Dell™ PowerVault™ DL2200 Systems Hardware Owner's Manual Regulatory Model E13S Series Regulatory Type E13S001 - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 2
CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: A WARNING indicates a potential for either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 3
Back-Panel Features and Indicators 15 Guidelines for Connecting Optional External Devices 17 NIC Indicator Codes 17 Power Indicator Codes 18 Diagnostic Lights 19 System Messages 21 Warning Messages 36 Diagnostics Messages 36 Alert Messages 36 Other Information You May Need 37 2 Using the - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 4
Screen 43 Boot Settings Screen 45 Integrated Devices Screen 45 PCI IRQ Assignments Screen 46 Serial Communication Screen 47 Power Management Screen 48 System Security Screen 48 Exit Screen 50 Entering the UEFI Boot Manager 51 Using the UEFI Boot Manager Navigation Keys 51 UEFI Boot Manager - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 5
61 Front Bezel (Optional 63 Removing the Front Bezel 63 Installing the Front Bezel 64 Opening and Closing the System 64 Opening the System 64 Closing the System 65 Cooling Shroud 66 Removing the Cooling Shroud 66 Installing the Cooling Shroud 67 Hard Drives 67 Removing a Hard-Drive Blank - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 6
77 Removing a Power Supply 78 Installing a Power Supply 79 Removing the Power Supply Blank 80 Installing the Power Supply Blank 80 System Memory 80 General Memory Module Installation Guidelines 81 Mode-Specific Guidelines 82 Installing Memory Modules 85 Removing Memory Modules 87 Expansion - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 7
Installing a VFlash Media Card 103 Removing a VFlash Media Card 103 Processors 103 Removing a Processor 103 Installing a Processor 107 System Battery 108 Replacing the System Battery 108 RAID Battery 111 Removing the RAID Battery 111 Installing the RAID Battery 112 Control Panel Assembly- - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 8
Troubleshooting a NIC 131 Troubleshooting a Wet System 132 Troubleshooting a Damaged System 134 Troubleshooting the System Battery 134 Troubleshooting Power Supplies 135 Troubleshooting System Cooling Problems 136 Troubleshooting a Fan 136 Troubleshooting System Memory 137 Troubleshooting - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 9
System Diagnostics Features 147 When to Use the Embedded System Diagnostics . . . . 148 Running the Embedded System Diagnostics 148 Embedded System Information and Results 150 6 Jumpers and Connectors 151 System Board Jumpers 151 System Board Connectors 152 Disabling a Forgotten Password 154 - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 10
10 Contents - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 11
you to access utilities such as embedded system diagnostics. For information on Lifecycle Controller or any of the Lifecycle Controller software components, see the Lifecycle Controller documentation on the Dell Support website at support.dell.com/manuals. Enters the BIOS Boot Manager or - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 12
an image, depending on the amount of memory installed in the system. NOTE: On ACPI-compliant operating systems, turning off the system using the power button causes the system to perform a graceful shutdown before power to the system is turned off. NOTE: To force an ungraceful shutdown, press and - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 13
troubleshoot software and device driver errors when using certain operating systems. This button can be pressed using the end of a paper clip. Use this button only if directed to do so by qualified support personnel or by the operating system system information including the Express Service tag, embedded - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 14
drive/preparing for removal Drive ready for insertion or removal NOTE: The drive status indicator remains off until all hard drives are initialized after system power is applied. Drives are not ready for insertion or removal during this time. Drive predicted failure Drive failed 14 About Your - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 15
aborted Back-Panel Features and Indicators Figure 1-3 shows the controls, indicators, and connectors located on the back panel of the system. Figure 1-3. Back-Panel Features and Indicators ST 1 1 2 Gb 1 2 3 Gb 2 12 3 4 56 Item Indicator, Button, or Icon Connector 1 Serial connector 2 Video - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 16
during normal system operation. Both the systems management software and the identification buttons located on the front and back of the system can cause the indicator to blink blue to identify a particular system. Lights amber when the system needs attention due to a problem. The identification - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 17
otherwise). • Ensure that the appropriate driver for the attached device has been installed on the system. • If necessary, use the System Setup program to enable ports on your system. See "Using the System Setup Program and UEFI Boot Manager" on page 39. NIC Indicator Codes Figure 1-4. NIC - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 18
is connected to the power supply, and that the power supply is operational. When the system is on, it also indicates that the power supply is providing DC power to the system. • Amber - Indicates a problem with the power supply. • Alternating green and amber - When hot-adding a power supply, this - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 19
See "Getting Help" on page 157. Possible processor failure. See "Troubleshooting Processors" on page 144. Memory failure. See "Troubleshooting System Memory" on page 137. Possible expansion card See "Troubleshooting Expansion failure. Cards" on page 142. Possible video failure. See "Getting - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 20
