or later neighbor Creates a remote peer for the BGP neighbor and enters BGP Neighbor mode. Syntax Parameters Default Command Mode Usage - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 261
routes to IBGP peers. The no version of this command disables the nexthop calculation. OS10(conf-router-neighbor-af)# next-hop-self Supported Releases 10.3.0E or later non-deterministic-med Compares paths in the order they arrive. Syntax Parameters Default Command Mode Usage Information Example - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 262
outbound optimization. OS10(conf-router-bgp-10)# outbound-optimization Supported Releases 10.3.0E or later password Configures a password OSPF process (1 to 65535). • static - Enter to redistribute manually configured routes. Default Command Mode Usage Information Example (Connected) Disabled - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 263
removes all clients of a route reflector-the router no longer functions as a route reflector. Example OS10(conf-router-template)# route-reflector-client Supported Releases 10.3.0E or later router bgp Enables BGP and assigns an AS number to the local BGP speaker. Syntax Parameters router bgp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 264
. The no version of this command resets the value to the default. OS10(conf-router-bgp-10)# router-id 10.10.10.40 Supported Releases 10.3.0E or later send-community Sends a community attribute to a BGP neighbor or peer group. Syntax send-community {extended | standard} Parameters • extended - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 265
102)# neighbor 32::1 OS10(conf-router-neighbor)# address-family ipv6 unicast OS10(conf-router-bgp-neighbor-af)# no sender-side-loop-detection Supported Releases 10.3.0E or later show ip bgp Displays information that BGP neighbors exchange. Syntax Parameters Default Command Mode Usage Information - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 266
00 800 9 8 i *> 3.1.5.0/24 80.1.1.2 1 00:00:11 00:00:00 800 9 8 i *> 3.1.6.0/24 80.1.1.2 1 00:00:11 00:00:00 800 9 8 i Total number of prefixes: 5 Supported Releases 10.3.0E or later show ip bgp ipv4 unicast Displays route information for BGP IPv4 routes. Syntax Parameters show ip bgp ipv4 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 267
bgp ipv4 unicast summary BGP router identifier 80.1.1.1 local AS number 102 Neighbor AS MsgRcvd MsgSent Up/Down State/Pfx 80.1.1.2 800 8 4 00:01:10 5 Supported Releases 10.3.0E or later show ip bgp ipv6 unicast Displays route information for BGP IPv6 routes. Syntax show ip bgp ipv6 unicast - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 268
Command Mode Usage Information EXEC • BGP neighbor - Displays the BGP neighbor address and its AS number. The last phrase in the line indicates whether the link between the BGP router and its neighbor is an external or internal one. If they are located in the same AS, the link is internal; - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 269
Example advertisedroutes OS10# show ip bgp ipv6 unicast neighbors 192:168:1::2 advertised-routes BGP local router ID is 100.1.1.1 Status codes: s suppressed, S stale, d dampened, h history, * valid, > best Origin codes: i - IGP, e - EGP, ? - incomplete Network Next Hop Metric LocPrf Weight - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 270
you do not enable the peer group. If you enable the peer group, this line does not display. • BGP version - Displays the BGP version supported. • For address family - Displays IPv4 unicast as the address family. • BGP neighbor - Displays the name of the BGP neighbor. • Number of peers - Displays the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 271
. Syntax soft-reconfiguration inbound Parameters None Default Not configured Command Modes ROUTER-BGP-NEIGHBOR-AF Usage Information This command is not supported on a peer-group level. To enable soft-reconfiguration for peers in a peer-group, this command must be enabled at a per-peer - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 272
values negotiate from peers. The no version of this command resets the value to the default. OS10(conf-router-bgp)# timers 30 90 Supported Releases 10.3.0E or later weight Assigns a default weight for routes from the neighbor interfaces. Syntax weight number Parameters number-Enter a number - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 273
Equal cost multi-path ECMP is a routing technique where next-hop packet forwarding to a single destination occurs over multiple best paths. OS10 uses a hashing algorithm to determine the next-hop when you enable ECMP. The hashing algorithm makes hashing decisions based on values in various packet - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 274
across the members. The no version of this command returns the value to the default. Example OS10(config)# hash-algorithm lac crc Supported Releases 10.3.0E or later link-bundle-utilization trigger-threshold Configures a threshold value to trigger monitoring of traffic distribution on an ECMP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 275
) OS10(config)# load-balancing ingress-port enable Example (IP Selection) OS10(config)# load-balancing ip-selection destination-ip source-ip Supported Releases 10.2.0E or later show hash-algorithm Displays the hash-algorithm information. Syntax Parameters show hash-algorithm None Layer 3 275 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 276
Mode Usage Information Example Not configured EXEC None OS10# show hash-algorithm EcmpAlgo - crc LabAlgo - xor Supported Releases 10.3.0E or later IPv4 routing OS10 supports IPv4 addressing including variable-length subnetting mask (VLSM), address resolution protocol (ARP), static routing, and - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 277
0 packets/sec, 0% of line rate Time since last interface status change: 3 weeks 1 day 20:54:37 Configure static routing You can configure a manual or static route for OSPF. • Configure a static route in CONFIGURATION mode. ip route ip-prefix/mask {next-hop | interface interface [route-preference - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 278
in dotted decimal format-A.B.C.D. • mac address-MAC address in nnnn.nnnn.nnnn format These entries do not age, and you can only remove them manually. To remove a static ARP entry, use the no arp ip-address command. Configure static ARP entries OS10(config)# interface ethernet 1/1/6 OS10(conf-if-eth1 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 279
The no version of this command disables the DHCP operations on the interface. OS10(config)# interface mgmt 1/1/1 OS10(conf-if-ma-1/1/1)# ip address dhcp Supported Releases 10.3.0E or later ip arp Configures static ARP and maps the IP address of the neighbor to a MAC address. Syntax ip arp mac - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 280
also invalid. The no version of this command disables IP ARP configuration. OS10(conf-if-eth1/1/6)# ip arp 10.1.1.5 08:00:20:b7:bd:32 Supported Releases 10.2.0E or later ip route Assigns a static route on the network device. Syntax ip route ip-prefix mask {next-hop | interface interface [route - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 281
192.168.1.1 - 00:01:e8:8b:39:43 - Vl 100 CP Internet 192.168.1.2 99 00:01:e8:8b:3c:01 Te 1/0 Vl 100 CP Supported Releases 10.2.0E or later show ip route Displays IP route information. Syntax Parameters show ip route [all | bgp | connected | ospf process-id | static | ip - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 282
of hosts in the network when an organization changes its service provider. MOVE to DHCP topic As an alternative to stateless message is received by default. The system manipulation of IPv6 stateless autoconfiguration supports the router side only. Neighbor discovery (ND) messages advertise so the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 283
The router redirect functionality in the Neighbor Discovery protocol (NDP) is similar to IPv4 router redirect messages. NDP uses ICMPv6 redirect messages (Type 137) to inform nodes that a better router exists on the link. IPv6 addresses An IPv6 address consists of a 48-bit global routing prefix, - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 284
is enabled (ipv6 address link-local command) To remove all IPv6 addresses from an interface, enter the no ipv6 address autoconfig command. You can manually disable and reenable IPv6 processing on an interface configured with an IPv6 address (no ipv6 enable and ipv6 enable commands). To re-enable - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 285
. Default Command Mode Usage Information Example Not configured EXEC This command does not remove the static routes from the routing table. OS10# clear ipv6 route * Supported Releases 10.3.0E or later Layer 3 285 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 286
OS10(config)# interface ethernet 1/1/1 OS10(conf-if-eth1/1/1)# no switchport OS10(conf-if-eth1/1/1)# ipv6 address autoconfig OS10(conf-if-eth1/1/1)# Supported Releases 10.3.0E or later ipv6 address dhcp Enables DHCP client operations on the interface. Syntax ipv6 address dhcp Parameters None - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 287
you do not assign an IP address to a peer interface, you must manually ping the peer to resolve the neighbor information. The no version of OS10(config)# ipv6 route 2111:dddd:0eee::22/128 2001:db86:0fff::2 Supported Releases 10.2.0E or later show ipv6 route Displays IPv6 routes. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 288
NSSA External-2 0 Ospf External-1 0 Ospf External-2 0 Bgp Internal 0 Bgp External 0 Ospf Intra-area 0 Total 0 Non-Active Routes 0 0 0 0 0 0 0 0 0 0 0 0 0 Supported Releases 10.2.0E or later Open shortest path first OSPF routing is a link-state routing protocol that allows sending of - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 289
Areas allow you to further organize routers within the AS with one or more areas within the AS. Areas are valuable in that they allow subnetworks to hide within the AS-minimizing the size of the routing tables on all routers. An area within the AS may not see the details of another area's topology. - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 290
. Each router has a unique ID, written in decimal format-A.B.C.D. You do not have to associate the router ID with a valid IP address. To make troubleshooting easier, ensure the router ID is identical to the router's IP address. Backbone router A backbone router (BR) is part of the OSPF Backbone - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 291
Designated and backup designated routers OSPF elects a designated router (DR) and a backup designated router (BDR). The DR is responsible for generating LSAs for the entire multiaccess network. Designated routers allow a reduction in network traffic and in the size of the topological database. - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 292
second highest priority is the BDR. Priority rates from 0 to 255, with 255 as the highest number with the highest priority. OSPF route limit OS10 supports up to 16,000 OSPF routes. Within this range, the only restriction is on intra-area routes that scale only up to 100 routes. Other - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 293
OSPFv2 OSPFv2 supports IPv4 address families. OSPFv2 routers initially exchange hello messages to set up adjacencies with neighbor routers. The hello process establishes adjacencies between routers of the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 294
Assign router identifier For managing and troubleshooting purposes, you can assign a router ID for the .1.5 View OSPFv2 status OS10# show ip ospf 10 Routing Process ospf 10 with ID 10.10.1.5 Supports only single TOS (TOS0) routes It is an Autonomous System Boundary Router It is Flooding according to - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 295
updates. This impacts CPU utilization and may impact adjacency stability in larger topologies. NOTE: Select the higher convergence levels only after checking with Dell Technical Support. Layer 3 295 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 296
-65535)# fast-converge 1 View fast convergence OS10(conf-router-ospf-65535)# do show ip ospf Routing Process ospf 65535 with ID 99.99.99.99 Supports only single TOS (TOS0) routes It is an Autonomous System Border Router It is an Area Border Router It is Flooding according to RFC 2328 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 297
5 Change the priority of the interface, which determines the DR for the OSPF broadcast network in INTERFACE mode, from 0 to 255. The default priority of the interface is 1. ip ospf priority number 6 Change the retransmission interval time, in seconds, between LSAs in INTERFACE mode, from 1 to 3600. - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 298
a grace LSA to all neighbors. In response, the helper router enters helper mode and sends an acknowledgement back to the restarting device. OS10 supports graceful restart helper mode. Use the graceful-restart role helper-only command to enable the helper mode in the ROUTER OSPF mode. OS10(config - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 299
the OSPF routes included in the OSPF database? • Are the OSPF routes included in the routing table in addition to the OSPF database? Troubleshooting OSPF with show commands • View a summary of all OSPF process IDs enabled in EXEC mode. show running-configuration ospf • View summary information of - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 300
or bandwidth. The no version of this command resets the value to the default. OS10(conf-router-ospf-10)# area 10.10.1.5 default-cost 10 Supported Releases 10.2.0E or later area nssa Defines an area as a NSSA. Syntax Parameters area area-id nssa [default-information-originate | no-redistribution - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 301
configured ROUTER-OSPF The no version of this command disables the route summarizations. OS10(conf-router-ospf-10)# area 0 range 10.1.1.4/8 no-advertise Supported Releases 10.2.0E or later area stub Defines an area as the OSPF stub area. Syntax area area-id stub [no-summary] Parameters • area - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 302
this command resets the value to the default. OS10(config)# router ospf 10 OS10(conf-router-ospf-10)# auto-cost reference-bandwidth 150 Supported Releases 10.2.0E or later clear ip ospf process Clears all OSPF routing tables. Syntax clear ip ospf {instance-number} process Parameters instance - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 303
no version of this command disables the helper mode. Example OS10(config)# router ospf 10 OS10(conf-router-ospf-10)# graceful-restart role helper-only Supported Releases 10.3.0E or later ip ospf area Attaches an interface to an OSPF area. Syntax Parameters ip ospf process-id area area-id - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 304
vendors to ensure that all routers use the same cost. If you manually configure the cost, the calculated cost based on the reference bandwidth does )# interface vlan 10 OS10(conf-if-vl-1)# ip ospf cost 10 Supported Releases 10.2.0E or later ip ospf dead-interval Sets the time interval since - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 305
to the default. OS10(conf-if-vl-10)# ip ospf hello-interval 30 Supported Releases 10.2.0E or later ip ospf message-digest-key Enables OSPF MD5 OS10(conf-if-eth1/1/1)# ip ospf message-digest-key 2 md5 sample12345 Supported Releases 10.3.0E or later ip ospf mtu-ignore Disables OSPF MTU - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 306
