Dell PowerSwitch S6000 ON OS10 Enterprise Edition User Guide Release 10.3.0E
Dell PowerSwitch S6000 ON Manual
View all Dell PowerSwitch S6000 ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell PowerSwitch S6000 ON manual content summary:
- Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 1
OS10 Enterprise Edition User Guide Release 10.3.0E - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 2
of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 3
Contents 1 Getting Started...18 Download OS10 image and license...19 Installation...20 Automatic installation...21 Manual installation...21 Log into OS10...22 Install OS10 license...22 Remote access...23 Configure Management IP address...24 Management Route Configuration...24 Configure user name - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 4
feature config-os9-style...45 exit...46 license...46 lock...47 management route...47 move...48 no...48 reload...49 show alias...49 show boot...50 show candidate-configuration...50 show environment...52 show inventory...53 show ip management-route...53 show ipv6 management-route...54 show license - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 5
description (Interface)...74 duplex...74 fec...75 interface breakout...75 interface ethernet...76 interface loopback...76 interface mgmt...76 interface null...77 interface port-channel...77 interface range...77 interface vlan...78 link-bundle-utilization...78 mgmt...79 mtu...79 show interface...80 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 6
Organizationally-specific TLVs...112 Media endpoint discovery...113 Network connectivity device...113 LLDP-MED capabilities TLV...114 Network policies TLVs...115 Define network policies...116 Packet timer values...116 Disable and re-enable LLDP ...117 Advertise TLVs...117 Network policy - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 7
Weight and local preference...197 Multiexit discriminators...198 Origin...198 AS path and next-hop...199 Best path selection...199 More path support...200 Advertise cost...200 4-Byte AS numbers...201 AS number migration...201 Configure border gateway protocol...202 Enable BGP...202 Configure Dual - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 8
Additional paths...212 MED attributes...212 Local preference attribute...213 Weight attribute...214 Enable multipath...214 Route-map filters...215 Route reflector clusters...215 Aggregate routes...216 Confederations...217 Route dampening...217 Timers...219 Neighbor soft-reconfiguration...219 BGP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 9
Troubleshoot OSPF...271 OSPFv3...272 OSPF commands...276 OSPFv3 Commands...300 Object tracking format and options...334 Configure Server...335 Automatic address allocation...336 Hostname resolution...337 Manual binding entries...338 View DHCP Information...339 System domain name and list...339 DHCP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 10
Source IP address...349 Authentication...349 NTP commands...350 System clock...354 System Time and Date Commands...355 Energy-efficient Ethernet...356 Enable energy-efficient Ethernet...356 Clear interface counters...356 View EEE status/statistics...357 EEE commands...357 UFT modes...360 Configure - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 11
Match routes...384 Set conditions...384 continue Clause...385 ACL flow-based monitoring...385 Port-based mirroring...385 Enable flow-based monitoring...386 ACL commands...387 clear ip access-list counters...387 clear ipv6 access-list counters...387 clear mac access-list counters...388 deny...388 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 12
permit (IPv6)...406 permit (MAC)...406 permit icmp...407 permit icmp (IPv6)...408 permit ip...408 permit ipv6...409 permit tcp...409 permit tcp (IPv6)...410 permit udp...411 permit udp (IPv6)...412 remark...412 seq deny...413 seq deny (IPv6)...414 seq deny (MAC)...414 seq deny icmp...415 seq deny - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 13
-type...440 set next-hop...441 set origin...441 set tag...442 set weight...442 show route-map...442 7 Quality of service...444 Configure quality of service...445 Class-map configuration...446 Policy-map configuration...446 Interface policy-map...447 Control-plane policy-map...448 System policy-map - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 14
priority...477 priority-flow-control mode...477 qos-group dot1p...477 qos-group dscp...478 queue-limit...478 queue qos-group...479 random-detect...480 service-policy...480 set cos...481 set dscp...481 set qos-group...481 shape...482 show class-map...482 show control-plane info...483 show control - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 15
show interface priority-flow-control...484 show qos interface...484 show policy-map...485 show qos control-plane...485 show qos egress bufffers interface...486 show egress buffer-stats interface...486 show qos ingress buffers interface...487 show ingress buffer-stats interface...487 show queuing - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 16
9 Converged data center services...510 Priority flow control...510 PFC configuration notes...511 Configure -size...551 sflow polling-interval...551 sflow sample-rate...552 show sflow...552 11 Troubleshoot OS10...554 Diagnostic tools...554 Boot partition and image...555 Monitor processes...555 LED - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 17
Frequently asked questions...596 Installation...597 Hardware...597 Configuration...597 Security...598 Layer 2...598 Layer 3...598 System management...598 Access control lists...599 Quality of service...599 Monitoring...600 12 Support resources...601 Contents 17 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 18
EMC Networking OS10 Enterprise Edition is a network operating system supporting multiple architectures and environments. The networking world is moving from infrastructure • Provides the most up-to-date security fixes which supports a large community of engineers and security experts • Utilizes an - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 19
run beyond the 120-day trial license period. See the Quick Start Guide shipped with your device and My Account FAQs for more information. Download an OS10 entitlement to the service tag of the switch to extend the entitled download period to be the same time as the support contract. OS10 software - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 20
manually, or from a USB device. ONIE supports Manual installation - Manually configure your network information if a DHCP server is not available, or manually Guide shipped with your device or the platform-specific Installation Guide at www.dell.com/support allows for manual installation of manual OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 21
file from, and xxP represents the version number of the software to install. Install OS10 manually with USB drive You can manually install the OS10 software image using USB media. Verify that the USB storage device supports a FAT or EXT2 file system. Plug the USB storage device into the USB storage - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 22
may be trademarks of their respective companies. OS10# Install OS10 license OS10 comes with a 120-day trial license. To continue with uninterrupted service, the installation of a perpetual license is required or the ONIE-enabled device reboots every 72 hours. After you install OS10 and log in - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 23
Name : S4048-ON PPID : CN0M68YC2829855M0133 Service Tag : CFNNX42 License Details Software : OS10-Enterprise Version : 10.3.0E License Type : PERPETUAL License Duration: Unlimited License Status : Active License location: /mnt/license/CFNNX42.lic Troubleshoot license installation failure An error - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 24
Configure Management IP address To remotely access OS10, assign an IP address to the Management port. • Configure the management interface from CONFIGURATION mode. interface mgmt node/slot/port • Configure an IPv4 or IPv6 address on the Management interface in INTERFACE mode. ip address A.B.C.D/mask - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 25
then click Download Now. Install the OS10 image on an ONIE-enabled switch with an installed OS10 license. See Install OS10 license for complete instructions. CLI Basics The OS10 command-line interface (CLI) is the software interface you use to access a device running the software - from the console - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 26
names, usernames, and configuration statements. CLI command modes The OS10 CLI has two top-level modes: • EXEC mode - Used to monitor, troubleshoot, check status, and network connectivity. • CONFIGURATION mode - Used to configure network devices. When you enter CONFIGURATION mode, you are changing - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 27
is a sub-mode of CONFIGURATION mode. Interface mode is where you configure Layer 2 and Layer 3 protocols, and IPv4 and IPv6 services specific to an interface: • Physical interfaces include the Management interface and Ethernet ports • Logical interfaces include loopback, port-channel, and virtual - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 28
balancing logging mac management monitor no ntp policy-map qos-map radius-server parameters route-map router sflow snmp-server spanning-tree support-assist system track trust username To configure AAA Set alias for a command Configure class map Configure clock parameters Control-plane configuration - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 29
-map port-channel processes qos queuing revision route-map running-configuration sessions sflow spanning-tree startup-configuration storm-control support-assist system tech-support terminal trace track Display all current alarm situation in the system Show list of aliases Show boot information - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 30
uptime users the session id version vlan vlt vrrp Show the system uptime Show the current list of users logged into the system , and show Show the software version on the system Vlan status and configuration Show VLT domain info VRRP group status • Enter show command-history from EXEC mode to view - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 31
-list interface lacp lldp logging monitor ospf ospfv3 policy-map prefix-list qos-map radius-server route-map sflow snmp spanning-tree support-assist system-qos trust-map users vlt Current candidate aaa configuration Current candidate access-list configuration Current candidate as-path configuration - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 32
access vlan 1 no shutdown ! interface vlan 1 no shutdown ! interface mgmt1/1/1 ip address dhcp no shutdown ipv6 enable ipv6 address autoconfig ! support-assist ! policy-map type application policy-iscsi ! class-map type application class-iscsi ! class-map type qos class-trust View compressed running - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 33
access vlan 1 no shutdown ! interface vlan 1 no shutdown ! interface mgmt1/1/1 ip address dhcp no shutdown ipv6 enable ipv6 address autoconfig ! support-assist ! policy-map type application policy-iscsi ! class-map type application class-iscsi ! class-map type qos class-trust Show difference between - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 34
file from server OS10# copy scp://admin:admin@hostip/backup-9-28.xml config://startup.xml OS10# reload Reload system image Reboot the system manually using the reload command in EXEC mode. You are prompted to confirm the operation. OS10# reload System configuration has been modified. Save? [yes - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 35
command The alias command allows you to create shortcuts for commonly used or long commands, and execute long commands along with the parameters. The alias supports the following modes: • Persistent mode - The alias is persistent and can be used in other sessions as well. The aliases created in the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 36
Create alias OS10# alias showint "show interface $*" OS10(config)# alias goint "interface ethernet $1" OS10(config)# commit View alias status OS10# showint status Port Description Status Speed Duplex Mode Vlan Tagged-Vlans Eth 1/1/1 up 40G A 1 - Eth 1/1/2 up 40G A 1 - Eth 1/1/3 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 37
---govlt goint shconfig showint shver ---Config Config Local Local Local Number of config aliases : 2 Number of local aliases : 3 View alias detail OS10# show alias detail Name Type ---- ---- govlt Config goint Config shconfig Local showint Local shver Local Number of config - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 38
@OS10:/opt/dell/os10/bin$ User admin logged out at session 16 SSH commands You can execute commands remotely using an SSH session. This is supported only for show commands. • Enter the show command along with SSH. $ ssh admin@ip-address show-command $ ssh [email protected] "show version - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 39
:38 OS9 environment commands You can configure commands in an OS9 environment by using the feature config-os9-style command. The current release supports VLAN tagging and port-channel grouping commands. • VLAN Interface mode • tagged • no tagged • untagged • no untagged • Port-channel Interface mode - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 40
1 - Eth 1/1/32 up 40G A 1 - OS10# configure terminal OS10(config)# alias goint "interface ethernet $1" OS10(config)# commit OS10(config)# goint 1/1/1 Supported Releases 10.3.0E or later batch Executes a series of commands in a file in batch (non-interactive) processing. Syntax batch - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 41
Feb 15 19:26:1: %Dell EMC (OS10) %Node.1-Unit.1:PRI:OS10 %lognotice:IP_ADDRESS_ADD: IP Address add is successful.:IP 172.17.4.1/24 added successful Supported Releases 10.2.0E or later boot Configures which OS10 image to use the next time the system boots up. Syntax boot system [active | standby - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 42
mode. Default Not configured Command Mode EXEC Usage Information Enter conf t for auto-completion. Example OS10# configure terminal OS10(config)# Supported Releases 10.2.0E or later copy Copies the current running configuration to the startup configuration and transfers files between an - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 43
2017-02-15T21:19:54Z 54525 config.xml ... Name Example (replace startup configuration) OS10# home://config.xml config://startup.xml Supported Releases 10.2.0E or later delete Removes or deletes the startup configuration file. Syntax delete [config://filepath | coredump://filepath | home - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 44
) OS10# dir config Directory contents for folder: config Date (modified) Size (bytes) Name 2017-04-26T15:23:46Z 26704 startup.xml Supported Releases 10.2.0E or later discard Discards any changes made to the candidate configuration file. Syntax discard Parameters None Default Not - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 45
the commands in OS9 format, commit to save the change. In the next session, you can configure the commands in OS9 format. The current release supports VLAN tagging and Port channel grouping commands. This feature does not have any impact on the show commands. Use the no form of the command - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 46
exit Parameters None Default Not configured Command Mode All Usage Information None Example OS10(conf-if-eth1/1/1)# exit OS10(config)# Supported Releases 10.2.0E or later license Installs a license file from a local or remote location. Syntax Parameters license install [ftp: | http - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 47
configuration to disable modification. Syntax lock Parameters None Default Not configured Command Mode EXEC Usage Information None Example OS10# lock Supported Releases 10.2.0E or later management route Configures an IPv4/IPv6 static route used by the Management port. Repeat the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 48
-backup.xml Example (dir) OS10# dir config Directory contents for folder: config Date (modified) Size (bytes) Name 2017-04-26T15:23:46Z 26704 startup.xml Supported Releases 10.2.0E or later no Disables or deletes commands in EXEC mode. Syntax no [alias | debug - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 49
this command, as it reloads the OS10 image and reboots the device. Example OS10# reload Proceed to reboot the system? [confirm yes/no]:y Supported Releases 10.2.0E or later show alias Displays configured alias commands available in both persistent and non-persistent modes. Syntax show alias - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 50
10.2.9999E Standby SW Build Version: 10.2.9999E(3633) Standby Build Date/Time: 2017-01-25T06:36:22Z Next-Boot: active[A] Supported Releases 10.2.0E or later show candidate-configuration Displays the current candidate configuration file. Syntax show candidate-configuration [aaa | access-list - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 51
password $6$q9QBeYjZ$jfxzVqGhkxX3smxJSH9DDz7/3OJc6m5wjF8nnLD7/ VKx8SloIhp4NoGZs0I/UNwh8WVuxwfd9q4pWIgNs5BKH. aaa authentication local snmp-server contact http://www.dell.com/support snmp-server location "United States" logging monitor disable ip route 0.0.0.0/0 10.11.58.1 ! Getting Started 51 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 52
32 switchport access vlan 1 no shutdown ! interface vlan 1 no shutdown ! interface mgmt1/1/1 ip address 10.11.58.145/8 no shutdown ipv6 enable ipv6 address autoconfig ! support-assist ! policy-map type application policy-iscsi ! class-map type application class-iscsi ! class-map type qos class-trust - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 53
A00 CN-0MGDH8-28298-52R-0394 AEIOU## 226 457 410 1 S6000-ON-FANTRAY-3 0MGDH8 A00 CN-0MGDH8-28298-52R-0392 AEIOU## 226 457 410 Supported Releases 10.2.0E or later show ip management-route Displays the IPv4 routes used to access the management port. Syntax Parameters show ip management-route - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 54
an IPv4 or IPv6 management route. OS10# show ip management-route Destination Gateway State Source 192.168.10.0/24 managementethernet Connected Connected Supported Releases 10.2.2E or later show ipv6 management-route Displays the IPv6 routes used to access the management port. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 55
command to verify the current license for running OS10, its duration, and the service tag of the switch to which it is assigned. OS10# show license status 94 day(s) left License location: /mnt/license/5XYK0Z1.lic Supported Releases 10.3.0E or later show running-configuration Displays the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 56
admin password $6$q9QBeYjZ$jfxzVqGhkxX3smxJSH9DDz7/3OJc6m5wjF8nnLD7/ VKx8SloIhp4NoGZs0I/UNwh8WVuxwfd9q4pWIgNs5BKH. aaa authentication local snmp-server contact http://www.dell.com/support snmp-server location "United States" logging monitor disable ip route 0.0.0.0/0 10.11.58.1 ! interface ethernet1 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 57
32 switchport access vlan 1 no shutdown ! interface vlan 1 no shutdown ! interface mgmt1/1/1 ip address 10.11.58.145/8 no shutdown ipv6 enable ipv6 address autoconfig ! support-assist ! policy-map type application policy-iscsi ! class-map type application class-iscsi ! class-map type qos class-trust - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 58
32 switchport access vlan 1 no shutdown ! interface vlan 1 no shutdown ! interface mgmt1/1/1 ip address 10.11.58.145/8 no shutdown ipv6 enable ipv6 address autoconfig ! support-assist ! policy-map type application policy-iscsi ! class-map type application class-iscsi ! class-map type qos class-trust - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 59
System Location LED Required Type Current Type Hardware Revision Software Version Bios Version Physical Ports : off : S6000 : S6000 : A02 : 10.2.9999E : 3.20.0.3 : 32x40GbE -- Power Supplies -- PSU-ID Status Type AirFlow Fan Speed(rpm) Status 1 up AC NORMAL 1 6568 up 2 fail -- Fan - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 60
(4265) Build Time: 2017-04-13T06:00:50.738-07:00 System Type: S6000-ON Architecture: x86_64 Up Time: 2 weeks 1 day 10:27:15 Supported Releases 10.2.0E or later system Executes a Linux command from within OS10. Syntax Parameters Default system command command - Enter the Linux command to execute - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 61
. Default Command Mode Usage Information Example 24 terminal lines EXEC Enter zero (0) for the terminal to display without pausing. OS10# terminal monitor Supported Releases 10.2.0E or later traceroute Displays the routes that packets take to travel to an IP address. Syntax traceroute host - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 62
traceroute (default 16). • -t tos - (Optional) For IPv4, enter the Type of Service (TOS) and Precedence values to use. 16 sets a low delay; 8 sets a packets 1 20::1 (20::1) 2.622 ms 2.649 ms 2.964 ms Supported Releases 10.2.0E or later unlock Unlocks a previously locked candidate configuration - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 63
Example OS10# unlock Supported Releases 10.2.0E or later write Copies the current running configuration to the startup configuration . Use the copy command to save running configuration changes to a local file. OS10# write memory Supported Releases 10.2.0E or later Getting Started 63 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 64
(Ethernet), port-channels, and VLANs in L2 or L3 modes. Table 1. Interface types Interface type Ethernet (PHY) Management Loopback Port-channel VLAN Supported / default mode L2, L3 / unset N/A L3 / L3 L2, L3 / unset L2, L3 / L3 Requires creation / default status No / no shutdown (enabled) No - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 65
from the access VLAN ID, it drops the packet. By default, a trunk interface carries only untagged traffic on the access VLAN - you must manually configure other VLANs for tagged traffic. 1 Select one of the two available options: • Configure L2 trunking in INTERFACE mode and the tagged VLAN traffic - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 66
interfaces and port-channels can be members of VLANs. You cannot simultaneously use egress rate shaping and ingress rate policing on the same VLAN. OS10 supports inter-VLAN routing - L3 routing in VLANs. You can add IP addresses to VLANs and use them in routing protocols in the same manner that - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 67
address is 120.120.120.120/24 Mode of IPv4 Address Assignment : MANUAL MTU 1532 bytes Flowcontrol rx false tx false ARP type: ARPA, ARP Timeout: a port-channel must contain interfaces of the same interface type and speed. OS10 supports up to 128 port-channels, with up to 16 10G or 40G ports per - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 68
settings - only the description and shutdown or no shutdowncommands are supported. You cannot add an IP address or a static MAC address static LAG A static port-channel (LAG) contains member interfaces that you manually assign using the channel-group command. OS10(config)# interface port-channel 10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 69
Minimum links Configure minimum links in a port-channel (LAG) that must be in oper up status to consider the port-channel to be in oper up status. 1 Enter the number of links in a LAG that must be in oper up status in PORT-CHANNEL mode (1 to 32, default 1). minimum-links number 2 Save the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 70
For packets without a L3 header, OS10 automatically uses the load-balancing mac-selection destination-mac command for hash algorithms by default. Do not configure IP hashing or MAC hashing at the same time. If you configure an IP and MAC hashing scheme at the same time, the MAC hashing scheme takes - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 71
to the protocol, the character is rejected and an underscore or blank is displayed in its place. • CL74-FC - Supports 25G and 50G • CL91-RS - Supports 100G • CL108-RS - Supports 100G • off - Disables FEC Configure FEC OS10(config)# interface ethernet 1/1/1 OS10(conf-if-eth1/1/1)# fec CL74-FC View - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 72
• ethernet node/slot/port[:subport] - Display Ethernet interface information. • loopback id - Display loopback interface information (0 to 16383). • mgmt node/slot/port - Display Management interface information. • port-channel id-number - Display port-channel interface information (1 to 128). • - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 73
.1 TenGigabitEthernet 1/7/1 unassigned TenGigabitEthernet 1/8/1 unassigned TenGigabitEthernet 1/9/1 unassigned OK? Method NO Manual NO Manual YES Manual YES Manual YES Manual YES Manual NO Manual NO Manual NO Manual Status administratively down administratively down up up up up administratively - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 74
configured for each interface. • The no version of this command deletes the description. Example OS10(conf-if-eth1/1/7)# description eth1/1/7 Supported Releases 10.2.0E or later duplex Configures duplex mode on the Management port. Syntax Parameters duplex {full | half | auto} • full - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 75
on 25G, 50G, and 100G interfaces. Syntax fec {CL74-FC | CL91-RS | CL108-RS | off} Parameters • CL74-FC - Supports 25G and 50G • CL91-RS - Supports 100G • CL108-RS - Supports 25G and 50G • off - Disables FEC Defaults • For 25G and 50G interfaces: off • For 100G interfaces: CL91-RS Command Mode - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 76