page 157. Possible system resource See "Contacting Dell" on configuration error. page 157. Other failure. Ensure that the hard drives are properly connected. See "Troubleshooting a Hard Drive" on page 139 for the appropriate drive installed in your system. If the problem persists, see "Getting - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 21
in a configuration that supports Advanced ECC Memory Mode. Check other system messages for additional information for possible causes. For memory configuration information, see "General Memory Module Installation Guidelines" on page 81. If the problem persists, see "Troubleshooting System Memory" on - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 22
in a configuration that supports node interleaving. Check other system messages for additional information for possible causes. For memory configuration information, see "General Memory Module Installation Guidelines" on page 81. If the problem persists, see "Troubleshooting System Memory" on page - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 23
or memory Check the memory modules mirroring was enabled in the for failure. See system setup program, but "Troubleshooting System the current configuration Memory" on page 137. does not support redundant Reset the memory setting, memory. A memory module if appropriate. See "Using may be - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 24
Attempt Failed! attempt failed. Retry the BIOS update. If problem persists, see "Getting Help" on page 157. Caution! NVRAM_CLR jumper is NVRAM_CLR jumper installed in the clear setting. is installed on CMOS has been cleared. system board. Please run SETUP. Move the NVRAM_CLR jumper to the - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 25
Program and UEFI Boot Manager" on page 39. Decreasing available memory. Faulty or improperly installed Reseat the memory modules. memory modules. See "Troubleshooting System Memory" on page 137. DIMM configuration on each CPU should match. Invalid memory configuration on a dual-processor - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 26
set |DISABLED>, in management tools. Management Shared NIC= . Check the system management software or the System Setup program for NIC settings. If a problem is indicated, see "Troubleshooting a NIC" on page 131. Error 8602 Auxiliary Device Failure. Verify that mouse and - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 27
an intentional setting, be intentionally set lower for check any other system power conservation. messages for possible causes. The current memory Ensure that your memory configuration may support configuration supports the only the minimum frequency. higher frequency. See "General Memory - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 28
or no bootable USB key installed. Use a bootable USB key or hard drive. If the problem persists, see "Troubleshooting a USB Device" on page 130 and "Troubleshooting a Hard Drive" on page 139. See "Using the System Setup Program and UEFI Boot Manager" on page 39 for information on setting the order - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 29
in System Setup program, or no operating system on hard drive. No timer tick interrupt. Faulty system board. PCIe Training Faulty (pins 1 and 3) and reboot the system. See Figure 6-1 for jumper location. If the problem persists, see "Troubleshooting Expansion Cards" on page 142. Ensure that - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 30
are properly the disk, or the requested connected. sector is defective. See "Troubleshooting a USB Device" on page 130 or "Troubleshooting a Hard Drive" on page 139 for the appropriate drive(s) installed in your system. SATA Port x device not found. There is no device connected Information - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 31
or removed, check the SEL to determine if single-bit or multi-bit errors were detected and replace the faulty memory module. See "Troubleshooting System Memory" on page 137. The following DIMMs should match in geometry: x,x,... The following DIMMs should match in rank count: x,x,... Invalid memory - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 32
. See "Troubleshooting the System Battery" on page 134. Time-of-day not Incorrect Time or Date set - please run settings; faulty system SETUP program. battery. Check the Time and Date settings. See "Using the System Setup Program and UEFI Boot Manager" on page 39. If the problem persists, replace - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 33
Guide for instructions on performing a field replacement of the flash memory. Unexpected interrupt in protected mode. Improperly seated memory modules or faulty keyboard/mouse controller chip. Reseat the memory modules. See "Troubleshooting System Memory" on page 137. If the problem persists - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 34
event log! Check the SEL for information that was logged during the error. See the applicable troubleshooting section in "Troubleshooting Your System" on page 129 for any faulty components specified in the SEL. Warning! No micro Micro code update failed. code update loaded for processor n. Update - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 35
> Invalid memory configuration. The system runs but with reduced functionality. Ensure that the memory modules are installed in a valid configuration. See "General Memory Module Installation Guidelines" on page 81. If the problem persists, see "Troubleshooting System Memory" on page 137. About - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 36
and "Troubleshooting a Hard Drive" on page 139. NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary on support.dell.com/manuals. Warning Messages A warning message alerts you to a possible problem and prompts you to respond before the system continues a task - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 37
