Troubleshooting RX and TX Pause Warning Messages Description Cause Workaround The following warning messages may be displayed when the NAS Manager reports connectivity in a Not Optimal state: Rx_pause for eth(x) on node 1 is off. Tx_pause for eth(x) on node 1 is off. Flow control is not enabled on the switch(es) connected to a PowerVault NX3500 controller. See the switch vendor's documentation to enable flow control on the switch(es). Identifying Controllers Description Workaround Identifying PowerVault NX3500 controllers. To identify a controller, use the LCD located on the front panel of the PowerVault NX3500 controller. The LCD displays systemname.controller#. For example, NX3500.Controller0 Determining the IQN of the PowerVault NX3500 Controllers Using CLI Description Workaround Determining the IQN of the PowerVault NX3500 controllers using CLI. Using an ssh client and the NAS Management VIP, log in to the PowerVault NX3500 solution CLI as an admin. From the command line type the following command: system maintenance luns iscsiconfiguration view 190 Troubleshooting