CONFIGURATION The no version of this command deletes the loopback interface. OS10(config)# interface loopback 100 OS10(conf-if-lo-100)# Supported Releases 10.2.0E or later interface mgmt Configures the Management port. Syntax interface mgmt node/slot/port Parameters node/slot/port - Enter - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 77
CONFIGURATION The no version of this command deletes the interface. OS10(config)# interface port-channel 10 OS10(conf-if-po-10)# Supported Releases 10.2.0E or later interface range Configures a range of Ethernet, port-channel, or VLAN interfaces for bulk configuration. Syntax interface - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 78
interface vlan vlan-id vlan-id - Enter the VLAN ID number (1 to 4094). VLAN 1 CONFIGURATION FTP, TFTP, MAC ACLs, and SNMP operations are not supported - IP ACLs are supported on VLANs only. The no version of this command deletes the interface. OS10(config)# interface vlan 10 OS10(conf-if-vl-10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 79
Usage Information Use the no version of this command to remove the configuration. Example OS10(config)# interface vlan 11 OS10(conf-if-vl-11)# mgmt Supported Releases 10.3.0E or later mtu Sets the link maximum transmission unit (MTU) frame size for an Ethernet L2 or L3 interface. Syntax mtu - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 80
show interface Displays interface information Syntax Parameters show interface [type] interface type - Enter the interface type: • phy-eth node/slot/port[:subport] - Display information about physical ports connected to the interface. • status - Display interface status. • ethernet node/slot/ - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 81
10 (Up) Eth 1/1/11 (Down) Eth 1/1/12 (Inact) 23 L2 up 20:34:32 Eth 1/1/20 (Up) Eth 1/1/21 (Up) Eth 1/1/22 (Up) Supported Releases 10.2.0E or later show link-bundle-utilization Displays information about the link-bundle utilization. Syntax show link-bundle-utilization Parameters None Default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 82
Type Protocol Member Ports 22 port-channel22 (U) Eth STATIC 1/1/10(P) 1/1/11(P) 1/1/14(P) 1/1/16(P) 1/1/19(P) 23 port-channel23 (D) Eth STATIC Supported Releases 10.2.0E or later show vlan Displays the current VLAN configuration. Syntax Parameters Default Command Mode Usage Information Example - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 83
OS10(conf-if-eth1/1/7)# no shutdown OS10(conf-if-eth1/1/7)# do commit Supported Releases 10.2.0E or later speed Configures an interface speed setting for the This command is found on the Management interface only. When manually configuring the management port speed, you must consider and match - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 84
/1/3)# switchport access vlan 100 OS10(conf-if-eth1/1/3)# do commit Supported Releases 10.2.0E or later switchport mode Places an interface in parameter configures an interface to transmit tagged VLAN traffic. You must manually configure VLAN membership for a trunk port with the switchport trunk - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 85
id-list - Enter the VLAN numbers of the tagged traffic that the L2 trunk port can carry. Commaseparated and hyphenated VLAN number ranges are supported. Default None Command Mode INTERFACE Usage Information Use the no version of this command to remove the configuration. Example OS10(conf-if-ma - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 86
3 Layer 2 802.1X Verifies device credentials prior to sending or receiving packets using the extensible authentication protocol (see 802.1X Commands). Link Aggregation Control Protocol (LACP) Exchanges information between two systems and automatically establishes a LAG between the systems (see - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 87
NOTE: OS10 supports only RADIUS as the back-end authentication server. The authentication process involves three devices: • Supplicant - The device attempting to access the network performs the role - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 88
802.1X with EAP-MD5, EAP-OTP, EAP-TLS, EAP-TTLS, PEAPv0, PEAPv1, and MS-CHAPv2 with PEAP and all platforms support RADIUS as the authentication server. If the primary RADIUS server becomes unresponsive, the authenticator begins using a secondary RADIUS server if configured. NOTE: 802.1X is - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 89
Enable 802.1X 1 Enable 802.1X globally in CONFIGURATION mode. dot1x system-auth-control 2 Enter an interface or a range of interfaces in INTERFACE mode. interface range 3 Enable 802.1X on the supplicant interface only in INTERFACE mode. dot1x port-control auto 4 Save the configuration. do commit - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 90
reasons why the supplicant might fail to respond - the supplicant may have been booting when the request arrived, there may be a physical layer problem, and so on. 1 Configure the amount of time that the authenticator waits before re-transmitting an EAP Request Identity frame in INTERFACE mode - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 91
Failure quiet period If the supplicant fails the authentication process, the authenticator sends another Request Identity frame after 30 seconds by default. The quiet period is a transmit interval time after a failed authentication. The Request Identity Re-transmit interval is for an unresponsive - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 92
force-authorized (default) force-unauthorized auto This is an authorized state. A device connected to this port does not use the authentication process but can communicate on the network. Placing the port in this state is same as disabling 802.1X on the port. forceauthorized is the default mode. - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 93
1 Re-authenticate the supplicant in INTERFACE mode (1 to 65535, default 3600). dot1x timeout re-authperiod seconds 2 Save the configuration. do commit Configure and verify reauthentication time period OS10(config)# interface range ethernet 1/1/7-1/1/8 OS10(conf-range-eth1/1/7-1/1/8)# dot1x re- - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 94
Configure and verify server timeouts OS10(conf-range-eth1/1/7-1/1/8)# dot1x timeout supp-timeout 45 OS10(conf-range-eth1/1/7-1/1/8)# dot1x timeout server-timeout 60 OS10(conf-range-eth1/1/7-1/1/8)# do commit OS10(conf-range-eth1/1/7-1/1/8)# do show dot1x interface ethernet 1/1/7 802.1x information - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 95
this command resets the value to the default. OS10(conf-range-eth1/1/7-1/1/8)# dot1x host-mode multi-auth OS10(conf-range-eth1/1/7-1/1/8)# do commit Supported Releases 10.2.0E or later dot1x max-req Changes the maximum number of requests that the device sends to a supplicant before restarting 802 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 96
resets the value to the default. OS10(conf-range-eth1/1/7-1/1/8)# dot1x timeout quiet-period 120 OS10(conf-range-eth1/1/7-1/1/8)# do commit Supported Releases 10.2.0E or later dot1x timeout re-authperiod Sets the number of seconds between re-authentication attempts. Syntax Parameters Default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 97
of this command resets the value to the default. OS10(conf-range-eth1/1/7-1/1/8)# dot1x timeout supp-timeout 45 OS10(conf-range-eth1/1/7-1/1/8)# do commit Supported Releases 10.2.0E or later dot1x timeout tx-period Sets the number of seconds that the device waits for a response to an EAP-request - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 98
Not configured EXEC None OS10# show dot1x PAE Capability: Protocol Version: System Auth Control: Auth Server: Authenticator only 2 Enable Radius Supported Releases 10.2.0E or later show dot1x interface Displays 802.1X configuration information. Syntax Parameters Command Mode Usage Information - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 99
for Supplicant: 01:80:c2:00:01:1c Port Auth Status: UNAUTHORIZED Untagged VLAN id: 1 Auth PAE State: Initialize Backend State: Idle Supported Releases 10.2.0E or later Link aggregation control protocol Group Ethernet interfaces to form a single link layer interface called a LAG or port - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 100
• If a physical interface is a part of a dynamic LAG, the channel-group id command is rejected on that interface. • You cannot add static and dynamic members to the same LAG. • There is a difference between the shutdown and no interface port-channel commands: • The shutdown command on LAG xyz - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 101
3 Set the channel group mode to Active in INTERFACE mode. channel-group number mode active 4 Save the configuration. do commit Configure dynamic LAG interfaces OS10(config)# interface port-channel 10 OS10(conf-if-po-10)# exit OS10(config)# interface ethernet 1/1/10 OS10(conf-if-eth1/1/10)# no - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 102
Sample configuration This sample topology is based on two routers - Alpha and Bravo. Alpha LAG configuration summary OS10(config)# interface port-channel 1 OS10(conf-if-po-1)# do commit OS10(conf-if-po-1)# exit OS10(config)# interface ethernet 1/1/49 OS10(conf-if-eth1/1/49)# no switchport OS10(conf - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 103
Port ethernet1/1/49 is Enabled, LACP is enabled and mode is lacp Actor Admin: State BCFHJKNO Key 1 Priority 32768 Oper: State BDEGIKNO Key 1 Priority 32768 Partner Admin: State BCEGIKNP Key 0 Priority 0 Oper: State BDEGIKNO Key 1 Priority 32768 Port ethernet1/1/50 is Enabled, LACP is enabled and - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 104
Queuing strategy :fifo Input statistics: 1388 packets, 135026 octets 666 64-byte pkts,1 over 64-byte pkts, 721 over 127-byte pkts 0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts 1388 Multicasts, 0 Broadcasts 0 runts, 0 giants, 0 throttles 0 CRC, 0 overrun, 1387 discarded Output - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 105
- Enter the port-channel group number (1 to 128). The maximum number of port-channels is 128. The maximum physical port/maximum NPU is supported. • mode - Enter the interface port-channel mode. • active - Enter to enable the LACP interface. The interface is in the Active Negotiating state when - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 106
the maximum bundle size to the default value. Example OS10(conf-if-po-10)# lacp max-bundle 10 OS10(conf-if-po-10)# do commit Supported Releases 10.2.0E or later lacp port-priority Sets the priority for the physical interfaces for LACP. Syntax lacp port-priority priority Parameters priority - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 107
of this command resets the rate to the default value. OS10(conf-range-eth1/1/7-1/1/8)# lacp rate fast OS10(conf-range-eth1/1/7-1/1/8)# do commit Supported Releases 10.2.0E or later lacp system-priority Sets the system priority of the device for LACP. Parameters priority - Enter the priority - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 108
0 Ethernet1/10 513 501 0 0 0 0 0 Ethernet1/11 497 485 0 0 0 0 0 Ethernet1/12 493 486 0 0 0 0 0 Ethernet1/13 492 485 0 0 0 0 0 --more-- Supported Releases 10.2.0E or later show lacp interface Displays information about specific LACP interfaces. Syntax Parameters Default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 109
=passive LACP_Timeout=Long Timeout(30s) Synchronization=IN_SYNC Collecting=true Distributing=true Partner Admin State=BCEGIKNP Partner Oper State=BDEGIKMO Supported Releases 10.2.0E or later show lacp neighbor Displays information about LACP neighbors. Syntax show lacp neighbor [interface port - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 110
1 Priority 32768 Oper: State BDEGIKNO Key 1 Priority 32768 Partner Admin: State BCEGIKNP Key 0 Priority 0 Oper: State BDEGIKMO Key 1 Priority 32768 Supported Releases 10.2.0E or later show lacp system-identifier Displays the LACP system identifier for a device. Syntax Parameters Default Command - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 111
LAN device to advertise its configuration and receive configuration information from adjacent LLDP-enabled LAN devices. • LLDP is enabled by default. • LLDP supports a maximum of 250 total neighbors per system. If the number of interfaces multiplied by eight exceeds the maximum, the system does not - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 112
configuration information. These sub-types are Management TLVs, IEEE 802.1, IEEE 802.3, and TIA-1057 Organizationally-Specific TLVs. Optional TLVs OS10 supports basic TLVs, IEEE 802.1, and 802.3 organizationally-specific TLVs, and TIA-1057 organizationally-specific TLVs. A basic TLV is an optional - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 113
settings are due to auto-negotiation or due to manual configuration. 127 - Power via MDI Not supported. 127 - Link aggregation Indicates whether the link the IEEE 802 LAN network edge and participate in IP communication service using the LLDPMED framework, such as IP phones and conference - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 114
address LCI • Emergency call services ELIN 127/4 - Extended Power requirements, priority, and power status. power-via-MDI LLDP-MED capabilities TLV The LLDP-MED capabilities TLV communicates the types of TLVs that the endpoint device and the network connectivity device support. The value of the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 115
In this case, configure the signaling application. 0 - Reserved - 1 - Voice Used for dedicated IP telephony handsets and other appliances supporting interactive voice services. 2 - Voice signaling Used only if voice control packets use a separate network policy than voice data. 3 - Guest voice - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 116
Define network policies You can ,anually define LLDP-MED network policies. LLDP commands that you configure at CONFIGURATION level are global and affect all interfaces. LLDP commands you configure at INTERFACE level affect only the specific interface. Create up to 32 network policies and attach the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 117
Disable and re-enable LLDP By default, LLDP is enabled. You can disable LLDP on an interface. 1 Disable the LLDPDU transmit or receive in INTERFACE mode. no lldp transmit no lldp receive 2 Disable the LLDP holdtime multiplier value in CONFIGURATION mode. no lldp holdtime-multiplier 3 Disable the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 118
Configure advertise TLVs OS10(conf-if-eth1/1/3)# lldp tlv-select basic-tlv system-name OS10(conf-if-eth1/1/1)# lldp tlv-select dot3tlv macphy-config max-framesize OS10(conf-if-eth1/1/3)# lldp tlv-select dot1tlv link-aggregation OS10(conf-if-eth1/1/3)# do commit Network policy advertisement LLDP-MED - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 119
Rapid availability is crucial for applications such as emergency call service location (E911). 1 Enable fast start repeat count which is the number of packets sent during activation in CONFIGURATION mode (1 to 10, default 3). lldp-med fast- - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 120
Router Enabled System Capabilities: Repeater, Bridge, Router Remote Max Frame Size: 0 Remote Aggregation Status: false MAC PHY Configuration: Auto-neg supported: 1 Auto-neg enabled: 1 Auto-neg advertised capabilities: 10BASE-T half duplex mode, 10BASE-T full duplex mode, 100BASE-TX half duplex mode - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 121
Extended Power via MDI - PD, Inventory Management Current: LLDP-MED Capabilities, Network Policy, Location Identification, Extended Power via MDI - PD, Inventory Management Device Class: Endpoint Class 3 Network Policy: Application: voice, Tag: Tagged, Vlan: 50, L2 Priority: 6, DSCP Value: - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 122
lldp counters None Not configured EXEC The counter default value resets to zero for all physical interfaces. OS10# clear lldp counters Supported Releases 10.2.0E or later clear lldp table Clears LLDP neighbor information for all interfaces. Syntax clear lldp table Parameters None Default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 123
lldp med disable command to disable LLDP-MED on a specific interface. OS10(conf-if-eth1/1/1)# lldp med disable Supported Releases 10.2.0E or later lldp med network-policy Manually defines an LLDP-MED network policy. Syntax Parameters lldp-med network-policy number app {voice | voice-signaling - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 124
and attach the LLDP-MED network policies to a port. OS10(config)# lldp med network-policy 10 app voice vlan 10 vlan-type tag priority 2 dscp 1 Supported Releases 10.2.0E or later lldp med network-policy (Interface) Attaches or removes an LLDP-MED network policy to or from an interface. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 125
value in seconds (1 to 10). 2 seconds CONFIGURATION The no version of this command resets the value to the default. OS10(config)# lldp reinit 5 Supported Releases 10.2.0E or later lldp timer Configures the rate (in seconds) at which LLDP packets send to the peers. Syntax Parameters Default lldp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 126
Information Example CONFIGURATION The no version of this command sets the LLDP timer back to its default value. OS10(config)# lldp timer 25 Supported Releases 10.2.0E or later lldp tlv-select basic-tlv Enables or disables TLV attributes to transmit and receive LLDP packets. Syntax Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 127
The no version of this command disables the transmission of LLDP packets on a specific interface. OS10(conf-if-eth1/1/9)# lldp transmit Supported Releases 10.2.0E or later show lldp interface Displays the LLDP information advertised from a specific interface. Syntax show lldp interface ethernet - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 128
errors None Not configured EXEC None OS10# show lldp errors Total Memory Allocation Failures: 0 Total Input Queue Overflows: 0 Total Table Overflows: 0 Supported Release 10.2.0E or later show lldp med Displays the LLDP MED information for all the interfaces. Syntax show lldp med Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 129
No ethernet1/1/30 | Yes| Yes| No| No| No ethernet1/1/31 | Yes| Yes| No| No| No ethernet1/1/32 | Yes| Yes| No| No| No Supported Releases 10.2.0E or later show lldp neighbors Displays the status of the LLDP neighbor system information. Syntax Parameters show lldp neighbors [detail - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 130
Enabled System Capabilities: Repeater, Bridge, Router Remote Max Frame Size: 0 Remote Aggregation Status: false MAC PHY Configuration: Auto-neg supported: 1 Auto-neg enabled: 1 Auto-neg advertised capabilities: 10BASE-T half duplex mode, 10BASE-T full duplex mode, 100BASE-TX half duplex - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 131
configured EXEC None OS10# show lldp timers LLDP Timers: Holdtime in seconds: 120 Reinit-time in seconds: 6 Transmit interval in seconds: 30 Supported Releases 10.2.0E or later show lldp tlv-select interface Displays the TLVs enabled for an interface. Syntax Parameters Default Command Mode Usage - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 132
0 Total Med TLVS Discarded : 0 Total Med Capability TLVS Discarded: 0 Total Med Policy TLVS Discarded : 0 Total Med Inventory TLVS Discarded : 0 Supported Releases 10.2.0E or later show nework-policy profile Displays the network policy profiles. Syntax Parameters Default Command Mode Usage - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 133
Supported Releases 10.2.0E or later Media Access Control All Ethernet switching ports table aging-time 0 OS10(config)# do commit Static MAC Address A static MAC address entry is one that you manually configure. A static entry is not subject to aging. 1 Create a static MAC address entry in the MAC - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 134
• interface port-channel number - (Optional) Displays port channel information (1 to 128). • count - (Optional) Displays the number of dynamic and static MAC address entries. • vlan vlan-id - (Optional) Displays information for a specified VLAN only (1 to 4094). View MAC Address Table Entries OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 135
all dynamic entries from the address table. OS10# clear mac address-table dynamic all Example (VLAN) OS10# clear mac address-table dynamic vlan 20 Supported Releases 10.2.0E or later mac address-table aging-time Configures the aging time for entries in the L2 address table. Syntax Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 136
Example (PortChannel) OS10(config)# mac address-table static 34:17:eb:02:8c:33 vlan 10 interface port-channel 1 OS10(config)# do commit Supported Releases 10.2.0E or later show mac address-table Displays information about the MAC address table. Syntax show mac address-table [address mac - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 137
protocol is compatible with RSTP and RPVST+. When you enable MST, all ports in Layer 2 mode participate in MST. Keep in mind that OS10 only supports one MST region. Load balancing can be achieved using the MST protocol. When three VLANs are mapped to two MSTIs, VLAN 100 traffic takes a different - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 138
Configure and verify MSTP OS10(config)# spanning-tree mode mst OS10(config)# do commit OS10(config)# do show spanning-tree show spanning-tree mst configuration Region Name: ravi Revision: 0 MSTI VID 0 1,7-4093 1 2 2 3 3 4 4 5 5 6 Add or remove interfaces By default, all - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 139
View port forwarding/discarding state OS10# show spanning-tree msti 0 brief Spanning tree enabled protocol msti with force-version mst MSTI 0 VLANs mapped 1,31-4093 Executing IEEE compatible Spanning Tree Protocol Root ID Priority 32768, Address 3417.4455.667f Root Bridge hello time 2, max age - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 140
Link-type Edge ethernet1/1/5 Root 128.276 128 500 FWD 0 AUTO No ethernet1/1/6 Altr 128.280 128 500 BLK 0 AUTO No Non-Dell hardware OS10 supports only one MST region. For a bridge to be in the same MST region as another, the three unique attributes (name, revision, and VLAN-to-instance - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 141
Revision: 0 MSTI VID 1 100 2 200-300 Modify parameters The root bridge sets the values for forward-delay, hello-time, max-age, and max-hops and overwrites the values set on other MST bridges. Forward-time Hello-time Max-age Max-hops Time an interface waits in the Discarding state and Learning - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 142
ethernet1/1/5 Root 128.276 128 500 FWD 0 AUTO No ethernet1/1/6 Altr 128.280 128 500 BLK 0 AUTO No Interface parameters Adjust two interface parameters to increase or decrease the likelihood that a port becomes a forwarding port. Port cost Port priority Value that is based on the interface - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 143
the active network topology. OS10 supports BPDU filtering, BPDU guard, root BPDUs from an erroneous device. Enabling BPDU Filtering instructs the hardware to drop BPDUs and prevents flooding only resume operation from Shutdown state after manual intervention. Avoids bridging loops and preserves - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 144
To clear Error Disabled state: • Use the shutdown command on the interface. • Use the spanning-tree bpdufilter disable command to disable the BPDU guard on the interface. • Use the spanning-tree disable command to disable STP on the interface. 2 Enable STP BPDU guard in INTERFACE mode. spanning-tree - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 145
OS10(conf-if-eth1/1/4)# do commit OS10(conf-if-eth1/1/4)# do show spanning-tree interface ethernet 1/1/4 ethernet1/1/4 of vlan1 is root Forwarding Edge port:no (default) port guard :none (default) Link type is point-to-point (auto) Boundary: NO bpdu filter : bpdu guard : bpduguard shutdown-on- - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 146
). 15 seconds CONFIGURATION The no version of this command resets the value to the default. OS10(config)# spanning-tree mst forward-time 16 Supported Releases 10.2.0E or later spanning-tree mst hello-time Sets the time interval between generation and transmission of MSTP BPDUs. Syntax spanning - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 147
the default. Example OS10(config)# spanning-tree mst max-age 10 Supported Releases 10.2.0E or later spanning-tree mst max-hops Configures the MST region. Example OS10(config)# spanning-tree mst max-hops 30 Supported Releases 10.2.0E or later instance Configures MST instances and one - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 148
instance related configuration. OS10(conf-mst)# instance 1 vlan 2-10 OS10(conf-mst)# instance 2 vlan 11-20 OS10(conf-mst)# instance 3 vlan 21-30 Supported Releases 10.2.0E or later name Assigns a name to the MST region. Syntax name region-name Parameters region-name - Enter a name for an MST - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 149
are non-Dell devices, ensure the revision number value matches on all the devices (see Non-Dell Hardware). OS10(conf-mst)# revision 10 Supported Releases 10.2.0E or later show spanning-tree mst Displays MST configuration information. Syntax show spanning-tree mst configuration Parameters None - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 150