software, system updates, and system components that you purchased with your system. • The Lifecycle Controller User Guide provides information about setting up the controller, configuring hardware and firmware, and deploying the operating system. NOTE: Always check for updates on support.dell - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 38
38 About Your System - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 39
-level boot interface. • Unified Extensible Firmware Interface (UEFI) boot mode is an enhanced 64-bit boot interface based on UEFI specifications that overlays the system BIOS. For more information on this interface, see "Entering the UEFI Boot Manager" on page 51. Select the boot mode in the Boot - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 40
In many , left and right arrows fields, you can also type the appropriate value. Exits the System Setup program and restarts the system if any changes were made. Displays the System Setup program's help file. NOTE: For most of the options, any changes that you make are recorded - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 41
listed under their respective options in the following sections, where applicable. Option System Time System Date Memory Settings Description Sets the time on the system's internal clock. Sets the date on the system's internal calendar. Displays information related to installed memory. See "Memory - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 42
84-key keyboards). Report Keyboard Errors (Report default) Enables or disables reporting of keyboard errors during the POST. Select Report for host systems that have keyboards attached. Select Do Not Report to suppress all error messages relating to the keyboard or keyboard controller during POST - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 43
. Node Interleaving (Disabled default) If this field is Enabled, memory interleaving is supported if a symmetric memory configuration is installed. If Disabled, the system supports Non-Uniform Memory architecture (NUMA) (asymmetric) memory configurations. NOTE: The Node Interleaving field must - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 44
NOTE: Disable this feature if your system will not be running virtualization software. Adjacent Cache Line Prefetch (Enabled processor is enabled. Turbo Mode (Enabled default) If Turbo Boost Technology is supported by the processor(s), enables or disables Turbo Mode. C States (Enabled default) - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 45
Boot Sequence Retry (Disabled default) Description CAUTION: Switching the boot mode could prevent the system from booting if the operating system was not installed in the same boot mode. If the system operating system supports UEFI, you can set this option to UEFI. Setting this field to BIOS allows - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 46
and Enabled with iSCSI Boot. PXE support allows the system to boot from the network. MAC Address if the hardware and software support I/OAT. Embedded Video manually select an IRQ for a given device, or select Default to allow the BIOS to select an IRQ value at system startup. 46 Using the System - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 47
console terminal type, either (VT100/VT220 default) VT100/VT220 or ANSI. Redirection After Boot (Enabled default) Enables or disables BIOS console redirection when the operating system is loaded. Using the System Setup Program and UEFI Boot Manager 47 - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 48
and the memory power to Maximum Performance. In this setting, all processor performance information is passed from the system BIOS to the operating system for control. The operating system sets the processor performance based on processor utilization. • Active Power Controller sets the CPU power to - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 49
TPM Security is set to Off. CAUTION: Clearing the TPM will lose all encryption keys in the TPM. This option prevents booting to the operating system and results in data loss if the encryption keys cannot be restored. Back up the TPM keys prior to enabling this option. When set to - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 50
Disabled default) CAUTION: Use the NMI button only if directed to do so by qualified support personnel or by the operating system's documentation. Pressing this button halts the operating system and displays a diagnostic screen. Enables or disables the NMI feature. AC Power Recovery (Last default - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 51
x 64 version) to be installed from the UEFI boot mode. DOS and 32-bit operating systems can only be installed from the BIOS boot mode. NOTE: The Boot Mode must be set to UEFI in the System Setup program to access the UEFI Boot Manager. The UEFI Boot Manager enables you to - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 52
, delete, enable, or disable boot options; change boot order; or execute a one-time boot option. Enables you to access the System Setup program, System Services (USC), Diagnostics, and BIOS-level boot options. UEFI Boot Settings Screen Option Add Boot Option Delete Boot Option Enable/Disable Boot - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 53
switch to BIOS boot mode if you need to boot to a device with a non-UEFI operating system, such as a bootable DOS media with diagnostics software. Restarts the system. System and Setup Password Features NOTE: For a forgotten password, see "Disabling a Forgotten Password" on page 154. Your - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 54