does not establish. The no version of this command enables the IP OSPF mtu-ignore configuration. OS10(conf-if-vl-10)# ip ospf mtu-ignore Supported Releases 10.2.0E or later ip ospf network Sets the network type for the interface. Syntax ip ospf network {point-to-point | broadcast} Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 307
avoid unnecessary retransmission. The no version of this command resets the value to the default. OS10(conf-if-eth1/1/6)# ip ospf retransmit-interval 20 Supported Releases 10.2.0E or later ip ospf transmit-delay Sets the estimated time required to send a link state update packet on the interface - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 308
of this command resets the value to the default. Example OS10(config)# router ospf 10 OS10(conf-router-ospf-10)# maximum-paths 1 Supported Releases 10.2.0E or later redistribute Redistributes information from another routing protocol or routing instance to the OSPFv2 process. Syntax Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 309
of this command disables the router ID configuration. Example OS10(config)# router ospf 10 OS10(conf-router-ospf-10)# router-id 10.10.1.5 Supported Releases 10.2.0E or later router ospf Enters Router OSPF mode and configures an OSPF instance. Syntax Parameters Default Command Mode Usage - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 310
interface in this area is 3 SPF algorithm executed 38 times Area ranges are Supported Releases 10.2.0E or later show ip ospf asbr Displays all the ASBR visible configured Command Mode EXEC Usage Information You can isolate problems with external routes. External OSPF routes are calculated by - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 311
111.2.1.1 112.2.1.1 112.2.1.1 Age 1287 1458 1458 1372 1372 Seq# 0x80000008 0x80000008 0x80000008 0x80000008 0x80000008 Summary Network (Area 0.0.0.0) Supported Releases 10.2.0E or later Checksum 0x9bf2 0x515a 0x5552 0x0485 0xbab2 0xbeaa Checksum 0xd2b1 0x1b8f 0x198f 0x287c 0x267c Link count - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 312
: Summary Asbr Link State ID: 8.1.1.1 Advertising Router: 2.2.2.2 LS Seq Number: 0x80000001 Checksum: 0xB595 Length: 28 Network Mask: /0 TOS: 0 Metric: 0 Supported Releases 10.2.0E or later show ip ospf database external Displays information about the AS external (Type 5) LSAs. Syntax Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 313
Advertising Router: 112.2.1.1 LS Seq Number: 0x80000008 Checksum: 0xd2b1 Length: 32 Network Mask: /24 Attached Router: 111.2.1.1 Attached Router: 112.2.1.1 Supported Releases 10.2.0E or later show ip ospf database nssa external Displays information about the NSSA-External (Type 7) LSA. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 314
Usage Information • LS Age - Displays the LS age. • Options - Displays the optional capabilities available on the router. • LS Type - Displays the Link State type. • Link State ID - Identifies the router ID. • Advertising Router - Identifies the advertising router's ID. • LS Seq Number - Identifies - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 315
LS Seq Number: 0x80000001 Checksum: 0xA303 Length: 36 Network Mask: /24 Metric Type: 2 TOS: 0 Metric: 20 Forward Address: 0.0.0.0 External Route Tag: 0 Supported Releases 10.2.0E or later show ip ospf database opaque-area Displays information about the opaque-area (Type 10) LSA. Syntax show ip - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 316
Link State ID: 8.1.1.2 Advertising Router: 2.2.2.2 LS Seq Number: 0x80000008 Checksum: 0x83B8 Length: 28 Opaque Type: 8 Opaque ID: 65794 !! ! Supported Releases 10.2.0E or later show ip ospf database opaque-as Displays information about the opaque-as (Type 11) LSAs. Syntax Parameters Default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 317
-9 Link Local Opaque Link State ID: 8.1.1.1 Advertising Router: 2.2.2.2 LS Seq Number: 0x80000007 Checksum: 0x9DA1 Length: 28 Opaque Type: 8 Opaque ID: 65793 Supported Releases 10.2.0E or later show ip ospf database router Displays information about the router (Type 1) LSA. Syntax show ip ospf - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 318
Transit Network (Link ID) Designated Router address: 111.2.1.1 (Link Data) Router Interface address: 111.2.1.1 Number of TOS metric: 0 TOS 0 Metric: 1 Supported Releases 10.2.0E or later show ip ospf database summary Displays the network summary (Type 3) LSA routing information. Syntax show ip - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 319
Link State ID: 115.1.1.0 Advertising Router: 111.111.111.1 LS Seq Number: 0x800001e8 Checksum: 0x4a67 Length: 28 Network Mask: /24 TOS: 0 Metric: 0 Supported Releases 10.2.0E or later show ip ospf interface Displays the configured OSPF interfaces. You must enable OSPF to display output. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 320
110.1.1.0 1 0.0.0.0 intra-area 111.1.1.0 1 0.0.0.0 intra-area 111.2.1.0 1 0.0.0.0 intra-area Interface vlan3050 vlan3051 vlan3053 Area 0.0.0.0 0.0.0.0 0.0.0.0 Type Supported Releases 10.2.0E or later show ip ospf statistics Displays OSPF traffic statistics. Syntax • show ip ospf - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 321
Cost 1 1 1 2 2 Nexthop 111.1.1.2 111.2.1.2 110.1.1.2 110.1.1.2 110.1.1.2 Interface Vl 3051 Vl 3053 Vl 3050 Vl 3050 Vl 3050 Area 0 0 0 0 0 Supported Releases 10.2.0E or later summary-address Configures a summary address for an ASBR to advertise one external route as an aggregate, for all - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 322
of this command resets the value to the default. Example OS10(config)# router ospf 10 OS10(conf-router-ospf-10)# timers lsa arrival 2000 Supported Releases 10.2.0E or later timers throttle lsa all Configures the LSA transmit intervals. Syntax Parameters timers lsa all [start-interval | hold - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 323
OSPFv3 OSPFv3 is an IPv6 link-state routing protocol that supports IPv6 unicast address families (AFs). OSPFv3 is disabled by default. You must configure at least one interface, either physical or loopback. The OSPF process automatically - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 324
Min LSA hold time 0 msec, Max LSA wait time 0 msec Number of area in this router is 2, normal 2 stub 0 nssa Area (0.0.0.0) Number of interface in this area is 1 SPF algorithm executed 42 times Area (0.0.0.1) Number of interface in this area is 1 SPF algorithm executed 42 times Configure Stub Areas - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 325
Link (Type-8) Link States (Area 0.0.0.2) ADV Router Age Seq# Link ID Interface 199.205.134.103 42 0x80000001 12 ethernet1/1/3 202.254.156.15 54 0x80000001 12 ethernet1/1/3 Enable Passive Interfaces A passive interface is one that does not send or receive routing information. - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 326
the OSPF routes included in the OSPF database? • Are the OSPF routes included in the routing table in addition to the OSPF database? Troubleshooting OSPFv3 with show Commands • View a summary of all OSPF process IDs enabled in EXEC mode. show running-configuration ospfv3 • View summary information - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 327
The no version of this command deletes a stub area. OS10(config)# router ospfv3 10 OS10(conf-router-ospfv3-10)# area 10.10.1.5 stub Supported Releases 10.3.0E or later auto-cost reference-bandwidth Calculates default metrics for the interface based on the configured auto-cost reference bandwidth - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 328
command disables the distribution of default route. Example OS10(config)# router ospfv3 100 OS10(config-router-ospfv3-100)# default-information originate always Supported Releases 10.3.0E or later ipv6 ospf area Attaches an interface to an OSPF area. Syntax ipv6 ospf process-id area area-id - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 329
this command removes the IPv6 OSPF dead-interval configuration. OS10(config)# interface vlan 10 OS10(conf-if-vl-10)# ipv6 ospf dead-interval 10 Supported Releases 10.3.0E or later ipv6 ospf hello-interval Sets the time interval between hello packets sent on an interface. Syntax ipv6 ospf hello - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 330
of the this command disables the Passive interface configuration. Example OS10(config)# interface ethernet 1/1/6 OS10(conf-if-eth1/1/6)# ipv6 ospf passive Supported Releases 10.3.0E or later ipv6 ospf priority Sets the priority of the interface to determine the designated router for the OSPFv3 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 331
command resets the value to the default. Example OS10(config)# router ospfv3 100 OS10(config-router-ospfv3-100)# log-adjacency-changes Supported Releases 10.3.0E or later maximum-paths Enables forwarding of packets over multiple paths. Syntax Parameters Default Command Mode Usage Information - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 332
command disables the router ID configuration. Example OS10(config)# router ospfv3 10 OS10(config-router-ospfv3-100)# router-id 10.10.1.5 Supported Releases 10.3.0E or later router ospfv3 Enters Router OSPFv3 mode and configures an OSPFv3 instance. Syntax Parameters Default Command Mode Usage - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 333
msec Number of area in this router is 1, normal 1 stub 0 nssa Area (0.0.0.0) Number of interface in this area is 1 SPF algorithm executed 3 times Supported Releases 10.3.0E or later show ipv6 ospf database Displays all LSA information. You must enable OSPFv3 to generate output. Syntax show ipv6 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 334
configured, Hello 10, Dead 40, Wait 40, Retransmit 5 Neighbor Count is 1, Adjacent neighbor count is 1 Adjacent with neighbor 2.2.2.2(Designated Router) Supported Releases 10.3.0E or later show ipv6 ospf neighbor Displays a list of OSPFv3 neighbors connected to the local router. Syntax show - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 335
2.2.2.2 1 Full/DR 00:00:30 5 ethernet1/1/1 Supported Releases 10.3.0E or later Object tracking manager Object tracking manager (OTM) allows you to track the link status of Layer 2 interfaces, and the reachability - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 336
Figure 3. Object tracking Interface tracking You can create an object that tracks the line-protocol state of a Layer 2 interface, and monitors its operational status (Up or Down). You can configure up to 500 objects. Each object is assigned a unique ID. The no version of this command deletes the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 337
• Loopback - Loopback interface identifier • mgmt - Management interface 1 Configure object tracking in CONFIGURATION mode from 1 to 500. track object-id 2 (Optional) Enter the interface object tracking on the line-protocol state of a Layer 2 interface in OBJECT TRACKING mode. interface interface - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 338
in communicating a state change is specified in seconds. Object tracking As a client, VRRP can track up to 20 interface objects plus 12 tracked interfaces supported for each VRRP group. You can assign a unique priority-cost value from 1 to 254 to each tracked VRRP object or group interface. The - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 339
up to 180). Defaults Not configured Command Mode CONFIGURATION Usage Information None Example OS10(conf-track-100)# delay up 200 down 100 Supported Releases 10.3.0E or later interface line-protocol Configures an object to track a specific interface's line-protocol status. Syntax Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 340
- Enter the IPv4 host address. Not configured CONFIGURATION None OS10(config)# track 100 OS10(conf-track-100)# ip 10.10.10.1 reachability Supported Releases 10.3.0E or later ipv6 reachability Configures an object to track a specific next-hop host's reachability. Syntax ipv6 host-ip-address - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 341
2017-02-03T08:41:25Z1 2 ipv4-reachablity 1.1.1.1 DOWN 2017-02-03T08:41:43Z1 3 ipv6-reachablity 10::10 DOWN 2017-02-03T08:41:55Z1 Supported Releases 10.3.0E or later track Configures and manages tracked objects. Syntax track object-id Parameters object-id - Enter the object ID to track - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 342
Policy-based routing Policy-based routing (PBR) provides a mechanism to redirect IPv4 and IPv6 data packets based on the policies defined to override the switch's forwarding decisions based on the routing table. Policy-based route-maps A route-map is an ordered set of rules that control the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 343
Apply match parameters to IPv4 route-map OS10(conf-route-map)# route-map map1 OS10(conf-route-map)# match ip address acl5 Apply match and set parameters to IPv6 route-map OS10(conf-route-map)# route-map map1 OS10(conf-route-map)# match ipv6 address acl8 OS10(conf-route-map)# set ipv6 next-hop 20::20 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 344
] name-Enter the name of an access-list (up to 140 characters). Not configured ROUTE-MAP None OS10(conf-route-map)# match ip address acl1 Supported Releases 10.3.0E or later policy route-map Assigns a route-map for IPv4 or IPV6 policy-based routing to the interface. Syntax {ip | ipv6} policy - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 345
IPv6 address. Defaults Not configured Command Mode ROUTE-MAP Usage Information None Example OS10(conf-route-map)# set ip next-hop 10.10.10.10 Supported Releases 10.3.0E or later set next-hop track Sets the next-hop IPv4 or IPv6 address to track the PBR object. Syntax Parameters set - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 346
map-name - (Optional) Enter the name of a configured route map (up to 140 characters). None EXEC None OS10# show ip policy map-name Supported Releases 10.3.0E or later show route-map pbr-statistics Displays the current PBR statistics. Syntax show route-map [map-name] pbr-statistics Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 347
to transmit packets destined to the Internet. Router B receives and forwards packets on interface ethernet 1/1/5. Until Router A resumes operation, VRRP allows Router B to provide uninterrupted service to the users on the LAN segment accessing the Internet. Layer 3 347 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 348
Create virtual router VRRP uses the VRID to identify each virtual router configured. Before using VRRP, you must configure the interface with the primary IP address and enable it. • Create a virtual router for the interface with the VRRP identifier in INTERFACE mode (1 to 255). vrrp-group vrrp-id • - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 349
Set backup switches to VRRPv3 OS10_backup_switch1(config)# version 3 OS10_backup_switch2(config)# version 3 Virtual IP addresses Virtual routers contain virtual IP addresses configured for that VRRP group (VRID). A VRRP group does not transmit VRRP packets until you assign the virtual IP address to - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 350
interface ethernet1/1/2 switchport access vlan 1 no shutdown ! interface ethernet1/1/3 switchport access vlan 1 no shutdown ! interface ethernet1/1/4 switchport access vlan 1 --more-View VRRP information When the VRRP process completes initialization, the State field contains either master or - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 351
group with the same password. You must enable authentication with the same password or authentication is disabled. Authentication for VRRPv3 is not supported. 1 Create a virtual router for the interface with the VRRP identifier in INTERFACE mode (1 to 255). vrrp-group vrrp-id 2 Configure a simple - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 352
