Dell PowerVault MD3200 CLI Guide - Page 161

Download Storage Array Firmware/NVSRAM

Page 161 highlights

Parameters Parameter physicalDisk filename Description Physical disk to which to download the firmware image. Specify the enclosure ID and slot ID for the physical disk. Enclosure ID values are 0 to 99. Slot ID values are 0 to 31. You must put brackets ([ ]) around the enclosure ID value and slot ID value. File path and file name of the file that contains the firmware image. You must put quotation marks (" ") around the firmware image file path and file name. Download Storage Array Firmware/NVSRAM This command downloads firmware and, optionally, NVSRAM values for the RAID controller module in the storage array. If you want to download only NVSRAM values, use the downLoad storageArray NVSRAM command. Syntax download storageArray firmware [, NVSRAM ] file="filename" [, "NVSRAM-filename"] [downgrade=(TRUE | FALSE)] [activateNow=(TRUE | FALSE)] Parameters Parameter NVSRAM file Description Specifies that you want to download a file with NVSRAM values when you download a firmware file. You must not put brackets around this parameter. Include a comma after the term firmware. File path and name of the file that contains the firmware. Valid file names must end with a .dlp extension. You must put quotation marks (" ") around the file name. Script Commands 161

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279

Script Commands
161
Parameters
Download Storage Array Firmware/NVSRAM
This command downloads firmware and, optionally, NVSRAM values for the
RAID controller module in the storage array. If you want to download only
NVSRAM values, use the
downLoad storageArray NVSRAM
command.
Syntax
download storageArray firmware [, NVSRAM ]
file="
filename
" [, "
NVSRAM-filename
"]
[downgrade=(TRUE | FALSE)]
[activateNow=(TRUE | FALSE)]
Parameters
Parameter
Description
physicalDisk
Physical disk to which to download the
firmware image. Specify the enclosure ID
and slot ID for the physical disk.
Enclosure ID values are 0 to 99. Slot ID
values are 0 to 31. You must put brackets
([ ]) around the enclosure ID value and
slot ID value.
filename
File path and file name of the file that
contains the firmware image. You must
put quotation marks (" ") around the
firmware image file path and file name.
Parameter
Description
NVSRAM
Specifies that you want to download a file
with NVSRAM values when you
download a firmware file. You must not
put brackets around this parameter.
Include a comma after the term
firmware
.
file
File path and name of the file that contains
the firmware. Valid file names must end
with a
.dlp
extension. You must put
quotation marks (" ") around the file name.