assignment is not case-sensitive. To erase a character, press or the left-arrow key. NOTE: To escape from the field without assigning a system password, press to move to another field, or press prior to completing step 5. 4 Press . 5 To confirm your password, type it - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 55
to enter the correct password. After the third unsuccessful attempt, the system displays an error message that the system has halted and must be shut down manually using the power button. Even after you shut down and restart the system, the error message continues to be displayed until the correct - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 56
, press or the left-arrow key. When you verify the password, the Setup Password changes to Enabled. The next time you enter the System Setup program, the system prompts you for the setup password. A change to the Setup Password option becomes effective immediately (restarting the - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 57
about setting up the controller, configuring hardware and firmware, and deploying the operating system, see the Lifecycle Controller User Guide on the Dell Support website at support.dell.com/manuals. Baseboard Management Controller Configuration NOTE: If an iDRAC6 Express card is installed on - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 58
Trap (PET) destination. • Attach or detach the Virtual Media devices. • Change the administrative username and password and manage user privileges. • View System Event Log (SEL) messages or clear messages from the log. For additional information on using iDRAC6, see the documentation for iDRAC6 and - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 59
If your operating system begins to load before you press , allow the system to finish booting, restart your system and try again. Using the System Setup Program and UEFI Boot Manager 59 - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 60
60 Using the System Setup Program and UEFI Boot Manager - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 61
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 62
Figure 3-1. Inside the System 5 4 3 2 1 6 10 1 cooling fan 3 expansion-card riser 5 cooling shroud 7 memory modules (8) 9 SAS backplane 7 8 9 2 internal hard drives (2) 4 power supply bays (2) 6 heat sink/processor (2) 8 system cooling fans (4) 10 hard drives (12) 62 Installing System Components - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 63
the left end of the bezel away from the front panel. 4 Unhook the right end of the bezel and pull the bezel away from the system. Figure 3-2. Removing and Installing the Front Bezel 3 2 1 1 release latch 3 bezel 4 2 keylock 4 hinge tab Installing - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 64
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 65
Figure 3-3. Opening and Closing the System 2 1 1 system cover latch 2 latch release lock Closing the System 1 Lift the latch on the system cover. 2 Place the cover onto the chassis and offset it slightly back so that the two hooks on the back edge of the cover fit - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 66
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 67
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 68
. See "Removing the Front Bezel" on page 63. 2 Using the RAID management software, prepare the drive for removal. Wait until the hard-drive indicators on the drive carrier 68. CAUTION: To maintain proper system cooling, all empty hard-drive bays must have hard-drive blanks installed. 68 Installing - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 69
: To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the documentation supplied with the operating system. CAUTION: Combining SATA and SAS hard drives in the same system configuration is not supported on all configurations. 1 If applicable, remove the - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 70
drive from the carrier. See Figure 3-7. Figure 3-7. Installing a Hot-Swap Hard Drive Into a Drive Carrier 1 4 3 1 hard drive 3 drive carrier 2 2 SAS/SATA indicator 4 screws (4) 70 Installing System Components - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 71
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 72
Figure 3-8. Removing and Installing an Internal Hard Drive Bay 2 3 1 4 1 internal hard drives (2) 3 internal hard drive bay 2 release latch 4 support bracket 72 Installing System Components - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 73
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 74
screws (4) * 2 release latch 4 internal hard drive *Screws are supplied along with the hard drives ordered from Dell. Installing a Hard Drive Into a Hard-Drive Bay 1 Insert the hard drive into the internal hard-drive bay the hard drive to the hard-drive bracket. 74 Installing System Components - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 75
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 76
Figure 3-10. Removing and Installing a Fan 2 1 3 1 fans (5) 3 fan power cable 2 release tab 76 Installing System Components - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 77
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 78
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions see the system's rack - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 79
you unlatched the cable management arm in step 2 of the previous procedure, relatch it. For information about the cable management arm, see the system's rack documentation. 3 Connect the power cable to the power supply and plug the cable into a power outlet. CAUTION: When connecting the power cable - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 80
the power supply blank, align the blank with the power supply bay and insert the blank into the chassis until it clicks into place. System Memory Your system supports DDR3 registered DIMMs (RDIMMs) or unbuffered ECC DIMMs (UDIMMs). Single and dual-rank DIMMs can be 1067- or 1333-MHz, and quad-rank - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 81