at Sep 24 07:17:45 2016 ! debug radius false snmp-server contact http://www.dell.com/support/softwarecontacts snmp-server location "United States" username admin password $6$q9QBeYjZ$jfxzVqGhkxX3smxJSH9DDz7/3OJc6m5wjF8nnLD7/VKx8SloIhp4NoGZs0I/ UNwh8WVuxwfd9q4pWIgNs5BKH. aaa authentication system - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 353
ethernet1/1/2 switchport access vlan 1 no shutdown Interface/object tracking You can monitor the state of any interface according to the virtual group. OS10 supports a maximum of 10 track groups and each track group can track a maximum of five interfaces. If the tracked interface goes down, the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 354
vlan 1 no shutdown ! interface ethernet1/1/6 switchport access vlan 1 no shutdown interface vlan1 no shutdown ! interface mgmt1/1/1 no shutdown ! support-assist ! track 10 track-interface ethernet1/1/1 VRRP commands advertise-interval Sets the time interval between VRRP advertisements. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 355
if the original Master recovers or the new Master fails. The no version of this command disables preemption. OS10(conf-eth1/1/5-vrid-254)# preempt Supported Releases 10.2.0E or later priority Assigns a VRRP priority value for the VRRP group. The VRRP protocol uses this value during the master - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 356
an error message. The no version of this command resets the value to the default (100). OS10(conf-eth1/1/5-vrid-254)# priority 200 Supported Releases 10.2.0E or later show vrrp Displays VRRP group information. Syntax show vrrp {brief | vrrp-id | ipv6 group-id} Parameters • brief - Displays - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 357
value to the default. OS10(conf-eth1/1/5-vrid-254)# track 400 Example (Priority Cost) OS10(conf-eth1/1/5-vrid-254)# track 400 priority-cost 20 Supported Releases 10.2.0E or later track interface Monitors an interface and lowers the priority value of the VRRP group on that interface, if disabled - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 358
The no version of this command deletes one or more virtual-addresses configured in the system. OS10(conf-eth1/1/5-vrid-254)# virtual address 10.1.1.15 Supported Releases 10.2.0E or later vrrp-group Assigns a VRRP group identification number to an IPv4 interface or VLAN Syntax vrrp-group vrrp-id - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 359
Parameters • 2 - Set to VRRP version 2. • both - Allows in-service migration from VRRP version 2 to VRRP version 3. • 3 - Set to VRRP version 3. Default Command disables the VRRP protocol version for the IPv4 group. OS10(config)# vrrp version both Supported Releases 10.2.0E or later Layer 3 359 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 360
6 System management Dynamic host configuration protocol Provides information to dynamically assign IP addresses and other configuration parameters to network hosts based on policies (see DHCP commands). Network time protocol Provides information about how to synchronize timekeeping between time - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 361
The table shows common options using DHCP packet formats. Subnet mask 1 - Client's subnet mask Router 3 - Router IP addresses that serve as the client's default gateway Domain name server 6 - Domain name servers (DNS) that are available to the client Domain name 15 - Domain name that clients - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 362
it easier to add new devices to the network. The DHCP access service minimizes the overhead required to add clients to the network by providing a centralized, server-based setup. This setup means you do not have to manually create and maintain IP address assignments for clients. When you use DHCP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 363
(conf-dhcp)# no disable Hostname resolution You have two choices for hostname resolution - domain name server (DNS) or NetBIOS Windows internet naming service (WINS). Both DHCP and WINS clients query IP servers to compare host names to IP addresses. 1 Enable DHCP server-assigned dynamic addresses - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 364
dhcp server OS10(conf-dhcp)# pool Dell OS10(conf-dhcp-Dell)# netbios-name-server 192.168.10.5 OS10(conf-dhcp-Dell)# netbios-node-type Hybrid Manual binding entries Address binding is mapping between the IP address and the media access control (MAC) address of a client. The DHCP server assigns the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 365
ip name-server 1.1.1.1 2::2 ip host dell-f10.com 10.10.10.10 snmp-server community public read-only snmp-server contact http://www.dell.com/support/ snmp-server location United States debug radius false System management 365 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 366
this command enables the DHCP server. OS10(conf-dhcp)# no disable Supported Releases 10.2.0E or later dns-server address Assigns a DNS server ...address8] Parameters • address - Enter the DNS server IP address that services clients on the subnet in A.B.C.D or A::B format. • address2...address8 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 367
command removes the configuration. Example OS10(conf-dhcp-Dell)# domain-name dell.com Supported Releases 10.2.0E or later hardware-address Configures the client hardware address for manual configurations. Syntax Parameters Default Command Mode Usage Information Example hardware-address nn:nn - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 368
conf-if-eth1/1/22)# ip helper-address 20.1.1.1 Example (IPv6) OS10(conf-if-eth1/1/22)# ip helper-address 00:01:e8:8c:4d:0a Supported Releases 10.2.0E or later lease Configures a lease time for the IP addresses in a pool. Syntax lease {infinite | days [hours] [minutes]} Parameters • infinite - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 369
order of preference. The no version of this command returns the value to the default. OS10(conf-dhcp-Dell)# netbios-name-server 192.168.10.5 Supported Releases 10.2.0E or later netbios-node-type Configures the NetBIOS node type for the DHCP client. Syntax Parameters netbios-node-type type type - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 370
CONFIGURATION Usage Information Use this command to create an IP address pool name. Example OS10(conf-dhcp)# pool Dell OS10(conf-dhcp-Dell)# Supported Releases 10.2.0E or later show ip dhcp binding Displays the DHCP binding table with IPv4 addresses. Syntax show ip dhcp binding Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 371
to incomplete DNS requests. The no version of this command returns the value to the default. Example OS10(config)# ip domain-name jay dell.com Supported Releases 10.2.0E or later ip host Configures mapping between the host name server and the IP address. Syntax Parameters ip host [host-name - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 372
table uses this mapping information to resolve host names. The no version of this command disables the mapping. OS10(config)# ip host dell 1.1.1.1 Supported Releases 10.2.0E or later ip name-server Configures up to a three IPv4 or IPv6 addresses used for network name servers. Syntax ip name - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 373
clocks. Using this information, each peer selects the best time from several other clocks, updates the local clock, and estimates its accuracy. NOTE: OS10 supports both NTP server and client roles. Enable NTP NTP is disabled by default. To enable NTP, configure an NTP server to which the system - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 374
View system clock state OS10(config)# do show ntp status system peer: 0.0.0.0 system peer mode: unspec leap indicator: 11 stratum: 16 precision: -22 root distance: 0.00000 s root dispersion: 1.28647 s reference ID: [73.78.73.84] reference time: 00000000.00000000 Mon, Jan system - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 375
an IPv4 address in A.B.C.D format. • ipv6-address - Enter an IPv6 address in nnnn:nnnn:nnnn:nnnn:nnnn:nnnn:nnnn:nnnn format (elision of zeros is supported). • key keyid - Enter a text string as the key exchanged between the NTP server and the client. • prefer - Enter the keyword to set this NTP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 376
the ntp trusted-key command. Use the ntp authenticate command to enable NTP authentication. OS10(config)# ntp authentication-key 1200 md5 0 dell Supported Releases 10.2.0E or later ntp broadcast client Configures the interface to receive NTP broadcasts from an NTP server. Syntax Parameters ntp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 377
the NTP server hierarchy (2 to 10). 8 CONFIGURATION The no version of this command resets the value to the default. OS10(config)# ntp master 6 Supported Releases 10.2.0E or later ntp server Configures an NTP time-serving host. Syntax Parameters ntp server {hostname | ipv4-address | ipv6-address - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 378
the number of hosts you configure, as many polls to the NTP hosts can impact network performance. OS10(config)# ntp server eureka.com Supported Releases 10.2.0E or later ntp source Configures an interface IP address to include in NTP packets. Syntax Parameters ntp source interface interface - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 379
.1.33 0.0.0.0 16 - 256 0 0.00 0.000 16000.0 192.200.0.2 0.0.0.0 16 - 256 0 0.00 0.000 16000.0 OS10# show ntp associations vrf management Supported Releases 10.2.0E or later show ntp status Displays NTP configuration information. Syntax Parameters Default show ntp status status - (Optional - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 380
flags: monitor ntp kernel stats jitter: 0.000000 s stability: 0.000 ppm broadcastdelay: 0.000000 s authdelay: 0.000000 s OS10# show ntp status vrf management Supported Releases 10.2.0E or later System clock OS10 uses NTP to synchronize the system clock with a time-serving host. If you do - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 381
your time zone is later than or earlier than UTC/Greenwich mean time. Example OS10# show clock 2017-01-25T11:00:31.68-08:00 Supported Releases 10.2.1E or later User session management You can manage the active user sessions using the following commands: • Configure the timeout for all the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 382
Mode CONFIGURATION Usage Information The no version of this command disables the timeout. Example OS10(config)# exec-timeout 300 OS10(config)# Supported Releases 10.3.1E or later kill-session Terminate a user session. Syntax kill-session session-ID Parameters session-ID - Enter the user - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 383
58:39Z 4 snmp_user 57 0 0 0 2017-07-10T23:58:40Z 6 admin 17 0 0 4 2017-07-12T03:55:18Z *7 admin 10 0 0 0 2017-07-12T04:42:55Z OS10# Supported Releases 10.3.1E or later Telnet server To allow Telnet TCP/IP connections to an OS10 switch, enable the Telnet server. The OS10 Telnet - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 384
A switch in a Layer 2 network may require a larger MAC address table size, while a switch in a Layer 3 network may require a larger routing table size. OS10 supports several UFT modes for the forwarding tables. By default, OS10 selects a UFT mode which provides a reasonable size for all tables. The - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 385
Configure UFT modes Available UFT modes include L2 MAC table, L3 host table, or L3 route table sizes. • Select a mode to initialize the maximum table size in CONFIGURATION mode. hardware forwarding-table mode [scaled-l2 | scaled-l3-routes | scaled-l3-hosts] • Disable UFT mode in CONFIGURATION mode - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 386
Releases 10.3.0E or later Security To help secure networks against unauthorized access, OS10 supports remote authentication dial-in service (RADIUS) client/server authentication mechanism. The system acts as a RADIUS client and sends authentication requests to a RADIUS server that contains - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 387
role, you are authenticated and authorized. You do not need to enter an enable password because you are automatically placed in EXEC mode. OS10 supports the constrained RBAC model. With this model, you can inherit permissions when you create a new user role, restrict or add commands a user can enter - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 388
View RADIUS server host configuration OS10# show running-configuration ... radius-server host 1.2.4.5 key mysecret ... Delete RADIUS server host OS10# no radius server host 1.2.4.5 Server host settings Configure global communication parameters and specific host parameters for the RADIUS server. If - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 389
• name - Text string for the user name (up to 63 characters). • encryption-type - Type of encryption to use. SHA512 (default), SHA256, or MD5. • password - Clear-text or hashed password string (up to 32 characters). • role - Use netoperator (default) or sysadmin for the role type. Create user OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 390
ssh server cipher cipher-list cipher-list - Enter the list of cipher algorithms separated by space. The following is the list of cipher algorithms supported by the SSH server: • 3des-cbc • aes128-cbc • aes192-cbc • aes256-cbc • aes128-ctr • aes192-ctr • aes256-ctr • [email protected] • aes256 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 391
ip ssh server enable None Enabled CONFIGURATION The no version of this command disables the SSH server. OS10(config)# ip ssh server enable Supported Releases 10.3.0E or later ip ssh server hostbased-authentication Enable host-based authentication in an SSH server. Syntax ip ssh server hostbased - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 392
ip ssh server mac hmac-algorithm hmac-algorithm - Enter the list of HMAC algorithms separated by space. The following is the list of HMAC algorithms supported by the SSH server: • hmac-md5 • hmac-md5-96 • hmac-ripemd160 • hmac-sha1 • hmac-sha1-96 • hmac-sha2-256 • hmac-sha2-512 • umac-64@openssh - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 393
The no version of this command removes the configuration. OS10(config)# ip ssh server mac hmac-md5 hmac-md5-96 hmac-ripemd160 Supported Releases 10.3.0E or later ip ssh server password-authentication Enable password authentication in an SSH server. Syntax ip ssh server password-authentication - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 394
RADIUS server. The no version of this command resets the value to the default. OS10(config)# radius-server host 1.5.6.4 key secret1 retransmit 2 Supported Releases 10.2.0E or later radius-server key Configures the authentication key the RADIUS server uses. Syntax radius-server key value 394 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 395
(0 to 1000). Not configured CONFIGURATION The no version of this command resets the value to the default. OS10(config)# radius-server timeout 360 Supported Releases 10.2.0E or later show ip ssh Displays the SSH server information. Syntax Parameters Default Command Mode show ip ssh None Not - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 396
Index Line User Role Application Idle Location Login-Time Lock 1 ttyS0 admin sysadmin login/clish . - 2016-04-29 01:02:00 Supported Releases 10.2.0E or later username Creates an authentication system based on user names. Syntax username username password [encryption-type password] [role - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 397