Usage Information Example (Brief) View the MST instance information for a specific MST instance number in detail or brief, or view physical (Ethernet) port or port-channel information. OS10# show spanning-tree msti 0 brief Spanning tree enabled protocol msti with force-version mst MSTI 0 VLANs - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 151
If the port receives a BPDU, it is placed in the Error-Disabled state as a protective measure. OS10(conf-if-eth1/1/4)# spanning-tree bpduguard enable Supported Releases 10.2.0E or later spanning-tree guard Enables or disables loop guard or root guard on an interface. Syntax spanning-tree guard - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 152
mode. You can also change to RSTP/MST mode. OS10(config)# spanning-tree mode rstp Example (MST) OS10(config)# spanning-tree mode mst Supported Releases 10.2.0E or later spanning-tree mst Configures an MST instance and determines root and bridge priorities. Syntax spanning-tree mst instance - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 153
RSTP. Default Command Mode Usage Information Example Not configured CONFIGURATION Forces a bridge that supports MST to operate in a STP-compatible mode. OS10(config)# spanning-tree mst force-version Supported Releases 10.2.0E or later spanning-tree msti Configures the MSTI, cost, and priority - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 154
, the port immediately transitions to Forwarding state. Only configured ports connected to end hosts act as EdgePorts. OS10(config)# spanning-tree port type edge Supported Releases 10.2.0E or later Rapid per-VLAN spanning-tree plus RPVST+ is an RSTP to create a single topology per VLAN. RPVST+ is - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 155
By default, each VLAN instance is assigned default bridge priority 32768. For example, all three instances have the same forwarding topology. Traffic load balancing is not achievable with this kind of priority assignment. You must assign each instance a different priority to achieve load balancing, - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 156
ethernet1/1/5 128.276 128 500 FWD 0 32768 3417.4455.667f 128.146 ethernet1/1/6 128.280 128 500 BLK 0 32768 3417.4455.667f 128.150 Interface Name Role PortID Prio Cost Sts Cost Link-type Edge ethernet1/1/5 Root 128.276 128 500 FWD 0 AUTO No ethernet1/1/6 Altr 128.280 128 500 BLK 0 AUTO - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 157
ethernet1/1/1 128.260 128 200000000 FWD 0 32769 0000.0000.0000 ethernet1/1/2 128.264 128 200000000 FWD 0 32769 0000.0000.0000 ethernet1/1/3 128.268 128 200000000 FWD 0 32769 0000.0000.0000 ethernet1/1/4 128.272 128 200000000 FWD 0 32769 0000.0000.0000 ethernet1/1/5 128.276 128 500 FWD 0 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 158
loop guard on a port or port-channel interface in INTERFACE mode. no spanning-tree guard loop Port enabled with loop guard conditions • Loop guard is supported on any STP-enabled port or port-channel interface in RPVST+ mode. • You cannot enable root guard and loop guard at the same time on - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 159
Not configured EXEC Clear all STP counters on the device per Ethernet interface or port-channel. OS10# clear spanning-tree counters interface port-channel 10 Supported Releases 10.2.0E or later Layer 2 159 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 160
direction. • events - Debugs PVST events. Default Command Mode Usage Information Example Not configured EXEC None OS10# debug spanning-tree bpdu rx Supported Releases 10.2.0E or later show spanning-tree vlan Displays RPVST+ status and configuration information by VLAN ID. Syntax show spanning - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 161
128 200000000 FWD 0 32769 0000.0000.0000 128.300 ethernet1/1/12 128.304 128 200000000 FWD 0 32769 0000.0000.0000 128.304 Supported Releases 10.2.0E or later spanning-tree bpdufilter Enables or disables BPDU filtering on an interface. Syntax Parameters spanning-tree bpdufilter {enable | disable - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 162
If the port receives a BPDU, it is placed in the Error-Disabled state as a protective measure. OS10(conf-if-eth1/1/4)# spanning-tree bpduguard enable Supported Releases 10.2.0E or later spanning-tree guard Enables or disables loop guard or root guard on an interface. Syntax spanning-tree guard - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 163
The media speed of a LAN interface determines the STP port path cost default value. OS10(conf-if-eth1/1/4)# spanning-tree vlan 10 cost 1000 Supported Releases 10.2.0E or later spanning-tree vlan forward-time Configures a time interval for the interface to wait in Blocking state or Learning state - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 164
(4 to 30). Default Command Mode Usage Information Example 15 seconds CONFIGURATION None OS10(config)# spanning-tree vlan 10 forward-time 16 Supported Releases 10.2.0E or later spanning-tree vlan force-version Configures a forced version of spanning-tree to transmit BPDUs. Syntax Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 165
max-age seconds - Enter a maximum age value in seconds (6 to 40). 20 seconds CONFIGURATION None OS10(config)# spanning-tree vlan 10 max-age 10 Supported Releases 10.2.0E or later spanning-tree vlan priority Sets the priority value for RPVST+. Syntax spanning-tree vlan vlan-id priority priority - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 166
or secondary root bridge. Default Command Mode Usage Information Example Not configured CONFIGURATION None OS10(config)# spanning-tree vlan 1 root primary Supported Releases 10.2.0E or later Rapid spanning-tree protocol RSTP is similar to STP but provides faster convergence and interoperability - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 167
View all port participating in RSTP OS10# show spanning-tree Spanning tree enabled protocol rstp with force-version rstp Executing IEEE compatible Spanning Tree Protocol Root ID Priority 32768, Address 3417.4455.667f Root Bridge hello time 2, max age 20, forward delay 15 Bridge ID Priority - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 168
ethernet1/1/28 128.368 128 200000000 BLK 0 0 0000.0000.0000 0.0 ethernet1/1/29 128.372 128 200000000 BLK 0 0 0000.0000.0000 0.0 ethernet1/1/30 128.376 128 200000000 BLK 0 0 0000.0000.0000 0.0 ethernet1/1/31 128.380 128 200000000 BLK 0 0 0000.0000.0000 0.0 ethernet1/1/32 128.384 128 200000000 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 169
Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ethernet3/1/1 244.128 128 500 BLK 0 32768 90b1.1cf4.9b8a 128.244 ethernet3/1/2 248.128 128 500 BLK 0 32768 90b1.1cf4.9b8a 128.248 ethernet3/1/3 252.128 128 500 FWD 0 32768 90b1.1cf4.9b8a 128.252 ethernet3/1/4 256.128 128 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 170
1 Assign a number as the bridge priority or designate it as the primary or secondary root in CONFIGURATION mode. Configure the priority value range (0 to 65535 in multiples of 4096, default 32768). The lower the number assigned, the more likely this bridge becomes the root bridge. spanning-tree rstp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 171
supports BPDU filtering, BPDU guard, loop guard, and root guard STP extensions. BPDU filtering BPDU guard Root guard Loop guard Protects the network from unexpected flooding of BPDUs from an erroneous device. Enabling BPDU Filtering instructs Shutdown state after manual intervention. Avoids - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 172
Boundary: NO bpdu filter : Enable bpdu guard : bpduguard shutdown-on- violation :disable RootGuard: enable LoopGuard disable Bpdus (MRecords) sent 134, received 138 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ethernet1/1/4 128.272 128 500 BLK 500 32769 90b1.1cf4. - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 173
all STP counters on the device per Ethernet interface or port-channel. OS10# clear spanning-tree counters interface port-channel 10 Supported Releases 10.2.0E or later show spanning-tree active Displays the RSTP configuration and information for RSTP-active interfaces. Syntax Parameters Default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 174
to forwarding state 1 Link type is point-to-point by default, auto PVST Simulation is enabled by default BPDU sent 3, received 7 Supported Releases 10.2.0E or later spanning-tree bpdufilter Enables or disables BPDU filtering on an interface. Syntax spanning-tree bpdufilter {enable | disable - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 175
If the port receives a BPDU, it is placed in the Error-Disabled state as a protective measure. OS10(conf-if-eth1/1/4)# spanning-tree bpduguard enable Supported Releases 10.2.0E or later spanning-tree guard Enables or disables loop guard or root guard on an interface. Syntax spanning-tree guard - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 176
new mode. You can also change to RSTP/MST mode. OS10(config)# spanning-tree mode rstp Example (MST) OS10(config)# spanning-tree mode mst Supported Releases 10.2.0E or later spanning-tree port Sets the port type as the EdgePort. Syntax spanning-tree port type edge Parameters None Default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 177
-age seconds seconds - Enter a maximum age value in seconds (6 to 40). 20 seconds CONFIGURATION None OS10(config)# spanning-tree rstp max-age 10 Supported Releases 10.2.0E or later spanning-tree rstp Sets the priority value for RSTP. Syntax spanning-tree rspt priority priority value Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 178
the root bridge. A lower priority value increases the probability of the bridge becoming a root bridge. OS10(config)# spanning-tree rstp priority 200 Supported Releases 10.2.0E or later Virtual LANs VLAN segments a single flat L2 broadcast domain into multiple logical L2 networks. Each VLAN is - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 179
Create or remove VLANs You can create VLANs and add physical interfaces or port-channel (LAG) interfaces to the VLAN as tagged or untagged members. You can add an Ethernet interface as a trunk port or as an access port, but it cannot be added as both at the same time. Multiple non-default vlans - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 180
Interface index is 69208865 Internet address is not set MTU 1532 bytes LineSpeed auto Flowcontrol rx off tx off ARP type: ARPA, ARP Timeout: 240 Last clearing of "show interface" counters Queueing strategy: fifo Time since last interface status change: Vlan 200 is up, line protocol is up Address is - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 181
interface ethernet1/1/5 ... switchport access vlan 604 no shutdown ! interface vlan1 no shutdown ... Trunk mode A trunk port can be a member of multiple VLANs set up on an interface. A trunk port can transmit traffic for all VLANs. To transmit traffic on a trunk port with multiple VLANs, OS10 uses - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 182
2 Assign an IP address and mask to the VLAN in INTERFACE-VLAN mode. ip address ip-address/prefix-length [secondary] • ip-address/prefix-length - Enter the IP address in dotted-decimal format (A.B.C.D/x). • secondary - Enter the interface backup IP address (up to eight secondary IP addresses). 3 Save - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 183
View VLAN configuration OS10# show vlan Codes: * - Default VLAN, G-GVRP VLANs, R-Remote Port Mirroring VLANs, P-Primary, C-Community, I- Isolated Q: A-Access (Untagged), T-Tagged x-Dot1x untagged, X-Dot1x tagged G-GVRP tagged, M-Vlan-stack, H-VSN tagged i-Internal untagged, I-Internal tagged, - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 184
VLAN ID number (1 to 4094). Default VLAN 1 Command Mode CONFIGURATION Usage Information FTP, TFTP, MAC ACLs, and SNMP operations are not supported - IP ACLs are supported on VLANs only. The no version of this command deletes the interface. Example OS10(config)# interface vlan 10 OS10(conf-if - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 185
port monitoring (RPM) allows monitoring of traffic running across a remote device in the same LAN (see Remote port mirroring). • Port monitoring is supported on both physical and logical interfaces such as VLANs and port-channels. • For local port mirroring, the monitored source (MD) and monitoring - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 186
In the State field, true indicates that the port is enabled. In the Reason field, Is UP indicates that hardware resources are allocated. OS10# show monitor session all S.Id Source Destination Dir SrcIP DstIP DSCP TTL State Reason 1 ethernet1/1/7 port-channel10 rx N/A N/A N/A N/A true Is UP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 187
ACL mode. The ACL rules describe the traffic you want to monitor. Flow monitoring is supported for IPv4 ACLs, IPv6 ACLs, and MAC ACLs. seq sequence-number {deny | permit helps network administrators monitor and analyze traffic to troubleshoot network problems in a time-saving and efficient way. In - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 188
restriction on the VLAN IDs used for the reserved remote-mirroring VLAN. Valid VLAN IDs are from 2 to 4094. The default VLAN ID is not supported. • In mirrored traffic, packets that have the same destination MAC address as an intermediate or destination device in the path used by the reserved VLAN - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 189
functions as the destination port. • The reserved VLAN used to transport mirrored traffic must be a L2 VLAN - L3 VLANs are not supported. Configure remote port mirroring Remote port mirroring requires a source session (monitored ports on different source network devices), a reserved tagged VLAN - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 190
-SESSION The no version of this command resets the value to the default. OS10(conf-mon-local-10)# destination interface port-channel 10 Supported Releases 10.2.0E or later flow-based Enables flow-based monitoring. Syntax Parameters Default flow-based enable enable - Enable flow-based monitoring - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 191
session 10 OS10(conf-mon-local-10)# Example (RSPAN) OS10(config)# monitor session 20 type rspan-source OS10(conf-mon-rspan-20)# Supported Releases 10.2.0E or later show monitor session Displays information about a monitoring session. Syntax show monitor session {session-id | all} Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 192
-SESSION The no version of this command resets the value to disabled. OS10(config)# monitor session 10 OS10(conf-mon-local-10)# shut Supported Releases 10.2.0E or later source (Port Monitoring) Configures a source for port monitoring. Syntax Parameters source interface interface {both | rx | tx - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 193
same autonomous system First (OSPF) area using link-state advertisements (LSAs). OS10 supports up to 10,000 OSPF routes for OSPFv2 to designate up to 8,000 one network to another. An ISP uses a transit AS to sell transit service to a customer network. When BGP operates inside an AS - AS1 or AS2 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 194
AS. EBGP routers exchange information with other EBGP routers and IBGP routers to maintain connectivity and accessibility. Classless interdomain routing BGPv4 supports classless interdomain routing (CIDR) with aggregate routes and AS paths. CIDR defines a network using a prefix consisting of an IP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 195
, and notification messages to and from its peer. Peer templates Peer templates allow BGP neighbors to inherit the same outbound policies. Instead of manually configuring each neighbor with the same policy, you can create a peer group with a shared policy that applies to individual peers. A peer - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 196
per peer basis. The default is the IPv4 unicast routes. BGP session supports multiple address family interface (AFI) and sub address family interface (SAFI) is exchanged over the IPv4 peers and vice versa. BGP routers that support IPv6 can set up BGP sessions using IPv6 peers. If the existing BGP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 197
• A path with no AS_PATH configured has a path length of 0 • AS_CONFED_SET is not included in the AS_PATH length • AS_CONFED_SEQUENCE has a path length of 1 no matter how many ASs are in the AS_CONFED_SEQUENCE 4 Prefer the path with the lowest ORIGIN type-IGP is lower than EGP and EGP is lower than - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 198
Multiexit discriminators If two autonomous systems connect in more than one place, use a multiexit discriminator (MED) to assign a preference to a preferred path. MED is one of the criteria used to determine best path-other criteria may also impact selection. One AS assigns the MED a value. Other - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 199
The question mark (?) indicates an origin code of INCOMPLETE, and the lower case letter (i) indicates an origin code of IGP. Origin configuration OS10# show ip bgp BGP local RIB : Routes to be Added , Replaced , Withdrawn BGP local router ID is 30.1.1.1 Status codes: s suppressed, S stale, d - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 200
the bestpath as-path multipath-relax command at the same time, an error message displays-only enable one command at a time. More path support More path (Add-Path) reduces convergence times by advertising multiple paths to its peers for the same address prefix without replacing existing paths with - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 201
4-byte AS number configurations by default. The 4-byte support is advertised as a new BGP capability - 4-BYTE-AS, in the OPEN message. A BGP speaker that advertises 4-Byte-AS capability to a peer, and receives the same - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 202
• reuse = 750 • suppress = 2000 Timers • keepalive = 60 seconds • holdtime = 180 seconds Add-path Disabled Enable BGP BGP is disabled by default. The system supports one AS number - you must assign an AS number to your device. To establish BGP sessions and route traffic, configure at least one - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 203
BGP mode from CONFIGURATION mode (1 to 65535 for 2-byte, 1 to 4294967295 for 4byte). Only one AS number is supported per system. If you enter a 4-byte AS number, 4-byte AS support is enabled automatically. router bgp as-number 2 Enter a neighbor in ROUTER-BGP mode. neighbor ip-address 3 Add a remote - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 204
-source Loopback loopback0 no shutdown ! neighbor 192.168.12.2 remote-as 65123 update-source Loopback loopback0 no shutdown ! Configure Dual Stack OS10 supports dual stack for BGPv4 and BGPv6. Dual stack BGP allows simultaneous exchange of same IPv4 or IPv6 prefixes through different IPv4 and IPv6 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 205
. Create a peer template before configuring any route policies for the template. NOTE: An outbound filter policy, distribute list or route map, is not supported on a peer group member. NOTE: When creating a template command, you must include the remote-as command. 1 Enable BGP, and assign the AS - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 206
between advertisement runs is 30 seconds For address family: Unicast BGP neighbor is ebgppg, peer-group external Update packing has 4_OCTET_AS support enabled Number of peers in this group 1 Peer-group members: View running configuration OS10(config-router-neighbor)# do show running-configuration - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 207
Verify neighbor fall-over on neighbor OS10(config-router-neighbor)# do show ip bgp neighbors 3.1.1.1 BGP neighbor is 3.1.1.1, remote AS 100, local AS 100 internal link BGP version 4, remote router ID 3.3.3.33 BGP state ESTABLISHED, in this state for 00:17:17 Last read 00:27:54 seconds Hold time is - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 208
remote-as 102 ! Fast external fallover Fast external fallover terminates EBGP sessions of any directly adjacent peer if the link used to reach the peer goes down. BGP does not wait for the hold-down timer to expire. Fast external fallover is enabled by default. To disable or re-enable it, use the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 209
, see Peer templates. If you do not configure a BGP device in Peer-Listening mode, a session with a dynamic peer comes up. Passwords are not supported on BGPv4/v6 dynamic peers. Configure passive peering OS10(config)# router bgp 10 OS10(conf-router-bgp-10)# template bgppg OS10(conf-router-template - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 210
you can maintain existing AS numbers. Reconfigure your routers with the new information to disable after the migration. Network migration is not supported on passive peer templates. You must configure Peer templates before assigning it to an AS. 1 Enter a neighbor IP address, A.B.C.D, in ROUTER-BGP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 211
OS10(conf-router-neighbor)# address-family ipv4 unicast OS10(conf-router-bgp-neighbor-af)# allowas-in 5 View AS numbers in AS paths OS10# show running-configuration bgp ! router bgp 101 no fast-external-fallover ! address-family ipv4 unicast dampening ! neighbor 17.1.1.2 remote-as 102 no shutdown ! - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 212
Disable redistributed routes OS10(conf-router-bgp-af)# no redistribute ospf route-map ospf-to-bgp Enable redistributed routes OS10(conf-router-bgp-af)# redistribute ospf Additional paths The add-path command is disabled by default. 1 Assign an AS number in CONFIGURATION mode. router bgp as-number 2 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 213
Modify MED attributes OS10(config)# router bgp 100 OS10(conf-router-bgp-100)# always-compare-med OS10(conf-router-bgp-100)# bestpath med confed OS10(conf-router-bgp-100)# do commit Local preference attribute You can change the value of the LOCAL_PREFERENCE attributes for all routes the router - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 214
View route-map OS10(conf-route-map)# do show route-map route-map bgproutemap, permit, sequence 1 Match clauses: Set clauses: local-preference 500 metric 400 origin incomplete Weight attribute Influence the BGP routing based on the weight value. Routes with a higher weight value have preference when - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 215
Route-map filters Filtering routes allows you to implement BGP policies. Use route-maps to control which routes the BGP neighbor or peer group accepts and advertises. 1 Enter the neighbor IP address to filter routes in ROUTER-BGP mode. neighbor ipv4-address 2 Enter Address Family mode in ROUTER- - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 216
6 Save the configuration. do commit When you enable a route reflector, the system automatically enables route reflection to all clients. To disable route reflection between all clients in this reflector, use the no bgp client-to-client reflection command in ROUTER-BGP mode. You must fully mesh all - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 217
byte, 1 to 4294967295 for 4-byte. All Confederation routers must be either 4 bytes or 2 bytes. You cannot have a mix of router ASN support. confederation peers as-number [... as-number] Configure BGP confederations OS10(config)# router bgp 65501 OS10(conf-router-bgp-65501)# confederation identifier - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 218
The constant router reaction to the WITHDRAWN and UPDATE notices causes instability in the BGP process. To minimize this instability, configure penalties (a numeric value) for routes that flap. When that penalty value reaches a configured limit, the route is not advertised, even if the route is up, - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 219
request to the neighbor and receives all the peer's updates. To use soft reconfiguration, or soft reset without preconfiguration, both BGP peers must support the soft route refresh capability. The soft route refresh advertises in the OPEN message sent when the peers establish a TCP session. To - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 220
neighbor, use the no activate command. Example OS10(conf-router-neighbor)# address-family ipv4 unicast OS10(conf-router-bgp-neighbor-af)# activate Supported Releases 10.2.0E or later add-path Allows the system to advertise multiple paths for the same destination without replacing previous paths - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 221
64 Example (IPv6) OS10(conf-router-bgpv6-af)# add-path both 64 Example (Receive) OS10(conf-router-bgpv6-af)# add-path receive Supported Releases 10.2.0E or later address-family Enters global address family configuration mode for the IP address family. Syntax Parameters address-family {[ipv4 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 222
mode. The no version of this command disables the advertisement-start time interval. Example OS10(conf-router-neighbor)# advertisement-start 30 Supported Releases 10.3.0E or later aggregate-address Summarizes a range of prefixes to minimize the number of entries in the routing table. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 223
the best path. The no version of this command resets the value to the default. OS10(conf-router-bgp-10)# always-compare-med Supported Releases 10.2.0E or later bestpath as-path Configures the AS path selection criteria for best path computation. Syntax Parameters bestpath as-path {ignore - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 224