to 128 GB. • 1-GB and 2-GB UDIMMs are supported for a total of up to 16 GB. General Memory Module Installation Guidelines To ensure optimal performance of your system, observe the following general guidelines when configuring your system memory. NOTE: Memory configurations that fail to observe these - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 82
- and x8-based memory modules. Memory modules must be identical in size, speed, and technology in corresponding slots. Memory Mirroring Support The system supports memory mirroring if identical memory modules are installed in the two channels closest to the processor (memory should not be installed - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 83
Physical Available Memory Memory (GB) (GB) 2 all 4 6 8 4 all 8 12 16 8 all 16 24 32 16 all 32 48 64 32 all 64 96 128 Installing System Components 83 - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 84
Available Memory Memory (GB) (GB) 1 all 2 3 4 2 all 4 6 8 2 all 4 all Dual Processor Physical Available Memory Memory (GB) (GB) 2 all 4 6 8 4 all 8 12 16 4 all 8 all 84 Installing System Components - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 85
after the system has been troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 86
procedure to install the remaining memory modules. See Table 2. 10 Replace the cooling shroud. See "Installing the Cooling Shroud" on page 67. 11 Close the system. See "Closing the System" on page 65. 86 Installing - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 87
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 88
to their power sources, and turn them on. Expansion Cards and Expansion-Card Risers Your system supports up to four PCI Express (PCIe) expansion cards installed in connectors on an expansion-card riser. Your system has an expansion-card riser 1 that provides three x4 Gen2 PCIe expansion-card slots - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 89
storage controller. • Table 3 provides a guide for installing expansion cards to ensure proper cooling 6 HPCC 7 Fibre Channel 8 10 Gb NIC 9 All other NICs 10 All other Dell internal storage cards 11 Non-Dell storage cards * When available Slot Priority 1, 2 3, 2 3, 2 3, 2 3, 2 2, 1 2, - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 90
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 91
Card 2 1 3 1 expansion-card riser 3 expansion card 2 expansion-card latch 9 Connect any cables to the expansion card. 10 Close the system. See "Closing the System" on page 65. 11 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. Installing - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 92
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 93
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 94
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. 1 To install an expansion-card riser, align the riser guides with the riser guide posts on the system board - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 95
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 96
7 Bend both the card-edge guides outward and pull the storage controller card out of the connector. Figure 3-15. Installing and Removing the Storage card 5 SAS data cable connector 2 expansion-card riser 4 storage controller card cable 6 release lever (blue) 96 Installing System Components - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 97
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 98
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 99
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 100
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions the system back panel - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 101
posts (2) 6 iDRAC6 Enterprise card connector 7 If applicable, install the VFlash media card. See "Installing a VFlash Media Card" on page 103. 8 Close the system. See "Closing the System" on page 65. 9 Reconnect the system and peripherals to their power sources, and turn them on. Installing - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 102
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 103
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 104
the lever from the locked position. Rotate the lever 90 degrees upward until the processor is released from the socket. See Figure 3-19. 104 Installing System Components - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 105
. CAUTION: Be careful not to bend any of the pins on the ZIF socket when removing the processor. Bending the pins can permanently damage the system board. NOTE: In single-processor configurations, a processor must be installed in socket CPU1. Install the blank in socket CPU2 only. Installing - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 106
Figure 3-19. Installing and Removing a Processor 1 2 3 6 1 processor 3 notch in processor 5 ZIF socket 4 5 2 processor shield 4 socket key 6 socket-release lever 106 Installing System Components - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 107
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions the system board or - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 108
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 109
Figure 3-20. Replacing the System Battery 1 3 2 1 system battery 3 positive side of battery connector 2 avoid damage to the battery connector, you must firmly support the connector while installing or removing a battery. 8 Support the battery connector by firmly holding the positive side of - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 110
out of the securing tab at the negative side of the connector. 10 Support the battery connector by pressing down firmly on the positive side of the 11 Hold the new battery with the "+" facing the plastic connector on the system board and slide it under the securing tabs. 12 Press the battery straight - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 111
