- Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 1
Dell Neworking S6000-Open Networking (ON) Installation Guide January 2017 - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 2
use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2017 Dell Inc. or its subsidiaries. All rights reserved - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 3
Contents 1 About this guide...5 Information symbols...5 Related documents...5 2 The S6000-ON system...6 Introduction...6 Features...7 Physical dimensions...7 Ports...8 System status...8 LED display...8 LED behavior...9 Prerequisite...9 Orderable S6000-ON components...10 3 - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 4
...38 Safety standards and compliance agency certifications 38 Electromagnetic compatibility (EMC)...38 Product recycling and disposal...39 10 Technical support...40 Dell support...40 Accessing iSupport Services...40 Technical assistance center...40 Hardware replacement request...41 4 Contents - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 5
Read this guide before you install and power up this equipment. This equipment contains two power cords. Disconnect both power cords before servicing. WARNING: S6000-Open Networking (ON) Getting Started Guide. NOTE: For the most recent documentation, visit the Dell EMC support page at www.dell.com - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 6
2 The S6000-ON system The following sections describe the Dell EMC S6000-ON system. Topics: • Introduction • Features • Physical dimensions • Ports • System status • LED display • Prerequisite • Orderable S6000-ON components Introduction The S6000-ON is a one rack unit (RU) full-featured 10 GbE and/ - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 7
Two hot-plug redundant power supplies • Three removable fan modules • Temperature monitoring • Software-readable thermal monitor • Real-time clock (RTC) support • Current monitoring for power management • Standard 1U chassis high Physical dimensions The S6000-ON has the following physical dimensions - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 8
Ports The S6000-ON offers the following ports. • Serial RS-232 port (RJ-45 type) • Out of band (OOB) Ethernet management port (RJ-45 type) • Thirty-two 40 Gbps QSFP+ ports • One universal serial bus port (USB Type-A) System status You can view S6000-ON status information using the light emitting - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 9
locator function is enabled Prerequisite The following is a list of components required for a successful installation of the S6000-ON. NOTE: Detailed installation instructions for the S6000-ON are provided in Site Preparations and Install the S6000-ON. • S6000-ON chassis • AC cables to connect the - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 10
• Copper/fiber cables Other optional components are: • Additional power supply unit • Additional fan module • Additional mounting brackets (if installing in a four-post rack or cabinet) Orderable S6000-ON components You can order the S6000-ON system in several configurations. You can also order - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 11
• Fans and airflow • Power • Storing components Site selection Install Dell EMC equipment in restricted access areas. A restricted access area is one where service personnel can only gain access using a special tool, lock, key or other means of security and access is controlled by the authority - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 12
ground. Ground the equipment rack to the same ground point the power service in your area uses. The ground path must be permanent. Grounding -ON chassis. Fan combinations The S6000-ON has stock keeping units (SKUs) that support the following configurations: • AC PSU with fan airflow from I/O to PSU • - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 13
Storing components If you do not install your S6000-ON and components immediately, properly storing the system and all optional components. WARNING: ESD damage can occur when components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the S6000-ON and its - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 14
4 NEBS compliance For your system to be network equipment building system (NEBS) compliant, you must follow the instructions detailed in this section. To be NEBS compliant, orient your system in the rack so that the air inlet is from the front aisle and - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 15
-no tools required • Two PSUs • At least one country/region-specific AC power cord • S6000-ON Getting Started Guide • Safety and Regulatory Information • Warranty and Support Information Unpacking Steps 1 Place the container on a clean, flat surface and cut all straps securing the container. 2 Open - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 16
and two rails that are shipped attached to the sides of the switch. WARNING: This is a condensed reference. Read the safety instructions in your Safety, Environmental, and Regulatory information booklet before you begin. NOTE: The illustrations in this document are not intended to represent - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 17
Figure 6. 1U tool-less configuration 2 Align and seat the front flange pegs in the holes on the front side of the vertical post, item 2. 3 Repeat this procedure for the second rail. 4 To remove each rail, pull on the latch release button on each flange ear and unseat each rail, item 3. Two-post - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 18
Figure 7. Two-post flush-mount configuration 2 Attach one rail to the front post flange with two user-supplied screws, item 2. 3 Slide the plunger bracket forward against the vertical post and secure the plunger bracket to the post flange with two user-supplied screws, item 3. 4 Repeat this - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 19
Figure 8. Two-post center-mount configuration 2 Slide the back bracket towards the post and secure it to the post flange with two user-supplied screws, item 2. 3 Repeat this procedure for the second rail. Four-post threaded configuration CAUTION: To be NEBS Earthquake Z4-compliant, you must remove - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 20
Figure 9. Four-post threaded configuration 2 Attach the front and rear flanges for each rail to the post flanges with two user-supplied screws at each end, item 2. S6000-ON system installation You can mount the system in the 1U front-rack, four-post or two-post configurations. The following is an - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 21