always-compare-med command. The no version of this command resets the MED comparison influence. OS10(conf-router-bgp-2)# bestpath med confed Supported Releases 10.3.0E or later bestpath router-id Ignores comparing router-id information for external paths during the best path selection. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 225
Usage Information Example Not configured EXEC To reset BGP IPv4 or IPv6 neighbor sessions, use this command. OS10# clear ip bgp 1.1.15.4 Supported Releases 10.3.0E or later clear ip bgp * Resets BGP sessions. The soft parameter (BGP soft reconfiguration) clears policies without resetting the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 226
The no version of this command disables route reflection in a cluster. Example OS10(conf-router-bgp-2)# client-to-client reflection Supported Releases 10.2.0E or later bgp connection-retry-timer Configures a peer connection retry timer. Syntax Parameters Default Command Mode Usage Information - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 227
, an integer displays. The no version of this command resets the value to the default. OS10(conf-router-bgp-10)# cluster-id 3.3.3.3 Supported Releases 10.3.0E or later bgp dampening Enables BGP route-flap dampening and configures the dampening parameters. Syntax bgp dampening [half-life | reuse - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 228
the default metric value. OS10(conf-router-bgpv4-af)# default-metric 60 Example (IPv6) OS10(conf-router-bgpv6-af)# default-metric 60 Supported Releases 10.3.0E or later bgp default local-preference Changes the default local preference value for routes exchanged between internal BGP peers - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 229
indirectly connected are not valid for best path selection. The no version of this command removes multihop session. OS10(conf-router-neighbor)# ebgp-multihop 2 Supported Releases 10.3.0E or later enforce-first-as Enforces the first AS in the AS path of the route received from an external border - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 230
unreachability or link failure is detected. This only applies after you manually reset all existing BGP sessions. For the configuration to take effect, external fallover. OS10(conf-router-bgp-10)# fast-external-fallover Supported Releases 10.3.0E or later inherit template Configures a peer group - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 231
, use the show bgp config command. The no version of this command disables the feature. OS10(conf-router-bgp-10)# log-neighbor-changes Supported Releases 10.3.0E or later maximum-paths Configures the maximum number of equal-cost paths for load sharing. Syntax maximum-paths [ebgp number | ibgp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 232
The no version of this command resets the value to the default. OS10(conf-router-bgp-neighbor-af)# maximum-prefix 20 100 warning-only Supported Releases 10.3.0E or later neighbor Creates a remote peer for the BGP neighbor and enters BGP Neighbor mode. Syntax Parameters Default Command Mode Usage - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 233
routes to IBGP peers. The no version of this command disables the nexthop calculation. OS10(conf-router-neighbor-af)# next-hop-self Supported Releases 10.3.0E or later non-deterministic-med Compares paths in the order they arrive. Syntax Parameters Default Command Mode Usage Information Example - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 234
outbound optimization. OS10(conf-router-bgp-10)# outbound-optimization Supported Releases 10.3.0E or later password Configures a password OSPF process (1 to 65535). • static - Enter to redistribute manually configured routes. Default Command Mode Usage Information Example (Connected) Disabled - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 235
removes all clients of a route reflector-the router no longer functions as a route reflector. Example OS10(conf-router-template)# route-reflector-client Supported Releases 10.3.0E or later router bgp Enables BGP and assigns an AS number to the local BGP speaker. Syntax Parameters router bgp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 236
. The no version of this command resets the value to the default. OS10(conf-router-bgp-10)# router-id 10.10.10.40 Supported Releases 10.3.0E or later send-community Sends a community attribute to a BGP neighbor or peer group. Syntax send-community {extended | standard} Parameters • extended - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 237
102)# neighbor 32::1 OS10(conf-router-neighbor)# address-family ipv6 unicast OS10(conf-router-bgp-neighbor-af)# no sender-side-loop-detection Supported Releases 10.3.0E or later show ip bgp Displays information that BGP neighbors exchange. Syntax Parameters Default Command Mode Usage Information - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 238
00 800 9 8 i *> 3.1.5.0/24 80.1.1.2 1 00:00:11 00:00:00 800 9 8 i *> 3.1.6.0/24 80.1.1.2 1 00:00:11 00:00:00 800 9 8 i Total number of prefixes: 5 Supported Releases 10.3.0E or later show ip bgp ipv4 unicast Displays route information for BGP IPv4 routes. Syntax Parameters show ip bgp ipv4 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 239
bgp ipv4 unicast summary BGP router identifier 80.1.1.1 local AS number 102 Neighbor AS MsgRcvd MsgSent Up/Down State/Pfx 80.1.1.2 800 8 4 00:01:10 5 Supported Releases 10.3.0E or later show ip bgp ipv6 unicast Displays route information for BGP IPv6 routes. Syntax show ip bgp ipv6 unicast - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 240
Command Mode Usage Information EXEC • BGP neighbor - Displays the BGP neighbor address and its AS number. The last phrase in the line indicates whether the link between the BGP router and its neighbor is an external or internal one. If they are located in the same AS, the link is internal; - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 241
Example advertisedroutes OS10# show ip bgp ipv6 unicast neighbors 192:168:1::2 advertised-routes BGP local router ID is 100.1.1.1 Status codes: s suppressed, S stale, d dampened, h history, * valid, > best Origin codes: i - IGP, e - EGP, ? - incomplete Network Next Hop Metric LocPrf Weight - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 242
you do not enable the peer group. If you enable the peer group, this line does not display. • BGP version - Displays the BGP version supported. • For address family - Displays IPv4 unicast as the address family. • BGP neighbor - Displays the name of the BGP neighbor. • Number of peers - Displays the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 243
. Syntax soft-reconfiguration inbound Parameters None Default Not configured Command Modes ROUTER-BGP-NEIGHBOR-AF Usage Information This command is not supported on a peer-group level. To enable soft-reconfiguration for peers in a peer-group, this command must be enabled at a per-peer - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 244
values negotiate from peers. The no version of this command resets the value to the default. OS10(conf-router-bgp)# timers 30 90 Supported Releases 10.3.0E or later weight Assigns a default weight for routes from the neighbor interfaces. Syntax weight number Parameters number-Enter a number - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 245
Equal cost multi-path ECMP is a routing technique where next-hop packet forwarding to a single destination occurs over multiple best paths. OS10 uses a hashing algorithm to determine the next-hop when you enable ECMP. The hashing algorithm makes hashing decisions based on values in various packet - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 246
across the members. The no version of this command returns the value to the default. Example OS10(config)# hash-algorithm lac crc Supported Releases 10.3.0E or later link-bundle-utilization trigger-threshold Configures a threshold value to trigger monitoring of traffic distribution on an ECMP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 247
load-balancing Distributes or load balances incoming traffic using the default parameters in the hash algorithm. Syntax Parameters load-balancing {ingress-port enable | [tcp-udp-selection l4-destination-port | l4-source-port] | [ip-selection destination-ip | source-ip | protocol | vlan-id | l4- - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 248
show hash-algorithm None Not configured EXEC None OS10# show hash-algorithm EcmpAlgo - crc LabAlgo - xor Supported Releases 10.3.0E or later IPv4 routing OS10 supports IPv4 addressing including variable-length subnetting mask (VLSM), address resolution protocol (ARP), static routing, and routing - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 249
, 0 packets/sec, 0% of line rate Time since last interface status change: 3 weeks 1 day 20:54:37 Configure static routing You can configure a manual or static route for OSPF. • Configure a static route in CONFIGURATION mode. ip route ip-prefix/mask {next-hop | interface interface [route-preference - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 250
mac address-MAC address in nnnn.nnnn.nnnn format 2 Save the configuration. do commit These entries do not age, and you can only remove them manually. To remove a static ARP entry, use the no arp ip-address command. Configure static ARP entries OS10(config)# interface ethernet 1/1/6 OS10(conf-if-eth1 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 251
Mode Usage Information Example Not configured EXEC This command does not remove the static routes from the routing table. OS10# clear ipv6 route 10.1.1.1/24 Supported Releases 10.3.0E or later ip arp Configures static ARP and maps the IP address of the neighbor to a MAC address. Syntax ip arp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 252
Example Not configured CONFIGURATION The no version of this command deletes a static route configuration. OS10(config)# ip route 200.200.200.0/24 10.1.1.2 Supported Releases 10.2.0E or later show ip arp Displays the ARP table entries for specific a IP address or MAC address, static, dynamic, and - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 253
/2 01:16:56 B IN 10.1.4.0/24 via 10.1.4.1 vlan103 200/0 01:16:56 Supported Releases 10.2.0E or later IPv6 routing IPv4 networks can move to IPv6 and receive services such as end-to-end security, quality of service (QoS), and globally unique addresses. The IPv6 address space reduces the need for - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 254
when an organization changes its service provider. As an alternative to The system manipulation of IPv6 stateless autoconfiguration supports the router side only. Neighbor discovery ( appropriate pool. Static routing Static routes are manually configured and define an explicit route between two - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 255
colons(::). For example, you can shorten2001:0db8:0000:0000:0000:0000:1428:57ab to 2001:0db8::1428:57ab. Only one set of double colons is supported in a single address. You can reduce any number of consecutive 0000 groups to two colons, as long as there is only one double colon in - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 256
OS10(conf-if-eth1/1/9)# no ipv6 address Enable static IPv6 routing Determine if you would like to use static IPv6 routing. Static routes are manually configured and define an explicit route between two networking devices. Static routing is useful for smaller networks with only one path to an outside - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 257
B - BGP, IN - internal BGP, EX - external BGP O - OSPF,IA - OSPF inter area, N1 - OSPF NSSA external type 1, N2 - OSPF NSSA external type 2, E1 - OSPF external type 1, E2 - OSPF external type 2, > - non-active route Gateway of last resort is not set Destination Gateway Dist/Metric Last Change - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 258
static routes from the routing table. OS10# clear ipv6 route * Supported Releases 10.3.0E or later ipv6 route Configures a static IPv6 static if you do not assign an IP address to a peer interface, you must manually ping the peer to resolve the neighbor information. The no version of this - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 259
NSSA External-2 0 Ospf External-1 0 Ospf External-2 0 Bgp Internal 0 Bgp External 0 Ospf Intra-area 0 Total 0 Non-Active Routes 0 0 0 0 0 0 0 0 0 0 0 0 0 Supported Releases 10.2.0E or later Open shortest path first OSPF routing is a link-state routing protocol that allows sending of - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 260
Autonomous system areas OSPF operates in a type of hierarchy. The largest entity within the hierarchy is the autonomous system (AS). The AS is a collection of networks under a common administration that share a common routing strategy. OSPF is an intra-AS, interior gateway routing protocol that - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 261
Each router has a unique ID, written in decimal format-A.B.C.D. You do not have to associate the router ID with a valid IP address. To make troubleshooting easier, ensure the router ID is identical to the router's IP address. Backbone router Area border router A backbone router (BR) is part of the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 262
can connect to many areas in an AS and is considered a member of each area it connects to-shown as Router H in the example. Autonomous system The autonomous system border router (ASBR) connects to more than one AS and exchanges information with the border router routers in other ASs. The ASBR - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 263
Type 7-NSSAExternal LSA (OSPFv2), Type-7 LSA (OSPFv3) Routers in an NSSA do not receive external LSAs from ABRs but send external routing information for redistribution. They use Type 7 LSAs to tell the ABRs about these external routes, which the ABR then translates to Type 5 external LSAs and - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 264
OSPF route limit OS10 supports up to 16,000 OSPF routes. Within this range, the only restriction is on intra-area routes that scale only up to 100 routes. Other - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 265
router-id 99.99.99.99 ! ... Assign router identifier For managing and troubleshooting purposes, you can assign a router ID for the OSPF process. Use the # show ip ospf 10 Routing Process ospf 10 with ID 111.2.1.1 Supports only single TOS (TOS0) routes It is an Autonomous System Boundary Router - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 266
SPF algorithm executed 38 times Area ranges are Stub areas Type 5 LSAs are not flooded into stub areas. The ABR advertises a default route into the stub area to which it is attached. Stub area routers use the default route to reach external destinations. 1 Enable OSPF routing and enter ROUTER- - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 267
150.1.1.0 160.1.1.0 150.1.1.1 119 0x80000001 0x58D1 99.99.99.99 312 0x80000001 0x909B Summary ASBR (Area 0) Link ID ADV Router Age Seq# Checksum 10.15.0.1 150.1.1.1 80 0x80000001 0xC5E1 101.101.101.101 99.99.99.99 228 0x80000001 0x89AE Router (Area 2) Link ID ADV Router Age Seq# - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 268
120.1.7.0 99.99.99.99 80 120.1.8.0 99.99.99.99 81 120.1.9.0 99.99.99.99 81 120.1.10.0 99.99.99.99 81 140.1.1.0 99.99.99.99 385 150.1.1.0 99.99.99.99 116 0x80000001 0x80000001 0x80000001 0x80000001 0x80000001 0x80000001 0x83F 0xFC49 0xF153 0xE65D 0x3BFE 0xC26C NSSA External (Area 3) Link ID ADV - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 269
Only select higher convergence levels after speaking with Dell Technical Support. When you disable fast-convergence, origination and arrival LSA do show ip ospf Routing Process ospf 65535 with ID 99.99.99.99 Supports only single TOS (TOS0) routes It is an Autonomous System Border Router It - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 270
Interface parameters To avoid routing errors, interface parameter values must be consistent across all interfaces. For example, set the same time interval for the hello packets on all routers in the OSPF network to prevent misconfiguration of OSPF neighbors. 1 To change the OSPFv2 parameters in - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 271
the OSPF routes included in the OSPF database? • Are the OSPF routes included in the routing table in addition to the OSPF database? Troubleshooting OSPF with show commands • View a summary of all OSPF process IDs enabled in EXEC mode. show running-configuration ospf • View summary information of - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 272
is an IPv4 and IPv6 link-state routing protocol that supports IPv6 and IPv4 unicast address families (AFs). OSPFv3 is disabled Dell recommends using the router's IP address as the router ID for managing and troubleshooting purposes. • Assign the router ID for the OSPFv3 process in ROUTER-OSPFv3 mode - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 273
View OSPFv3 Status OS10(conf-router-ospf# do show ipv6 ospf Configure Stub Areas The Type 5 LSAs are not flooded into stub areas. The ABR advertises a default route into the stub area to which it is attached. Stub area routers use the default route to reach external destinations. 1 Enable OSPFv3 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 274
ADV Router Age Seq# Link ID Interface 199.205.134.103 42 0x80000001 12 ethernet1/1/3 202.254.156.15 54 0x80000001 12 ethernet1/1/3 Enable Passive Interfaces A passive interface is one that does not send or receive routing information. Configuring an interface as a passive interface - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 275
is 70.70.70.1 Backup designated router on this network is 60.60.60.1 (local) Timer intervals configured, Hello 5, Dead 20 Troubleshoot OSPFv3 You can troubleshoot OSPFv3 operations, as well as check questions for any typical issues that interrupt a process. • Is OSPFv3 enabled globally? • Is OSPFv3 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 276
or bandwidth. The no version of this command resets the value to the default. OS10(conf-router-ospf-10)# area 10.10.1.5 default-cost 10 Supported Releases 10.2.0E or later area nssa Defines an area as a NSSA. Syntax Parameters area area-id nssa [default-information-originate | no-redistribution - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 277
configured ROUTER-OSPF The no version of this command disables the route summarizations. OS10(conf-router-ospf-10)# area 0 range 10.1.1.4/8 no-advertise Supported Releases 10.2.0E or later area stub Defines an area as the OSPF stub area. Syntax area area-id stub [no-summary] Parameters • area - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 278
instance number (1 to 65535). Not configured EXEC This command clears all entries in the OSPF routing table. OS10# clear ip ospf 3 process Supported Releases 10.2.0E or later clear ipv6 ospf process Clears all OSPFv3 routing tables. Syntax clear ipv6 ospf {instance-number} process Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 279
-metric configuration. OS10(conf-router-ospf-10)# default-metric 2000 Supported Releases 10.2.0E or later fast-converge Sets the minimum LSA from an OSPF area. OS10(conf-if-vl-10)# ip ospf 10 area 5 Supported Releases 10.2.0E or later ip ospf cost Changes the cost associated with the OSPF - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 280
vendors to ensure that all routers use the same cost. If you manually configure the cost, the calculated cost based on the reference bandwidth configuration. Example OS10(conf-if-vl-10)# ip ospf dead-interval 10 Supported Releases 10.2.0E or later ip ospf hello-interval Sets the time interval - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 281
does not establish. The no version of this command enables the IP OSPF mtu-ignore configuration. OS10(conf-if-vl-10)# ip ospf mtu-ignore Supported Releases 10.2.0E or later ip ospf network Sets the network type for the interface. Syntax ip ospf network {point-to-point | broadcast} Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 282
retransmission. The no version of this command resets the value to the default. Example OS10(conf-if-eth1/1/6)# ip ospf retransmit-interval 20 Supported Releases 10.2.0E or later ip ospf transmit-delay Sets the estimated time required to send a link state update packet on the interface - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 283
The no version of this command resets the value to the default. OS10(config)# router ospfv3 10 OS10(conf-router-ospf-10)# log-adjacency-changes Supported Releases 10.3.0E or later max-metric router-lsa Configures OSPF to advertise a maximum metric on a router so that it is not desired as an - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 284
of this command disables the router ID configuration. Example OS10(config)# router ospfv3 10 OS10(conf-router-ospf-10)# router-id 10.10.1.5 Supported Releases 10.3.0E or later router ospf Enters Router OSPF mode and configures an OSPF instance. Syntax router ospf instance-number 284 Layer 3 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 285
for a specified instance number (1 to 65535) Not configured EXEC None OS10# show ip ospf Routing Process ospf 65535 with ID 99.99.99.99 Supports only single TOS (TOS0) routes It is an Autonomous System Border RouterIt is an Area Border Router It is Flooding according to RFC 2328 Convergence - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 286
Default Not configured Command Mode EXEC Usage Information You can isolate problems with external routes. External OSPF routes are calculated by adding 1 110.1.1.2 111.2.1.1 E/-/-/ 0 0.0.0.0 Interface Area Vl 3050 0 Supported Releases 10.2.0E or later show ip ospf database Displays all LSA - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 287
112.2.1.1 112.2.1.1 1282 0x8000000b 0x0485 3 112.112.112.1 112.112.112.1 1305 0x80000250 0xbab2 1 112.112.112.2 112.112.112.2 1305 0x80000250 0xbeaa 1 Network (Area 0) Link ID 110.1.1.2 111.1.1.1 111.2.1.1 112.1.1.1 112.2.1.1 ADV Router 112.2.1.1 111.2.1.1 111.2.1.1 112.2.1.1 112.2.1.1 Age - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 288
120.1.5.0 99.99.99.99 79 120.1.6.0 99.99.99.99 79 120.1.7.0 99.99.99.99 79 120.1.8.0 99.99.99.99 79 120.1.9.0 99.99.99.99 79 120.1.10.0 99.99.99.99 79 150.1.1.0 99.99.99.99 114 160.1.1.0 99.99.99.99 313 0x80000001 0x80000001 0x80000001 0x80000001 0x80000001 0x80000001 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 289
type: Summary Asbr Link State ID: 8.1.1.1 Advertising Router: 2.2.2.2 LS Seq Number: 0x80000001 Checksum: 0xB595 Length: 28 Network Mask: /0 TOS: 0 Metric: 0 Supported Releases 10.2.0E or later show ip ospf database external Displays information about the AS external (Type 5) LSAs. Syntax show - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 290
ID: 13.1.1.0 Advertising Router: 2.2.2.2 LS Seq Number: 0x80000001 Checksum: 0xAEF8 Length: 36 Network Mask: /24 Metric Type: 2 TOS: 0 Metric: 20 Forward Address: 0.0.0.0 External Route Tag: 0 Supported Releases 10.2.0E or later 290 Layer 3 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 291
Link State ID: 10.10.10.2 Advertising Router: 2.2.2.2 LS Seq Number: 0x80000001 Checksum: 0xF32C Length: 32 Network Mask: /24 Attached Router: 1.1.1.1 Supported Releases 10.2.0E or later show ip ospf database nssa external Displays information about the NSSA-External (Type 7) LSA. Syntax show - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 292
Parameters Default Command Mode Usage Information process-id - (Optional) Displays NSSA-External (Type7) LSA information for a specified OSPF Process ID. If you do not enter a Process ID, this command applies only to the first OSPF process. Not configured EXEC • LS Age - Displays the LS age. • - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 293
LS Seq Number: 0x80000001 Checksum: 0xA303 Length: 36 Network Mask: /24 Metric Type: 2 TOS: 0 Metric: 20 Forward Address: 0.0.0.0 External Route Tag: 0 Supported Releases 10.2.0E or later show ip ospf database opaque-area Displays information about the opaque-area (Type 10) LSA. Syntax show ip - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 294
-10 Area Local Opaque Link State ID: 8.1.1.2 Advertising Router: 2.2.2.2 LS Seq Number: 0x80000008 Checksum: 0x83B8 Length: 28 Opaque Type: 8 Opaque ID: 65794 !! ! Supported Releases 10.2.0E or later show ip ospf database opaque-as Displays information about the opaque-as (Type 11) LSAs. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 295
-9 Link Local Opaque Link State ID: 8.1.1.1 Advertising Router: 2.2.2.2 LS Seq Number: 0x80000007 Checksum: 0x9DA1 Length: 28 Opaque Type: 8 Opaque ID: 65793 Supported Releases 10.2.0E or later show ip ospf database router Displays information about the router (Type 1) LSA. Syntax show ip ospf - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 296
(Link ID) Designated Router address: 10.10.10.1 (Link Data) Router Interface address: 10.10.10.2 Number of TOS metric: 0 TOS 0 Metric: 1 Supported Releases 10.2.0E or later show ip ospf database summary Displays the network summary (Type 3) LSA routing information. Syntax show ip ospf [process - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 297
Default Command Mode Usage Information Not configured EXEC • LS Age-Displays the LS age. • Options-Displays the optional capabilities available on the router. • LS Type-Displays the Link State type. • Link State ID-Identifies the router ID. • Advertising Router-Identifies the advertising router's - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 298