of this command removes access to a community. OS10(config)# snmp-server community public ro Supported Releases 10.2.0E or later snmp-server contact Configures contact information for troubleshooting this SNMP node. Syntax Parameters snmp-server contact text text - Enter an alphanumeric text - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 398
2 Backup the startup configuration in EXEC mode. copy config://startup.xml config:// 3 Download the new software image from dell.com/support and save the file in EXEC mode. image download file-url 4 (Optional) View the current software download status in EXEC mode. show image - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 399
Image download OS10# image download ftp://userid:passwd@hostip/filepath Image install OS10# image install image://filename.bin Image upgrade OS10# image upgrade ftp://userid:passwd@hostip/filepath Show version OS10# show version Dell EMC Networking OS10 Enterprise Copyright (c) 1999-2017 by Dell Inc - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 400
Usage Information Example image cancel None Not configured EXEC This command attempts to cancel an active file download in progress. OS10# image cancel Supported Releases 10.2.0E or later image copy Copies the entire image in the active partition to the standby partition (mirror image). Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 401
command to view the progress. OS10# image download ftp://[email protected]/PKGS_OS10-Enterprise-10.2.0E. 190-installer-x86_64.bin Supported Releases 10.2.0E or later image install Installs a new image, either from a previously downloaded file or from a remote location. Syntax Parameters image - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 402
status command to view the installation progress. OS10# image install ftp://10.206.28.174/PKGS_OS10-Enterprise-10.2.0E.190installer-x86_64.bin Supported Releases 10.2.0E or later image upgrade Upgrades to software image. Syntax Parameters image upgrade file-url • file-url - Location of the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 403
:11:14Z Standby Partition: A Standby SW Version: 10.2.0E Standby Build Date/Time: 2016-10-03T23:11:14Z Next-Boot: active[B] Supported Releases 10.2.0E or later show image status Displays image transfer and installation information. Syntax Parameters Default Command Mode Usage Information - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 404
.2.9999E(4265) Build Time: 2017-04-13T06:00:50.738-07:00 System Type: S6000-ON Architecture: x86_64 Up Time: 2 weeks 1 day 10:27:15 Supported Releases 10.2.0E or later 404 System management - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 405
7 Access Control Lists OS10 uses two types of access policies - hardware-based ACLs and software-based route-maps. Use an ACL to filter traffic and drop or forward matching packets. To redistribute routes that match configured criteria, use a route-map. ACLs ACLs are a filter containing criterion to - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 406
ACLs are enabled by default and support ACLs on all platforms. NOTE: Hot-lock ACLs support ingress ACLs only. MAC ACLs MAC ID Set in the packet header Class of service Present in the packet header IPv4/IPv6 and size limit. This provides a particular problem for ACL processing. If the ACL filters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 407
Permit all packets on interface OS10(config)# ip access-list ABC OS10(conf-ipv4-acl)# permit ip any 10.1.1.1/32 OS10(conf-ipv4-acl)# deny ip any 10.1.1.1/32 fragments L3 ACL rules Use ACL commands for L3 packet filtering. TCP packets from host 10.1.1.1 with the TCP destination port equal to 24 are - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 408
Assign sequence number to filter IP ACLs filter on source and destination IP addresses, IP host addresses, TCP addresses, TCP host addresses, UDP addresses, and UDP host addresses. Traffic passes through the filter by filter sequence. Configure the IP ACL by first entering IP ACCESS-LIST mode and - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 409
• Egress L2 ACL Table 5. L2 and L3 targeted traffic L2 ACL / L3 ACL Deny / Deny Deny / Permit Permit / Deny Permit / Permit Targeted traffic L3 ACL denies L3 ACL permits L3 ACL denies L3 ACL permits Assign and apply ACL filters To filter an Ethernet interface, a port-channel interface, or a VLAN - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 410
onto each interface and achieves the same results. You can use an egress ACL filter to restrict egress traffic. For example, when a denial of service (DOS) attack traffic is isolated to a specific interface, apply an egress ACL filter to block the flow from exiting the network and thus protect - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 411
ethernet1/1/29 seq 10 deny ip any any fragment count (100 packets) Clear access-list counters Clear IPv4, IPv6, or MAC access-list counters for a specific access-list or all lists. The counter counts the number of packets that match each permit or deny statement in an access-list. To get a more - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 412
Route-maps Route-maps a series of commands that contain a matching criterion and action. They change the packets meeting the matching criterion. ACLs and prefix-lists can only drop or forward the packet or traffic while route-maps process routes for route redistribution. For example, use a route-map - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 413
View route-map configuration OS10(conf-router-bgp-neighbor-af)# do show route-map route-map test1, deny, sequence 10 Match clauses: ip address prefix-list p1 Set clauses: route-map test2, permit, sequence 10 Match clauses: ip address prefix-list p1 Set clauses: route-map test3, deny, sequence 10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 414
set weight value Check set conditions OS10(config)# route-map ip permit 1 OS10(conf-route-map)# match metric 2567 continue Clause Only BGP route-maps support the continue clause. When a match is found, set clauses run and the packet is forwarded - no routemap processing occurs. If you configure the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 415
ACL on the source port or the monitored port, both flow-based monitoring and port mirroring do not function. Flow-based monitoring is supported only for ingress traffic. The show monitor session session-id command displays output which indicates if a particular session is enabled for flowmonitoring - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 416
the counters to start at zero. To view access-list information, use the show access-lists command. OS10# clear ip access-list counters Supported Releases 10.2.0E or later clear ipv6 access-list counters Clears IPv6 access-list counters for a specific access-list. Syntax clear ipv6 access-list - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 417
counters to start at zero. To view access-list information, use the show access-lists command. Example OS10# clear mac access-list counters Supported Releases 10.2.0E or later deny Configures a filter to drop packets with a specific IP address. Syntax deny [protocol-number | icmp | ip | tcp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 418
no version of this command removes the filter. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# deny ipv6 any any capture session 1 count Supported Releases 10.2.0E or later deny (MAC) Configures a filter to drop packets with a specific MAC address. Syntax deny {nn:nn:nn:nn:nn:nn - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 419
removes the filter. OS10(config)# mac access-list macacl OS10(conf-mac-acl)# deny any any cos 7 OS10(conf-mac-acl)# deny any any vlan 2 Supported Releases 10.2.0E or later deny icmp Configures a filter to drop all or specific internet control message protocol (ICMP) messages. Syntax deny icmp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 420
no version of this command removes the filter. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# deny icmp any any capture session 1 count Supported Releases 10.2.0E or later deny ip Configures a filter to drop all or specific packets from an IPv4 address. Syntax Parameters deny ip - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 421
of this command removes the filter. OS10(config)# ip access-list testflow OS10(conf-ipv4-acl)# deny ip any any capture session 1 count Supported Releases 10.2.0E or later deny ipv6 Configures a filter to drop all or specific packets from an IPv6 address. Syntax deny ipv6 [A::B | A::B/x | any - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 422
no version of this command removes the filter. OS10(config)# ip access-list testflow OS10(conf-ipv4-acl)# deny tcp any any capture session 1 count Supported Releases 10.2.0E or later deny tcp (IPv6) Configures a filter that drops TCP IPv6 packets meeting the filter criteria. Syntax deny tcp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 423
no version of this command removes the filter. OS10(config)# ip access-list testflow OS10(conf-ipv4-acl)# deny udp any any capture session 1 count Supported Releases 10.2.0E or later deny udp (IPv6) Configures a filter to drop UDP IPv6 packets that match filter criteria. Syntax deny udp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 424
. Disabled IPV4-ACL, IPV6-ACL, MAC-ACL The no version of this command deletes the ACL description. OS10(conf-ipv4-acl)# description ipacltest Supported Releases 10.2.0E or later ip access-group Assigns an IP access group to an interface. Syntax Parameters ip access-group access-list-name {in - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 425
Example Not configured INTERFACE The no version of this command deletes an IP ACL configuration. OS10(conf-if-eth1/1/8)# ip access-group testgroup in Supported Releases 10.2.0E or later ip access-list Creates an IP access list to filter based on an IP address. Syntax Parameters Default Command - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 426
configured CONFIGURATION The no version of this command removes the access-list. Example OS10(config)# ip as-path access-list abc permit 200 Supported Release 10.3.0E or later ip community-list standard deny Creates a standard community list for BGP to deny access. Syntax ip community-list - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 427
Not configured CONFIGURATION The no version of this command removes the community list. OS10(config)# ip community-list standard STD_LIST permit local-AS Supported Release 10.3.0E or later ip extcommunity-list standard deny Creates an extended community list for BGP to deny access. Syntax ip - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 428
version of this command removes the extended community list. OS10(config)# ip extcommunity-list standard STD_LIST permit 4byteas-generic transitive 1.65412:60 Supported Release 10.3.0E or later ip prefix-list description Configures a description of an IP prefix list. Syntax ip prefix-list name - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 429
The no version of this command removes the specified prefix-list. OS10(config)# ip prefix-list allowprefix permit 10.10.10.1/16 ge 10 Supported Release 10.3.0E or later ip prefix-list seq deny Configures a filter to deny route filtering from a specified prefix list. Syntax ip prefix-list - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 430
no version of this command removes the specified prefix list. OS10(config)# ip prefix-list seqprefix seq 65535 permit 10.10.10.1/16 le 30 Supported Release 10.3.0E or later ipv6 access-group Assigns an IPv6 access list to an interface. Syntax ipv6 access-group access-list-name {in | out - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 431
The no version of this command removes the specified prefix list. OS10(config)# ipv6 prefix-list TEST deny AB10::1/128 ge 10 le 30 Supported Release 10.3.0E or later ipv6 prefix-list description Configures a description of an IPv6 prefix-list. Syntax Parameters ipv6 prefix-list name description - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 432
The no version of this command removes the specified prefix-list. OS10(config)# ipv6 prefix-list TEST permit AB20::1/128 ge 10 le 30 Supported Release 10.3.0E or later ipv6 prefix-list seq deny Configures a filter to deny route filtering from a specified prefix-list. Syntax Parameters ipv6 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 433
configured CONFIGURATION The no version of this command resets the value to the default. OS10(config)# mac access-group maclist in OS10(conf-mac-acl)# Supported Releases 10.2.0E or later mac access-list Creates a MAC access list to filter based on an MAC address. Syntax mac access-list access - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 434
Default Command Mode Usage Information Example Not configured CONFIGURATION None OS10(config)# mac access-list maclist Supported Releases 10.2.0E or later permit Configures a filter to allow packets with a specific IP address. Syntax Parameters permit [protocol-number | icmp | ip | tcp | udp] - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 435
of this command removes the filter. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# permit udp any any capture session 1 count Supported Releases 10.2.0E or later permit (MAC) Configures a filter to allow packets with a specific MAC address. Syntax Parameters permit {nn:nn:nn:nn - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 436
:11:11:11:11 any cos 7 OS10(conf-mac-acl)# permit 00:00:00:00:11:11 00:00:11:11:11:11 any vlan 2 Supported Releases 10.2.0E or later permit icmp Configures a filter to permit all or specific internet control message protocol (ICMP) messages. Syntax permit icmp [A.B.C.D | A.B.C.D/x | any | host - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 437
of this command removes the filter. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# permit icmp any any capture session 1 count Supported Releases 10.2.0E or later permit ip Configures a filter to permit all or specific packets from an IP address. Syntax Parameters permit ip - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 438
bytes increment. The no version of this command removes the filter. OS10(conf-ipv4-acl)# permit ip any any capture session 1 count Supported Releases 10.2.0E or later permit ipv6 Configures a filter to permit all or specific packets from an IPv6 address. Syntax permit ipv6 [A::B | A::B/x | any - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 439
bytes increment. The no version of this command removes the filter. OS10(conf-ipv4-acl)# permit tcp any any capture session 1 count Supported Releases 10.2.0E or later permit tcp (IPv6) Configures a filter to permit TCP packets meeting the filter criteria. Syntax permit tcp [A::B | A::B/x | any - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 440
no version of this command removes the filter. OS10(config)# ip access-list testflow OS10(conf-ipv4-acl)# permit udp any any capture session 1 count Supported Releases 10.2.0E or later 440 Access Control Lists - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 441
bytes increment. The no version of this command removes the filter. OS10(conf-ipv6-acl)# permit udp any any capture session 1 count Supported Releases 10.2.0E or later remark Specifies an ACL entry description. Syntax remark [remark-number] [description] Parameters • remark-number - (Optional - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 442