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 112
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 113
6 Remove the power button board and power button from the control-panel module. Figure 3-22. Removing and Installing the Control Panel-LED 2 1 3 4 5 1 bracket 3 power button board 5 control-panel module 2 control-panel cable 4 power button Installing System Components 113 - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 114
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 115
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions to the system chassis and - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 116
Figure 3-23. Removing and Installing the Front-Panel I/O Module 1 2 3 4 1 front-panel I/O cable 3 front-panel I/O module 2 bracket 4 mounting screws (3) 116 Installing System Components - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 117
of the system chassis and troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 118
3-24. 10 When the backplane cannot slide upward any further, pull the backplane toward the back of the system to remove it from the retention hooks. 11 Lift the board out of the system, being careful to avoid damaging components on the face of the board. 12 Place the SAS backplane face - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 119
7 control panel cable 9 USB cable 2 backplane retention latches (2) 4 control panel module cable 6 SAS backplane power cable 8 internal hard drive cables (2) 10 SAS backplane cable Installing System Components 119 - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 120
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 121
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions system board (see "System - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 122
Figure 3-25. Removing and Installing the Power Distribution Board 3 4 2 1 6 1 screws (3) 3 power-interposer board 5 power-distribution board 5 2 power supply connector 4 blue tab 6 fan module cable connector 122 Installing System Components - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 123
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 124
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 125
module, processor, or other components. 12 Grasp the system board assembly by the edges and lift the system board assembly away from the chassis. See Figure 3-26. Figure 3-26. Removing and Installing the System Board 2 1 1 screws (9) 2 system board assembly Installing System Components 125 - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 126
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 127
Replace the cooling shroud. See "Installing the Cooling Shroud" on page 67. 16 Close the system. See "Closing the System" on page 65. 17 Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. 18 If applicable, replace the front bezel. See "Removing - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 128
128 Installing System Components - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 129
by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. Troubleshooting System Startup Failure If your system halts during startup prior to - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 130
replace the faulty keyboard/mouse. If the problem is not resolved, proceed to the next step to begin troubleshooting the other USB devices attached to the system. 5 Turn off all attached USB devices and disconnect them from the system. 6 Restart the system and, if your keyboard is functioning, enter - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 131
the device, replace the USB cable, and power up the device. If the problem persists, replace the device. If all troubleshooting fails, see "Getting Help" on page 157. Troubleshooting a Serial I/O Device 1 Turn off the system and any peripheral devices connected to the serial port. 2 Swap the serial - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 132
the System Setup program troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 133
down the system and reinstall all of the expansion cards that you removed. See "Installing an Expansion Card" on page 90. 9 Run the appropriate online diagnostic test. See "Using Online Diagnostics" on page 147. If the tests fail, see "Getting Help" on page 157. Troubleshooting Your System 133 - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 134
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 135
support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. If the problem is not resolved by replacing the battery, see "Getting Help" on page 157. NOTE: Some software may cause the system - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 136
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 137
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 138
the diagnostic indicators on the front of the system. 21 If the memory problem is still indicated, repeat step 14 through step 20 for each memory module installed. If the problem persists after all memory modules have been checked, see "Getting Help" on page 157. 138 Troubleshooting Your System - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 139
service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. CAUTION: This troubleshooting utility and allow the system to boot to the operating system. 4 Ensure that the - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 140
service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. CAUTION: This troubleshooting the following steps: a Restart the system and enter the host adapter configuration - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 141
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 142
or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. NOTE: When troubleshooting an expansion card, see the documentation for your operating system and the - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 143