Figure 10. Attaching the Switch Rails 2 After you have installed both switch rails, line them up on the previously mounted Ready-Rails and slide the switch in until it is flush with front of rack. About three inches prior to full insertion, the rail locking feature engages to keep the switch from - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 22
Ground cable attachment Dell EMC recommends you ground your system. To attach the ground cable to the chassis, use a single M4x0.7 screw. The cable itself is not included with the S6000-ON. To properly ground the chassis, use a 6AWG one-hole lug, #10 hole size, 63" spacing, not included in shipping. - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 23
• the input circuits are correctly sized for the loads and that you use sufficient overcurrent protection devices. • all protective covers are in place. • blank panels are installed if you do not install optional modules. NOTE: A US AC power cable is included for powering up an AC power supply. You - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 24
two hot-swappable PSUs with integrated fans that provide cooling for the system. The S6000-ON supports AC power supplies with two air-flow directions-I/O to PSU and PSU to I/O. Two PSUs are required for full redundancy, but the system can operate - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 25
3 PSU 2 The PSUs are in a single piece with the PSU fans. You can replace the fan trays individually, but you cannot replace the fans that are attached to the PSUs. If the fans attached to the PSU fail, you must replace the entire PSU. For fan tray replacement procedures, see Fans. WARNING: Prevent - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 26
PSU or the S6000- ON chassis. NOTE: If a PSU fails, you must replace the entire unit. There are no field serviceable components in the PSU. To request a hardware replacement, see Technical Support. NOTE: If you use a single PSU, install a blank plate in the other PSU slot. Dell EMC recommends using - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 27
S6000-ON system installation To configure your system, after you have securely installed and powered on the S6000-ON, see your open network installation environment (ONIE)-compatible third-party operating system documentation at http://onie.org. Power supplies 27 - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 28
7 Fans The S6000-ON comes from the factory two PSU and three fan modules installed in the chassis. The S6000-ON has SKUs that support the following configurations. • AC PSU with fan airflow from I/O to PSU • AC PSU with fan airflow from PSU to I/O All fans and PSUs in a configuration - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 29
Fan module installation The fan modules in the S6000-ON are field replaceable. Module slot 0 is on the left side of the chassis; module slot 1 is on the right side of the chassis. CAUTION: DO NOT mix airflow directions. Both fans must use the same airflow direction-reverse or normal. 1 Take the fan - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 30
8 Management ports Besides the 10 GbE and 40 GbE switch ports, the S6000-ON provides several ports for management and storage. Topics: • RS-232 console port access • USB-B console port access • Before you install an OS system • USB storage RS-232 console port access The RS-232 console port is on the - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 31
• 8 data bits • 1 stop bit • No flow control Accessing the Console Port To access the console port, use the following steps. 1 Install the provided RJ-45 connector side of the provided copper cable into the S6000-ON console port. 2 Install the DB-9 female side of the provided copper cable into your - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 32
necessary USB device drivers. You need an internet connection. For assistance, contact Dell Networking Technical Support. 6 Open your terminal software emulation program to access the S6000-ON. 7 Keep the from a URL Starts ONIE with ONIE Discovery Service (factory default boot) 32 Management ports - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 33
Example of the ONIE ifconfig eth0 Command If none of the ONIE Service Discovery methods are successful, you can disable is using the onie-discovery-stop command. You can install an operating system manually from HTTP, FTP, or TFTP using the onie-nos-install command. The ONIE - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 34
USB storage USB storage does not automatically mount. The supported file system is FAT. To use USB storage, first mount the device. 1 Create a mount directory for the USB. ONIE:/ # mkdir /mnt/usb 2 View the fixed - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 35
incorrectly replaced. Replace only with same or equivalent type of battery. Dispose of the batteries according to the manufacturer's instructions. Topics: • Chassis physical design • IEEE standards • Agency compliance Chassis physical design Table 2. Chassis physical design Parameter Height Width - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 36
environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance to the instructions, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 37
Control Council For Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. Figure 19. VCCI compliance label Specifications 37 - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 38
2nd Edition • EN 60950-1, 2nd Edition • EN 60825-1, 1st Edition • EN 60825-1 Safety of Laser Products-Part 1: Equipment Classification Requirements and User's Guide • EN 60825-2 Safety of Laser Products-Part 2: Safety of Optical Fibre Communication Systems • FDA Regulation 21CFR 1040.10 and 1040.11 - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 39
needed. Dell Networking offers a variety of product return programs and services in several countries to assist equipment owners in recycling their IT product recycling offerings, see the WEEE Recycling instructions on Support. For more information, contact the Dell Technical Assistance Center (TAC). - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 40
you do not have a userid and password, you can request these at the website. To request a userid, password, and iSupport services, follow these steps. 1 On the Dell Networking Support page, click the Account Request link. 2 Fill out the User Account Request form and click Send. You will receive your - Dell PowerSwitch S6000 ON | Neworking S6000-Open Networking ON Installation Guid - Page 41
in the chassis, use the show hardware command. 2 Request an RMA number from TAC by opening a support case. Open a support case by: • Using the Create Service Request form on the Support page. • Contacting Dell EMC directly by email or by phone. • Provide the following information when using
Dell Neworking S6000–Open Networking (ON)
Installation Guide
January 2017