IPv4, IPv6, or MAC. OS10(conf-ipv4-acl)# remark 10 Deny rest of the traffic OS10(conf-ipv4-acl)# remark 5 Permit traffic from XYZ Inc. Supported Releases 10.2.0E or later seq deny Assigns a sequence number to deny IP addresses while creating the filter. Syntax seq sequence-number deny [protocol - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 443
you know the filter's sequence number. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# seq 5 deny ipv6 any any capture session 1 count Supported Releases 10.2.0E or later seq deny (MAC) Assigns a sequence number to a deny filter in a MAC access list while creating the filter. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 444
:11:11 any cos 7 OS10(conf-mac-acl)# seq 20 deny 00:00:00:00:11:11 00:00:11:11:11:11 any vlan 2 Supported Releases 10.2.0E or later seq deny icmp Assigns a filter to deny internet control message protocol (ICMP) messages while creating the filter. Syntax seq sequence - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 445
the filter's sequence number. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# seq 10 deny icmp any any capture session 1 count Supported Releases 10.2.0E or later seq deny ip Assigns a sequence number to deny IP addresses while creating the filter. Syntax seq sequence-number deny - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 446
know the filter's sequence number. OS10(config)# ip access-list egress OS10(config-ipv4-acl)# seq 10 deny ip any any capture session 1 count Supported Releases 10.2.0E or later seq deny ipv6 Assigns a filter to deny IPv6 addresses while creating the filter. Syntax seq sequence-number deny ip - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 447
you know the filter's sequence number. OS10(config)# ip access-list egress OS10(conf-ipv4-acl)# seq 10 deny tcp any any capture session 1 count Supported Releases 10.2.0E or later seq deny tcp (IPv6) Assigns a filter to deny TCP packets while creating the filter. Syntax seq sequence-number deny - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 448
the filter's sequence number. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# seq 10 deny tcp any any capture session 1 count Supported Releases 10.2.0E or later seq deny udp Assigns a filter to deny UDP packets while creating the filter. Syntax Parameters seq sequence-number deny - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 449
the filter's sequence number. OS10(config)# ip access-list egress OS10(conf-ipv4-acl)# seq 10 deny udp any any capture session 1 count Supported Releases 10.2.0E or later seq deny udp (IPv6) Assigns a filter to deny UDP packets while creating the filter. Syntax Parameters seq sequence-number - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 450
the filter's sequence number. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# seq 10 deny udp any any capture session 1 count Supported Releases 10.2.0E or later seq permit Assigns a sequence number to permit packets while creating the filter. Syntax Parameters seq sequence-number - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 451
the filter's sequence number. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# seq 10 permit ipv6 any any capture session 1 count Supported Releases 10.2.0E or later seq permit (MAC) Assigns a sequence number to permit MAC addresses while creating a filter. Syntax Parameters seq - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 452
:11:11 any cos 7 OS10(conf-mac-acl)# seq 20 permit 00:00:00:00:11:11 00:00:11:11:11:11 any vlan 2 Supported Releases 10.2.0E or later seq permit icmp Assigns a sequence number to allow ICMP messages while creating the filter Syntax seq sequence-number permit icmp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 453
the filter's sequence number. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# seq 5 permit icmp any any capture session 1 count Supported Releases 10.2.0E or later seq permit ip Assigns a sequence number to allow packets while creating the filter. Syntax Parameters seq sequence - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 454
know the filter's sequence number. OS10(config)# ip access-list egress OS10(conf-ipv4-acl)# seq 5 permit ip any any capture session 1 count Supported Releases 10.2.0E or later seq permit ipv6 Assigns a sequence number to allow packets while creating the filter. Syntax seq sequence-number permit - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 455
if you know the filter's sequence number. OS10(config)# ip access-list egress OS10(conf-ipv4-acl)# seq 5 permit tcp any any capture session 1 count Supported Releases 10.2.0E or later seq permit tcp (IPv6) Assigns a sequence number to allow TCP IPv6 packets while creating the filter. Syntax seq - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 456
you know the filter's sequence number. OS10(config)# ipv6 access-list egress OS10(conf-ipv6-acl)# seq 5 permit tcp any any capture session 1 count Supported Releases 10.2.0E or later seq permit udp Assigns a sequence number to allow UDP packets while creating the filter. Syntax Parameters seq - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 457
the filter's sequence number. OS10(config)# ip access-list egress OS10(conf-ipv4-acl)# seq 5 permit udp any any capture session 1 count Supported Releases 10.2.0E or later seq permit udp (IPv6) Assigns a sequence number to allow UDP IPv6 packets while creating a filter. Syntax Parameters seq - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 458
access-group ccc Ingress IPV6 access list aaa on ethernet 3/0 Ingress IPV6 access list aaa on ethernet 4/0 Egress IPV6 access list aaa on ethernet 4/0 Supported Releases 10.2.0E or later show access-lists Displays IP, MAC, or IPv6 access-list information. Syntax Parameters show {ip | mac | ipv6 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 459
• access-lists in | out - Enter either access lists in or access lists out. • access-list-name - Enter the name of the access-list. Default Command Mode Usage Information Example (MAC In) Not configured EXEC None OS10# show mac access-lists in Ingress MAC access list aaa Active on interfaces : - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 460
Command Mode EXEC Usage Information None Example OS10# show ip as-path-access-list ip as-path access-list hello permit 123 deny 35 Supported Releases 10.3.0E or later show ip community-list Displays the configured IP community lists in alphabetic order. Syntax Parameters Defaults Command Mode - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 461
24 seq 20 permit 3.4.4.5/32 Example (IPv6) OS10# show ipv6 prefix-list ipv6 prefix-list hello: seq 10 permit 1::1/64 seq 20 deny 2::2/64 Supported Releases 10.3.0E or later Route-map commands continue Configures the next sequence of the route map. Syntax continue seq-number Parameters seq - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 462
no version of this command deletes a match AS path filter. OS10(config)# route-map bgp OS10(conf-route-map)# match as-path pathtest1 Supported Releases 10.3.0E or later match community Configures a filter to match routes that have a certain COMMUNITY attribute in their BGP path. Syntax match - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 463
configured ROUTE-MAP The no version of this command deletes the match. OS10(conf-route-map)# match interface ethernet 1/1/1 OS10(conf-if-eth1/1/1)# Supported Releases 10.2.0E or later match ip address Configures a filter to match routes based on IP addresses specified in IP prefix lists. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 464
bgp OS10(conf-route-map)# match ip next-hop prefix-list test100 Supported Releases 10.3.0E or later match ipv6 address Configures a filter to (config)# route-map bgp OS10(conf-route-map)# match ipv6 address test100 Supported Releases 10.3.0E or later match ipv6 next-hop Configures a filter to - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 465
Not configured ROUTE-MAP The no version of this command deletes the match. OS10(config)# route-map bgp OS10(conf-route-map)# match origin egp Supported Releases 10.3.0E or later match route-type Configures a filter to match routes based on how the route is defined. Syntax match route-type - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 466
Command Mode ROUTE-MAP Usage Information The no version of this command deletes the match. Example OS10(conf-route-map)# match tag 656442 Supported Releases 10.2.0E or later route-map Enables a route-map statement and configures its action and sequence number. Syntax Parameters route-map map - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 467
no version of this command deletes a BGP COMMUNITY attribute assignment. OS10(config)# route-map bgp OS10(conf-route-map)# set community none Supported Releases 10.3.0E or later set extcomm-list delete Remove communities in the specified list from the EXT COMMUNITY attribute in a matching inbound - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 468
command deletes the set clause from a route map. OS10(config)# route-map bgp OS10(conf-route-map)# set extcommunity rt 10.10.10.2:325 Supported Releases 10.3.0E or later set local-preference Sets the preference value for the AS path. Syntax set local-preference value Parameters value - Enter - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 469
no version of this command removes the filter. OS10(conf-route-map)# set metric 10 Example (Relative) OS10(conf-route-map)# set metric -25 Supported Releases 10.2.0E or later set metric-type Set the metric type for the a redistributed routel. Syntax set metric-type {type-1 | type-2 | external - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 470
the setting. OS10(conf-route-map)# set ip next-hop 10.10.10.2 Example (IPv6) OS10(conf-route-map)# set ipv6 next-hop 11AA:22CC::9 Supported Releases 10.2.0E or later set origin Set the origin of the advertised route. Syntax set origin {egp | igp | incomplete} Parameters • egp - Enter to add - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 471
clause from a route map. Example OS10(conf-route-map)# set tag 23 Supported Releases 10.2.0E or later set weight Set the BGP weight for the routing the route map. Example OS10(conf-route-map)# set weight 200 Supported Releases 10.2.0E or later show route-map Displays the current route - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 472
route-type external type-1 tag 10 Set clauses: metric-type type-1 origin igp tag 100 Supported Releases 10.3.0E or later 472 Access Control Lists - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 473
jitter, bandwidth, and packet loss parameters on a network. OS10 devices examine each received packet and place the packet into different classes of service (CoS) by assigning a traffic class ID depending on the packet QoS parameters. QoS allows you to assign different behaviors to different traffic - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 474
in SYSTEM-QOS mode, or apply egress policy actions (queuing-type policy) to egress interfaces in SYSTEM-QOS mode. Configure quality of service Network traffic is processed based on classification and policies that are created and applied to the traffic. Configuring QoS is a three-step process - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 475
-qos)# match cos 1 Show class-map OS10(conf-cmap-qos)# do show class-map type qos c1 Class-map (qos): c1 (match-cos) Quality of service 475 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 476
p1 OS10(conf-pmap-qos)# class c1 OS10(conf-pmap-c-qos)# set qos-group 1 Show policy-map OS10(conf-pmap-c-qos)# do show policy-map Service-policy(qos) input: p1 Class-map (qos): c1 set qos-group 1 Interface policy-map You can apply policy-maps directly to interfaces. 1 To attach a policy - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 477
to the control-plane. 1 Enter CONTROL-PLANE configuration mode from CONFIGURATION mode. control-plane 2 Apply the service policy, and create a name for the policy-map in CONTROL-PLANE mode. service-policy input policy-map-name Attach policy-map to control-plane OS10(config)# control-plane OS10(conf - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 478
-trust OS10(conf-pmap-qos)# class class-trust OS10(conf-pmap-c-qos)# trust dot1p View policy-map OS10(conf-pmap-c-qos)# do show policy-map Service-policy(qos) input: policy-trust Class-map (qos): class-trust trust dot1p Queue selection OS10 does not honor DSCP values on ingress traffic by default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 479
priority queuing OS10 uses queues for egress QoS policy-types. You can enable priorities to dequeue all packets from the assigned queue before servicing any other queues. When more than one queue is assigned strict priority, the highest number queue receives the highest priority. You can configure - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 480
red OS10(conf-pmap-qos)# class bluedot1p OS10(conf-pmap-c-qos)# set qos-group 5 View policy-map OS10(conf-pmap-c-qos)# do show policy-map Service-policy(qos) input: red Class-map (qos): bluedot1p set qos-group 5 DSCP classification Classify traffic based on the DSCP value. The value of the QoS - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 481
reddscp OS10(conf-pmap-qos)# class bluedscp OS10(conf-pmap-c-qos)# set qos-group 7 View policy-map OS10(conf-pmap-c-qos)# do show policy-map Service-policy(qos) input: reddscp Class-map (qos): bluedscp set qos-group 7 MAC address classification Classify the QoS traffic based on the MAC access-list - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 482
OS10(conf-pmap-qos)# class bluevlan OS10(conf-pmap-c-qos)# set qos-group 6 View policy-map OS10(conf-pmap-c-qos)# do show policy-map Service-policy(qos) input: redvlan Class-map (qos): bluevlan set qos-group 6 IP access-group classification With this classification, traffic that accesses the IP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 483
-policy(qos) input: redscp Class-map (qos): bluedscp set qos-group 7 Service-policy(qos) input: redvlan Class-map (qos): bluevlan set qos-group 6 Service-policy(qos) input: redacl Class-map (qos): blueacl set cos 6 set qos-group 6 Service-policy(qos) input: ag2 Class-map (qos): accgrp set qos-group - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 484
marking To tag an incoming packet with 802.1p priorities, or modify incoming packets you can mark class of service (CoS). The set cos command is only supported under the ingress QoS policy type qos. 1 Create a policy-map of type qos and configure a name for the policy-map in CONFIGURATION mode - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 485
group 7 View policy-map OS10(conf-pmap-c-qos)# do show policy-map Service-policy(qos) input: platinum Class-map (qos): diamond set dscp 50 qos-group corresponds to data queues 0 to 7. The maximum number of data queues supported in OS10 are 8, and the maximum number of control traffic queues are 12. - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 486
(conf-pmap-c)# set qos-group 2 OS10(conf-pmap-c)# police cir 100 pir 100 View control-plane policy-map OS10(conf-pmap-c)# do show policy-map Service-policy(control-plane) input: copp1 Class-map (control-plane): copp set qos-group 2 police cir 100 bc 100 pir 100 be 100 Traffic metering Metering - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 487
(match-any) Match: qos-group 5 View policy-map OS10(conf-pmap-c-que)# do show policy-map Service-policy (queuing) output: solar Class-map (queuing): lunar bandwidth percent 80 Service-policy rate-shaping Rate-shaping buffers traffic exceeding the specified rate until the buffer is exhausted. Traffic - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 488