configured, Hello 10, Dead 40, Wait 40, Retransmit 5 Neighbor Count is 1, Adjacent neighbor count is 1 Adjacent with neighbor 2.2.2.2(Designated Router) Supported Releases 10.2.0E or later show ip ospf statistics Displays the OSPF statistics information. Syntax • show ip ospf [process-id - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 299
-mismatch 0 area-mismatch 0 hello-err 0 wrong-proto 0 lsa-bad-type 0 auth-fail 0 dead-ivl-mismatch 0 own-hello-drop 0 checksum-error 0 Supported Releases 10.2.0E or later show ip ospf topology Displays routers which are directly connected to OSPF areas. Syntax Parameters Default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 300
accept the LSA. The no version of this command resets the value to the default. OS10(conf-router-ospf-1)# timers lsa arrival 2000 Supported Releases 10.2.0E or later timers throttle lsa all Configures the LSA transmit intervals. Syntax Parameters timers lsa all [start-innterval | hold-interval - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 301
The no version of this command deletes a stub area. OS10(config)# router ospfv3 10 OS10(conf-router-ospfv3-10)# area 10.10.1.5 stub Supported Releases 10.3.0E or later auto-cost reference-bandwidth Calculates default metrics for the interface based on the configured auto-cost reference bandwidth - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 302
no version of this command resets the value to the default. Example OS10(config)# router ospfv3 10 OS10(conf-router-ospf-10)# maximum-paths 1 Supported Releases 10.3.0E or later ipv6 ospf area Attaches an interface to an OSPF area. Syntax Parameters ipv6 ospf process-id area area-id • process - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 303
no version of this command removes the IPv6 OSPF cost configuration. OS10(config)# interface vlan 10 OS10(conf-if-vl-10)# ipv6 ospf cost 10 Supported Releases 10.3.0E or later ipv6 ospf dead-interval Sets the time interval since the last hello-packet was received from a router. After the interval - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 304
of the this command resets the value to the default. OS10(config)# interface vlan 10 OS10(conf-if-vl-10)# ipv6 ospf hello-interval 30 Supported Releases 10.3.0E or later ipv6 ospf network Sets the network type for the interface. Syntax Parameters ipv6 ospf network {point-to-point | broadcast - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 305
10 OS10(conf-router-ospf-10)# redistribute bgp 4 route-map dell1 Example (Connected) OS10(conf-router-ospf-10)# redistribute connected route-map dell2 Supported Releases 10.3.0E or later router-id Configures a fixed router ID for the OSPFv3 process. Syntax router-id ip-address Parameters ip - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 306
version of this command disables the router ID configuration. OS10(config)# router ospfv3 10 OS10(conf-router-ospf-10)# router-id 10.10.1.5 Supported Releases 10.3.0E or later router ospfv3 Enters Router OSPFv3 mode and configures an OSPFv3 instance. Syntax Parameters Default Command Mode Usage - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 307
Number of area in this router is 1, normal 1 stub 0 nssa Area (0.0.0.0) Number of interface in this area is 1 SPF algorithm executed 3 times Supported Releases 10.3.0E or later show ipv6 ospf database Displays all LSA information. You must enable OSPFv3 to generate output. Syntax show ipv6 ospf - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 308
intervals configured, Hello 10, Dead 40, Wait 40, Retransmit 5 Neighbor Count is 1, Adjacent neighbor count is 1 Adjacent with neighbor 2.2.2.2(Designated Router) Supported Releases 10.3.0E or later show ipv6 ospf neighbor Displays a list of OSPFv3 neighbors connected to the local router. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 309
Object tracking manager Object tracking manager (OTM) allows you to track the link status of Layer 2 interfaces, and the reachability of IP and IPv6 hosts. You can increase the availability of the network and shorten recovery time if an object state goes Down. Object tracking monitors the status of - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 310
Interface tracking You can create an object that tracks the line-protocol state of a Layer 2 or Layer 3 interface, and monitors its operational status (Up or Down). You can configure up to 500 objects. Each object is assigned a unique ID. The no version of this command deletes the tracked object - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 311
in communicating a state change is specified in seconds. Object tracking As a client, VRRP can track up to 20 interface objects plus 12 tracked interfaces supported for each VRRP group. You can assign a unique priority-cost value from 1 to 254 to each tracked VRRP object or group interface. The - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 312
In VRRP object tracking, the sum of the priority costs for all tracked objects and interfaces cannot equal or exceed the priority of the VRRP group. View tracked objects You can view the status of currently tracked Layer 2 or Layer 3 interfaces, or the IPv4 or IPv6 hosts. View brief object - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 313
Not configured Command Mode CONFIGURATION Usage Information None Example OS10(config)# track 100 OS10(conf-track-100)# ip 10.10.10.1 reachability Supported Releases 10.3.0E or later ipv6 reachability Configures an object to track a specific next-hop host's reachability. Syntax ipv6 host-ip - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 314
Command Mode CONFIGURATION Usage Information Set the interval to 0 to disable the refresh. Example OS10(conf-track-100)# reachability-refresh 600 Supported Releases 10.3.0E or later show track Displays tracked object information. Syntax show track [brief] [object-id] [interface] [ip | ipv6 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 315
to track (up to 500). Not configured CONFIGURATION The no version of this command deletes the tracked object from an interface. OS10# track 100 Supported Releases 10.3.0E or later Policy-based routing Policy-based routing (PBR) provides a mechanism to redirect IPv4 and IPv6 data packets based on - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 316
Configure IPv4 access-list to match route-map OS10(config)# ip access-list acl5 OS10(conf-ipv4-acl)# permit ip 10.10.10.0/24 any OS10(conf-ipv4-acl)# do commit Configure IPv6 access-list to match route-map OS10(config)# ipv6 access-list acl8 OS10(conf-ipv6-acl)# permit ipv6 10::10 any OS10(conf-ipv6 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 317
140 characters). None EXEC Use the clear route-map pbr-statistics command to clear all PBR counters. OS10# clear route-map map1 pbr-statistics Supported Releases 10.3.0E or later match address Matches the access-list to the route-map. Syntax Parameters Defaults match {ip | ipv6} address [name - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 318
route-map (up to 140 characters). Defaults Not configured Command Mode CONFIGURATION Usage Information None Example OS10(config)# route-map map1 pbr-statistics Supported Releases 10.3.0E or later set next-hop Sets an IPv4 or IPv6 next-hop address for policy-based routing. Syntax Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 319
Mode Usage Information Example Not configured ROUTE-MAP None OS10(conf-route-map)# set ip next-hop 10.10.10.10 track-id 12 Supported Releases 10.3.0E or later show policy Displays policy information. Syntax Parameters Defaults Command Mode Usage Information Example show {ip | ipv6} policy [map - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 320
. VRRP advantages in ease of administration and network throughput and reliability: • Provides a virtual default routing platform • Provides load balancing • Supports multiple logical IP subnets on a single LAN segment • Enables simple traffic routing without the single point of failure of a static - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 321
to the Internet. Router B receives and forwards packets on interface ethernet 1/1/5. Until Router A resumes operation, VRRP allows Router B to provide uninterrupted service to the users on the LAN segment accessing the Internet. Create virtual router VRRP uses the VRID to identify each virtual - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 322
Use the version both command in Configuration mode to migrate from VRRPv2 to VRRPv3. When you set the VRRP version to version both, the switch sends only VRRPv3 advertisements but can receive VRRPv2 or VRRPv3 packets. 1 Set the switch with the lowest priority to version both. 2 Set the switch with - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 323
3 Save the configuration. do commimt Configure virtual IP address OS10(config)# interface ethernet 1/1/1 OS10(conf-if-eth1/1/1)# no switchport OS10(conf-if-eth1/1/1)# ip address 10.1.1.1/24 OS10(conf-if-eth1/1/1)# vrrp-group 10 OS10(conf-eth1/1/1-vrid-10)# virtual-address 10.1.1.8 OS10(conf-eth1 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 324
group with the same password. You must enable authentication with the same password or authentication is disabled. Authentication for VRRPv3 is not supported. 1 Create a virtual router for the interface with the VRRP identifier in INTERFACE mode (1 to 255). vrrp-group vrrp-id 2 Configure a simple - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 325
at Sep 24 07:17:45 2016 ! debug radius false snmp-server contact http://www.dell.com/support/softwarecontacts snmp-server location "United States" username admin password $6$q9QBeYjZ$jfxzVqGhkxX3smxJSH9DDz7/3OJc6m5wjF8nnLD7/VKx8SloIhp4NoGZs0I/ UNwh8WVuxwfd9q4pWIgNs5BKH. aaa authentication system - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 326
10.1.1.1 ! interface ethernet1/1/2 switchport access vlan 1 no shutdown Interface/object tracking You can monitor the state of any interface according to the virtual group. OS10 supports a maximum of 10 track groups and each track group can track a maximum of five interfaces. 326 Layer 3 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 327
If the tracked interface goes down, the VRRP group's priority decreases by a default value of 10 - also known as cost. If the tracked interface's state goes up, the VRRP group's priority increases by priority-cost. The lowered priority of the VRRP group may trigger an election. As the Master/Backup - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 328
interval back to its default value (1 second or 100 centisecs). OS10(conf-eth1/1/6-vrid-250)# advertise-interval 120 centisecs 100 Supported Releases 10.2.0E or later authentication-type Enables authentication of VRRP data exchanges. Syntax authentication-type simple-text password [auth-text - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 329
if the original Master recovers or the new Master fails. The no version of this command disables preemption. OS10(conf-eth1/1/5-vrid-254)# preempt Supported Releases 10.2.0E or later priority Assigns a VRRP priority value for the VRRP group. The VRRP protocol uses this value during the master - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 330
-ttl-errors : 0 priority-zero-pkts-rcvd : 0 priority-zero-pkts-sent : 0 invalid-type-pkts-rcvd : 0 address-list-errors : 0 pkt-length-errors : 0 Supported Releases 10.2.0E or later track Assigns a unique identifier to track an object. Syntax track track-id [priority cost [value]] Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 331
for interface operational status information. The no version of this command resets the value to the default. OS10# track-interface ethernet 1/1/5 line-protocol Supported Releases 10.2.0E or later virtual-address Configures up to 10 virtual router IP addresses in the VRRP group. Set at least one - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 332
to all the VRRP configured interfaces. The no version of this command resets the value to the default. OS10(config)# vrrp delay reload 5 Supported Releases 10.2.0E or later vrrp-group Assigns a VRRP group identification number to an IPv4 interface or VLAN Syntax vrrp-group vrrp-id Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 333
OS10(conf-if-eth1/1/7)# vrrp-ipv6-group 250 Supported Releases 10.2.0E or later vrrp version Sets the VRRP protocol version for the IPv4 group. Syntax vrrp version {2 | both | 3} Parameters • 2 - Set to VRRP version 2. • both - Allows in-service migration from VRRP version 2 to VRRP version - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 334
5 System management Dynamic host configuration protocol Provides information to dynamically assign IP addresses and other configuration parameters to network hosts based on policies (see DHCP commands). Network time protocol Provides information about how to synchronize timekeeping between time - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 335
The table shows common options using DHCP packet formats. Subnet mask 1 - Client's subnet mask Router 3 - Router IP addresses that serve as the client's default gateway Domain name server 6 - Domain name servers (DNS) that are available to the client Domain name 15 - Domain name that clients - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 336
it easier to add new devices to the network. The DHCP access service minimizes the overhead required to add clients to the network by providing a centralized, server-based setup. This setup means you do not have to manually create and maintain IP address assignments for clients. When you use DHCP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 337
conf-dhcp-Dell)# do commit Hostname resolution You have two choices for hostname resolution - domain name server (DNS) or NetBIOS Windows internet naming service (WINS). Both DHCP and WINS clients query IP servers to compare host names to IP addresses. 1 Enable DHCP server-assigned dynamic addresses - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 338
Dell OS10(conf-dhcp-Dell)# netbios-name-server 192.168.10.5 OS10(conf-dhcp-Dell)# netbios-node-type Hybrid OS10(conf-dhcp-Dell)# do commit Manual binding entries Address binding is mapping between the IP address and the media access control (MAC) address of a client. The DHCP server assigns the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 339
OS10(conf-dhcp-static)# hardware-address 00:01:e8:8c:4d:0a OS10(conf-dhcp-static)# do commit View DHCP binding table OS10# show ip dhcp binding IP Address Hardware address Lease expiration Hostname 11.1.1.254 00:00:12:12:12:12 Jan 27 2016 06:23:45 Total Number of Entries in the Table = 1 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 340
-server 1.1.1.1 2::2 ip host dell-f10.com 10.10.10.10 snmp-server community public read-only snmp-server contact http://www.dell.com/support/ snmp-server location United States debug radius false DHCP commands default-router address Assigns a default gateway to clients based on the IP address pool - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 341
address [address2...address8] • address - Enter the DNS server IP address that services clients on the subnet in A.B.C.D or A::B format. • address2...address8 - dell.com Supported Releases 10.2.0E or later hardware-address Configures the client hardware address for manual configurations. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 342
a host to a single IPv4 or IPv6 address pool for manual configurations. Syntax Parameters Default Command Mode Usage Information Example host by the client machine for DHCP. OS10(conf-dhcp-Dell)# host 20.1.1.100 Supported Releases 10.2.0E or later ip dhcp server Enters DHCP mode. Syntax ip - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 343
order of preference. The no version of this command returns the value to the default. OS10(conf-dhcp-Dell)# netbios-name-server 192.168.10.5 Supported Releases 10.2.0E or later netbios-node-type Configures the NetBIOS node type for the DHCP client. Syntax Parameters netbios-node-type type type - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 344
CONFIGURATION Usage Information Use this command to create an IP address pool name. Example OS10(conf-dhcp)# pool Dell OS10(conf-dhcp-Dell)# Supported Releases 10.2.0E or later show ip dhcp binding Displays the DHCP binding table with IPv4 addresses. Syntax show ip dhcp binding Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 345
host names. The no version of this command removes a domain name from the DNS list. OS10(config)# ip domain-list jay dell.com Supported Releases 10.2.0E or later ip domain-name Configures the default domain and appends to incomplete DNS requests. Syntax Parameters Default Command Mode Usage - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 346
table uses this mapping information to resolve host names. The no version of this command disables the mapping. OS10(config)# ip host dell 1.1.1.1 Supported Releases 10.2.0E or later ip name-server Configures up to a three IPv4 or IPv6 addresses used for network name servers. Syntax ip name - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 347
dell.com Domain List : abc.com Name Servers : 1.1.1.1 20::2 Static Host to IP mapping Table Host IP-Address dell-pc1 20.1.1.1 Supported Releases 10.2.0E or later Network time protocol NTP synchronizes timekeeping among a set of distributed time servers and clients. The protocol - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 348
Enable NTP NTP is disabled by default. To enable NTP, configure an NTP server to which the system synchronizes. To configure multiple servers, enter the command multiple times. Multiple servers may impact CPU resources. 1 Enter the IP address of the NTP server to which the system synchronizes in - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 349
an IPv4 address in A.B.C.D format. • ipv6-address - Enter an IPv6 address in nnnn:nnnn:nnnn:nnnn:nnnn:nnnn:nnnn:nnnn format (elision of zeros is supported). • key keyid - Enter a text string as the key exchanged between the NTP server and the client. System management 349 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 350
traffic using the ntp authentication-key command. The no version of this command disables NTP authentication. OS10(config)# ntp authenticate Supported Releases 10.2.0E or later ntp authenticate-key Configures the authentication key for trusted time sources. Syntax ntp authenticate-key number - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 351
ntp broadcast client None Not configured INTERFACE The no version of this command disables broadcast. OS10(conf-if-eth1/1/1)# ntp broadcast client Supported Releases 10.2.0E or later ntp disable By default, NTP is enabled on all interfaces. Prevents an interface from receiving NTP packets - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 352
the number of hosts you configure, as many polls to the NTP hosts can impact network performance. OS10(config)# ntp server eureka.com Supported Releases 10.2.0E or later ntp source Configures an interface IP address to include in NTP packets. Syntax Parameters ntp source interface interface - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 353
-key command, you must also change this command. The no version of this command removes the key. OS10(config)# ntp trusted-key 234567 Supported Releases 10.2.0E or later show ntp associations Displays the NTP master and peers. Syntax Parameters Default Command Mode Usage Information show ntp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 354
Mon, Jan 1 1900 0:00:00.000 system flags: monitor ntp kernel stats jitter: 0.000000 s stability: 0.000 ppm broadcastdelay: 0.000000 s authdelay: 0.000000 s Supported Releases 10.2.0E or later System clock OS10 uses NTP to synchronize the system clock with a time-serving host. If you do - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 355
system clock setting is applied immediately. It is not necessary to commit the change. OS10# clock set 18:30:10 2017-01-25 Supported Releases 10.2.1E or later show clock Displays the current system clock settings. Syntax show clock Parameters None Default Not configured Command Mode EXEC - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 356
regular power mode only during data transmission. EEE is enabled on devices that support LOW POWER IDLE (LPI) mode. Such devices can save power by entering LPI on both ends of the link saves power by shutting down certain services. EEE transitions into and out of LPI mode transparently to upper- - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 357
Clear counters for specific interface OS10# clear counters interface 1/1/48 eee Clear eee counters on ethernet1/1/48 [confirm yes/no]:yes View EEE status/statistics You can view the EEE status or statistics for a specified interface, or all interfaces, using show commands. View EEE status for a - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 358
EXEC Use this command to clear all EEE counters. OS10# clear counters interface eee Clear all eee counters [confirm yes/no]:yes Supported Releases 10.3.0E or later clear counters interface ethernet eee Clears EEE counters on a specified interface. Syntax clear counters interface ethernet node - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 359
up 1000M ... Eth 1/1/47 on up 1000M Eth 1/1/48 on up 1000M Eth 1/1/49 n/a Eth 1/1/50 n/a Eth 1/1/51 n/a Eth 1/1/52 n/a Supported Releases 10.3.0E or later show interface eee statistics Displays EEE statistics for all interfaces. Syntax show interface eee statistics Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 360
A switch in a Layer 2 network may require a larger MAC address table size, while a switch in a Layer 3 network may require a larger routing table size. OS10 supports several UFT modes for the forwarding tables. By default, OS10 selects a UFT mode which provides a reasonable size for all tables. The - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 361
UFT Mode Default L2 MAC Table Size 163840 L3 Host Table Size 147456 L3 Routes Table Size 16384 Table 3. UFT Modes - Table Size for S3000 UFT Mode L2 MAC Table Size Scaled-l2-switch 40960 Scaled-l3-hosts 8192 Default 28672 L3 Host Table Size 2048 18432 8192 L3 Routes Table Size 8192 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 362
You need to save the configuration and reload the switch to apply the changes. OS10(config)# hardware forwarding-table mode scaled-l3-hosts Supported Releases 10.3.0E or later show hardware forwarding-table mode Displays the current hardware forwarding table mode and the mode after the next boot - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 363
help secure networks against unauthorized access, OS10 supports remote authentication dial-in service (RADIUS) client/server authentication mechanism. The (user credentials verification), and authorization (user privilege level) services. You can configure the security protocol used for different - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 364
role, you are authenticated and authorized. You do not need to enter an enable password because you are automatically placed in EXEC mode. OS10 supports the constrained RBAC model. With this model, you can inherit permissions when you create a new user role, restrict or add commands a user can enter - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 365
2 Configure the number of times OS10 retransmits RADIUS requests in CONFIGURATION mode (0 to 100, default 3). radius-server retransmit retries 3 Configure the time interval in seconds OS10 waits for a RADIUS server host response in CONFIGURATION mode (0 to 1000, default 5). radius-server timeout - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 366
Example Not configured CONFIGURATION The no version of this command resets the value to the default. OS10(config)# aaa authentication radius Supported Releases 10.2.0E or later radius-server host Configures the RADIUS server hostname. Syntax radius-server host [hostname | ip-address] [auth - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 367
server. Not configured CONFIGURATION The no version of this command resets the value to the default. OS10(config)# radius-server key md5 Supported Releases 10.2.0E or later radius-server retransmit Configures the number of attempts to retry the RADIUS server. Syntax Parameters Default Command - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 368
users Index Line User Role Application Idle Location Login-Time Lock 1 ttyS0 admin sysadmin login/clish . - 2016-04-29 01:02:00 Supported Releases 10.2.0E or later username Creates an authentication system based on user names. Syntax Parameters username username password [encryption-type - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 369
of this command removes access to a community. OS10(config)# snmp-server community public ro Supported Releases 10.2.0E or later snmp-server contact Configures contact information for troubleshooting this SNMP node. Syntax snmp-server contact text Parameters text - Enter an alphanumeric text - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 370
current running configuration to the startup configuration in EXEC mode. copy running-configuration startup-configuration 2 Download the new software image from dell.com/support and save the file in EXEC mode. image download file-url 3 Install the new software image in EXEC mode. image install image - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 371
boot command to view the configured next boot image. This command is applied immediately and does not require the commit command. OS10# boot system standby Supported Releases 10.2.0E or later image cancel Cancels an active image download. Syntax image cancel System management 371 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 372