the electrical outlet. b Open the system. See "Opening the System" on page 64. c Reinstall one of the expansion cards. d Close the system. See "Closing the System" on page 65. e Run the appropriate diagnostic test. If the tests fail, see "Getting Help" on page 157. Troubleshooting Your System 143 - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 144
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 145
the System" on page 64. 16 Replace processor 1 with processor 2. See "Installing a Processor" on page 107. 17 Repeat step 11 through step 13. If you have tested both the processors and the problem persists, the system board is faulty. See "Getting Help" on page 157. Troubleshooting Your System 145 - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 146
146 Troubleshooting Your System - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 147
loss. If you are unable to fix the problem yourself, service and support personnel can use diagnostics test results to help you solve the problem. Using Online Diagnostics To assess a system problem, first use the Online Diagnostics. Dell™ Online Diagnostics is a suite of diagnostic programs, or - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 148
inform you if tests are completed successfully • View error messages that inform you of problems encountered during testing When to Use the Embedded System Diagnostics If a major component or device in the system does not operate properly, component failure may be indicated. As long as the processor - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 149
Test Custom Test Information Function Performs a quick check of the system. This option runs device tests that do not require user interaction. Performs a more thorough check of the system. This test can take an hour or longer. Tests a particular device - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 150
, or test. • Configuration - Displays basic configuration information about the currently selected device. • Parameters - Displays parameters that you can set for the test. 150 Running the System Diagnostics - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 151
and describes the connectors on the various boards in the system. System Board Jumpers Figure 6-1 shows the location of the configuration jumpers on the system board. Table 6-1 lists the jumper settings. Table 6-1. System Board Jumper Settings Jumper PWRD_EN NVRAM_CLR Setting (default) (default - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 152
System Board Connectors See Figure 6-1 and Table 6-2 for the location and description of the system board connectors. Figure 6-1. System Board Connectors 1 2 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 3 4 6 5 152 Jumpers and Connectors - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 153
(white release lever) A1 Memory module slot A1 (white release lever) A4 Memory module slot A4 8 FAN3 Cooling fan 3 connector 9 BATTERY System battery 10 FAN4 Cooling fan 4 connector 11 12V 8-pin power connector 12 FP_CONN control panel connector 13 BP_CONN Backplane power connector - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 154
only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 155
enabled position to restore the password function. See Table 6-1. 9 Close the system. See "Closing the System" on page 65. 10 Reconnect your system and peripherals to their electrical outlets, and turn on the system. 11 Assign a new system and/or setup password. To assign a new password using the - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 156
156 Jumpers and Connectors - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 157
, or Dell product catalog. Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues: 1 Visit support.dell.com - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 158
158 Getting Help - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 159
shroud installing, 67 removing, 66 cover closing, 65 opening, 64 D damaged systems troubleshooting, 134 Dell contacting, 157 Dell PowerEdge Diagnostics using, 147 diagnostics advanced testing options, 149 testing options, 149 using Dell PowerEdge Diagnostics, 147 when to use, 148 Index 159 - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 160
DIMMs See memory modules (DIMMs). drive blank installing, 68 removing, 67 E Embedded System Management, 57 error messages, 40 expansion card troubleshooting, 142 expansion cards installing, 90 removing, 92 SAS controller, 95 expansion slots, 88 F front-panel features, 12 front-panel IO module, 115 - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 161
, 21 warning, 36 N NIC indicators, 17 NICs back-panel connectors, 15 troubleshooting, 131 O Optimizer memory mode, 82 P password setup, 55 system, 53 passwords disabling, 154 phone numbers, 157 POST accessing system features, 11 power indicators, 12, 18 power supplies indicators, 18 removing, 78 - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 162
. startup accessing system features, 11 support contacting Dell, 157 system closing, 65 opening, 64 system board connectors, 152 installing, 126 jumpers, 151 removing, 124 system cooling troubleshooting, 136 system features accessing, 11 system messages, 21 system password, 53 system setup program - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 163
options, 48 processor settings, 43 serial communications options, 47 system security options, 48 system setup screens main, 41 T telephone numbers, 157 TPM security, 48 troubleshooting battery, 134 cooling fans, 136 damaged system, 134 expansion card, 142 external connections, 129 hard drive - Dell PowerVault DL2200 CommVault | Hardware Owner's Manual - Page 164
164 Index
Dell™ PowerVault™
DL2200 Systems
Hardware Owner’s
Manual
Regulatory Model E13S Series
Regulatory Type E13S001