Dell PowerVault 51F Dell PowerVault 51F 8-Port Fibre Channel Switch User's
Dell PowerVault 51F Manual
View all Dell PowerVault 51F manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell PowerVault 51F manual content summary:
- Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 1
™ - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 2
in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden. Trademarks used in this text: Dell, the DELL logo, and PowerVault are trademarks and DellWare is a service mark of Dell Computer Corporation; Intel and i960 are registered trademarks of - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 3
own personal safety and to help protect your computer or storage system from potential damage. Throughout this guide, blocks of text may be accompanied by an icon and printed in bold type or in italic of your computer system. Observe the following caution and warnings while servicing this system: v - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 4
. Observe the following general precautions for using and working with your system: Observe and follow service markings. Do not service any Dell product except as explained in your Dell system documentation. Opening or removing covers that are marked with the triangular symbol with a lightning - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 5
your troubleshooting guide or contact a Dell-authorized service provider. power source required, consult your Dell service provider or local power company. To help avoid damaging your system components, be sure the voltage selection switch (if provided) on the power supply is set to match the power - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 6
who are qualified to service your computer or storage system equipment and trained to deal with products capable of producing hazardous energy levels. When connecting or disconnecting power to hot-pluggable power supplies, if offered with your Dell product, observe the following guidelines - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 7
in a Dell rack by trained service technicians. If you install the kit in any other rack, be sure that the rack meets the specifications of a Dell rack. Do into the rack. Do not overload the AC supply branch circuit that provides power to the rack. The total rack load should not exceed 80 - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 8
to components in the rack. Do not step on or stand on any system/component when servicing other systems/components in a rack. Observe the following guidelines when working with options: Do not connect or use a modem or telephone during a lightning storm. There may be a risk of electrical shock from - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 9
components. 3. Disconnect your computer and devices from their power sources. Also, disconnect any telephone or telecommunication lines from them evenly aligned to avoid bending any connector pins. Also, before you connect a cable, make sure that both connectors are correctly oriented and aligned - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 10
in front of you as you work. Special shelves are available (from Dell and other sources) to help you correctly position your keyboard. Set the on the monitor screen. Use a chair that provides good lower back support. Keep your forearms horizontal with your wrists in a neutral, comfortable position - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 11
wrists relaxed and flat monitor screen at or below eye level arms at desk level monitor and keyboard positioned directly in front of user feet flat on the floor xiii - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 12
xiv - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 13
overview of the switch including features, system components, and interface cards. Chapter 2, "Technical Specifications," is intended primarily Guide, the following documentation is included with your switch: The Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 14
technical changes to your switch or advanced technical reference material intended for experienced users or technicians. The following list defines (where appropriate) and illustrates typographical conventions used as visual cues for specific font are part of an instruction and intended to be typed. - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 15
possible parameters. Command lines are presented in the Courier New font. Example: del c:\myfile.doc Screen text is a message or text that you are instructed to type as part of a command (referred to as a command line). Screen text is presented in the Courier New font. Example: The following message - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 16
xviii - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 17
1-3 Serviceability 1-3 System Components 1-3 Switching Function 1-3 Universal Ports 1-4 Embedded Port 1-4 System Firmware 1-4 SWL Fiber-Optic GBIC Module 1-4 LWL Fiber-Optic GBIC Module 1-5 Copper GBIC Module 1-5 Hot-Pluggable Power Supplies 1-5 Fabric Management Specifications - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 18
Coverage During Year One B-4 Coverage During Years Two and Three B-4 General Provisions B-5 "Total Satisfaction" Return Policy (U.S. and Canada Only B-5 Year 2000 Statement of Compliance for Dell-Branded Hardware Products B-6 Previous Products B-7 Software B-7 Additional Information B-7 xx - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 19