Command Mode Usage Information Example None Not configured EXEC This command attempts to cancel an active file download in progress. OS10# image cancel Supported Releases 10.2.0E or later image copy Copies the entire image in the active partition to the standby partition (mirror image). Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 373
status command to view the installation progress. OS10# image install ftp://10.206.28.174/PKGS_OS10-Enterprise-10.2.0E.190installer-x86_64.bin Supported Releases 10.2.0E or later image upgrade Upgrades to software image. Syntax image upgrade file-url Parameters • file-url - Location of the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 374
:11:14Z Standby Partition: A Standby SW Version: 10.2.0E Standby Build Date/Time: 2016-10-03T23:11:14Z Next-Boot: active[B] Supported Releases 10.2.0E or later show image status Displays image transfer and installation information. Syntax show image status Parameters None Default Not - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 375
: idle State Detail: No install information available Task Start: 0000-00-00T00:00:00Z Task End: 0000-00-00T00:00:00Z Supported Releases 10.2.0E or later show version Displays software version information. Syntax Parameters Default Command Mode Usage Information Example show version - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 376
(CAM) without disrupting traffic flow. Existing entries in the CAM are shuffled to accommodate the new entries. Hot lock ACLs are enabled by default and support ACLs on all platforms. 376 Access Control Lists - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 377
VLAN ID Set in the packet header Class of service (CoS) Present in the packet header IPv4/IPv6 per ACL type. IP fragment handling OS10 supports a configurable option to explicitly deny IP fragmented packet size limit. This provides a particular problem for ACL processing. If the ACL is - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 378
Permit all packets on interface OS10(config)# ip access-list ABC OS10(conf-ipv4-acl)# permit ip any 10.1.1.1/32 OS10(conf-ipv4-acl)# deny ip any 10.1.1.1/32 fragments L3 ACL rules Use ACL commands for Layer 3 (L3) packet filtering. TCP packets from host 10.1.1.1 with TCP destination port equal to 24 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 379
Assign sequence number to filter IP ACLs filter on source and destination IP addresses, IP host addresses, TCP addresses, TCP host addresses, UDP addresses, and UDP host addresses. Traffic passes through the filter by filter sequence. Configure the IP ACL by first entering IP ACCESS-LIST mode and - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 380
• Egress L2 ACL L2 and L3 targeted traffic L2 ACL / L3 ACL Deny / Deny Deny / Permit Permit / Deny Permit / Permit Targeted traffic L3 ACL denies L3 ACL permits L3 ACL denies L3 ACL permits Assign and apply ACL filters You can assign an IP ACL filter to a physical interface to filter an Ethernet - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 381
filters onto each interface and achieves the same results. You can use an egress ACL filter to restrict egress traffic. For example, when a denial of service (DOS) attack traffic is isolated to a specific interface, you can apply an egress ACL filter to block the flow from exiting the network and - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 382
Apply rules to ACL filter OS10(config)# interface ethernet 1/1/29 OS10(conf-if-eth1/1/29)# ip access-group egress out OS10(conf-if-eth1/1/29)# exit OS10(config)# ip access-list egress OS10(conf-ipv4-acl)# seq 10 deny ip any any count fragment OS10(conf-ipv4-acl)# do commit View IP ACL filter - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 383
• After a route matches a filter, the filter's action applies and no additional filters apply to the route Use prefix-lists in processing routes for routing protocols such as OSPF, RTM, and BGP. To configure a prefix-list, use commands in PREFIX-LIST and ROUTER-BGP modes. Create the prefix-list in - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 384
• If a route matches a prefix-list set to permit, the route is denied View both IP prefix-list and route-map OS10(conf-router-bgp-neighbor-af)# do show ip prefix-list ip prefix-list p1: seq 1 deny 10.1.1.0/24 seq 10 permit 0.0.0.0/0 le 32 ip prefix-list p2: seq 1 permit 10.1.1.0/24 seq 10 permit - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 385
(config)# route-map ip permit 1 OS10(conf-route-map)# match metric 2567 OS10(conf-route-map)# do commit continue Clause Only BGP route-maps support the continue clause. When a match is found, set clauses run and the packet is forwarded - no routemap processing occurs. If you configure the continue - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 386
an ACL on the source port or the monitored port, both flow-based monitoring and port mirroring do not function. Flow-based monitoring is supported only for ingress traffic and not for egress packets. The show monitor session session-id command displays output which indicates if a particular session - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 387
of packets matching an access-list. Use the show access-lists command to view accesslist information. Example OS10# clear ip access-list counters Supported Releases 10.2.0E or later clear ipv6 access-list counters Clears IPv6 access-list counters for a specific access-list. Syntax clear ipv6 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 388
count of packets matching an access-list. Use the show access-lists command to view access-list information. OS10# clear ipv6 access-list counters Supported Releases 10.2.0E or later clear mac access-list counters Clears counters for a specific or all MAC access-lists. Syntax clear mac access - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 389
this command removes the filter. OS10(config)# ip access-list testflow OS10(conf-ipv4-acl)# deny udp any any capture session 1 count Supported Releases 10.2.0E or later deny (IPv6) Configures a filter to drop packets with a specific IPv6 address. Syntax Parameters deny [protocol-number | icmp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 390
filter. OS10(config)# mac access-list macacl OS10(conf-mac-acl)# deny any any cos 7 OS10(conf-mac-acl)# deny any any vlan 2 Supported Releases 10.2.0E or later deny icmp Configures a filter to drop all or specific internet control message protocol (ICMP) messages. Syntax Parameters deny icmp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 391
no version of this command removes the filter. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# deny icmp any any capture session 1 count Supported Releases 10.2.0E or later deny ip Configures a filter to drop all or specific packets from an IPv4 address. Syntax Parameters deny ip - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 392
no version of this command removes the filter. OS10(config)# ip access-list testflow OS10(conf-ipv4-acl)# deny ip any any capture session 1 count Supported Releases 10.2.0E or later deny ipv6 Configures a filter to drop all or specific packets from an IPv6 address. Syntax Parameters deny ipv6 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 393
no version of this command removes the filter. OS10(config)# ip access-list testflow OS10(conf-ipv4-acl)# deny tcp any any capture session 1 count Supported Releases 10.2.0E or later deny tcp (IPv6) Configures a filter that drops TCP IPv6 packets meeting the filter criteria. Syntax deny tcp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 394
of this command removes the filter. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# deny tcp any any capture session 1 count Supported Releases 10.2.0E or later deny udp Configures a filter to drop user datagram protocol (UDP) packets meeting the filter criteria. Syntax Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 395
command removes the filter. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# deny udp any any capture session 1 count Supported Releases 10.2.0E or later description Configures an ACL description. Syntax description text Parameters text - Enter the description text string (up to - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 396
Example Disabled IPV4-ACL, IPV6-ACL, MAC-ACL The no version of this command deletes the ACL description. OS10(conf-ipv4-acl)# description ipacltest Supported Releases 10.2.0E or later ip access-group Assigns an IP access list (IP ACL) to an interface. Syntax ip access-group access-list-name - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 397
if deny and a regexp are specified. Otherwise, the entire access list is removed. Example OS10(config)# ip as-path access-list abc deny 123 Supported Release 10.3.0E or later ip as-path permit Defines a BGP access-list. Syntax ip as-path access-list name permit ASNumber Parameters • name - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 398
Not configured CONFIGURATION The no version of this command removes the community list. OS10(config)# ip community-list standard STD_LIST permit local-AS Supported Release 10.3.0E or later ip extcommunity-list standard deny Creates an extended community list for BGP to deny access. Syntax ip - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 399
version of this command removes the extended community list. OS10(config)# ip extcommunity-list standard STD_LIST permit 4byteas-generic transitive 1.65412:60 Supported Release 10.3.0E or later ip prefix-list description Configures a description of an IP prefix list. Syntax ip prefix-list name - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 400
The no version of this command removes the specified prefix-list. OS10(config)# ip prefix-list allowprefix permit 10.10.10.1/16 ge 10 Supported Release 10.3.0E or later ip prefix-list seq deny Configures a filter to deny route filtering from a specified prefix list. Syntax ip prefix-list - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 401
no version of this command removes the specified prefix list. OS10(config)# ip prefix-list seqprefix seq 65535 permit 10.10.10.1/16 le 30 Supported Release 10.3.0E or later ipv6 access-group Assigns an IPv6 access list to an interface. Syntax ipv6 access-group access-list-name {in | out - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 402
Example Not configured INTERFACE The no version of this command deletes an IPv6 ACL configuration. OS10(conf-if-eth1/1/8)# ipv6 access-group test6 in Supported Releases 10.2.0E or later ipv6 access-list Creates an IP access list (IP ACL) to filter based on an IPv6 address. Syntax ipv6 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 403
The no version of this command removes the specified prefix-list. OS10(config)# ipv6 prefix-list TEST permit AB20::1/128 ge 10 le 30 Supported Release 10.3.0E or later ipv6 prefix-list seq deny Configures a filter to deny route filtering from a specified prefix-list. Syntax ipv6 prefix-list - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 404
config)# ipv6 prefix-list TEST seq 65535 deny AB20::1/128 ge 10 Supported Release 10.3.0E or later ipv6 prefix-list seq permit Configures a OS10(config)# ipv6 prefix-list TEST seq 65535 permit AB10::1/128 ge 30 Supported Release 10.3.0E or later mac access-group Assigns a MAC access list - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 405
name - Enter the name of a MAC access list (up to 140 characters). Not configured CONFIGURATION None OS10(config)# mac access-list maclist Supported Releases 10.2.0E or later permit Configures a filter to allow packets with a specific IP address. Syntax Parameters permit [protocol-number | icmp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 406
of this command to remove the filter. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# permit udp any any capture session 1 count Supported Releases 10.2.0E or later permit (MAC) Configures a filter to allow packets with a specific MAC address. Syntax permit {nn:nn:nn:nn:nn:nn - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 407
:11:11:11:11 any cos 7 OS10(conf-mac-acl)# permit 00:00:00:00:11:11 00:00:11:11:11:11 any vlan 2 Supported Releases 10.2.0E or later permit icmp Configures a filter to permit all or specific internet control message protocol (ICMP) messages. Syntax Parameters permit icmp - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 408
of this command to remove the filter. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# permit icmp any any capture session 1 count Supported Releases 10.2.0E or later permit ip Configures a filter to permit all or specific packets from an IP address. Syntax Parameters permit ip - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 409
increment. Use the no version of this command to remove the filter. OS10(conf-ipv4-acl)# permit ip any any capture session 1 count Supported Releases 10.2.0E or later permit ipv6 Configures a filter to permit all or specific packets from an IPv6 address. Syntax permit ipv6 [A::B | A::B/x | any - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 410
increment. Use the no version of this command to remove the filter. OS10(conf-ipv4-acl)# permit tcp any any capture session 1 count Supported Releases 10.2.0E or later permit tcp (IPv6) Configures a filter to permit TCP packets meeting the filter criteria. Syntax permit tcp [A::B | A::B/x | any - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 411
version of this command to remove the filter. OS10(config)# ip access-list testflow OS10(conf-ipv4-acl)# permit udp any any capture session 1 count Supported Releases 10.2.0E or later Access Control Lists 411 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 412
. Use the no version of this command to remove the filter. OS10(conf-ipv6-acl)# permit udp any any capture session 1 count Supported Releases 10.2.0E or later remark Specifies an ACL entry description. Syntax remark [remark-number] [description] Parameters • remark-number - (Optional) Enter - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 413
IPv4, IPv6, or MAC. OS10(conf-ipv4-acl)# remark 10 Deny rest of the traffic OS10(conf-ipv4-acl)# remark 5 Permit traffic from XYZ Inc. Supported Releases 10.2.0E or later seq deny Assigns a sequence number to deny IP addresses while creating the filter. Syntax seq sequence-number deny [protocol - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 414
you know the filter's sequence number. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# seq 5 deny ipv6 any any capture session 1 count Supported Releases 10.2.0E or later seq deny (MAC) Assigns a sequence number to a deny filter in a MAC access list while creating the filter. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 415
:11:11 any cos 7 OS10(conf-mac-acl)# seq 20 deny 00:00:00:00:11:11 00:00:11:11:11:11 any vlan 2 Supported Releases 10.2.0E or later seq deny icmp Assigns a filter to deny internet control message protocol (ICMP) messages while creating the filter. Syntax seq sequence - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 416
the filter's sequence number. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# seq 10 deny icmp any any capture session 1 count Supported Releases 10.2.0E or later seq deny ip Assigns a sequence number to deny IP addresses while creating the filter. Syntax seq sequence-number deny - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 417
know the filter's sequence number. OS10(config)# ip access-list egress OS10(config-ipv4-acl)# seq 10 deny ip any any capture session 1 count Supported Releases 10.2.0E or later seq deny ipv6 Assigns a filter to deny IPv6 addresses while creating the filter. Syntax seq sequence-number deny ip - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 418
you know the filter's sequence number. OS10(config)# ip access-list egress OS10(conf-ipv4-acl)# seq 10 deny tcp any any capture session 1 count Supported Releases 10.2.0E or later seq deny tcp (IPv6) Assigns a filter to deny TCP packets while creating the filter. Syntax seq sequence-number deny - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 419
the filter's sequence number. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# seq 10 deny tcp any any capture session 1 count Supported Releases 10.2.0E or later seq deny udp Assigns a filter to deny UDP packets while creating the filter. Syntax Parameters seq sequence-number deny - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 420
the filter's sequence number. OS10(config)# ip access-list egress OS10(conf-ipv4-acl)# seq 10 deny udp any any capture session 1 count Supported Releases 10.2.0E or later seq deny udp (IPv6) Assigns a filter to deny UDP packets while creating the filter. Syntax Parameters seq sequence-number - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 421
the filter's sequence number. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# seq 10 deny udp any any capture session 1 count Supported Releases 10.2.0E or later seq permit Assigns a sequence number to permit packets while creating the filter. Syntax Parameters seq sequence-number - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 422
the filter's sequence number. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# seq 10 permit ipv6 any any capture session 1 count Supported Releases 10.2.0E or later seq permit (MAC) Assigns a sequence number to permit MAC addresses while creating a filter. Syntax Parameters seq - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 423
00:00:00:00:11:11 00:00:11:11:11:11 any vlan 2 Supported Releases 10.2.0E or later seq permit icmp Assigns a sequence number to allow ICMP OS10(conf-ipv4-acl)# seq 5 permit icmp any any capture session 1 count Supported Releases 10.2.0E or later seq permit icmp (IPv6) Assigns a sequence number - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 424
the filter's sequence number. OS10(config)# ipv6 access-list ipv6test OS10(conf-ipv6-acl)# seq 5 permit icmp any any capture session 1 count Supported Releases 10.2.0E or later seq permit ip Assigns a sequence number to allow packets while creating the filter. Syntax seq sequence-number permit - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 425
know the filter's sequence number. OS10(config)# ipv6 access-list egress OS10(conf-ipv6-acl)# seq 5 permit ipv6 any any capture session 1 count Supported Releases 10.2.0E or later seq permit tcp Assigns a sequence number to allow TCP packets while creating the filter. Syntax seq sequence-number - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 426
know the filter's sequence number. OS10(config)# ip access-list egress OS10(conf-ipv4-acl)# seq 5 permit tcp any any capture session 1 count Supported Releases 10.2.0E or later seq permit tcp (IPv6) Assigns a sequence number to allow TCP IPv6 packets while creating the filter. Syntax Parameters - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 427
you know the filter's sequence number. OS10(config)# ipv6 access-list egress OS10(conf-ipv6-acl)# seq 5 permit tcp any any capture session 1 count Supported Releases 10.2.0E or later seq permit udp Assigns a sequence number to allow UDP packets while creating the filter. Syntax Parameters seq - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 428
the filter's sequence number. OS10(config)# ip access-list egress OS10(conf-ipv4-acl)# seq 5 permit udp any any capture session 1 count Supported Releases 10.2.0E or later seq permit udp (IPv6) Assigns a sequence number to allow UDP IPv6 packets while creating a filter. Syntax Parameters seq - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 429
access-group ccc Ingress IPV6 access list aaa on ethernet 3/0 Ingress IPV6 access list aaa on ethernet 4/0 Egress IPV6 access list aaa on ethernet 4/0 Supported Releases 10.2.0E or later show access-lists Displays IP, MAC, or IPv6 access-list information. Syntax Parameters show {ip | mac | ipv6 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 430
interfaces : ethernet 3/0 ethernet 3/1 seq 10 permit any any Egress IPV6 access list ggg Active on interfaces : ethernet 3/0 seq 5 permit ipv6 11::/32 any count (0 packets) Supported Releases 10.2.0E or later 430 Access Control Lists - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 431
Command Mode EXEC Usage Information None Example OS10# show ip as-path-access-list ip as-path access-list hello permit 123 deny 35 Supported Releases 10.3.0E or later show ip community-list Displays the configured IP community lists in alphabetic order. Syntax Parameters Defaults Command Mode - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 432
24 seq 20 permit 3.4.4.5/32 Example (IPv6) OS10# show ipv6 prefix-list ipv6 prefix-list hello: seq 10 permit 1::1/64 seq 20 deny 2::2/64 Supported Releases 10.3.0E or later Route-map commands continue Configures the next sequence of the route map. Syntax Parameters Default Command Mode Usage - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 433
no version of this command deletes a match AS path filter. Example OS10(config)# route-map bgp OS10(conf-route-map)# match as-path pathtest1 Supported Releases 10.3.0E or later match community Configures a filter to match routes that have a certain COMMUNITY attribute in their BGP path. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 434
configured ROUTE-MAP The no version of this command deletes the match. OS10(conf-route-map)# match interface ethernet 1/1/1 OS10(conf-if-eth1/1/1)# Supported Releases 10.2.0E or later match ip address Configures a filter to match routes based on IP addresses specified in IP prefix lists. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 435
bgp OS10(conf-route-map)# match ip next-hop prefix-list test100 Supported Releases 10.3.0E or later match ipv6 address Configures a filter to (config)# route-map bgp OS10(conf-route-map)# match ipv6 address test100 Supported Releases 10.3.0E or later match ipv6 next-hop Configures a filter to - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 436
Not configured ROUTE-MAP The no version of this command deletes the match. OS10(config)# route-map bgp OS10(conf-route-map)# match origin egp Supported Releases 10.3.0E or later match route-type Configures a filter to match routes based on how the route is defined. Syntax match route-type - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 437
Command Mode ROUTE-MAP Usage Information The no version of this command deletes the match. Example OS10(conf-route-map)# match tag 656442 Supported Releases 10.2.0E or later route-map Enables a route-map statement and configures its action and sequence number. Syntax Parameters route-map map - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 438
The no version of this command deletes a BGP COMMUNITY attribute assignment. OS10(config)# route-map bgp OS10(conf-route-map)# set community none Supported Releases 10.3.0E or later set extcomm-list delete Configure a filter to remove the specified community list from the BGP route's EXTCOMMUNITY - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 439
command deletes the set clause from a route map. OS10(config)# route-map bgp OS10(conf-route-map)# set extcommunity rt 10.10.10.2:325 Supported Releases 10.3.0E or later set local-preference Sets the preference value for the AS path. Syntax set local-preference value Parameters value - Enter - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 440
no version of this command removes the filter. OS10(conf-route-map)# set metric 10 Example (Relative) OS10(conf-route-map)# set metric -25 Supported Releases 10.2.0E or later set metric-type Set the metric type for the a redistributed routel. Syntax set metric-type {type-1 | type-2 | external - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 441
the setting. OS10(conf-route-map)# set ip next-hop 10.10.10.2 Example (IPv6) OS10(conf-route-map)# set ipv6 next-hop 11AA:22CC::9 Supported Releases 10.2.0E or later set origin Set the origin of the advertised route. Syntax set origin {egp | igp | incomplete} Parameters • egp - Enter to add - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 442
Usage Information The no version of the command deletes the set clause from the route map. Example OS10(conf-route-map)# set weight 200 Supported Releases 10.2.0E or later show route-map Displays the current route map configurations. Syntax Parameters Defaults Command Mode show route-map [map - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 443
community hello metric 2 origin egp route-type external type-1 tag 10 Set clauses: metric-type type-1 origin igp tag 100 Supported Releases 10.3.0E or later Access Control Lists 443 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 444
jitter, bandwidth, and packet loss parameters on a network. OS10 devices examine each received packet and place the packet into different classes of service (CoS) by assigning a traffic class ID depending on the packet QoS parameters. QoS allows you to assign different behaviors to different traffic - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 445
in SYSTEM-QOS mode, or apply egress policy actions (queuing-type policy) to egress interfaces in SYSTEM-QOS mode. Configure quality of service Network traffic is processed based on classification and policies that are created and applied to the traffic. Configuring QoS is a three-step process - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 446
traffic. Create class-map C1 OS10(config)# class-map c1 OS10(conf-cmap-qos)# match cos 1 OS10(conf-cmap-qos)# do commit 446 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 447
c1 OS10(conf-pmap-c-qos)# set qos-group 1 OS10(conf-pmap-c-qos)# do commit Show policy-map OS10(conf-pmap-c-qos)# do show policy-map Service-policy(qos) input: p1 Class-map (qos): c1 set qos-group 1 Interface policy-map You can apply policy-maps directly to interfaces. 1 To attach a policy - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 448