-pmap-c-qos)# police cir 5 pir 30 View policy-map OS10(conf-pmap-c-qos)# do show policy-map Service-policy (qos) input: galaxy Class-map (qos): bigbang police cir 5 bc 30 pir 20 be 40 Service-policy (qos) input: bronze Class-map (qos): silver police cir 5 bc 100 pir 30 be 100 488 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 489
Create QoS policies (class maps and policy maps) for the desired CPU-bound queue. • Associate the QoS policy with a particular rate-limit. • Assign the QoS service policy to control plane queues. By default, the pir and cir values are in pps for control plane. CoPP for CPU queues converts the input - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 490
each queue. You can also use the show command output to verify the CoPP configuration. View CoPP configuration OS10# show qos control-plane Service-policy (input): pmap1 View CMAP1 configuration OS10# show class-map type control-plane cmap1 Class-map (control-plane): cmap1 (match-any) View CoPP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 491
IPV6_ICMP_REQ ARP_RESP IPV6_ICMP IPV6_ICMP_RESP IPV4_ICMP SSH TELNET TACACS NTP FTP RSTP PVST MSTP LACP DOT1X LLDP IPV6_OSPF IPV4_BGP IPV4_OSPF IPV6_DHCP IPV4_DHCP SERVICEABILITY OPEN_FLOW View CoPP statistics OS10# show control-plane statistics Queue Packets Bytes Dropped Packets Dropped Bytes - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 492
-queuing)# class silver OS10(conf-pmap-c-que)# random-detect minimum-threshold 10 maximum-threshold 100 dropprobability 50 color yellow ecn weight 10 492 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 493
View configured WRED profile OS10# show policy-map interface Service-policy (qos) input: p1 Class (qos): c1 set qos-group 1 Class (qos): c2 set qos-group 4 Class (qos): c3 -plane | qos | queuing}class-map-name • type-Enter the policy-map type (qos, queuing or control-plane). Quality of service 493 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 494
-map type qos c1 Class-map (qos): c1 (match-all) Match(not): ip-any dscp 10 View QoS policy-map OS10# show policy-map interface Service-policy (qos) input: p1 Class (qos): c1 set qos-group 1 Class (qos): c2 set qos-group 4 Class (qos): c3 set qos-group 7 Egress queue statistics - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 495
cannot use the priority command for the class. Example OS10(conf-pmap-que)# bandwidth percent 70 Supported Releases 10.2.0E or later class Creates a QoS class for a type of policy-map. be qos. Example OS10(conf-pmap-qos)# class c1 Supported Releases 10.2.0E or later Quality of service 495 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 496
/slot/port[:subport] - (Optional) Enter the port information. Default Command Mode Usage Information Example Not configured EXEC None OS10# clear interface ethernet 1/1/1 priority-flow-control Supported Releases 10.3.0E or later 496 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 497
Command Mode EXEC Usage Information None Example OS10# clear qos statistics Supported Releases 10.2.0E or later clear qos statistics type Clears all 1/1/7 OS10# clear qos statistics type queuing interface ethernet 1/1/2 Supported Releases 10.2.0E or later control-plane Enters Control-Plane - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 498
command returns the value to the default. OS10(conf-if-eth1/1/2)# flowcontrol transmit on Supported Releases 10.3.0E or later match Configures match criteria for the QoS policy. Syntax Parameters ) Enter a precedence value for Layer 3 precedence match criteria (0 to 7). 498 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 499
, the access-list ignores the permit and deny keywords. OS10(conf-cmap-qos)# match ip access-group name ag1 Supported Releases 10.2.0E or later match cos Matches a cost of service (CoS) value to L2 dot1p packets. Syntax Parameters match [not] cos cos-value • cos-value - Enter a CoS value (0 to - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 500
the second statement overwrites the first statement. The match-all option in a class-map does not support ip-any. Select either ip or IPv6 for the match-all criteria. If you select ip- (0 to 7). OS10(conf-cmap-queuing)# match queue 1 Supported Releases 10.2.0E or later 500 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 501
The no version of this command returns the value to the default. OS10(conf-pmap-nqos-c)# mtu 2500 Supported Releases 10.3.0E or later pause Enables a pause based on buffer limits for the port to start or 9). Default Command Mode See parameter values POLICY-MAP-CLASS-MAP Quality of service 501 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 502
pause-threshold 30 resumethreshold 10 OS10(conf-cmap-nqos-c)# queue-limit thresh-mode static 150 Supported Releases 10.3.0E or later pfc-cos Configures priority flow-control for cost of service (CoS). Syntax Parameters Default Command Mode Usage Information Example pfc-cos cos-value cos-value - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 503
values, the committed-rate cir values are taken as the pir values. Only the ingress QoS policy type supports this command. For control-plane policing, the rate values are in pps. OS10(conf-pmap-c-qos)# police map-name - Enter a class name for the policy-map (up to 32 characters). Quality of service 503 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 504
config)# policy-map p1 Example (Queuing) OS10(config)# policy-map type queuing p1 Supported Releases 10.2.0E or later priority Sets the scheduler as a strict-priority. Syntax OS10(conf-if-eth1/1/2)# priority-flow-control mode on Supported Releases 10.3.0E or later 504 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 505
value to the default. OS10(conf-tmap-dot1p-qos)# qos-group 5 dot1p 5 Supported Releases 10.3.0E or later qos-group dscp Configures a dscp trust map to the default. OS10(conf-tmap-dscp-qos)# qos-group 5 dscp 42 Supported Releases 10.3.0E or later queue-limit Configures static or dynamic shared - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 506
que)# queue-limit queue-len 100 OS10(config-pmap-c-que)# queue-limit thresh-mode static 50 Supported Releases 10.3.0E or later queue qos-group Configures a dot1p traffic class to a queue. either single, comma-delimited, or a hyphenated range of dot1p values (0 to 7). 506 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 507
-threshold 10 maximum-threshold 100 drop-probability 50 color yellow ecn weight 10 Supported Releases 10.2.0E or later service-policy Configures the input and output service policies. Syntax Parameters service-policy {input | output} [type {qos | queuing}] policy-map-name • input - Enter to - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 508
-level, the interface-level policy takes precedence over the system-level policy. OS10(conf-if-eth1/1/7)# service-policy input type qos p1 Supported Releases 10.2.0E or later set cos Sets a cost of service (CoS) value to mark L2 802.1p (dot1p) packets. Syntax set cos cos-value Parameters cos - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 509
Usage Information Example 50 kb or 200 packets POLICY-MAP-CLASS-MAP Only the ingress QoS policy type supports this command. You must enter both the minimum and maximum values. If you enter the rate pmap-c-que)# shape min pps 10 max pps 40 Supported Releases 10.2.0E or later Quality of service 509 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 510
plane info None Not configured EXEC Monitors statistics for the control-plane and to troubleshoot CoPP. OS10# show control-plane info Queue Rate Limit(in pps) Protocols IPV4_OSPF 10 600 IPV6_DHCP IPV4_DHCP SERVICEABILITY 11 300 OPEN_FLOW Supported Releases 10.2.0E or later 510 Quality of - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 511
0 0 0 0 5 2 172 0 0 6 0 0 0 0 7 32048 2180484 0 0 8 14140 2569184 0 0 9 0 0 0 0 10 0 0 0 0 11 0 0 0 0 Supported Releases 10.2.0E or later show interface priority-flow-control Tx 0 0 0 1 0 0 2 0 0 3 300 200 4 0 0 5 0 0 Quality of service 511 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 512
: 100 pps multicast-storm-control : 200 pps broadcast-storm-control : Disabled flow-control-rx: Enabled flow-control-tx: Disabled Service-policy (Input)(qos): p1 Supported Releases 10.2.0E or later show policy-map Displays information on all existing policy-maps. Syntax show policy-map type - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 513
Not configured Command Mode EXEC Usage Information Monitors statistics for the control-plane and troubleshoots CoPP. Example OS10# show qos control-plane Service-policy (Input): p1 Supported Releases 10.2.0E or later show qos egress bufffers interface Displays egress buffer configurations - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 514
3 0 0 0 0 4 0 0 0 0 5 0 0 0 0 6 0 0 0 0 7 0 0 0 0 OS10# Supported Releases 10.3.0E or later show qos ingress buffers interface Displays interface - - - - - 2 - - - - - 3 - - - - - 4 - - - - - 5 - - - - - 6 - - - - 514 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 515
0 0 0 0 1 0 0 0 2 0 0 0 3 0 0 0 4 0 0 0 5 0 0 0 6 0 0 0 7 0 0 0 OS10# Supported Releases 10.3.0E or later show queuing statistics Displays QoS queuing statistics information counters. WRED counters are available only at the port level. Quality of service 515 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 516
Command Mode EXEC Usage Information View and verify system-level service-policy configuration information. Example OS10# show qos system Service-policy (Input) (qos) : policy1 Service-policy (Output)(queuing) : policy2 Supported Releases 10.2.0E or later show qos system buffers Displays - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 517
lossy buffers - 8178 Total shared lossy buffers - 5938 Total used shared lossy buffers - 0 Supported Releases 10.3.0E or later show qos maps Displays the active system trust map. Syntax show qos -Class to Queue Map: queue-map1 Queue Traffic-Class 1 5 2 6 Quality of service 517 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 518
trust-map dscp new-dscp-map new-dscp-map qos-group Dscp Id 0 0-7 1 8-15 2 16-23 3 24-31 4 32-39 5 40-47 518 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 519
qos Enters SYSTEM-QOS mode to configure system-level service policies. Syntax system qos Parameters None Default Not configured Command Mode SYSTEM-QOS Usage Information None Example OS10(config)# system qos OS10(config-sys-qos)# Supported Releases 10.2.0E or later trust Sets the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 520
dot1p-map)# qos-group 4 dot1p 5 Supported Releases 10.3.0E or later trust dscp-map (config)# trust dscp-map dscp-trust1 Supported Releases 10.3.0E or later qos-map -qos-map)# queue 3 qos-group 7 OS10(config-qos-map)# Supported Releases 10.3.0E or later trust-map Applies a dot1p or dscp traffic - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 521
. The no version of this command returns the value to the default. OS10(config)# interface ethernet 1/1/1 OS10(conf-if-eth1/1/1)# trust-map dscp dscp-trustmap1 Supported Releases 10.3.0E or later Quality of service 521 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 522
role of spanning tree protocols (STPs) by allowing link aggregation group (LAG) terminations on two separate distribution or core switches and supporting a loop-free topology. • Allows a single device to use a LAG across two upstream devices • Provides a loop-free topology • Eliminates STP-blocked - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 523
to the attached devices. It is also associated with the configuration mode that you must use to assign VLT global parameters. • A VLT domain supports two node members. These peer devices appear as a single logical device to network access devices that connect to VLT ports through a port-channel - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 524
peers, the VLTi does not activate. • In a VLT domain, VLT peers support connections to network devices that connect to only one peer. VLT interconnect A VLTi roles in the VLT domain are automatically assigned. 4 (Optional) Manually reconfigure the default VLT MAC address. 5 (Optional) Configure a - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 525
RSTP configuration Only RSTP mode is supported on VLT ports. Before you configure VLT on peer switches, configure RSTP in the network. RSTP prevents loops during the VLT startup phase. • Enable RSTP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 526
Create VLT domain A VLT domain requires an ID number. Configure the same VLT domain ID on both peers, see VLT domain. The no vlt-domain command disables VLT. 1 Configure a VLT domain and enter VLT-DOMAIN mode. Configure the same VLT domain ID on each peer, from 1 to 255. vlt-domain domain-id 2 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 527
routing VLT unicast routing enables optimized routing where packets destined for the L3 endpoint of the VLT peer are locally routed. VLT unicast routing is supported on IPv4 and IPv6. To enable VLT unicast routing, both VLT peers must be in L3 mode. The VLAN configuration must be symmetrical on both - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 528
VRRP Optimized Forwarding To enable optimized L3 forwarding over VLT, use VRRP Active-Active mode. By default, VRRP Active-Active mode is enabled in the VLAN interfaces. In Active-Sctive mode, each peer locally forwards L3 traffic, resulting in reduced traffic flow over the VLTi. Configure the same - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 529
VLT Peer Unit ID System MAC Address Status IP Address Version 2 90:b1:1c:f4:bc:0a up fda5:74c8:b79e:1::2 1.0 OS10# View VLT role * indicates the local peer OS10# show vlt 1 role VLT Unit ID Role * 1 primary 2 secondary View VLT mismatch - no mismatch OS10# show vlt 1 mismatch - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 530
backup link. OS10(config)# vlt-domain 1 OS10(conf-vlt-1)# backup destination 10.16.151.110 OS10(config)# vlt-domain 1 OS10(conf-vlt-1)# backup destination ipv6 1::1 Supported Releases 10.3.1E or later 530 Virtual link trunking - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 531
to the default value. Example OS10(conf-vlt-1)# delay-restore 100 Supported Releases 10.3.0E or later discovery-interface Configures the interface to discover Command Mode VLT-DOMAIN Usage Information The VLT node discovery service auto-LAGs the discovery ports and creates VLTi interfaces. - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 532
the timer, peer-routing is not disabled even when the peer is unavailable. Example OS10(conf-vlt-1)# peer-routing-timeout 120 Supported Releases 10.3.0E or later show spanning-tree virtual-interface Displays details of STP information specific to VLT. Syntax Parameters Default Command - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 533
channel1000 : up VLT Peer Unit ID System MAC Address Status IP Address Version 2 90:b1:1c:f4:bc:0a up fda5:74c8:b79e:1::2 1.0 Supported Releases 10.2.0E or later show vlt backup-link Displays the details of heartbeat status. Syntax show vlt domain-id backup-link Parameters domain-id - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 534
137 ---------MAC 00:00:00:00:00:02 is missing from Node(s) 2 Run "show vlt d1 mismatch ..." commands to identify configuration issues Supported Releases 10.2.0E or later show vlt mismatch Displays mismatches in a VLT domain configuration. Syntax show vlt id mismatch [peer-routing | vlan | vlt - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 535
(mismatch VLT VLAN) OS10# show vlt 1 mismatch vlt-vlan VLT ID : 1 VLT Unit ID Mismatch VLAN List * 1 1 2 2 VLT ID : 2 VLT Unit ID Mismatch VLAN List * 1 1 2 2 Supported Releases 10.2.0E or later Virtual link trunking 535 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 536