A-4. Switch View of PowerVault 51F 1-1 VCCI Class A ITE Regulatory Mark A-5 VCCI Class B ITE Regulatory Mark A-6 MOC Class A Regulatory Mark A-7 MOC Class B Regulatory Mark A-7 Table 2-1. Table 2-2. Table 2-3. Dell PowerVault 51F Switch Specifications 2-1 Fabric Management Specifications - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 20
xxii - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 21
a Fibre Channel fabric. Figure 1-1 shows the switch view of a PowerVault 51F. This chapter discusses: PowerVault 51F switch features Performance Manageability Reliability Serviceability System components Switching function Embedded port System firmware Universal ports Short-wave laser (SWL) fiber - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 22
is specified for Class 2, Class 3, and Class F frames when the output port is free. You can manage the PowerVault 51F switch locally using the RS232 port. You can also manage the switch remotely via Telnet or Dell OpenManage™ products. 1-2 Dell PowerVault 51F 8-Port Fibre Channel Switch User's Guide - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 23
monitoring Low component count Optional redundant power supply Redundant fans The PowerVault 51F switch has the following features, enhancing serviceability: Simple enclosure Loopback test modes for service Hot-pluggable fans and power supply No jumpers or switch settings Components are enclosed in - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 24
and interfaces described in "PowerVault 51F Commands" of the Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide for switch monitoring, control, and management. The SWL fiber-optic GBIC module is based on short wavelength CD lasers supporting 1.0625-Gbps link - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 25
frequencies. The power supply has a modular design that plugs directly into the enclosure through the front panel, attaching to an internal connector. The PowerVault 51F also supports a second redundant hot-pluggable power supply. The power supply has an integrated on and off switch, input filter - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 26
1-6 Dell PowerVault 51F 8-Port Fibre Channel Switch User's Guide - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 27
Table 2-1 shows the Dell PowerVault 51F switch general specifications. ANSI Fibre Channel protocol Fabric initialization System architecture System processor Number of Fibre Channel ports Fibre Channel port speed Modes of operation Aggregate switch I/O bandwidth Frame buffers Fabric latency Data - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 28
PowerVault 51F switch are shown in Table 2-3. Temperature (operating) Temperature (non-operating) Operating humidity Nonoperating humidity 0° C to 35° C -35° C to 65° C 5% to 85% noncondensing at 40° C 95% RH noncondensing at 40° C 2-2 Dell PowerVault 51F 8-Port Fibre Channel Switch User's Guide - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 29
octave/minute The PowerVault 51F Switch may be configured for power ratings are required: Input voltage: 100 to 240 volts AC (VAC) Total input power: 110 watts (W) (with one or two power supplies) Input line frequency: 50 to 60 hertz (Hz) Local country power cable supplied. Technical Specifications - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 30
2-4 Dell PowerVault 51F 8-Port Fibre Channel Switch User's Guide - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 31
power or signal leads, that endangers the functioning of a radio navigation or other safety service or seriously degrades, obstructs, or repeatedly interrupts a licensed radio communications service. Radio communications services consult a Technical Support representative of Dell Computer Corporation - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 32
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio A-2 Dell PowerVault 51F 8-Port Fibre Channel Switch User's Guide - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 33
the manufacturer's instruction manual, may cause connected. Consult the dealer or an experienced radio/television technician for help. The following information is provided on the device or devices covered in this document in compliance with FCC regulations: Model number: 51F Company name: Dell - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 34
indic- ative that this Dell system meets the following technical standards: EN 55022 - to replace it, refer to your system documentation for instructions. Do not dispose of the battery along with household specific card or component. A-4 Dell PowerVault 51F 8-Port Fibre Channel Switch User's Guide - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 35
specification label. The following applies to devices in Class A of EN 55022 (radius of protection up to 30 meters). The user of the device is obliged to take all steps necessary to remove sources of interference to telecommunication or other devices. - Most Dell into or connected to the system - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 36
equipment according to the instruction manual. To determine which classification (Class A or B) applies to your computer system (or other Dell digital device), examine for business purposes. Class B devices are for nonbusiness purposes. A-6 Dell PowerVault 51F 8-Port Fibre Channel Switch User's Guide - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 37