policy-map gets priority. • Enter SYSTEM-QOS mode from CONFIGURATION mode. system qos • Configure an input service-policy, and create a name for the policy-map in SYSTEM-QOS mode. service-policy {[input type {qos}] | [output type {queuing}]} policy-map-name • Save the configuration. do commit Attach - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 449
class-trust OS10(conf-pmap-c-qos)# trust dot1p OS10(conf-pmap-c-qos)# do commit View policy-map OS10(conf-pmap-c-qos)# do show policy-map Service-policy(qos) input: policy-trust Class-map (qos): class-trust trust dot1p Queue selection OS10 does not honor DSCP values on ingress traffic by default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 450
class-trust OS10(conf-pmap-c-qos)# trust diffserv OS10(conf-pmap-c-qos)# do commit View policy-map OS10(conf-pmap-c-qos)# do show policy-map Service-policy (qos) input: policy-trust Class-map (qos): class-trust trust diffserv Strict priority queuing OS10 uses queues for egress QoS policy-types. You - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 451
use the match command to apply a match to place network traffic into specific traffic classes. You can classify the QoS traffic based on class of service (CoS) or 802.1 p (dot1p) values. You cannot have two match statements with the same match criterion. If you enter two match statements with the - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 452
bluedot1p OS10(conf-pmap-c-qos)# set qos-group 5 OS10(conf-pmap-c-qos)# do commit View policy-map OS10(conf-pmap-c-qos)# do show policy-map Service-policy(qos) input: red Class-map (qos): bluedot1p set qos-group 5 DSCP classification Classify traffic based on the DSCP value. The value of the QoS - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 453
bluedscp OS10(conf-pmap-c-qos)# set qos-group 7 OS10(conf-pmap-c-qos)# do commit View policy-map OS10(conf-pmap-c-qos)# do show policy-map Service-policy(qos) input: reddscp Class-map (qos): bluedscp set qos-group 7 MAC address classification Classify the QoS traffic based on the MAC access-list - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 454
OS10(conf-pmap-c-qos)# set qos-group 6 OS10(conf-pmap-c-qos)# do commit View policy-map OS10(conf-pmap-c-qos)# do show policy-map Service-policy(qos) input: redvlan Class-map (qos): bluevlan set qos-group 6 IP access-group classification With this classification, traffic that accesses the IP access - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 455
set qos-group 6 OS10(conf-pmap-c-qos)# do commit View policy-map OS10(conf-pmap-c-qos)# do show policy-map Service-policy(qos) input: ag2 Class-map (qos): accgrp set qos-group 6 Service-policy(application) input: policy-iscsi Service-policy(qos) input: redscp Class-map (qos): bluedscp set qos-group - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 456
marking To tag an incoming packet with 802.1p priorities, or modify incoming packets you can mark class of service (CoS). The set cos command is only supported under the ingress QoS policy type qos. 1 Create a policy-map of type qos and configure a name for the policy-map in CONFIGURATION mode - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 457
)# do commit View policy-map OS10(conf-pmap-c-qos)# do show policy-map Service-policy(qos) input: platinum Class-map (qos): diamond set cos 5 set group corresponds to data queues 0 to 7. The maximum number of data queues supported in OS10 are 8, and the maximum number of control traffic queues are - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 458
diamond OS10(conf-pmap-c-qos)# set qos-group 7 OS10(conf-pmap-c-qos)# do commit View QoS policy-map OS10(conf-pmap-c)# do show policy-map Service-policy(qos) input: platinum Class-map (qos): diamond set qos-group 7 Mark control-plane OS10(config)# class-map type control-plane copp OS10(conf-cmap - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 459
(match-any) Match: qos-group 5 View policy-map OS10(conf-pmap-c-que)# do show policy-map Service-policy (queuing) output: solar Class-map (queuing): lunar bandwidth percent 80 Service-policy rate-shaping Rate-shaping buffers traffic exceeding the specified rate until the buffer is exhausted. Traffic - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 460
pps 40 OS10(conf-pmap-c-que)# do commit View policy-map OS10(conf-pmap-c-que)# do show policy-map Service-policy(queuing) output: master Class-map (queuing): first shape min pps 10 max pps 40 Policy-based rate- packets for control plane and kbps (16 to 200000, default 200). 460 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 461
. To enforce rate-limiting or rate policing on control-plane traffic, create policy maps. You can use the control-plane command to attach the CoPP service policies directly to the control-plane. The default rate limits apply to 12 CPU queues and the protocols mapped to each CPU queue. The control - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 462
Create QoS policies (class maps and policy maps) for the desired CPU-bound queue. • Associate the QoS policy with a particular rate-limit. • Assign the QoS service policy to control plane queues. By default, the pir and cir values are in pps for control plane. CoPP for CPU queues converts the input - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 463
each queue. You can also use the show command output to verify the CoPP configuration. View CoPP configuration OS10# show qos control-plane Service-policy (input): pmap1 View CMAP1 configuration OS10# show class-map type control-plane cmap1 Class-map (control-plane): cmap1 (match-any) View CoPP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 464
weight value command to configure the weight for the WRED average queue size. The weight factor is set to zero by default. 464 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 465
-threshold 100 dropprobability 50 color yellow ecn weight 10 OS10(conf-pmap-c-que)# do commit View configured WRED profile OS10# show policy-map interface Service-policy (qos) input: p1 Class (qos): c1 set qos-group 1 Class (qos): c2 set qos-group 4 Class (qos): c3 set qos-group 7 View statistics - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 466
-map name-Enter the QoS policy-map name to display the details of a specific policy-map. View QoS control-plane OS10# show qos control plane Service-policy (Input): p1 466 Quality of - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 467
-map type qos c1 Class-map (qos): c1 (match-all) Match(not): ip-any dscp 10 View QoS policy-map OS10# show policy-map interface Service-policy (qos) input: p1 Class (qos): c1 set qos-group 1 Class (qos): c2 set qos-group 4 Class (qos): c3 set qos-group 7 Egress queue statistics - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 468
policy-map type is trust, where the class type must be qos. Example OS10(conf-pmap-qos)# class c1 Supported Releases 10.2.0E or later class-map Creates a QoS class-map which filters traffic to match packets to the one of the match criteria to be assigned to a class. 468 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 469
the port information. Default Command Mode Usage Information Example Not configured EXEC None OS10# clear interface ethernet 1/1/1 priority-flow-control Supported Releases 10.3.0E or later clear qos statistics Clears all QoS related statistics. Syntax Parameters Default Command Mode Usage - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 470
interface ethernet 1/1/7 OS10# clear qos statistics type queuing interface ethernet 1/1/2 Supported Releases 10.2.0E or later control-plane Enters Control-Plane mode. Syntax -map type control-plane p1 OS10(conf-pmap-control-plane)# Supported Releases 10.2.0E or later 470 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 471
version of this command returns the value to the default. OS10(conf-if-eth1/1/2)# flowcontrol transmit on Supported Releases 10.3.0E or later match Configures match criteria for the QoS policy. Syntax match {cos cos- the access-list ignores the permit and deny keywords. Quality of service 471 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 472
conf-cmap-qos)# match ip access-group name ag1 Supported Releases 10.2.0E or later match cos Matches a cost of service (CoS) value to L2 dot1p packets. Syntax first statement. The match-all option in a class-map does not support ip-any. Select either ip or IPv6 for the match-all criteria. - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 473
first statement. OS10(conf-cmap-qos)# match not ipv6 precedence 3 Supported Releases 10.2.0E or later match qos-group Configures a match criteria queues (0 to 7). Example OS10(conf-cmap-queuing)# match queue 1 Supported Releases 10.2.0E or later match vlan Configures a match criteria based on - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 474
the value to the default. Example OS10(conf-pmap-nqos-c)# mtu 2500 Supported Releases 10.3.0E or later pause Enables a pause based on buffer limits value to the default. Add the policy-map with pause to system-qos to service an input to enable pause on all ports, based on a per-port linklevel - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 475
-size 45 pause-threshold 30 resumethreshold 10 OS10(conf-cmap-nqos-c)# queue-limit thresh-mode static 150 Supported Releases 10.3.0E or later pfc-cos Configures priority flow-control for cost of service (CoS). Syntax pfc-cos cos-value Parameters cos-value - Enter a single, comma-delimited, or - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 476
values, the committed-rate cir values are taken as the pir values. Only the ingress QoS policy type supports this command. For control-plane policing, the rate values are in pps. OS10(conf-pmap-c-qos)# police cir The no version of this command deletes a policy-map. 476 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 477
)# policy-map type queuing p1 Supported Releases 10.2.0E or later priority QoS policy type supports this command. Example OS10(conf-pmap-que)# priority Supported Releases 10.2. OS10(conf-if-eth1/1/2)# priority-flow-control mode on Supported Releases 10.3.0E or later qos-group dot1p Configures - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 478
-tmap-dot1p-qos)# qos-group 5 dot1p 5 Supported Releases 10.3.0E or later qos-group dscp Configures dscp-qos)# qos-group 5 dscp 42 Supported Releases 10.3.0E or later queue-limit flow-control queue, this configuration is invalid • Only supported for POLICY-MAP-CLASS-MAP (pmap-c-queue) mode • - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 479
)# queue-limit queue-len 100 OS10(config-pmap-c-que)# queue-limit thresh-mode static 50 Supported Releases 10.3.0E or later queue qos-group Configures a dot1p traffic class to a queue. OS10(conf-tmap-tc-queue-qos)# queue 2 qos-group 5 Supported Releases 10.3.0E or later Quality of service 479 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 480
-threshold 10 maximum-threshold 100 drop-probability 50 color yellow ecn weight 10 Supported Releases 10.2.0E or later service-policy Configures the input and output service policies. Syntax service-policy {input | output} [type {qos | queuing}] policy-map-name Parameters • input - Enter to - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 481
Supported Releases 10.2.0E or later set cos Sets a cost of service (CoS) value to mark L2 802.1p (dot1p) corresponds to data queues 0 to 7. OS10(conf-pmap-c-qos)# set dscp 10 color yellow Supported Releases 10.2.0E or later set qos-group Configures marking for the QoS-group queues. Syntax - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 482
also enter the maximum rate in pps. OS10(conf-pmap-c-que)# shape min pps 10 max pps 40 Supported Releases 10.2.0E or later show class-map Displays configuration details of all existing class-maps. Syntax Parameters show • class-map-name - Displays the QoS class-map name. 482 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 483
EXEC Usage Information Monitors statistics for the control-plane and to troubleshoot CoPP. Example OS10# show control-plane info Queue Rate Limit 600 IPV6_OSPF IPV4_BGP IPV4_OSPF 10 600 IPV6_DHCP IPV4_DHCP SERVICEABILITY 11 300 OPEN_FLOW Supported Releases 10.2.0E or later show control- - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 484
Tx 0 0 0 1 0 0 2 0 0 3 300 200 4 0 0 5 0 0 6 0 0 7 0 0 Supported Releases 10.3.0E or later show qos interface Displays the QoS configuration applied to a specific interface. Syntax show Not configured Command Mode EXEC Usage Information None 484 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 485
control-plane. Syntax Parameters Default Command Mode Usage Information Example show qos control-plane None Not configured EXEC Monitors statistics for the control-plane and troubleshoots CoPP. OS10# show qos control-plane Service-policy (Input): p1 Supported Releases 10.2.0E or later Quality of - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 486
8 6 lossy 1664 dynamic 8 7 lossy 1664 dynamic 8 Supported Releases 10.3.0E or later show egress buffer-stats interface Displays the pckts bytes buffers buffers 0 0 0 0 0 1 0 0 0 0 2 0 0 0 0 3 0 0 0 0 4 0 0 0 0 5 0 0 0 0 486 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 487
- - 3 - - - - - 4 - - - - - 5 - - - - - 6 - - - - - 7 9360 static 12479488 - - OS10# Supported Releases 10.3.0E or later show ingress buffer-stats interface Displays [:subport] - (Optional) Enter the port information. Default Not configured Quality of service 487 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 488
Dropped 0 0 Green Drop 0 0 Yellow Drop 0 0 Red drop 0 0 Example (Queue) OS10# show queuing statistics interface ethernet 1/1/1 queue 3 Interface ethernet1/1/1 Queue 3 Description Packets Bytes Output 0 0 Dropped 0 0 Supported Releases 10.2.0E or later 488 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 489
Command Mode EXEC Usage Information View and verify system-level service-policy configuration information. Example OS10# show qos system Service-policy (Input) (qos) : policy1 Service-policy (Output)(queuing) : policy2 Supported Releases 10.2.0E or later show qos system buffers Displays - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 490
Priority to Traffic-Class Map : map1 Traffic-Class DOT1P Priority DOT1P Priority to Traffic-Class Map : dot1p-trustmap1 Traffic-Class DOT1P Priority 0 2 1 3 2 4 3 5 4 6 5 7 6 1 490 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 491
-map dscp new-dscp-map new-dscp-map qos-group Dscp Id 0 0-7 1 8-15 2 16-23 3 24-31 4 32-39 5 40-47 6 48-55 7 56-63 Supported Releases 10.3.0E or later system qos Enters SYSTEM-QOS mode to configure system-level - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 492
-CLASS-MAP The ingress QoS policy type and class-trust support this command. OS10(conf-pmap-c-qos)# trust dot1p Supported Releases 10.3.0E or later trust dot1p-map Creates user )# qos-group 4 dot1p 5 OS10(config-tmap-dot1p-map)# commit Supported Releases 10.3.0E or later 492 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 493
the default. Example OS10(config)# trust dscp-map dscp-trust1 Supported Releases 10.3.0E or later qos-map traffic-class Creates user- queue 3 qos-group 7 OS10(config-qos-map)# commit OS10(config-qos-map)# Supported Releases 10.3.0E or later trust-map Applies a dot1p or dscp traffic class to - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 494
command returns the value to the default. OS10(config)# interface ethernet 1/1/1 OS10(conf-if-eth1/1/1)# trust-map dscp dscp-trustmap1 OS10(conf-if-eth1/1/1)# commit Supported Releases 10.3.0E or later 494 Quality of service - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 495
role of spanning tree protocols (STPs) by allowing link aggregation group (LAG) terminations on two separate distribution or core switches and supporting a loop-free topology. • Allows a single device to use a LAG across two upstream devices • Provides a loop-free topology • Eliminates STP-blocked - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 496
to the attached devices. It is also associated with the configuration mode that you must use to assign VLT global parameters. • A VLT domain supports two node members. These peer devices appear as a single logical device to network access devices that connect to VLT ports through a port-channel - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 497
id mismatch command on each VLT peer. • In a VLT domain, VLT peers support connections to network devices that are connected to only one peer. • To start roles in the VLT domain are automatically assigned. 4 (Optional) Manually reconfigure the default VLT MAC address. 5 Configure VLT port-channels - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 498
RSTP configuration Only RSTP mode is supported on VLT ports. Before you configure VLT on peer switches, configure RSTP in the network. RSTP prevents loops during the VLT startup phase. • Enable RSTP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 499
Link Type: Point-to-Point BPDU Sent: 15, Received: 5 Create VLT domain A VLT domain requires an ID number. Configure the same VLT domain ID on both peers (see VLT domain). Use the no vlt-domain command to disable the VLT. 1 Configure a VLT domain and enter VLT-DOMAIN mode. Configure the same VLT - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 500
VLT unicast routing enables optimized routing in which packets destined for the L3 endpoint of the VLT peer are locally routed. VLT unicast routing is supported on IPv4 and IPv6. To enable VLT unicast routing, both VLT peers must be in L3 mode. The VLAN configuration must be symmetrical on both - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 501
Configure unicast routing - peer 2 OS10(config)# vlt-domain 1 OS10(conf-vlt-1)# peer-routing OS10(conf-vlt-1)# do commit View unicast routing - peer 2 OS10(conf-vlt-1)# do show running-configuration vlt ! vlt-domain 1 peer-routing discovery-interface ethernet1/1/1 ethernet1/1/2 VRRP Optimized - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 502
• View the current configuration of all VLT domains in EXEC mode. show running-configuration vlt View peer-routing information OS10# show vlt 1 Domain ID : 1 Unit ID : 1 Role : primary Version : 1.0 Local System MAC address : 90:b1:1c:f4:99:93 VLT MAC address : 90:b1:1c:f4:99:93 IP - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 503
VLT VLAN mismatch: VLT ID : 1 VLT Unit ID Mismatch VLAN List * 1 1 2 2 VLT ID : 2 VLT Unit ID Mismatch VLAN List * 1 1 2 2 View VLT port details * indicates the local peer OS10# show vlt 1 vlt-port-detail VLT port channel ID : 1 VLT Unit ID Port-Channel Status Configured - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 504
delay time to the default value. OS10(conf-vlt-1)# delay-restore 100 Supported Releases 10.3.0E or later discovery-interface Configures the interface to discover Command Mode VLT-DOMAIN Usage Information The VLT node discovery service auto-LAGs the discovery ports and creates VLTi interfaces. - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 505
designated path cost: 0 Number of transitions to forwarding state: 1 Edge port: No (default) Link Type: Point-to-Point BPDU Sent: 15, Received: 5 Supported Releases 10.3.0E or later show vlt Displays information on a VLT domain. Syntax show vlt id Parameter id - Enter a VLT domain ID (1 to - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 506
: up VLT Peer Unit ID System MAC Address Status IP Address Version 2 90:b1:1c:f4:bc:0a up fda5:74c8:b79e:1::2 1.0 Supported Releases 10.2.0E or later show vlt mismatch Displays mismatches in a VLT domain configuration. Syntax Parameters show vlt id mismatch [peer-routing | vlan - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 507
) OS10# show vlt 1 mismatch vlt-vlan VLT ID : 1 VLT Unit ID Mismatch VLAN List * 1 1 2 2 VLT ID : 2 VLT Unit ID Mismatch VLAN List * 1 1 2 2 Supported Releases 10.2.0E or later show vlt role Displays the VLT role of the local peer. Syntax show vlt id role Parameters id - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 508
occurs on VLT peers, the VLTi link between peers does not activate. The no version of this command disables VLT. OS10(config)# vlt-domain 1 Supported Releases 10.2.0E or later vlt-port-channel Configures the ID used to map interfaces on VLT peers into a single VLT port-channel. Syntax vlt- - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 509
all peers. The no version of this command disables the VLT MAC address configuration. OS10(conf-vlt-1)# vlt-mac 00:00:00:00:00:02 Supported Releases 10.2.0E or later vrrp mode active-active Enables the VRRP peers to locally forward L3 traffic in a VLAN interface. Syntax Parameters Default - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 510
9 Converged data center services OS10 supports converged data center services, including IEEE 802.1 data center bridging (DCB from a transmitting device. The 802.1p priority is also known as the class of service (CoS) or dot1p priority value. When PFC detects congestion of a dot1p traffic class, - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 511
supported for 802.1p priority traffic (dot1p 0 to 7). FCoE traffic traditionally uses dot1p priority 3 - iSCSI storage traffic uses dot1p priority 4. • Configure PFC for ingress traffic by using network-qos class and policy maps (see Quality of Service class-trust class instructs OS10 interfaces to - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 512
notes to change the default settings. Configuration steps: 1 Create PFC dot1p traffic classes. 2 Configure ingress buffers for PFC traffic. 3 Apply a service policy and enable PFC. 4 (Optional) Configure the PFC shared buffer for lossless traffic. Create PFC dot1p traffic classes 512 Converged - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 513
thresh-mode {static kilobytes | dynamic weight} 6 (Optional) Repeat Steps 2-4 to configure PFC on additional traffic classes. Apply service policy and enable PFC 1 Apply the PFC service policy on an ingress interface or interface range in INTERFACE mode. interface ethernet node/slot/port:[subport - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 514
-pmap-c-qos)# class-map class-trust OS10(config-pmap-c-qos)# trust dot1p OS10(config-pmap-c-qos)# exit OS10(config)# system qos OS10(config-sys-qos)# service-policy input type qos pclass1 OS10(config-sys-qos)# exit OS10(config)# class-map type network-qos cc1 OS10(config-cmap-nqos)# match qos-group - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 515
resume-threshold kilobytes] Parameters • buffer-size kilobytes - Enter the reserved (guaranteed) ingress-buffer size in kilobytes for PFC dot1p traffic (0 to 7787). Converged data center services 515 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 516
-map type network-qos pp1 OS10(conf-pmap-network-qos)# class cc1 OS10(conf-pmap-c-nqos)# pause buffer-size 30 pause-threshold 20 resumethreshold 10 Supported Releases 10.3.0E or later 516 Converged data center - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 517
pp1 OS10(conf-pmap-network-qos)# class cc1 OS10(conf-pmap-c-nqos)# pfc-cos 3 Supported Releases 10.3.0E or later pfc-shared-buffer-size Configures the amount of shared buffers -sys-qos)# pause-shared-buffer-size 1024 Supported Releases 10.3.0E or later Converged data center services 517 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 518
/1/1)# priority-flow-control mode on OS10(conf-if-eth1/1/1)# do commit Supported Releases 10.3.0E or later queue-limit Sets the static and dynamic OS10(conf-pmap-c-nqos)# queue-limit thresh-mode static 1024 Supported Releases 10.3.0E or later show interface priority-flow-control Displays - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 519
Tx 0 0 0 1 0 0 2 0 0 3 0 587236 4 0 0 5 0 0 6 0 0 7 0 0 Supported Releases 10.3.0E or later Enhanced transmission selection Enhanced transmission selection (ETS) provides customized bandwidth to rate-limit best-effort LAN traffic. Converged data center services 519 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 520
DSCP traffic classes to lossless queues. • Ingress trust policy - Configure a service policy to trust dot1p values in ingress traffic. • Egress queuing policy - from DCBX TLVs. • The CEE/IEEE2.5 versions of ETS TLVs are supported. ETS configurations are received in a TLV from a peer. Configure ETS - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 521
or separated by commas. Enter multiple queue qos-group entries, if necessary. qos-map traffic-class queue-map-name queue {0-7} qos-group {0-7} exit 3 Create a service policy for the class-trust class in CONFIGURATION mode. Enter POLICY-CLASS-MAP mode and specify that dot1p or DSCP values are trusted - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 522
OS10(config-sys-qos)# qos-map traffic-class tc-q-map1 OS10(config-sys-qos)# ets mode on OS10(config-sys-qos)# service-policy input type qos pclass1 OS10(config-sys-qos)# service-policy output type queuing p1 OS10(conf-pmap-c-qos)# do commit View ETS configuration OS10# show qos interface ethernet - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 523
command disables ETS. OS10(config-sys-qos)# ets mode on OS10(conf-if-eth1/1/1)# do commit Supported Releases 10.3.0E or later Data center bridging eXchange DCBX allows a switch to automatically discover and ) switches are part of a fibre channel storage network. Converged data center services 523 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 524
in topologies that support lossless operation for FCoE OS10 interfaces. You can manually reconfigure DCBX settings on both levels. • OS10 supports DCBX versions: CEE and port operates in a manual role by default. The support interface levels. You can manually reconfigure DCBX settings or disable - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 525