The * in the mismatch output indicates a local node entry. Example OS10# show vlt 1 role VLT Unit ID Role * 1 primary 2 secondary Supported Releases 10.2.0E or later show vlt vlt-port-detail Displays detailed status information about VLT ports. Syntax Parameters Default Command Mode - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 537
occurs on VLT peers, the VLTi link between peers does not activate. The no version of this command disables VLT. Example OS10(config)# vlt-domain 1 Supported Releases 10.2.0E or later vlt-port-channel Configures the ID used to map interfaces on VLT peers into a single VLT port-channel. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 538
Example OS10(conf-vlt-1)# vlt-mac 00:00:00:00:00:02 Supported Releases 10.2.0E or later vrrp mode active-active Enables the VRRP peers to locally applicable only for VLAN interfaces. OS10(conf-if-vl-10)# vrrp mode active-active Supported Releases 10.2.0E or later 538 Virtual link trunking - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 539
10 Converged data center services OS10 supports converged data center services, including IEEE 802.1 data center bridging (DCB from a transmitting device. The 802.1p priority is also known as the class of service (CoS) or dot1p priority value. When PFC detects congestion of a dot1p traffic class, - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 540
supported for 802.1p priority traffic (dot1p 0 to 7). FCoE traffic traditionally uses dot1p priority 3 - iSCSI storage traffic uses dot1p priority 4. • Configure PFC for ingress traffic by using network-qos class and policy maps (see Quality of Service class-trust class instructs OS10 interfaces to - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 541
notes to change the default settings. Configuration steps: 1 Create PFC dot1p traffic classes. 2 Configure ingress buffers for PFC traffic. 3 Apply a service policy and enable PFC. 4 (Optional) Configure the PFC shared buffer for lossless traffic. Create PFC dot1p traffic classes Converged data - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 542
thresh-mode {static kilobytes | dynamic weight} 6 (Optional) Repeat Steps 2-4 to configure PFC on additional traffic classes. Apply service policy and enable PFC 1 Apply the PFC service policy on an ingress interface or interface range in INTERFACE mode. interface ethernet node/slot/port:[subport - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 543
OS10(config-pmap-c-nqos)# pause OS10(config-pmap-c-nqos)#pfc-cos 4 OS10(config-pmap-c-nqos)#exit OS10(config)# interface ethernet 1/1/1 OS10(conf-if-eth1/1/1)# service-policy input type network-qos pp1 OS10(conf-if-eth1/1/1)# priority-flow-control mode on OS10(conf-if-eth1/1/1)# no shutdown View PFC - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 544
thresholds vary according to the interface type. The default egress buffer reserved for PFC traffic classes is 0 on all interface types. 544 Converged data center services - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 545
-qos)# class cc1 OS10(conf-pmap-c-nqos)# pause buffer-size 30 pause-threshold 20 resumethreshold 10 Supported Releases 10.3.0E or later pfc-cos Configures the matching dot1p values used to send PFC pause frames class map used to define the PFC traffic class (see Converged data center services 545 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 546
type network-qos pp1 OS10(conf-pmap-network-qos)# class cc1 OS10(conf-pmap-c-nqos)# pfc-cos 3 Supported Releases 10.3.0E or later pfc-shared-buffer-size Configures the amount of shared buffers available for PFC- conf-if-eth1/1/1)# priority-flow-control mode on 546 Converged data center services - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 547
-network-qos)# class cc1 OS10(conf-pmap-c-nqos)# queue-limit thresh-mode static 1024 Supported Releases 10.3.0E or later show interface priority-flow-control Displays PFC operational status, configuration 15 Admin Mode : true Operstatus: true PFC Priorities: 3 Converged data center services 547 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 548
priority group to rate-limit best-effort LAN traffic. ETS configuration notes • ETS is supported on L2 802.1p priority (dot1p 0 to 7) and L3 DSCP (0 to 63) lossless queues. • Ingress trust policy - Configure a service policy to trust dot1p values in ingress traffic. 548 Converged data center - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 549
from DCBX TLVs. • The CEE/IEEE2.5 versions of ETS TLVs are supported. ETS configurations are received in a TLV from a peer. Configure ETS traffic-class queue-map-name queue {0-7} qos-group {0-7} exit 3 Create a service policy for the class-trust class in CONFIGURATION mode. Enter POLICY-CLASS-MAP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 550
-policy input type qos trust-policy-map-name 8 Apply the queuing policy to egress traffic in SYSTEM-QOS or INTERFACE mode. service-policy output type queuing policy-map-name 9 Enable ETS globally in SYSTEM-QOS mode or on an interface/interface range in INTERFACE mode. ets mode - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 551
ets mode on OS10(config-sys-qos)# service-policy input type qos pclass1 OS10(config-sys-qos)# service-policy output type queuing p1 View ETS of this command disables ETS. OS10(config-sys-qos)# ets mode on Supported Releases 10.3.0E or later Data center bridging eXchange DCBX allows a switch - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 552
, and iSCSI configurations. • DCBX is enabled by default on OS10 interfaces. You can manually reconfigure DCBX settings on a per-interface basis. For example, you can disable DCBX on because some DCB features support asymmetric (non-identical) configurations. 552 Converged data center services - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 553
must be enabled at both the global and interface levels. You can manually reconfigure DCBX settings or disable DCBX on a per-interface basis. ethernet1/1/15 Port Role is Manual DCBX Operational Status is Enabled Is DCBX Max Version Supported is 0 Sequence Number: 14 Acknowledgment Number: 5 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 554
OS10# show lldp dcbx interface ethernet 1/1/15 ets detail Interface ethernet1/1/15 Max Supported PG is 8 Number of Traffic Classes is 8 Admin mode is on Admin Parameters SP 5 0% SP 6 0% SP 7 0% SP 15 0% SP Remote Parameters Remote is enabled 554 Converged data center services - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 555
a switch, you can re-enable it to ensure consistent operation of peers in a converged data center network. Example OS10(config)# dcbx enable Converged data center services 555 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 556
Supported same command. OS10(conf-if-eth1/1/2)# dcbx tlv-select ets-conf pfc Supported Releases 10.3.0E or later dcbx version Configures the DCBX version used on the DCBX version. OS10(conf-if-eth1/1/2)# dcbx version cee Supported Releases 10.3.0E or later lldp tlv-select dcbxp Enables and - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 557
DCBX on an interface. OS10(conf-if-eth1/1/1)# lldp tlv-select dcbxp Supported Releases 10.3.0E or later show lldp dcbx interface Displays DCBX configuration disabled Interface ethernet1/1/15 Port Role is Manual DCBX Operational Status is Enabled Is Configuration data center services 557 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 558
Example (PFC detail) Max Supported PG is 8 Number of Traffic Classes is 8 Admin mode is on Admin Parameters Admin is enabled PG-grp Priority# Bandwidth TSA 0 0,1,2,3 70% Oper status is init PFC DCBX Oper status is Up State Machine Type is Symmetric 558 Converged data center services - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 559
to switch ports. To support storage arrays where auto-detection is not supported, manually configure iSCSI optimization. iSCSI optimization information and iSCSI session information. • A user-configured iSCSI class of service (CoS) profile is applied to all iSCSI traffic. Classifier rules are used - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 560
configures switch parameters after connection to a storage device is verified. You must manually enable an interface to support a storage device that is directly connected to a port, but not automatically detected storage arrays in a network using iSCSI commands. 560 Converged data center services - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 561
by iSCSI. Use this command for storage devices that do not support LLDP. In this release, the only valid storage-device-name value 6 Configure the QoS policy applied to the ingress iSCSI flows. Apply the service policy to ingress interfaces in CONFIGURATION mode. (Optional) Reset the default CoS - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 562
minutes - Enter the aging time in minutes allowed for monitoring iSCSI sessions (5 to 43,200). Default 10 minutes Command Mode CONFIGURATION 562 Converged data center services - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 563
Enter only one dot1p-bitmap value - setting more than one bitmap value with this command is not supported. The default dot1p 4 value is advertised only if you enabled PFC pause frames for dot1p 4 traffic of a storage array that iSCSI does not automatically detect. Converged data center services 563 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 564
supported by iSCSI if they are not automatically detected. This command is required for storage devices that do not support -storage compellant Supported Releases 10.3.0E iscsi session-monitoring enable Supported Releases 10.3.0E or Supported Releases 10.3.0E or later 564 Converged data center - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 565
. OS10(conf-if-eth1/1/1)# lldp tlv-select dcbxp-appln iscsi Supported Releases 10.3.0E or later show iscsi Displays currently configured iSCSI of connections is 256 Port IP Address 3260 860 3261 10.1.1.1 Supported Releases 10.3.0E or later show iscsi session Displays information about - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 566
IP Address TCP Port ID 10.10.10.210 54835 10.10.10.40 3260 1 Supported Releases 10.3.0E or later show iscsi storage-devices Displays information about the storage arrays directly attached avoid dropped frames, retransmission, and network congestion. 566 Converged data center services - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 567
storage traffic using: • Separate traffic classes for the different service needs of network applications. • PFC flow control to pause data • iSCSI application protocol TLV information in DCBX advertisements to communicate iSCSI support to peer ports This example shows how to configure a sample DCB - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 568
-pmap-c-qos)# end 5. ETS configuration (interface and global) Apply the service policies with dot1p trust and ETS configurations to an interface or on all switch interfaces. Only one qos-map traffic-class map is supported on a switch. OS10(config)# interface ethernet 1/1/53 OS10(conf-if-eth1 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 569
qos-map traffic-class tmap2 OS10(config-sys-qos)# service-policy input type qos pclass OS10(config-sys-qos)# service-policy output type queuing pmap1 OS10(config-sys-qos)# for iSCSI disabled Interface ethernet1/1/53 Port Role is Manual DCBX Operational Status is Enabled Is Configuration Source? - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 570
(conf-if-eth1/1/53)# do show lldp dcbx interface ethernet 1/1/53 ets detail Interface ethernet1/1/53 Max Supported PG is 8 Number of Traffic Classes is 8 Admin mode is on Admin Parameters Admin is enabled TLV Pkts, 27 Output Reco TLV Pkts, 0 Error Reco TLV Pkts 570 Converged data center services - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 571
-pmap-c-app)# set cos 6 OS10(config-pmap-c-app)# exit OS10(config-pmap-application)# exit OS10(config)# system qos OS10(config-sys-qos)# service-policy type application policy-iscsi OS10(config-sys-qos)# exit OS10(config)# iscsi session-monitoring enable OS10(config)# iscsi priority-bits 0x40 OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 572
ethernet1/1/53 Port Role is Manual DCBX Operational Status is Enabled Is Status DCBX Operational Version is 0 DCBX Max Version Supported is 0 Sequence Number: 2 Acknowledgment Number: version ieee service-policy input type network-qos test service-policy input type qos pclass service-policy output - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 573
iSCSI enabled i-Application Priority for iSCSI disabled Interface ethernet1/1/53 Port Role is Manual DCBX Operational Status is Enabled Is Configuration Source? FALSE Local DCBX Compatibility mode 0 Total DCBX Frame errors 0 Total DCBX Frames unrecognized 0 Converged data center services 573 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 574
traffic monitoring for high-speed networks with many switches and routers. • OS10 supports sFlow version 5 • sFlow collector is supported only on data ports • A maximum of two sFlow collectors • OS10 does not support sFlow on SNMP, VLAN, VRF, tunnel interfaces, extended sFlow, backoff mechanism, and - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 575
sFlow maximum header size OS10(config)# sflow max-header-size 80 View sFlow information OS10# show sflow sFlow services are enabled Management Interface sFlow services are disabled Global default sampling rate: 32768 Global default counter polling interval: 20 Global default extended maximum header - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 576
sFlow polling interval OS10(config)# sflow polling-interval 200 View sFlow information OS10# show sflow sFlow services are enabled Management Interface sFlow services are disabled Global default sampling rate: 32768 Global default counter polling interval: 200 Global default extended maximum - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 577
View sFlow information The current release does not support the statistics for UDP packets dropped. • View sFlow configuration details and statistics in EXEC mode. OS10# show sflow sFlow services are enabled Management Interface sFlow services are disabled Global default sampling rate: 32768 Global - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 578
no version of this command removes the configured sFlow collector. Example OS10(conf)# sflow collector 10.1.1.1 agent-addr 2.2.2.2 6343 max-datagram-size 1500 vrf default Supported Releases 10.3.0E or later 578 sFlow - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 579
Use the no version of the command to reset the header size to the default value. OS10(conf)# sflow max-header-size 256 Supported Releases 10.3.0E or later sflow polling-interval Sets the sFlow polling interval. Syntax Parameter sflow polling-interval interval-value interval-value - Enter - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 580
port-channel for the interface type. EXEC OS10 does not support statistics for UDP packets dropped and samples received from the hardware. Example OS10# show sflow sFlow services are enabled Management Interface sFlow services are disabled Global default sampling rate: 32768 Global default counter - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 581
0 UDP packets dropped 34026 sFlow samples collected Example (portchannel) OS10# show sflow interface port-channel 1 port-channel1 sFlow is enabled on port-channel1 Samples rcvd from h/w: 0 Supported Releases 10.3.0E or later sFlow 581 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 582