-circuit protection device in the form of a fuse with a nominal value no larger than 16 amperes (A). To completely switch off the equipment, the power supply cable must be removed from the power supply socket, which should be located near the equipment and easily accessible. Regulatory Notices A-7 - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 38
A protection mark "B" confirms that the equipment is in compliance with the protection usage requirements of standards PN-93/T-42107 and PN-89/E-06251. -- -- - A-8 Dell PowerVault 51F 8-Port Fibre Channel Switch User's Guide - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 39
with the requirements of the official Mexican standards (NOM): Exporter: Importer: Ship to: Supply voltage: Frequency: Input current rating: Dell Computer Corporation One Dell Way Round Rock, TX 78682 Dell Computer de México, S.A. de C.V. Rio Lerma No. 302 - 4° Piso Col. Cuauhtemoc 16500 México - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 40
No. 302 - 4° Piso Col. Cuauhtemoc 16500 México, D.F. Dell Computer de México, S.A. de C.V. al Cuidado de Kuehne & Nagel de México S. de R.I. Avenida Soles No. 55 Col. Peñon de los Baños 15520 México, D.F. 100-240 VAC 47-63 Hz 1.5 A A-10 Dell PowerVault 51F 8-Port Fibre Channel Switch User's Guide - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 41
. To request warranty service, you must call Dell's Customer Technical Support within the warranty period. Refer to the chapter titled "Getting Help" in your system's troubleshooting documentation or, for some systems, the section titled "Contacting Dell" in your system's online guide to find the - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 42
hardware failure to Dell's Customer Technical Support in advance to obtain Dell's concurrence that a part should be replaced and to have Dell ship the replacement part. Dell will ship parts OR IMPLIED, WILL APPLY AFTER SUCH PERIOD. B-2 Dell PowerVault 51F 8-Port Fibre Channel Switch User's Guide - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 43
including accident, abuse, misuse, problems with electrical power, servicing not authorized by Dell, usage not in accordance with product instructions, failure to perform required preventive maintenance, and problems caused by use of parts and components not supplied by Dell. This warranty does not - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 44
be in accordance with Dell's Exchange Policy in effect on the date of the exchange. You accept full responsibility for your software and data. Dell is not required to advise or remind you of appropriate backup and other procedures. B-4 Dell PowerVault 51F 8-Port Fibre Channel Switch User's Guide - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 45
AND REPLACEMENT AS SET FORTH IN THIS WARRANTY STATEMENT. THESE WARRANTIES GIVE YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS, WHICH VARY FROM STATE TO STATE (OR JURISDICTION TO JURISDICTION). DELL DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES SET FORTH IN THIS WARRANTY STATEMENT OR - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 46
and all of the manuals, diskette(s), CD(s), power cables, and other items specific operating environments may vary depending on other factors including, but not limited to, other hardware, operating systems, and applications software. B-6 Dell PowerVault 51F 8-Port Fibre Channel Switch User's Guide - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 47
Patch, a software utility designed to assist customers in managing the year 2000 rollover. Dell specifically excludes all non-Dell-developed software from this compliance statement. All software run on Dell-branded hardware products should be independently verified by customers to be year 2000 - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 48
B-8 Dell PowerVault 51F 8-Port Fibre Channel Switch User's Guide - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 49
that supports multicast group management. American National Standards Institute. Class-3 service provides a connectionless service without to a network resulting from the interconnection of switches and devices comprised of high-speed fiber connections. A fabric is an active, intelligent, - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 50
specific function in the fabric. R_A_TOV (Resource Allocation Time Out Value) used to time out operations that depend on the maximum possible time that a frame could be delayed in a fabric A WWN uniquely identifies a switch on local and global networks. 2 Dell PowerVault 51F 8-Port Fibre Channel - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 51
rack-mount, 2-3 table top, 2-3 electrostatic discharge. See ESD embedded port, 1-4 ESD, xi fabric, 1-1 fans, 1-3 features, 1-2 fiber-optic GBIC module, 1-4, 1-5 Fibre Channel protocol, 2-1 firmware, 1-4 GBIC module, 1-4, 1-5 introduction, 1-1 laser, 1-4, 1-5, 2-2 LWL GBIC module, 1-5 Index 1 - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 52
, A-2 repair period, 2-4 return policy, B-5 warnings, v warranty information, xv, B-1, B-3 safety instructions for preventing ESD, xi health considerations, xii Simple Network Management Protocol. See SNMP year 2000 compliance, B-6 2 Dell PowerVault 51F 8-Port Fibre Channel Switch User's Guide - Dell PowerVault 51F | Dell PowerVault 51F 8-Port Fibre Channel Switch User's
- Page 53
™ ™
™
±±±²³´µµ²¶·¸
±²³³´µ¶·¸²¹º»¼³½´
±²³´±
¾¿¶·¹½µÀÁ¹²µÃÄ»ÅŲ³µÆ¸Á½ÇÄ
±²³´µ²¶·±¸¹³