for iSCSI disabled Interface ethernet1/1/15 Port Role is Manual DCBX Operational Status is Enabled Is Configuration Source? ErPfI Local DCBX Status DCBX Operational Version is 0 DCBX Max Version Supported is 0 Sequence Number: 14 Acknowledgment Number: 5 Protocol State: center services 525 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 526
OS10# show lldp dcbx interface ethernet 1/1/15 ets detail Interface ethernet1/1/15 Max Supported PG is 8 Number of Traffic Classes is 8 Admin mode is on Admin 0% SP 6 0% SP 7 0% SP 15 0% SP Remote Willing Status is disabled Local Parameters : 526 Converged data center services - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 527
can re-enable it to ensure consistent operation of peers in a converged data center network. Example OS10(config)# dcbx enable OS10(config)# commit Supported Releases 10.3.0E or later dcbx tlv-select Configures the DCB TLVs advertised by a DCBX-enabled port. Syntax Parameters dcbx tlv-select - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 528
same command. OS10(conf-if-eth1/1/2)# dcbx tlv-select ets-conf pfc OS10(conf-if-eth1/1/2)# do commit Supported Releases 10.3.0E or later dcbx version Configures the DCBX version used on a port interface. Syntax Parameters dcbx eth1/1/1)# lldp tlv-select dcbxp 528 Converged data center services - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 529
Supported Releases for iSCSI disabled Interface ethernet1/1/15 Port Role is Manual DCBX Operational Status is Enabled Is Configuration Source? OS10# show lldp dcbx interface ethernet 1/1/15 ets Interface ethernet1/1/15 Max Supported PG is 8 Number of Traffic Classes is 8 Admin mode is on - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 530
pkts, 2 Output TLV pkts, 0 Error pkts 5 Input Appln Priority TLV pkts, 2 Output Appln Priority TLV pkts, 0 Error Appln Priority TLV Pkts 530 Converged data center services - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 531
to switch ports. To support storage arrays where auto-detection is not supported, manually configure iSCSI optimization. iSCSI optimization information and iSCSI session information. • A user-configured iSCSI class of service (CoS) profile is applied to all iSCSI traffic. Classifier rules are used - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 532
to a storage device is verified. You must manually enable an interface to support a storage device that is directly connected to 6 Configure the QoS policy applied to the ingress iSCSI flows. Apply the service policy to ingress interfaces in CONFIGURATION mode. (Optional) Reset the default CoS - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 533
config-pmap-c-app)# set cos 4 OS10 (config-pmap-c-app)# exit OS10(config-pmap-application)# exit OS10(config)# system qos OS10(config-sys-qos)# service-policy type application policy-iscsi OS10(config-sys-qos)# exit OS10(config)# iscsi session-monitoring enable OS10(config)# iscsi aging time 15 OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 534
this command disables the aging time. Example OS10(config)# iscsi aging time 30 Supported Releases 10.3.0E or later iscsi enable Enables iSCSI auto-detection of attached disables iSCSI auto-detection. OS10(config)# iscsi enable Supported Releases 10.3.0E or later 534 Converged data center - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 535
one bitmap value with this command is not supported. The default dot1p 4 value is advertised only OS10(config)# iscsi priority-bits 0x20 Supported Releases 10.3.0E or later iscsi profile storage arrays to be supported by iSCSI if they are profile-storage compellant Supported Releases 10.3.0E - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 536
monitoring. OS10(config)# iscsi session-monitoring enable Supported Releases 10.3.0E or later iscsi target from iSCSI monitoring. OS10(config)# iscsi target port 26,40 Supported Releases 10.3.0E or later lldp tlv-select dcbxp-appln Supported Releases 10.3.0E or later 536 Converged data center - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 537
15 Maximum number of connections is 256 Port IP Address 3260 860 3261 10.1.1.1 Supported Releases 10.3.0E or later show iscsi session Displays information about active iSCSI sessions. ISID:400001370000 Initiator Initiator Target Target Connection Converged data center services 537 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 538
Storage Device Name Auto Detected Status ethernet1/1/23 EQL-MEM true Supported Releases 10.3.0E or later Converged network DCB example A converged data storage traffic using: • Separate traffic classes for the different service needs of network applications. • PFC flow control to pause data - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 539
OS10(config-pmap-c-qos)# trust dot1p OS10(config-pmap-c-qos)# do commit OS10(config-pmap-c-qos)# end 3. PFC configuration (interface) Apply the service policies with dot1p trust and PFC configurations to an interface. OS10(config)# interface ethernet 1/1/53 OS10(conf-if-eth1/1/53)# no shutdown OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 540
-pmap-c-qos)# end 5. ETS configuration (interface and global) Apply the service policies with dot1p trust and ETS configurations to an interface or on all switch interfaces. Only one qos-map traffic-class map is supported on a switch. OS10(config)# interface ethernet 1/1/53 OS10(conf-if-eth1 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 541
switchport access vlan 1 no shutdown service-policy input type network-qos test service-policy input type qos pclass service-policy output type queuing pmap1 ets for iSCSI disabled Interface ethernet1/1/53 Port Role is Manual DCBX Operational Status is Enabled Is Configuration Source? FALSE - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 542
(conf-if-eth1/1/53)# do show lldp dcbx interface ethernet 1/1/53 ets detail Interface ethernet1/1/53 Max Supported PG is 8 Number of Traffic Classes is 8 Admin mode is on Admin Parameters Admin is enabled iSCSI traffic to 6 globally on the switch. By default, 542 Converged data center services - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 543
-pmap-c-app)# set cos 6 OS10(config-pmap-c-app)# exit OS10(config-pmap-application)# exit OS10(config)# system qos OS10(config-sys-qos)# service-policy type application policy-iscsi OS10(config-sys-qos)# exit OS10(config)# iscsi session-monitoring enable OS10(config)# iscsi priority-bits 0x40 OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 544
ethernet1/1/53 Port Role is Manual DCBX Operational Status is Enabled Is Status DCBX Operational Version is 0 DCBX Max Version Supported is 0 Sequence Number: 2 Acknowledgment Number: version ieee service-policy input type network-qos test service-policy input type qos pclass service-policy output - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 545
Interface ethernet1/1/53 Port Role is Manual DCBX Operational Status is Enabled Is Configuration Source? FALSE Local DCBX Compatibility mode is IEEEv2.5 Local transmitted 0 Total DCBX Frames received 0 Total DCBX Frame errors 0 Total DCBX Frames unrecognized 0 Converged data center services 545 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 546
. It is designed to provide traffic monitoring for high-speed networks with many switches and routers. • OS10 supports sFlow version 5 • sFlow collector is supported only on data ports • Maximum of two sFlow collectors • Does not support sFlow on SNMP, VLAN, VRF, and tunnel interfaces • Does not - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 547
sFlow maximum header size OS10(config)# sflow max-header-size 80 View sFlow information OS10# show sflow sFlow services are enabled Management Interface sFlow services are disabled Global default sampling rate: 32768 Global default counter polling interval: 20 Global default extended maximum header - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 548
sFlow polling interval OS10(config)# sflow polling-interval 200 View sFlow information OS10# show sflow sFlow services are enabled Management Interface sFlow services are disabled Global default sampling rate: 32768 Global default counter polling interval: 200 Global default extended maximum - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 549
View sFlow information The current release does not support the statistics for UDP packets dropped. • View sFlow configuration details and statistics in EXEC mode. OS10# show sflow sFlow services are enabled Management Interface sFlow services are disabled Global default sampling rate: 32768 Global - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 550
version of this command to remove the configured sFlow collector. Example OS10(conf)# sflow collector 10.1.1.1 agent-addr 2.2.2.2 6343 max-datagram-size 1500 vrf default Supported Releases 10.3.0E or later 550 sFlow - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 551
Use the no version of the command to reset the header size to the default value. OS10(conf)# sflow max-header-size 256 Supported Releases 10.3.0E or later sflow polling-interval Sets the sFlow polling interval. Syntax Parameter sflow polling-interval interval-value interval-value - Enter - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 552
or port-channel for the interface type. EXEC OS10 does not support statistics for UDP packets dropped and samples received from hardware. Example OS10# show sflow sFlow services are enabled Management Interface sFlow services are disabled Global default sampling rate: 32768 Global default counter - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 553
0 UDP packets dropped 34026 sFlow samples collected Example (portchannel) OS10# show sflow interface port-channel 1 port-channel1 sFlow is enabled on port-channel1 Samples rcvd from h/w: 0 Supported Releases 10.3.0E or later sFlow 553 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 554
OS10 Critical workloads and applications require constant availability. Dell EMC Networking offers tools to help you monitor and troubleshoot problems before they happen. Packet and flow capture Metrics measurement Analysis and reporting Alerting Logging Performance monitoring Mapping and - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 555
S 6.1 0.2 2:44.18 snmpd 30452 admin 20 0 22076 2524 2100 R 6.1 0.1 0:00.02 top 1 root 20 0 112100 5840 3032 S 0.0 0.1 0:12.32 systemd 2 root 20 0 0 0 0 S 0.0 0.0 0:00.00 kthreadd Troubleshoot OS10 555 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 556
captured packets to a file, use the -w parameter. To read the captured file output offline, you can use open source software packages such as wireshark. 556 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 557
a destination and wait for a response. If there is no response, the destination is not active. The ping command is useful during configuration if you have problems connecting to a hostname or IP address. Troubleshoot OS10 557 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 558
abort Tracing the route to 3ffe:501:ffff:100:201:e8ff:fe00:4c8b, 64 hops max, 60 byte packets Hops Hostname Probe1 Probe2 Probe3 558 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 559
Service-tag : 5XYK0Z1 Power Supplies PSU-ID AirFlow PPID 1 NORMAL CN0T9FNW2829852R026 2 NORMAL CN0T9FNW2829852R026 Fantrays FanTray-ID AirFlow PPID 1 NORMAL CN0MGDH82829852R039 2 NORMAL CN0MGDH82829852R039 3 NORMAL CN0MGDH82829852R039 Troubleshoot - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 560
location-led interface command to change the location LED for the specified interface. OS10# location-led interface ethernet 1/1/1 on OS10# location-led interface ethernet 1/1/1 off Supported Releases 10.3.0E or later 560 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 561
system ID. OS10# location-led system 1 on OS10# location-led system 1 off Supported Releases 10.3.0E or later ping Tests network connectivity to an IPv4 device. Syntax Parameters . • For a port-channel interface, enter port-channelchannel-id; for example, port-channel1. Troubleshoot OS10 561 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 562
to fill out the packet you send to diagnose data-related problems in the network (for example, -p ff fills the sent packet up to 1500 bytes in decimal or hex) to set quality of service (QoS)-related bits. • -s packetsize - (Optional) Enter the Supported Releases 10.2.0E or later 562 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 563
pad bytes to fill out the packet you send to diagnose data-related problems in the network (for example, -p ff fills the sent packet with all datagrams (up to 1500 bytes in decimal or hex) to set quality of service (QoS)-related bits. • -s packetsize - (Optional) Enter the number Troubleshoot OS10 563 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 564
loss, time 3005ms rtt min/avg/max/mdev = 2.078/2.194/2.379/0.127 ms Supported Releases 10.2.0E or later show boot Displays boot partition-related information. Syntax Parameters Default Current system image information detail: Type: Node-id 1 Boot Type: Flash Boot 564 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 565
03T23:11:14Z A 10.2.0E 2016-10-03T23:11:14Z active[B] Supported Releases 10.2.0E or later show diag Displays diagnostic information for port adapters .1 Ethernet controller: Broadcom Corporation Device b340 (rev 01) Supported Releases 10.2.0E or later show environment Displays information about - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 566
temp sensor 21 1 3 Ambient temp sensor 24 1 4 NPU temp sensor 43 Supported Releases 10.2.0E or later show hash-algorithm Displays hash algorithm information. Syntax Parameters Default : 10.2.9999E Unit Type Part Number Rev Piece Part ID 566 Troubleshoot OS10 Svc Tag Exprs Svc C - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 567
410 1 S6000-ON-FANTRAY-3 0MGDH8 A00 CN-0MGDH8-28298-52R-0392 AEIOU## 226 457 410 Supported Releases 10.2.0E or later show processes View process CPU utilization information. Syntax Parameters show processes node PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND Troubleshoot OS10 567 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 568
1019 root OS10# Supported Releases 10.3.0E or later 20 0 1829416 256080 73508 S 6.6 6.4 1212:36 base_nas show system Displays system (node-id) OS10# show system node-id 1 fanout-configured Interface Breakout capable Breakout state Eth 1/1/1 Yes BREAKOUT_1x1 568 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 569
-- FanTray Status AirFlow Fan Speed(rpm) Status 1 up NORMAL 1 6710 up 2 7136 up 2 up NORMAL 1 6767 up 2 7155 up 3 up NORMAL 1 6785 up 2 7040 up Supported Releases 10.2.0E or later Troubleshoot OS10 569 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 570
out simultaneously to accelerate traceroute (default 16). • -t tos - (Optional) For IPv4, enter the Type of Service (TOS) and Precedence values to use. 16 sets a low delay; 8 sets a high throughput. • -UL GigabitEthernet3-3.GW3.SCL2.ALTER.NET (152.179.99.173) 4.428 ms 2.593 570 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 571
(20::1), 30 hops max, 80 byte packets 1 20::1 (20::1) 2.622 ms 2.649 ms 2.964 ms Supported Releases 10.2.0E or later Password recovery You may need to recovery your lost password. 1 Connect to the serial installed operating system and requires a long time to erase storage. Troubleshoot OS10 571 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 572
: /dev/mmcblk0 (7832MB) Percent complete: 100% SupportAssist By default, SupportAssist is enabled. SupportAssist sends troubleshooting data securely to Dell Technical Support. SupportAssist does not support automated email notification at the time of hardware fault alert, automatic case creation - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 573
or email address) which would be used to provide technical support for your Dell products and services. Dell may use the information for providing recommendations to improve information is optional, it is used by Dell Technical Support to identify which company owns the device. Troubleshoot OS10 573 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 574
person configurations are optional for the SupportAssist service. 1 (Optional) Enter the contact name in SUPPORT-ASSIST mode. contact-person first firstname activities in EXEC mode. support-assist-activity {full-transfer} schedule {hourly | daily | weekly | monthly | yearly} 574 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 575
license agreement in EXEC mode. show support-assist eula View SupportAssist status OS10# show support-assist status EULA : Accepted Service : Enabled Contact-Company : DellCMLCAEOS10 enabled event-notification enabled full-transfer enabled Scheduled Activity List : Troubleshoot OS10 575 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 576
) which would be used to provide technical support for your Dell products and services. Dell may use the information for providing support information. Default Command Mode Usage Information Enabled SUPPORT-ASSIST Use the no version of this command to remove the configuration. 576 Troubleshoot - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 577
(conf-support-assist-Eureka)# contact-person first "John James" last Smith Supported Releases 10.2.0E or later email-address Configures the email address for the contact name. Syntax email-address address Parameters address - Enter the email address for the contact name. Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 578
eula-consent {support-assist} {accept | reject} • support-assist - Enter to accept or reject the EULA for the service. • accept SUPPORT-ASSIST The no version of this command removes the configuration. OS10(conf-support-assist-Eureka-JohnJamesSmith)# preferred-method email 578 Troubleshoot - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 579
Supported Releases 10.2.0E or later show support-assist eula Displays the EULA for SupportAssist. Syntax Parameters Default Command Mode Usage Information show support-assist eula None None EXEC Use the eula-consent support-assist accept command to accept the license agreement. Troubleshoot - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 580
and/or email address) which would be used to provide technical support for your Dell, Inc. products and services. Dell, Inc. may use the information for providing recommendations to : Michael Dale Email : [email protected] Primary phone : 555-123-4567 Alternate phone : 580 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 581
20:51:51 full-transfer success Sep 12,2016 20:30:28 Sep 12,2016 20:30:52 Supported Releases 10.2.0E or later street-address Configures the street address information for the company. Syntax street to schedule the daily task (0 to 59). • weekly - Schedule a weekly task: Troubleshoot OS10 581 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 582
collects Linux system configuration and diagnostics information, as well as show command output to send to Dell Technical Support. To send Dell Technical Support troubleshooting details about the Linux system configuration and OS10 diagnostics, generate an sosreport tar file. 1 Generate the tar file - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 583
dir supportbundle and copy supportbundle:// sosreport-OS10-file-number.tar.gz tftp://server-address/path commands. Example OS10# generate support-bundle Example (Enable Options) OS10# generate support-bundle enable-all-plugin-options Supported Releases 10.2.0E or later Troubleshoot OS10 583 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 584
A minor error or non-critical condition occurred that, if left unchecked, might cause system service interruption or performance degradation. A minor alarm requires monitoring or maintenance. • Informational - An no version of any logging command to disable system logging. 584 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 585
file OS10# show logging log-file Jun 1 05:01:46 %Node.1-Unit.1:PRI:OS10 %log-notice:ETL_SERVICE_UP: ETL service is up Jun 1 05:02:06 %Node.1-Unit.1:PRI:OS10 %log-notice:EQM_UNIT_DETECTED: Unit pres ent:Unit 1# %log-notice:IFM_ASTATE_UP: Interface adm in state up.:vlan1 --More-- Troubleshoot OS10 585 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 586
of all links. If you enable monitoring, the utilization calculation performs when the utilization of the link-bundle (not a link within a bundle) exceeds 60%. 586 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 587
index command to view a list of alarm IDs. Example OS10# alarm clear 200 Supported Releases 10.2.0E or later show alarms Displays all current active system alarms. Syntax show Sep 7 18:36:11 Node.1-Unit.1 Sep 7 18:36:11 Node.1-Unit.1 Supported Releases 10.2.0E or later Troubleshoot OS10 587 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 588
: Raise-time: Sep 20 0:16:52 Clear-time: New: true State: raised Supported Releases 10.2.0E or later show alarms history Displays the history of cleared alarms. Syntax configured EXEC None OS10# show alarms history Index Severity Name Raise-time Source 588 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 589
Raise-time: Sep 20 0:16:52 Clear-time: New: true State: raised Supported Releases 10.2.0E or later show alarms severity Displays all active alarms using the severity • critical - Critical alarm severity. • major - Major alarm severity. • minor - Minor alarm severity. Troubleshoot OS10 589 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 590
Description: Raise-time: Sep 20 0:1:5 Clear-time: New: true State: raised Supported Releases 10.2.0E or later show alarms summary Displays the summary of alarm information. -alarm Summary Total-count: 6 Critical-count: 0 Major-count: 2 Minor-count: 2 590 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 591
clear logging log-file Proceed to clear the log file [confirm yes/no(default)]: Supported Releases 10.2.0E or later logging console Disables, enables, or configures the minimum to debug messages. Default Command Mode Usage Information Log-notice CONFIGURATION None Troubleshoot OS10 591 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 592
The no version of this command disables all logging. OS10(config)# logging enable Supported Releases 10.2.0E or later logging log-file Disables, enables, or sets the Set to debug messages. Default Command Mode Usage Information Log-notice CONFIGURATION None 592 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 593
-file enable Example (Severity) OS10(config)# logging log-file severity log-notice Supported Releases 10.2.0E or later logging monitor Set the minimum severity level for logging - Immediate action is needed. • log-crit - Critical conditions. • log-err - Error conditions. Troubleshoot OS10 593 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 594
severity log-info OS10(config)# logging server fda8:6c3:ce53:a890::2 OS10(config)# commit Supported Releases 10.2.0E or later show logging Displays system logging messages by log-file, process-names dn_l3_core_serv dn_policy dn_qos dn_switch_res_m dn_ospfv3 dn_lacp dn_i3 594 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 595
dn_supportassis --More-Supported Releases 10.2.0E or later show trace Displays trace messages. Syntax Parameters Default Command Mode (23 59319) May 23 17:10:08 OS10 base_nas: [NETLINK:NHEVENT]:ds_api_linux_neigh.c:nl_to_nei --More-- Supported Releases 10.2.0E or later Troubleshoot OS10 595 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 596
shell commands to display system state and variables, or as instructed by Dell Support. OS10 login: linuxadmin Password: linuxadmin >> only for first- and so on. • Security contains information about how to add users, troubleshoot RADIUS, how to view current DHCP information, and so on. • Layer - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 597
contains information about quality of service including classification and marking, congestion the Getting Started Guide shipped with your device or the platform-specific Installation Guide on the Dell Support page (see dell.com/ support). Hardware What of the device Troubleshoot OS10 597 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 598
? Use the username commands to add new users. Use the show users command to view a list of current users. How do I view RADIUS transactions to troubleshoot problems? Use the debug radius command. How do I view the current DHCP binding information? Use the show ip dhcp binding command. Layer 2 How do - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 599
command to view the currently running software version. How can I troubleshoot SNMP operation? Use the show ip traffic command to view IP information? Use the show access-group and show access-list commands. Quality of service What are the QoS error messages? Flow control error messages: • Error: - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 600
else reconfigure the pause buffers Monitoring How can I check if SupportAssist is enabled? Use the show support-assist status command to view current configuration information. How can I view a list of alarms? Use logging command to view messages by log-file or process name. 600 Troubleshoot OS10 - Dell PowerSwitch S6000 ON | OS10 Enterprise Edition User Guide Release 10.3.0E - Page 601
tag or express service code, pull out the luggage tag on the chassis or enter the show chassis command from the CLI. • To receive additional kinds of technical support, click Contact Us, then click Technical Support. To access system documentation, see www.dell.com/manuals/. To search for drivers
OS10 Enterprise Edition User Guide
Release 10.3.0E