OS10 Critical workloads and applications require constant availability. Dell EMC Networking offers tools to help you monitor and troubleshoot problems before they happen. Packet and flow capture Metrics measurement Analysis and reporting Alerting Logging Performance monitoring Mapping and - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 583
TIME+ COMMAND 9 root 20 0 0 0 0 S 6.1 0.0 5:22.41 rcuos/1 819 snmp 20 0 52736 6696 4132 S 6.1 0.2 2:44.18 snmpd 30452 admin 20 0 22076 2524 2100 R 6.1 0.1 0:00.02 top Troubleshoot OS10 583 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 584
captured packets to a file, use the -w parameter. To read the captured file output offline, you can use open source software packages such as wireshark. 584 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 585
a destination and wait for a response. If there is no response, the destination is not active. The ping command is useful during configuration if you have problems connecting to a hostname or IP address. Troubleshoot OS10 585 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 586
abort Tracing the route to 3ffe:501:ffff:100:201:e8ff:fe00:4c8b, 64 hops max, 60 byte packets Hops Hostname Probe1 Probe2 Probe3 586 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 587
Service-tag : 5XYK0Z1 Power Supplies PSU-ID AirFlow PPID 1 NORMAL CN0T9FNW2829852R026 2 NORMAL CN0T9FNW2829852R026 Fantrays FanTray-ID AirFlow PPID 1 NORMAL CN0MGDH82829852R039 2 NORMAL CN0MGDH82829852R039 3 NORMAL CN0MGDH82829852R039 Troubleshoot - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 588
location-led interface command to change the location LED for the specified interface. OS10# location-led interface ethernet 1/1/1 on OS10# location-led interface ethernet 1/1/1 off Supported Releases 10.3.0E or later 588 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 589
system ID. OS10# location-led system 1 on OS10# location-led system 1 off Supported Releases 10.3.0E or later ping Tests network connectivity to an IPv4 device. Syntax Parameters . • For a port-channel interface, enter port-channelchannel-id; for example, port-channel1. Troubleshoot OS10 589 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 590
to fill out the packet you send to diagnose data-related problems in the network (for example, -p ff fills the sent packet up to 1500 bytes in decimal or hex) to set quality of service (QoS)-related bits. • -s packetsize - (Optional) Enter the Supported Releases 10.2.0E or later 590 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 591
pad bytes to fill out the packet you send to diagnose data-related problems in the network (for example, -p ff fills the sent packet with all (up to 1500 bytes in decimal or hex) to set quality of service (QoS)-related bits. • -s packetsize - (Optional) Enter the number Troubleshoot OS10 591 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 592
loss, time 3005ms rtt min/avg/max/mdev = 2.078/2.194/2.379/0.127 ms Supported Releases 10.2.0E or later show boot Displays boot partition-related information. Syntax Parameters Default Current system image information detail: Type: Node-id 1 Boot Type: Flash Boot 592 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 593
03T23:11:14Z A 10.2.0E 2016-10-03T23:11:14Z active[B] Supported Releases 10.2.0E or later show diag Displays diagnostic information for port adapters .1 Ethernet controller: Broadcom Corporation Device b340 (rev 01) Supported Releases 10.2.0E or later show environment Displays information about - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 594
temp sensor 21 1 3 Ambient temp sensor 24 1 4 NPU temp sensor 43 Supported Releases 10.2.0E or later show hash-algorithm Displays hash algorithm information. Syntax Parameters Default : 10.2.9999E Unit Type Part Number Rev Piece Part ID 594 Troubleshoot OS10 Svc Tag Exprs Svc C - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 595
410 1 S6000-ON-FANTRAY-3 0MGDH8 A00 CN-0MGDH8-28298-52R-0392 AEIOU## 226 457 410 Supported Releases 10.2.0E or later show processes View process CPU utilization information. Syntax Parameters show processes node PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND Troubleshoot OS10 595 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 596
1019 root OS10# Supported Releases 10.3.0E or later 20 0 1829416 256080 73508 S 6.6 6.4 1212:36 base_nas show system Displays system information. Syntax 7168 up 3 up NORMAL 1 7149 up 2 7104 up Example (node-id) OS10# show system node-id 1 fanout-configured 596 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 597
-- FanTray Status AirFlow Fan Speed(rpm) Status 1 up NORMAL 1 6710 up 2 7136 up 2 up NORMAL 1 6767 up 2 7155 up 3 up NORMAL 1 6785 up 2 7040 up Supported Releases 10.2.0E or later Troubleshoot OS10 597 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 598
out simultaneously to accelerate traceroute (default 16). • -t tos - (Optional) For IPv4, enter the Type of Service (TOS) and Precedence values to use. 16 sets a low delay; 8 sets a high throughput. • -UL GigabitEthernet3-3.GW3.SCL2.ALTER.NET (152.179.99.173) 4.428 ms 2.593 598 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 599
(20::1), 30 hops max, 80 byte packets 1 20::1 (20::1) 2.622 ms 2.649 ms 2.964 ms Supported Releases 10.2.0E or later Password recovery You may need to recovery your lost password. 1 Connect to the serial installed operating system and requires a long time to erase storage. Troubleshoot OS10 599 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 600
: /dev/mmcblk0 (7832MB) Percent complete: 100% SupportAssist By default, SupportAssist is enabled. SupportAssist sends troubleshooting data securely to Dell Technical Support. SupportAssist does not support automated email notification at the time of hardware fault alert, automatic case creation - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 601
) which would be used to provide technical support for your Dell products and services. Dell may use the information for providing Support to identify which company owns the device. 1 (Optional) Configure contact information in SUPPORT-ASSIST mode. contact-company name name Troubleshoot - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 602
time zone. SupportAssist contact-person configurations are optional for the SupportAssist service. 1 (Optional) Enter the contact name in SUPPORT-ASSIST mode. contact-person first firstname last lastname 2 Enter the email yearly task (1 to 12, 1 to 31, 0 to 23, and 0 to 59). 602 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 603
Display the EULA license agreement in EXEC mode. show support-assist eula View SupportAssist status OS10# show support-assist status EULA : Accepted Service : Enabled Contact-Company : DellCMLCAEOS10 Street Address : 7625 Sep 12,2016 20:30:28 Sep 12,2016 20:30:52 Troubleshoot OS10 603 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 604
save your contact information (e.g. name, phone number and/or email address) which would be used to provide technical support for your Dell products and services. Dell may use the information for providing recommendations to improve your IT infrastructure. Dell SupportAssist also collects and stores - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 605
Usage Information Example email-address address address - Enter the email address for the contact name. Not configured SUPPORT-ASSIST The no version of this command removes the configuration. OS10(conf-support-assist-Eureka-JohnJamesSmith)# email-address [email protected] Troubleshoot OS10 605 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 606
Accepts or rejects the SupportAssist end-user license agreement (EULA). Syntax Parameters eula-consent {support-assist} {accept | reject} • support-assist - Enter to accept or reject the EULA for the service. • accept - Enter to accept the EULA-consent. • reject - Enter to reject EULA-consent - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 607
and/or email address) which would be used to provide technical support for your Dell, Inc. products and services. Dell, Inc. may use the information for providing recommendations to IP addresses, access control lists, diagnostics & performance information, network configuration Troubleshoot OS10 607 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 608
Default Not configured Command Mode EXEC Example OS10# show support-assist status EULA : Accepted Service : Enabled Contact-Company : DellCMLCAEOS10 Street Address : Activity State coredump-transfer enabled event-notification enabled full-transfer enabled 608 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 609
51:51 full-transfer success Sep 12,2016 20:30:28 Sep 12,2016 20:30:52 Supported Releases 10.2.0E or later street-address Configures the street address information for the company. Syntax Parameters hour to schedule the task (0 to 59). • yearly - Schedule the yearly task: Troubleshoot OS10 609 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 610
collects Linux system configuration and diagnostics information, as well as show command output to send to Dell Technical Support. To send Dell Technical Support troubleshooting details about the Linux system configuration and OS10 diagnostics, generate an sosreport tar file. 1 Generate the tar file - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 611
output collection task completed; sosreport execution task started:All Plugin options enabled Support bundle generation successful event Apr 19 17:0:9: %Node.1-Unit.1:PRI:OS10 hardware components have failed, or one or more hardware components exceeds temperature thresholds. Troubleshoot OS10 611 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 612
A minor error or non-critical condition occurred that, if left unchecked, might cause system service interruption or performance degradation. A minor alarm requires monitoring or maintenance. • Informational - An any logging command in CONFIGURATION mode. no logging enable 612 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 613
OS10# show logging log-file Jun 1 05:01:46 %Node.1-Unit.1:PRI:OS10 %log-notice:ETL_SERVICE_UP: ETL service is up Jun 1 05:02:06 %Node.1-Unit.1:PRI:OS10 %log-notice:EQM_UNIT_DETECTED: Unit pres ent:Unit 1# dn_dot1x dn_eqa dn_eqm dn_eth_drv dn_etl dn_i3 dn_ifm dn_infra_afs Troubleshoot OS10 613 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 614
show running-configuration link-bundle-trigger-threshold 10 ! ... Show link-bundle utilization OS10(config)# do show link-bundle-utilization Link-bundle trigger threshold - 10 614 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 615
alarm index command to view a list of alarm IDs. OS10# alarm clear 200 Supported Releases 10.2.0E or later show alarms Displays all current active system alarms. Syntax 11 Node.1-Unit.1 Sep 7 18:36:11 Node.1-Unit.1 Supported Releases 10.2.0E or later show alarms details Displays details about - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 616
Raise-time: Sep 20 0:16:52 Clear-time: New: true State: raised Supported Releases 10.2.0E or later show alarms history Displays the history of cleared alarms. Summary Total-count: 0 Critical-count: 0 Major-count: 0 Minor-count: 0 Warning-count: 0 616 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 617
Raise-time: Sep 20 0:16:52 Clear-time: New: true State: raised Supported Releases 10.2.0E or later show alarms severity Displays all active alarms using the severity Active-alarm details - 1 Index: 1 Sequence Number: 5 Severity: warning Type: 1081364 Troubleshoot OS10 617 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 618
-time: Sep 20 0:1:5 Clear-time: New: true State: raised Supported Releases 10.2.0E or later show alarms summary Displays the summary of 6 Critical-count: 0 Major-count: 2 Minor-count: 2 Warning-count: 2 Supported Releases 10.2.0E or later Logging commands 618 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 619
logging log-file Proceed to clear the log file [confirm yes/no(default)]: Supported Releases 10.2.0E or later logging console Disables, enables, or configures the minimum (Severity) OS10(config)# logging console severity log-warning Supported Releases 10.2.0E or later Troubleshoot OS10 619 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 620
The no version of this command disables all logging. OS10(config)# logging enable Supported Releases 10.2.0E or later logging log-file Disables, enables, or sets the Example (Severity) OS10(config)# logging log-file severity log-notice Supported Releases 10.2.0E or later 620 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 621
Log-notice CONFIGURATION None OS10(config)# logging monitor severity log-info Supported Releases 10.2.0E or later logging server Configures the remote syslog - Normal but significant conditions (default). • log-info - Informational messages. • log-debug - Debug messages. Troubleshoot OS10 621 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 622
dn_system_mgmt_ dn_env_tmpctl dn_pm dn_eth_drv dn_etl dn_eqa dn_alm dn_eqm dn_issu dn_swupgrade dn_ifm dn_ppm dn_l2_services dn_dot1x dn_l3_core_serv dn_policy dn_qos dn_switch_res_m dn_ospfv3 dn_lacp dn_i3 dn_supportassis --More-- Supported Releases 10.2.0E or later 622 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 623
(23 59319) May 23 17:10:08 OS10 base_nas: [NETLINK:NHEVENT]:ds_api_linux_neigh.c:nl_to_nei --More-- Supported Releases 10.2.0E or later Log into OS10 device Linux shell access is available for troubleshooting and diagnostic purposes only. Use linuxadmin for both the default user name and password - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 624
and variables, or as instructed by Dell Support. OS10 login: linuxadmin Password contains information about how to add users, troubleshoot RADIUS, how to view current DHCP information on. • Quality of service contains information about quality of service including classification and marking, - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 625
specific device? See the Getting Started Guide shipped with your device or the platform-specific Installation Guide on the Dell Support page (see dell.com/ support). Hardware What are the default console configuration changes prior to applying them to the running- configuration Troubleshoot OS10 625 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 626
? Use the username commands to add new users. Use the show users command to view a list of current users. How do I view RADIUS transactions to troubleshoot problems? Use the debug radius command. How do I view the current DHCP binding information? Use the show ip dhcp binding command. Layer 2 How do - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 627
view the currently running software version. How can I troubleshoot SNMP operation? Use the show ip traffic command to -group information? Use the show access-group and show access-list commands. Quality of service What are the QoS error messages? Flow control error messages: • Error: priority-flow - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 628
else reconfigure the pause buffers Monitoring How can I check if SupportAssist is enabled? Use the show support-assist status command to view current configuration information. How can I view a list of alarms? Use logging command to view messages by log-file or process name. 628 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.1E - Page 629
tag or express service code, pull out the luggage tag on the chassis or enter the show chassis command from the CLI. • To receive additional kinds of technical support, click Contact Us, then click Technical Support. To access system documentation, see www.dell.com/manuals/. To search for drivers
OS10 Enterprise Edition User Guide